PubMed Health⌕ Search

Biomedical subjects

Franz Watzinger

Publications and source records attributed to Franz Watzinger.

At least 19 recordsLinked to original sources

Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis?

OBJECTIVE: Biodegradable materials are particularly useful for the fixation of zygomatic fractures. Different systems are commercially available. The aim of this study was to compare the clinical outcome of zygomatic fracture fixation using 3 biodegradable systems and a titanium osteosynthesis system. STUDY DESIGN: Patients with displaced fractures of the zygomatic bone presenting at our department from October 2001 to May 2003 were randomly allocated to 1 of 3 treatment groups for fracture fixation (study group A: LactoSorb: n = 18; study group B: BioSorb: n = 18; study group C: Delta: n = 18). Treatment outcome and complication rates were compared with a historic patient group with zygomatic fractures fixed with titanium osteosynthesis (control group D: n = 15). RESULTS: A total of 64 patients (study groups A + B + C: n = 49; control group D: n = 15) were followed for at least 24 months (range: 24 to 44 months). Forty-nine patients in the biodegradable study groups (group A: n = 15; group B: n = 17; group C: n = 17) who had their fractures fixed with biodegradable plates and screws alone or in combination with titanium plates and screws were reviewed postoperatively. Uneventful healing occurred during the entire follow-up period in 39 (80%) out of 49 patients in the biodegradable groups (A + B + C) and in 12 (80%) out of 15 patients in group D. Ten patients in groups A + B + C developed postoperative complications (infection: n = 3; soft tissue dehiscence: n = 2; implant-related tissue reactions: n = 5), compared with 3 patients in group D (soft tissue dehiscence: n = 1; unspecific pain: n = 2) (P = .97). Complications occurred in 4 patients in group A and 3 patients each in groups B and C. Smokers developed significantly more postoperative complications than nonsmokers in groups A + B + C (P = .01). CONCLUSION: There was no significant difference between biodegradable osteosynthesis materials or between biodegradable materials and titanium fixation with respect to fracture healing and postoperative complications. Postoperative complications were of a minor nature and resolved spontaneously or after local therapy. Smoking habits may play a significant role in the incidence of complications with biodegradable materials.

Absorbable Implants↗

Bone morphogenetic proteins 5 and 6 stimulate osteoclast generation.

Bone regeneration is required for fracture-healing, and different procedures have been used to promote osteogenesis. Recently, BMP-2 has been shown to induce bone formation in vivo and has been tested in clinical trials. A recent in vitro study evaluated the osteogenic activity of 14 BMPs on osteoblastic progenitor cells with an osteogenic hierarchical model in which BMP-2 and BMP-6 may play an important role in inducing osteoblast differentiation. Although the relative osteoinductive activity of each BMP is important, bone regeneration is a process consisting of bone formation and bone resorption. Therefore, it remains unclear which effects BMP-5 and -6 have on the generation of osteoclasts and by which mechanism osteoclastogenesis is stimulated. To compare osteoclastic potency of each BMP, primary murine bone marrow cells were treated with human recombinant BMP-2, BMP-5, or BMP-6 and 1,25-(OH)2 vitamin D3 and stained for the TRAP enzyme. Osteogenic activity of BMP-5 was determined by measuring induction of ALP-activity and proliferation after incubation with primary murine osteoblasts. For elucidating the molecular mechanism, primary bone marrow cells with various concentrations of OPG were added to the TRAP assay and mRNA levels of RANKL and OPG were measured after stimulation with BMP-5. The presented data show that BMP-5 and BMP-6, unlike BMP-2, enhanced the formation of murine TRAP+/MNCs in a biphasic curve. BMP-5 and -6 were less potent in stimulating osteoclastogenesis compared to BMP-2. Concerning the effects of BMP-5 on osteoblasts, there was a dose-dependent increase of ALP activity and proliferation up to a maximum dose of 300 ng/mL. At the mRNA level, BMP-5 increased the RANKL/OPG ratio. In conclusion, this study demonstrates that in contrast to BMP-2, BMP-5 and -6 influences the generation of osteoclasts in a biphasic mode. Both proteins might be very important regulators of bone homeostasis, and therefore, potent candidates for future treatment strategies of bone regeneration.

Acid Phosphatase↗

Point-to-point computer-assisted navigation for precise transfer of planned zygoma osteotomies from the stereolithographic model into reality.

PURPOSE: To evaluate the feasibility and accuracy of a new method for planning and realizing zygomatic osteotomies in cases of established post-traumatic deformities using stereolithographic (SL) models and computer assisted navigation. PATIENTS AND METHODS: In 5 patients, osteotomy and repositioning of the zygomatic complex was planned using SL models. The desired position of the zygoma in the patient was determined by fixing individualized osteosynthesis plates to predefined screw positions. The SL model and the patient were registered to the same 3-dimensional computed tomography data set via an occlusal reference frame on the patient and corresponding reference markers on the model. Prebent osteosynthesis plates from the surgical simulation on the model were fixed to corresponding screw positions on the patient, which were located by computer-assisted navigation. Evaluation of accuracy was performed by image fusion of postoperative computed tomography scans of the model and the patient. RESULTS: Clinical outcome was satisfactory in all cases. The evaluation by image fusion showed alignment of the patient's and the model's zygoma in 4 of 5 cases. Mean measured distance between screw positions in the models and the patients were 1.1 +/- 0.3 mm for 44 screws. In 1 patient the treatment plan was changed intraoperatively because of unforeseen soft tissue limitations. CONCLUSION: Point-to-point navigation is an accurate method to transfer the planning of a complex osteotomy from the SL model to the actual surgical procedure. Surgery is facilitated considerably because repositioning and osteosynthesis are achieved in 1 step.

Adult↗

Implant survival in mandibles of irradiated oral cancer patients.

OBJECTIVE: The aim of this study was to analyze long-term implant survival in the mandible after radiotherapy and radical surgery in oral cancer patients. STUDY DESIGN: Between 1990 and 2003, 71 patients (15 females, 56 males; average age 57.8 years, range 16-84.1 years) were treated with dental implants after radiochemotherapy and ablative surgery of oral cancer. Radiation therapy was delivered in daily fractions of 2 Gy given on 25 days (total dose of 50 Gy). Oral defects were reconstructed microsurgically with jejunal, iliac crest or radial forearm grafts. Thereafter 316 dental implants were placed in the non-irradiated residual bone (84; 27%), irradiated residual bone (154; 49%) or grafted bone (78; 25%) at various intervals (mean interval 1.41 (+/- 1.01) years, range 0.34-6.35 years). RESULTS: The mean follow-up time after implant insertion was 5.42 (+/- 3.21) years (range 0.3-13.61 years). The overall 2-, 3-, 5-, and 8-year survival rates of all implants were 95%, 94%, 91% and 75%. Forty-four implants were lost in 21 patients during the observation period. Irradiation of the mandibular bone showed significantly (P = 0.0028) lower implant survival compared with non-irradiated mandibular bone. The 8-year survival rate in the non-irradiated residual bone (two loss), irradiated residual bone (29 loss) or grafted bone (13 loss) were 95%, 72% and 54%, respectively. Time of implantation after irradiation showed no statistically significant influence. Implant brand, length or diameter or the incidence of resective surgery on the mandible and gender of patients had no statistically significant influence on implant survival. CONCLUSION: Radiation therapy with 50 Gy was significantly related to shorter implant survival in mandibular bone. Survival was lowest in grafted bone. Time of implant placement had no statistically significant influence on survival under the conditions of this study. Although implant survival is lower in irradiated mandibles, implants significantly facilitate prosthodontic treatment and enhance outcome of oral rehabilitation in cancer patients.

Adolescent↗

Accuracy of treatment planning based on stereolithography in computer assisted surgery.

Three-dimensional stereolithographic models (SL models), made of solid acrylic resin derived from computed-tomography (CT) data, are an established tool for preoperative treatment planning in numerous fields of medicine. An innovative approach, combining stereolithography with computer-assisted point-to-point navigation, can support the precise surgical realization of a plan that has been defined on an SL model preoperatively. The essential prerequisites for the application of such an approach are: (1) The accuracy of the SL models (including accuracy of the CT scan and correspondence of the model with the patient's anatomy) and (2) the registration method used for the transfer of the plan from the SL model to the patient (i.e., whether the applied registration markers can be added to the SL model corresponding to the markers at the patient with an accuracy that keeps the "cumulative error" at the end of the chain of errors, in the order of the accuracy of contemporary navigation systems). In this study, we focus on these two topics: By applying image-matching techniques, we fuse the original CT data of the patient with the corresponding CT data of the scanned SL model, and measure the deviations of defined parameter (e.g., distances between anatomical points). To evaluate the registration method used for the planning transfer, we apply a point-merge algorithm, using four marker points that should be located at exactly corresponding positions at the patient and at connective bars that are added to the surface of the SL model. Again, deviations at defined anatomical structures are measured and analyzed statistically. Our results prove sufficient correspondence of the two data sets and accuracy of the registration method for routine clinical application. The evaluation of the SL model accuracy revealed an arithmetic mean of the relative deviations from 0.8% to 5.4%, with an overall mean deviation of 2.2%. Mean deviations of the investigated anatomical structures ranged from 0.8 mm to 3.2 mm. An overall mean (comprising all structures) of 2.5 mm was found. The fiducial registration error of the point-merge algorithm ranged from 1.0 mm to 1.4 mm. The evaluated chain of errors showed a mean deviation of 2.5 mm. This study verifies that preoperative planning on SL models and intraoperative transfer of this plan with computer assisted navigation is a suitable and sufficiently reliable method for clinical applications.

Algorithms↗

Chimerism analysis following nonmyeloablative stem cell transplantation.

Molecular monitoring of hematopoietic chimerism has become a routine diagnostic approach in patients after allogeneic stem cell transplantation. Chimerism testing permits the documentation and surveillance of engraftment and facilitates early detection of impending graft rejection. In patients transplanted for treatment of malignant hematological disorders, monitoring of chimerism can provide an early indication of incipient disease relapse. The investigation of chimerism has therefore become an indispensable tool for the management of patients during the posttransplant period. Growing use of nonmyeloablative conditioning, which is associated with prolonged duration of mixed hematopoietic chimerism, has further increased the clinical importance of chimerism analysis. At present, the most commonly used technical approaches to the investigation of chimerism include microsatellite analysis by polymerase chain reaction and, in the gender-mismatched transplant setting, fluorescence in situ hybridization analysis of sex chromosomes. The investigation of chimerism within specific leukocyte subsets isolated from peripheral blood or bone marrow samples by flow-sorting or magnetic bead-based techniques provides more specific information on processes underlying the dynamics of donor/recipient chimerism. Moreover, cell subset-specific analysis permits the assessment of impending complications at a significantly higher sensitivity, thus providing a basis for earlier treatment decisions.

Antigens, CD↗

Mutation analysis of CLPTM 1 and PVRL 1 genes in patients with non-syndromic clefts of lip, alveolus and palate.

INTRODUCTION: Non-syndromic cleft lip with or without cleft palate (CL/P), is one of the most common birth defects, but its aetiology is largely unknown. The aim of this study was to determine the sequence changes of the Cleft Lip and Palate Transmembrane Protein 1 (CLPTM 1) and Poliovirus Receptor Related 1 (PVRL 1) genes in patients with non-syndromic complete clefts of lip, alveolus and palate and to correlate these findings with clinical features. PATIENTS AND METHODS: 25 patients were analysed (14 male and 11 female, aged 4-10 years) of European descent (9 patients with right, 9 with left and 7 patients with bilateral CLAP) and 25 controls, respectively. Exons 2-14 of the CLPTM1 and exons 1-6 of the PVRL1 gene were analysed by a direct sequencing method using DNA extracted from whole blood. RESULTS: A novel in frame Glu441-Gly442 ins Glu mutation of the PVRL 1 gene in combination with novel exon mutations Gly331Gly, Ala88Ala, Pro309Pro and intron change IVS7-10G/A of the CLPTM 1 gene were found in 9 patients. The Glu441-Gly442 ins Glu mutation and the intron change IVS7-10G/A were not detected in 25 controls. CONCLUSION: These results suggest that a simultaneous occurrence of PVRL1 and CLPTM 1 gene mutations in cleft patients does not correlate with the type of cleft (left, right, bilateral) or the gender of the patients. If a combination of the intron change IVS7-10G/A, exon changes Gly331Gly, Ala88Ala and Pro309Pro of the CLMPT 1 gene and Glu441-Gly442 ins Glu mutation of the PVRL 1 gene could be a genetic factor for non-syndromic clefts of the primary and the secondary palates, it is important to investigate more patients and controls.

Alanine↗

Biodegradable fixation of mandibular fractures in children: stability and early results.

OBJECTIVE: The aim of this study was to assess the safety and efficiency of biodegradable self-reinforced (SR-PLDLA) bone plates and screws in open reduction and internal fixation of mandible fractures in children. STUDY DESIGN: Thirteen patients (5 female, 8 male; mean age 12 years, range 5-16 years) were operated on various fractures of the mandible (2 symphyseal, 6 parasymphyseal, 4 body, 3 angle, 1 ramus, 2 condylar fractures). The mean follow-up time was 26.4 months (range 10.9-43.4 months). Intermaxillary fixation was applied in cases with concomitant condylar fractures up to 3 weeks. RESULTS: Primary healing of the fractured mandible was observed in all patients. Postoperative complications were minor and transient. The outcome of the operations was not endangered. Adverse tissue reactions to the implants, malocclusion, and growth restrictions did not occur during the observation period. CONCLUSIONS: Pediatric patients benefit from the advantages of resorbable materials, especially from faster mobilization and the avoidance of secondary removal operations. Based on these preliminary results, self-reinforced fixation devices are safe and efficient in the treatment of pediatric mandible fractures. However, further clinical investigations are necessary to evaluate the long-term reliability.

Absorbable Implants↗

An evaluation of the clinical application of three different biodegradable osteosynthesis materials for the fixation of zygomatic fractures.

OBJECTIVE: The aim of this prospective study was to compare the clinical handling of 3 different biodegradable osteosynthesis materials and to determine whether they can be used for the fixation of all types of zygomatic fractures. STUDY DESIGN: A total of 54 consecutive patients who presented with displaced fractures of the zygomatic bone between October 2001 and May 2003 were randomly allocated to 3 biodegradable material groups for the fixation of the fractures. A titanium fixation system was used as rescue osteosynthesis whenever biodegradable materials failed. RESULTS: Seventy-one (75.5%) of 94 fracture sites were fixed with biodegradable osteosynthesis; 23 (24.5%) had to be fixed with titanium plates and screws. No statistically significant difference was found between the 3 biodegradable materials with regard to their suitability for zygomatic fracture fixation (P = .16). Nonstable fixation (n = 7) or the need to fix small fragments (n = 16) were the reasons for using the titanium fixation system as rescue osteosynthesis at these sites. Biodegradable materials were most frequently unfeasible for use at the infraorbital rim and in the zygomaticomaxillary/anterior sinus wall area. CONCLUSIONS: It was possible to stabilize 3 of 4 zygomatic fractures with 1.5- or 1.7-mm biodegradable osteosynthesis. Insufficient fracture stabilization, especially at the infraorbital rim and the zygomaticomaxillary crest/anterior sinus wall, was the main reason to switch to titanium osteosynthesis. The biodegradable screw design is possibly too bulky for these particular bony structures.

Absorbable Implants↗

Evaluation of esthetic, functional, and quality-of-life outcome in adult cleft lip and palate patients.

OBJECTIVE: Evaluation of esthetic, functional, and health-related quality-of-life (HRQoL) outcomes in adult patients with a repaired cleft lip and palate. The treatment for all patients was based on the so-called Vienna concept. PATIENTS/DESIGN: Seventy adult patients with a repaired complete cleft lip and palate, ranging in age from 18 to 30 years, were included in the study. Esthetic and functional outcomes were assessed by the patients themselves and by five experts using a visual analog scale. Patients also completed the MOS Short-Form 36 questionnaire to evaluate health-related quality of life. RESULTS: Patients rated their esthetic outcome significantly worse than the experts did. No significant differences were observed in the ratings for function. Female patients, especially, were dissatisfied with their esthetic outcomes. In a personal interview, nearly 63% of them asked for further treatment, particularly for upper-lip and nose corrections. The health-related quality-of-life questionnaire revealed low scores for only two subscales, namely social functioning and emotional role. In most subscales of health-related quality of life, patients who desired further treatment had significantly lower scores than did patients who desired no further treatment. CONCLUSION: Surgery of the lip and nose appears to be of prime importance for patients with a cleft lip and palate. Cleft patients who do not request secondary treatment are not always satisfied with the treatment. Patients with realistic expectations in regard to further treatment should be treated by specialists, whereas those with unrealistic expectations should be referred to a clinical psychologist.

Adaptation, Physiological↗

Van Der Woude syndrome: variable penetrance of a novel mutation (p.Arg 84Gly) of the IRF6 gene in a Turkish family.

Van der Woude syndrome (VWS) is an autosomal dominant disorder characterized by clefts of the lip and/or palate (CL+/-P), lip pits, bifid uvula and hypodontia. Mutations of the interferon regulatory factor 6 gene (IRF6) have been recently described in patients with VWS. The entire 9 exons of the IRF6 gene in two brothers of Turkish origin clinically diagnosed with Van der Woude syndrome and four healthy family members were screened for mutations using a newly established denaturing gradient gel electrophoresis (DGGE) method. A novel heterozygous mutation in exon 2 (DNA binding region) of the IRF6 gene, p.Arg84Gly, was found in both brothers with VWS and in their clinically asymptomatic mother. Our results suggest a dominant negative effect of the p.Arg84Gly mutation in the VWS of both patients. Non-penetrance of this mutation is suggested in the mother of the patients.

5' Untranslated Regions↗

Rehabilitation of the severely atrophied maxilla by horseshoe Le Fort I osteotomy (HLFO).

OBJECTIVE: The purpose of this study was to determine the long-term outcome of the horseshoe Le Fort I osteotomy (HLFO) as a preprosthetic operation technique for implant insertion in the extremely atrophied maxilla. STUDY DESIGN: 36 patients (8 male, 28 female, average age 57.6 years) underwent HLFO combined with iliac crest bone grafting. They were divided into 2 groups: group A with 12 patients who simultaneously received 100 implants; group B with 24 patients where 176 implants were inserted in 18 patients in a second-stage procedure. Clinical and radiographic outcome with regard to implant osseointegration, alveolar bone height in the canine and molar regions, peri-implant bone loss and satisfaction of patients (esthetics, masticatory function, overall treatment) were investigated in all cases. RESULTS: The overall 2-year failure-free fraction of implants was 95.5%; the 5-year failure-free fraction was 89.3%. In the 1-step group the 2-year and 5-year failure-free fractions were 95.9% and 86.9%, respectively, in the 2-step group 95.0% and 91.3% (log rank test P=.57). A total of 27 implants were lost during the entire follow-up: 14 in 6 patients of the 1-stage and 13 in 9 patients of the 2-stage group. The mean loss of alveolar bone after augmentation in the canine and molar regions was almost equal in both groups (overall means for the 2 regions 3.67 +/- 2.77 and 4.42 +/- 2.72 mm, respectively). The relationship between the jaws and thereby the esthetic profile could be improved in all cases. All patients were satisfied with the dental rehabilitation and the achieved new esthetic appearance. CONCLUSIONS: HLFO combined with iliac bone grafting is a feasible preprosthetic technique prior to implant insertion in cases of severe atrophy of the maxillary alveolar ridge, leading to satisfying implant survival and rehabilitation of function.

Adult↗

Long-term implant survival in the grafted maxilla: results of a 12-year retrospective study.

OBJECTIVE: The aim of this study was to determine the long-term outcome of implant insertion in the augmented severely atrophied maxilla. STUDY DESIGN: Three hundred and twenty-four implants were inserted in 35 patients (eight males, 27 females, average age 57.6 years) in extremely atrophied maxillae after osteotomy and interposition of iliac crest bone. One hundred implants were installed in 12 patients simultaneously with the osteotomy and grafting; 224 implants were placed in 23 patients in a second procedure 6-12 months later. Implant parameters like osseointegration and peri-implant bone loss; peri-implant tissue parameters like bleeding, gingival and plaque index; and patients' satisfaction were evaluated. RESULTS: Of 324 implants, 29 (8.9%) were lost during the entire follow-up: 14 in six patients of the one-step and 15 in 11 patients of the two-step group. The overall input-output survival in 141.1 months was 91.1%. The overall 2-year failure-free fraction of implants was 95.5%; the 5-year failure-free fraction was 89.3%. In the one-step group, the 2 (5)-year failure-free fraction was 95.9% (86.9%), and in the two-step group 95% (91.3%) (log-rank test P=0.57). Marginal peri-implant bone loss was 1.7+/-1.3 mm mesial and 1.8+/-1.3 mm distal. CONCLUSION: Implant insertion after osteotomy and iliac bone grafting is a reliable operation method for the dental rehabilitation of the severely atrophied maxilla showing good long-term results.

Atrophy↗

Molecular monitoring of adenovirus in peripheral blood after allogeneic bone marrow transplantation permits early diagnosis of disseminated disease.

Adenovirus (AdV) infection in the course of allogeneic stem cell transplantation (SCT) is associated with high transplant-related morbidity and mortality. Disseminated AdV disease is lethal in most instances. Early detection of AdV infection and identification of patients carrying a high risk of disseminated disease therefore remain a major challenge. In view of the large number of existing AdV types, we have established real-time polymerase chain reaction (PCR) assays permitting sensitive detection and quantification of all 51 currently known human AdV serotypes. In a series of 132 consecutive pediatric patients undergoing SCT, more than 5000 samples derived from peripheral blood (PB), stool, urine, and throat were screened for adenovirus infection by PCR during the posttransplantation period. Thirty-six patients (27%) tested positive by PCR, revealing AdV types of the subgenera A, B, C, D, and F. Except for enteritis in some patients with AdV positivity in stool, detection of the virus at sites other than PB was not associated with clinical signs of virus disease, and transplant-related mortality was not significantly different from AdV-negative patients. By contrast, 82% of patients who had detectable AdV in PB died from infectious complications (P <.001). Monitoring of PB specimens by real-time PCR permitted early diagnosis of invasive AdV infection in all instances. In patients who developed disseminated AdV disease, detection of the virus in PB preceded onset of clinical symptoms by a median of more than 3 weeks. The observation of AdV in peripheral blood may therefore serve as a basis for early initiation of preemptive antiviral treatment.

Adenoviridae↗

Computer-enhanced stereoscopic vision in a head-mounted operating binocular.

Based on the Varioscope, a commercially available head-mounted operating binocular, we have developed the Varioscope AR, a see through head-mounted display (HMD) for augmented reality visualization that seamlessly fits into the infrastructure of a surgical navigation system. We have assessed the extent to which stereoscopic visualization improves target localization in computer-aided surgery in a phantom study. In order to quantify the depth perception of a user aiming at a given target, we have designed a phantom simulating typical clinical situations in skull base surgery. Sixteen steel spheres were fixed at the base of a bony skull, and several typical craniotomies were applied. After having taken CT scans, the skull was filled with opaque jelly in order to simulate brain tissue. The positions of the spheres were registered using VISIT, a system for computer-aided surgical navigation. Then attempts were made to locate the steel spheres with a bayonet probe through the craniotomies using VISIT and the Varioscope AR as a stereoscopic display device. Localization of targets 4 mm in diameter using stereoscopic vision and additional visual cues indicating target proximity had a success rate (defined as a first-trial hit rate) of 87.5%. Using monoscopic vision and target proximity indication, the success rate was found to be 66.6%. Omission of visual hints on reaching a target yielded a success rate of 79.2% in the stereo case and 56.25% with monoscopic vision. Time requirements for localizing all 16 targets ranged from 7.5 min (stereo, with proximity cues) to 10 min (mono, without proximity cues). Navigation error is primarily governed by the accuracy of registration in the navigation system, whereas the HMD does not appear to influence localization significantly. We conclude that stereo vision is a valuable tool in augmented reality guided interventions.

Depth Perception↗

Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible.

The overall accuracy of a novel surgical computer-aided navigation system for placement of endosseous implants was evaluated. Five dry cadaver mandibles were scanned using high resolution computed tomography (HRCT). The position of four interforaminal dental implants was planned on the computer screen and transferred to the cadaver mandibles using VISIT, a surgical navigation software developed at the Vienna General Hospital. The specimens were HRCT-scanned again to compare the position of the implants with the preoperative plan on reformatted slices after matching of the pre- and postoperative data sets using the mutual information technique. The overall accuracy was 0.96 +/- 0.72 mm (range 0.0-3.5 mm). No perforation of the mandibular cortex or damage to the mandibular canal occurred. We conclude that computer-aided implant surgery can reach a level of accuracy where further clinical developments are feasible.

Cadaver↗

Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery.

We developed a head-mounted display (HMD) with integrated computer-generated stereoscopic projection of target structures and integrated it into visit, a specific oral implant planning and navigation software. The HMD is equipped with two miniature computer monitors that project computer-generated graphics stereoscopically into the optical path. Its position is tracked by the navigation system's optical tracker and target structures are displayed in their true position over the operation site. In order to test this system's accuracy and spatial perception of the viewer, five interforaminal implants in three dry human mandibles were planned with visit and executed using the stereoscopic projection through the HMD. The deviation between planned and achieved position of the implants was measured on corresponding computed tomography (CT) scan images recorded post-operatively. The deviation between planned and achieved implant position at the jaw crest was 0.57 +/- 0.49 mm measured from the lingual, and 0.58 +/- 0.4 mm measured from the buccal cortex. At the tip of the implants the deviation was 0.77 +/- 0.63 mm at the lingual and 0.79 +/- 0.71 mm at the buccal cortex. The mean angular deviation between planned and executed implant position was 3.55 +/- 2.07 degrees. The present in vitro experiment indicates that the concept of preoperative planning and transfer to the operative field by an HMD allows us to achieve an average precision within 1 mm (range up to 3 mm) of the implant position and within 3 degrees deviation for the implant inclination (range up to 10 degrees ). Control during the drilling procedure is significantly improved by stereoscopic vision through the HMD resulting in a more accurate inclination of the implants.

Computer Graphics↗