PubMed Health⌕ Search

Biomedical subjects

Franz Watzinger

Publications and source records attributed to Franz Watzinger.

21 records · Page 2Linked to original sources

Fixation of mandibular fractures with biodegradable plates and screws.

OBJECTIVE: Little data exist regarding the use of biodegradable plates and screws for the internal fixation of human mandibular fractures. The purpose of this study was to evaluate the stability of biodegradable, self-reinforced poly-L-lactide plates and screws for the internal fixation of fractures of the human mandible. STUDY DESIGN: Twenty-two individuals (14 male, 8 female; average age, 26.3 years) with a variety of fracture patterns of the mandible underwent management with a biodegradable fixation system. After surgery, maxillomandibular fixation was applied in 3 cases. Images (panoramic radiograph, computed tomographic scan) were taken immediately after surgery and at the 4-week, 8-week, 12-week, and 24-week intervals. The follow-up period averaged 49.1 weeks (range, 22 to 78 weeks). RESULTS: Mucosal dehiscences over the resorbable devices were present in 2 patients. In 1 of these 2 cases, the material had to be replaced with titanium plates. Mucosal healing and consolidation of the fracture were normal in all other patients. CONCLUSION: Self-reinforced biodegradable osteosynthesis materials provide a reliable and sufficient alternative to conventional titanium plate systems.

Absorbable Implants↗

A head-mounted operating binocular for augmented reality visualization in medicine--design and initial evaluation.

Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer-generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the realworld scene and the computer-generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost-effective head-mounted operating binocular, for AR. In this paper, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscope's computer displays to a real-world scene. In a series of 16 calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24 +/- 0.38 pixels or 0.12 +/- 0.05 mm for a 640 x 480 display. Maximum error accounted for 3.33 +/- 1.04 pixels or 0.33 +/- 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.

Calibration↗

Interactive stereotaxic teleassistance of remote experts during arthroscopic procedures.

This article describes the technical setup for stereotaxic telesurgical assistance for arthroscopic procedures. It also outlines the current state, limitations, and feasibility of this technical development. Teleassistance or teleconsultation implemented in endoscopic or arthroscopic procedures have not yet been reported. In this study, 7 computer-assisted arthroscopies of the temporomandibular joint were supported by extramural experts via interactive stereotaxic teleconsultation from distant locations. The external experts were supplied with close to real-time video, audio, and stereotaxic navigation data directly from the operation site. This setup allows the surgeons and external experts to interactively determine portals, target structures, and instrument positions relative to the patient's anatomy and to discuss any step of the procedures. Optoelectronic tracking interfaced to computer- based navigation technology allowed precise positioning of instruments for single or multiple temporomandibular joint punctures. The average error of digitizing probe measurements was 1.3 mm (range, 0.0 to 2.5 mm) and the average standard deviation was 0.7 mm (range, 0.4 to 0.9 mm). Evaluation of the reliability and accuracy of this technique suggests that it is sufficient for controlled navigation, even inside the small temporomandibular joint, a fact that encourages further applications for arthroscopy in general. The minimum requirement for high-quality video transmission for teleassisted procedures are integrated services digital network (ISDN) connections. Conventional ISDN-based videoconferencing can be combined with computer-aided intraoperative navigation. Transmission control protocol/internet protocol (TCP/IP)-based stereotaxic teleassistance data transmission via ATM or satellite seem to be promising techniques to considerably improve the field of arthroscopy.

Aged↗