Inadvertent insertion of an opposite-power intraocular lens.

An 82-year-old woman with age-related cataract and high myopia had uneventful phacoemulsification and intraocular lens (IOL) implantation. Preoperative visual acuity was 20/60 with -16.00 -3.00 x 70 and axial length was 29.29 mm. An IOL (MA60MA, Alcon) of +5.0 diopters (D) was selected with target refraction of -1.5 D. The next day, visual acuity was 20/15 with +5.50 -2.00 x 60. It was found that an IOL of -5.0 D was inadvertently inserted instead of +5.0 D because of an identical package appearance of the opposite-diopter IOLs except for a small negative sign before the diopter label. The -5.0 D IOL was surgically replaced with +5.0 D IOL, and visual acuity became 20/15 with -0.50 -2.00 x 70. When selecting an IOL for highly myopic patients, attention should be paid to the extreme resemblance of the package of opposite-diopter IOLs.

Aged, 80 and over↗

Optical quality of the cornea after overnight orthokeratology.

PURPOSE: To review changes in the optical quality of the cornea induced by overnight orthokeratology for myopia. METHODS: Sixty-four eyes of 39 patients who underwent overnight orthokeratology for myopia were prospectively examined. Inclusion criteria were uncorrected visual acuity of 20/20 or better after treatment and a minimum follow-up of 3 months. To quantitatively assess changes in corneal regular and irregular astigmatism, videokeratography data were decomposed into spherical component, regular astigmatism, asymmetry, and higher-order irregularity using Fourier analysis. In addition, corneal wavefront aberrations were calculated by expanding anterior corneal height data from videokeratography into a set of orthogonal Zernike polynomials. RESULTS: Although orthokeratology significantly reduced manifest refraction and improved uncorrected visual acuity, the asymmetry component, which is one of the features of irregular astigmatism, increased significantly from 0.35 +/- 0.22 to 0.64 +/- 0.40 D after treatment (P < 0.0001, paired t test). The increases in the asymmetry component significantly correlated with the amount of myopic correction (Pearson correlation coefficient, R = 0.40, P = 0.0009). Furthermore, the root-mean-square of third-order (coma-like) and fourth-order (spherical-like) aberrations significantly increased after orthokeratology (P < 0.0001, paired t test), and these increases showed significant positive correlations with the amount of myopic correction (Pearson correlation coefficient, R = 0.452, P = 0.0001 and R = 0.381, P = 0.0017, respectively). CONCLUSION: Corneal irregular astigmatism and higher-order aberrations significantly increased even in clinically successful orthokeratology, and the increases correlated with the magnitude of myopic correction. A large myopic correction by orthokeratology should be avoided to not decrease corneal optical quality.

Adolescent↗

Ciliary body edema after scleral buckling surgery for rhegmatogenous retinal detachment.

PURPOSE: Choroidal detachment and anterior chamber (AC) shallowing develop in some cases after scleral buckling surgery for rhegmatogenous retinal detachment (RD). Postoperative angle-closure glaucoma has been reported to occur in 4% of cases. It is supposed that compression by the local scleral buckling induces ciliary body edema and angle narrowing. This study aimed to evaluate quantitatively the time course of changes in ciliary body thickness and AC depth (ACD) before and after the scleral buckling procedure using ultrasound biomicroscopy. DESIGN: Prospective consecutive case series. PARTICIPANTS: Forty-six eyes of 44 patients (43.7+/-18.1 years old [mean +/- standard deviation]) undergoing rhegmatogenous RD surgery. METHODS: Ciliary body thickness and ACD were measured before and 3, 7, 14, and 28 days after the procedure. Ultrasound biomicroscopy was used to evaluate ACD and ciliary body thickness. MAIN OUTCOME MEASURE: Time course of changes in ciliary body thickness and ACD. RESULTS: The surgery caused significant increases in ciliary body thickness at 3, 7, and 14 days postoperatively (P<0.0001, Bonferroni multiple comparison). Ciliary body edema reached its peak 3 days after surgery, followed by a gradual decrease thereafter. Ciliary body thickness in the encircling group was statistically greater than in the segmental buckling group at 3 and 7 days postoperatively (P<0.001, Student's t test). The ciliary body was significantly thicker in the direction of buckling than on the opposite side 3 days after surgery (P = 0.0079). In the encircling group, retinal reattachment surgery significantly decreased ACD 3 days after surgery (P = 0.018), whereas no significant fluctuations were found in the buckling group. CONCLUSIONS: Even without apparent choroidal detachment and a shallow AC, subclinical ciliary edema existed in all directions of all eyes for at least 1 month after the scleral buckling procedure. The ciliary body in the direction of scleral buckling showed greater edema than the other areas. Eyes treated with the encircling band showed greater ciliary edema than those treated with segmental buckling alone.

Adult↗

Immunohistochemical localization of advanced glycation end products in pinguecula.

BACKGROUND: Advanced glycation end products (AGEs) are known to be deposited in the target organ of ageing. In addition, the deposition of AGEs accelerate the process of ageing. We investigated the immunohistochemical localization of AGEs in pinguecula, one of the ocular changes related with ageing process. METHODS: Surgical specimens of conjunctiva with or without pinguecula were prepared from nine patients, respectively. Immunohistochemical localization of AGEs was investigated using monoclonal antibodies to N(epsilon)-(carboxymethyl)lysine, pentosidine, imidazolone, and pyrraline. RESULTS: Moderate to strong immunoreactivities to AGEs were detected in the subepithelial amorphous deposits of all the surgical specimens with pinguecula. In contrast, no or weak immunoreactivities to AGEs were detected in the surgical specimens without pinguecula. CONCLUSIONS: Pinguecula is an aggregation of AGEs-modified proteins. The presence of pinguecula would be an index of local irradiation of ultraviolet rays and decreased antioxidant activities.

Adult↗

Corneal barrier function, tear film stability, and corneal sensation after photorefractive keratectomy and laser in situ keratomileusis.

PURPOSE: To compare corneal sensation, corneal barrier function, tear secretion, and tear film stability after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK). DESIGN: Prospective, nonrandomized clinical trial. METHODS: In a prospective study, 28 eyes of 15 patients underwent PRK and 115 eyes of 59 patients underwent LASIK to correct myopia. Corneal sensation, corneal epithelial barrier function, tear secretion, and tear film stability were examined preoperatively and 1 week and 1, 3, 6, and 12 months postsurgery. RESULTS: Both PRK and LASIK significantly compromised corneal sensation, increased epithelial barrier function, reduced tear secretion, and deteriorated tear film stability (P < .05, Wilcoxon signed-rank test). Deterioration of corneal sensation was significantly greater after LASIK than after PRK by 3 months postoperatively (P < .05, Wilcoxon rank sum test). Increases in corneal epithelial permeability were more prolonged after LASIK than after PRK. A significant intergroup difference in permeability was observed 1 month after surgery (P < .01). Tear breakup time was significantly shorter in the LASIK group than in the PRK group up to 3 months after surgery (P < .045). CONCLUSIONS: LASIK induces greater and more prolonged damage to corneal sensation, corneal barrier function, and tear film stability than PRK.

Adolescent↗

Corneal higher-order aberrations induced by overnight orthokeratology.

PURPOSE: To evaluate corneal higher-order aberrations induced by overnight orthokeratology for myopia. DESIGN: Prospective, noncomparative, consecutive, interventional case series. METHODS: A prospective study was conducted in 64 eyes of 39 patients with overnight orthokeratology for myopia, who were followed up for at least 3 months and attained uncorrected visual acuity of 20/20 or better. Corneal height data were obtained with computerized videokeratography (TMS-2N, Tomey), and wavefront aberration was derived using Zernike polynomials. Higher-order aberrations of the cornea were calculated for 3- and 6-mm pupils. RESULTS: Orthokeratology significantly reduced manifest refraction from -2.60 +/- 1.13 (mean +/- SD) diopters to -0.17 +/- 0.31 diopters (P < .0001, paired t test). Root-mean-square (RMS) of third-order (coma-like) aberrations significantly increased by orthokeratology for both 3-mm (P < .0001, paired t test) and 6-mm (P < .0001) pupils. Fourth-order RMS (spherical-like) aberrations increased significantly by the treatment for both 3-mm (P < .0001) and 6-mm (P < .0001) pupils. Vertical coma significantly changed from positive to negative for both 3-mm (P = .0323) and 6-mm (P < .0001) pupils. Horizontal coma significantly increased to the positive direction for both 3-mm (P < .0001) and 6-mm (P < .0001) pupils. Increases in the third- and fourth-order RMS showed significant positive correlations with the amount of myopic correction for 3-mm (Pearson correlation coefficient, r = .452, P = .0001 for third-order RMS, r = .381, P = .0017 for fourth-order RMS) and 6-mm (r = .499, P < .0001, r = .455, P = .0001) pupils. CONCLUSIONS: Corneal higher-order aberrations significantly increased, even in clinically successful orthokeratology cases. The increases in the higher-order aberrations correlated with the magnitude of myopic correction.

Adolescent↗

Clinical application of 11-deoxycortisol in visualizing prolapsed vitreous body after posterior capsule rupture in cataract surgery.

PURPOSE: To evaluate the clinical usefulness of 11-deoxycortisol, a precursor of cortisol in steroid metabolism, in visualizing the vitreous body in the anterior chamber after posterior capsule rupture during cataract surgery. SETTING: Department of Ophthalmology, Tsukuba University Hospital, Ibaraki, Japan. METHODS: Eight eyes had anterior vitrectomy during cataract surgery using this new technique. A suspension of 11-deoxycortisol was prepared by dilution in balanced salt solution without preservatives or emulsifying agents. After a posterior capsule rupture, the suspension was injected into the anterior chamber. The visual and anatomical outcomes of surgery were evaluated during a follow-up of 7 to 9 months. RESULTS: After the 11-deoxycortisol injection, the vitreous body that had prolapsed through the torn posterior capsule, with white particles entrapped on its surface, became clearly visible. Complete removal of the prolapsed vitreous body was achieved easily and safely using an anterior vitrectomy system. No postoperative complications related to the use of 11-deoxycortisol were observed. CONCLUSION: Injection of 11-deoxycortisol helped visualize the vitreous body in the anterior chamber after posterior capsule rupture. The technique minimized intraoperative and postoperative complications related to posterior capsule rupture and vitreous loss during cataract surgery [corrected]

Aged↗

Toxicological evaluation of micafungin ophthalmic solution in rabbit eyes.

There have been no reports of the topical application of micafungin to the eye. The aim of this study was to evaluate the safety of topical instillation of 0.1% micafungin ophthalmic solution in rabbit eyes. In New Zealand white rabbits (n = 6), 50 microL of 0.1% micafungin solution was topically instilled to 1 eye, and 50 microL of sterile saline was applied to the other eye. Both eyedrops were administered hourly from 7 A.M. for 7 days. Measurements were conducted on corneal thickness, intraocular pressure, endothelial cell density, and lactate dehydrogenase (LDH) activity of tear samples. The eyes were examined slit-lamp biomicroscopically and histopathologically. Topical micafungin application for 1 week did not induce any changes in intraocular pressure, endothelial cell density, and tear LDH. Corneal thickness after instillation was slightly, but significantly, smaller in the micafungin group than in the control group (P = 0.0156, paired t test), but this difference disappeared within 24 hours after the final instillation. Biomicroscopy and histopathology revealed no significant toxic influence of micafungin application on the cornea. Topical instillation of micafungin solution had no apparent toxicity to the cornea. These results warrant future studies on the efficacy of micafungin ophthalmic solution against corneal fungal infection.

Animals↗

Ultrasound biomicroscopic findings in aniridia.

PURPOSE: To describe the ultrasound biomicroscopic features of eyes with aniridia. DESIGN: Observational case series. METHODS: Nineteen eyes of 10 patients with aniridia (six males and four females) ranging in age from 3 months to 53 years (21.0 +/- 16.4, mean +/- SD), and 50 normal subjects (30 men and 20 women) ranging from 16 to 56 years (31.1 +/- 13.2) were evaluated. Ultrasound biomicroscopic findings were recorded in the 3-, 6-, 9-, and 12-o'clock directions. Adult patients (aged 16 years or older) with aniridia were compared with the age-matched controls. RESULTS: Ultrasound biomicroscopy (UBM) detected extremely tiny irises in all eyes with aniridia. The eyes with aniridia showed significantly smaller values than the controls in ciliary body length (4.49 +/- 0.63 versus 5.79 +/- 0.44 mm, P <.001, unpaired Student t test), ciliary body thickness (0.75 +/- 0.17 versus 1.24 +/- 0.22 mm, P <.001), iris root thickness (0.47 +/- 0.14 versus 0.61 +/- 0.07 mm, P <.001), scleral-ciliary process angle (31.7 +/- 3.26 versus 43.1 +/- 4.48 degree, P <.001), and anterior chamber depth (1.99 +/- 0.43 versus 2.94 +/- 0.34 mm, P <.001). In the aniridia eyes, there was a significantly positive correlation between iris thickness and ciliary body thickness (Pearson r = 0.829, P =.001). CONCLUSION: Ultrasound biomicroscopic imaging demonstrated that not only iris hypoplasia but also ciliary body hypoplasia exist in aniridia. Anterior inclination of the ciliary process was also found, which was thought to be at least partly responsible for the shallow anterior chamber.

Adolescent↗

Quantitative evaluation of regular and irregular corneal astigmatism in patients having overnight orthokeratology.

PURPOSE: To quantitatively assess changes in regular and irregular corneal astigmatism in patients having overnight orthokeratology. SETTING: Matsumoto Eye Clinic, Ibaraki, Japan. METHODS: A prospective study was conducted of 64 eyes of 39 patients having overnight orthokeratology for myopia. Inclusion criteria were an uncorrected visual acuity (UCVA) of 20/20 or better after treatment and a minimum follow-up of 3 months. Using Fourier series harmonic analysis, videokeratography data were decomposed into spherical component, regular astigmatism, asymmetry (tilt or decentration), and higher-order irregularity. RESULTS: Orthokeratology significantly reduced the manifest refraction from -2.60 diopters (D) +/- 1.13 (SD) to -0.17 +/- 0.31 D (P<.0001, paired t test) and improved the UCVA from 0.82 +/- 0.30 to -0.11 +/- 0.06 logMAR (P<.0001). Regular astigmatism increased significantly from 0.53 +/- 0.23 D preoperatively to 0.63 +/- 0.40 D postoperatively (P =.0206). The asymmetry component increased significantly from 0.35 +/- 0.22 D to 0.64 +/- 0.40 D (P<.0001). Higher-order irregularity did not change significantly: 0.14 +/- 0.11 D before treatment and 0.17 +/- 0.20 D after treatment (P =.2166). The amount of myopic correction correlated significantly with the increase in the asymmetry component (Pearson correlation coefficient, R = 0.40, P =.0009) but not with the increase in regular astigmatism (R = 0.24, P =.055). CONCLUSIONS: Irregular corneal astigmatism significantly increased, even in clinically successful orthokeratology cases. The effect of the changes on visual function should be studied further.

Adolescent↗

Visualizing the vitreous body in the anterior chamber using 11-deoxycortisol after posterior capsule rupture in an animal model.

OBJECTIVE: To develop a new technique to visualize vitreous body prolapsed in the anterior chamber using 11-deoxycortisol. STUDY DESIGN: Experimental study. METHODS: An animal model of posterior capsule rupture was developed to investigate the usefulness of 11-deoxycortisol, a precursor of cortisol without steroid activity. After the intentional creation of posterior capsule rupture, the suspension of 11-deoxycortisol was injected into the anterior chamber of rabbit eyes. After gentle irrigation and aspiration, the vitreous body that had prolapsed into the anterior chamber was removed using an anterior vitrectomy cutter. To investigate the safety of 11-deoxycortisol, the biomicroscopic appearance, intraocular pressure (IOP), corneal endothelial count, and microstructure of the corneal endothelium were examined in the rabbits that received injections of 11-deoxycortisol in the anterior chamber. RESULTS: In our posterior capsule rupture model, the vitreous in the anterior chamber became clearly visible, with 11-deoxycortisol showing white particles entrapped on its surface. The injection of 11-deoxycortisol facilitated the complete removal of the vitreous body from the anterior chamber. In intact rabbit eyes, most of the injected 11-deoxycortisol had disappeared from the anterior chamber by 12 hours after injection. The injection of 11-deoxycortisol had no effect on IOP, corneal endothelial density, or the microstructure of the corneal endothelium. CONCLUSIONS: The injection of 11-deoxycortisol in the anterior chamber is useful in visualizing the vitreous body and has no significant side effects. This technique might reduce the intraoperative and postoperative complications of anterior vitrectomy after posterior capsule rupture.

Animals↗

Corneal iron ring formation associated with overnight orthokeratology.

PURPOSE: To describe a case of iron deposition in both eyes after overnight orthokeratology. METHODS: This is a case report of a 31-year-old man who underwent overnight orthokeratology. The subject was fitted with rigid gas-permeable contact lenses of reverse-geometry design to correct myopia. RESULTS: The prefitting manifest refraction was -4.75 -0.25 x 175 in the right eye and -4.50 -0.25 x 175 in the left eye. There was no corneal abnormality until 9 months after treatment, but development of corneal arcuate lines in both eyes was observed at the 1-year follow-up visit. Visual acuity was not affected. The deposition pattern corresponded to the outside border of central flatter zone, as shown on the corneal topography map. CONCLUSION: The current findings suggest that tear pooling between the corneal surface and the back surface of the contact lens plays a role in the development of corneal iron ring after orthokeratology with reverse-geometry contact lenses.

Adult↗

Influence of overnight orthokeratology on corneal endothelium.

PURPOSE: To evaluate the influence of overnight orthokeratology on the corneal endothelium. METHODS: Fifty-two eyes of 31 patients undergoing overnight orthokeratology for myopia were examined. They wore the lens every night and were followed up for at least 1 year. The corneal endothelium was examined with specular microscopy to calculate mean endothelial cell density, coefficient of variation of cell area, and percentage of hexagonal cells. Data obtained at 1-year follow-up examinations were compared with those at the baseline examinations using a paired t test. RESULTS: Orthokeratology significantly reduced manifest refraction from -2.32 +/- 1.18 D (mean +/- standard deviation) to -0.16 +/- 0.33 D (P < 0.0001) and improved uncorrected visual acuity from 0.77 +/- 0.29 to -0.07 +/- 0.10 logMAR (P < 0.0001). The endothelial cell density did not change significantly (2879 +/- 231 cells/mm before and 2864 +/- 260 cells/mm after treatment, P = 0.252). The coefficient of variation of cell area was 22.3 +/- 2.7 at baseline and 22.1 +/- 2.4 at 1-year posttreatment, which did not change significantly (P = 0.537). The percentage of hexagonal cells was 72.8 +/- 10.2% pretreatment and 72.5 +/- 10.9% posttreatment (P = 0.800). CONCLUSIONS: Overnight orthokeratology for 1 year did not influence the density or morphology of corneal endothelial cells.

Adolescent↗

Long-term changes in rabbit cornea after ionizing radiation.

PURPOSE: To investigate long-term changes in the cornea after ionizing irradiation in rabbits. METHODS: Mature albino rabbits (n = 4) were unilaterally irradiated with 20 Gy of x-rays. The contralateral eye served as a control. The rabbits were examined with slit-lamp biomicroscopy for 5 years. The eyes were then enucleated for histopathologic examinations with light microscopy and transmission electron microscopy. RESULTS: On biomicroscopy, there was no corneal abnormality during the 5-year follow-up period. On histopathology, no abnormality was observed in the corneal epithelium. In the endothelium, a vacuole-like structure was recognized by light microscopy, and transmission electron microscopy revealed marked enlargement of intercellular space and anamorphosis of the nuclei. CONCLUSION: Moderate x-ray irradiation to rabbit eye did not induce any long-term damage to the corneal epithelium, but the endothelium demonstrated persistent and irreversible damage, which was observed even 5 years after irradiation.

Animals↗

Ocular higher-order aberrations and contrast sensitivity after conventional laser in situ keratomileusis.

PURPOSE: To investigate prospectively the relation between induced changes in higher-order aberrations of the eye and changes in contrast sensitivity by conventional laser in situ keratomileusis (LASIK) for myopia. METHODS: In 200 eyes of 110 consecutive patients (mean age, 32.7 +/- 8.4 years) undergoing LASIK, ocular aberrations and contrast sensitivity function were determined before and 1 month after surgery. The amount of myopic correction was 5.2 +/- 2.8 D (range, 1.0-13.0). Ocular higher-order aberrations were measured for a 4-mm pupil using the Hartmann-Shack wavefront analyzer (KR-9000PW; Topcon, Tokyo, Japan). The root mean square (RMS) of the third- and fourth-order Zernike coefficients was used to represent coma- and spherical-like aberrations, respectively. Total higher-order aberrations were calculated as the RMS of the third- and fourth-order coefficients. Contrast sensitivity and low-contrast visual acuity were measured. From the contrast sensitivity data, the area under the log contrast sensitivity function (AULCSF) was calculated. RESULTS: LASIK significantly improved logMAR best corrected visual acuity (Wilcoxon signed-rank test, P <0.001), but significantly reduced AULCSF (P <0.001) and low-contrast visual acuity (P=0.007). Total higher-order (P <0.001), coma-like (P <0.001), and spherical-like (P <0.001) aberrations were significantly increased after LASIK. The greater the amount of achieved myopia correction was, the more the changes in contrast sensitivity function and ocular higher-order aberrations were. The induced changes in AULCSF by LASIK showed significant correlations with changes in total higher-order (Pearson r=-0.221, P=0.003), coma-like (r=-0.205, P=0.006), and spherical-like (r=-0.171, P=0.022) aberrations. The changes in logMAR low-contrast visual acuity by surgery significantly correlated with changes in total higher-order (r=0.222, P=0.003), coma-like (r=0.201, P=0.007), and spherical-like (r=0.207, P=0.005) aberrations. CONCLUSIONS: Conventional LASIK significantly increases ocular higher-order aberrations, which compromise the postoperative contrast sensitivity function.

Adolescent↗

A case of angle closure glaucoma caused by plateau iris and adie's pupil.

PURPOSE: To describe a case of plateau iris associated with bilateral Adie's pupil. DESIGN: Interventional case report. METHODS: A 54-year-old woman presented with pain in her right eye and headache. Intraocular pressure was 34 mm Hg in the right eye. Light reflex was defective bilaterally. RESULTS: Ultrasound biomicroscopic imaging revealed normal anterior chamber depth and narrow angle. The ciliary processes were situated anteriorly. The eyes showed supersensitivity to 0.125% pilocarpine. The patient was diagnosed as having bilateral angle-closure glaucoma induced by Adie's pupil and plateau iris. CONCLUSION: Mild pupillary dilation caused by Adie's pupil may have played a role in the development of angle closure in the plateau iris configuration of our patient.

Anterior Chamber↗

Measurement of axial length of eyes with incomplete filling of silicone oil in the vitreous cavity using x ray computed tomography.

AIMS: To establish a reliable method for measuring the axial length of the eye with incomplete filling of silicone oil in the vitreous cavity in order to determine the IOL power before executing combined cataract surgery and silicone oil removal. METHODS: 12 eyes of 12 patients undergoing combined cataract extraction and silicone oil removal between October 1998 and June 2000 were entered prospectively into this study. All eyes were examined using an x ray computed tomography (CT) scanner. Each axial length of a silicone oil injected eye was measured on the best CT slice among eyeball cuts, which showed both the insertions of the medial and lateral rectus muscle, the thickest slice of the lens, and the optic nerve. The IOL power for the eyes was determined using the SRK/T formula based on the CT data. The deviation of postoperative refraction from the goal refraction was evaluated for each eye. RESULTS: The CT slices demonstrated that the vitreous cavity was not completely filled with the oil in all of the silicone oil injected eyes. The deviation of postoperative refraction from the goal refraction was less than 1 dioptre (D) error in six of 12 eyes (50%), and was less than 2 D error in nine eyes (75%). In the other three eyes having more than 2 D error, the axial length was 27 mm or more. CONCLUSION: The CT measurement of axial eye length for determining IOL might be a useful method for evaluating silicone oil injected eyes before combined cataract surgery and silicone oil removal.

Adult↗

Ultrasound biomicroscopic findings of ciliary body malignant melanoma.

BACKGROUND: Malignant melanoma of the uveal tract occurs rarely in Asian populations, and melanoma of the ciliary body is extremely rare. We treated an Asian man with uveal melanoma, relying on ultrasound biomicroscopy (UBM) findings for diagnosis and evaluation of the tumor. CASE. A 65-year-old man with uveal melanoma was examined by slit-lamp microscopy, UBM, and magnetic resonance imaging (MRI), and histopathological examinations were performed as well. OBSERVATIONS: Slit-lamp examination and MRI gave rough images of the tumor, but the exact origin and margin of the mass could not be determined. UBM clearly characterized the tumor as a medium echoic solid mass with acoustic hollowing attached to the ciliary body by a thin stem. Ciliary body detachment at the pars plicata was also found by UBM. Histopathological examination confirmed that the tumor was an epithelioid cell malignant melanoma of the ciliary body. CONCLUSIONS: UBM is useful in detecting, diagnosing, and evaluating a malignant melanoma of the ciliary body.

Aged↗