PubMed Health⌕ Search

Biomedical subjects

G A Krinsky

Publications and source records attributed to G A Krinsky.

At least 19 recordsLinked to original sources

Acquired aorta-pulmonary artery fistula: diagnosis by multiple imaging modalities.

Acquired communication between the aorta and the pulmonary artery is a rare phenomenon. We describe two patients with a thoracic aortic aneurysm in whom the diagnosis of a communication with the pulmonary artery was first made on transthoracic echocardiography and then more completely elucidated by means of multiple imaging modalities: transesophageal echocardiography, epiaortic ultrasound, computed tomography, and magnetic resonance imaging. Representative images from these complementary studies are presented. A successful repair of the fistula was subsequently accomplished in both patients.

Aged↗

MR renography with low-dose gadopentetate dimeglumine: feasibility.

PURPOSE: To develop a low-dose magnetic resonance (MR) renographic method performed with and without an angiotensin converting enzyme (ACE) inhibitor and in conjunction with gadolinium-enhanced MR angiography in patients with suspected renovascular disease. MATERIALS AND METHODS: Thirty-two patients underwent MR renography (turbo fast low-angle shot sequence: repetition time, 5 msec; echo time, 2.3 msec; flip angle, 15 degrees; one coronal image acquired every 2 seconds for 4 minutes) following intravenous injection of 2 mL of gadopentetate dimeglumine, which was repeated following intravenous injection of an ACE inhibitor. Contrast material-enhanced MR angiography was also performed. On the basis of renographic findings, renal cortex and renal medulla enhancement curves and normalized enhancement ratios were analyzed. RESULTS: The cortex and medulla showed an early transient period of enhancement within 20 seconds (vascular phase). During 1-2 minutes, a second, gradual increase in medullary enhancement, reflecting transit of filtered contrast material, was observed that was significantly greater in patients with a serum creatinine level less than 2 mg/dL (177 micromol/L) than in those with a level of 2 mg/dL or greater (P < .01). After injection of the ACE inhibitor, patients with elevated creatinine levels showed low renal medullary enhancement regardless of the presence of renal artery stenosis (RAS). However, in patients with creatinine less than 2 mg/dL, medullary enhancement ratios after injection of the ACE inhibitor were consistently lower in patients with RAS of 50% or greater than in those without stenosis (P = .02 to .08). CONCLUSION: Low-dose MR renography can be performed in the clinical setting before and after injection of an ACE inhibitor, and its potential use for evaluating decreased renal function as a consequence of RAS is promising.

Angiotensin-Converting Enzyme Inhibitors↗

Siderotic nodules in the cirrhotic liver at MR imaging with explant correlation: no increased frequency of dysplastic nodules and hepatocellular carcinoma.

PURPOSE: To determine the sensitivity of magnetic resonance (MR) imaging for detection of siderotic nodules in patients with cirrhosis and whether the frequency of hepatocellular carcinoma (HCC) and dysplastic nodules is greater if siderotic nodules are present. MATERIALS AND METHODS: MR imaging (1.5 T) was performed within 0-117 days (mean, 30 days) before liver transplantation in 77 patients. Two readers retrospectively evaluated gradient-echo (GRE) (echo time [TE], > or = 9 and 4-5 msec) and turbo short inversion time inversion-recovery or T2-weighted images for low-signal-intensity nodules. Whole-explant pathologic correlation was available in every case. RESULTS: At explantation, 28 (36%) of 77 patients had HCC, 25 (32%) had dysplastic nodules, and nine (12%) had both; 35 (45%) patients had siderotic nodules. The sensitivity of GRE imaging with 9-msec or longer TE for the detection of siderotic nodules was 80% (28 of 35) but decreased to 31% (11 of 35) with 4-5-msec TE. Frequency of HCC was not significantly higher (P =.27) in patients with (43% [15 of 35]) than in patients without (31% [13 of 42]) siderotic nodules. Frequency of dysplastic nodules also was not significantly higher (P =.42) in patients with (37% [13 of 35]) than in patients without (29% [12 of 42]) siderotic nodules. CONCLUSION: Sensitivity of MR imaging for the detection of siderotic nodules was improved with use of GRE pulse sequences with longer TEs of 9 msec or greater (80%) versus 4-5 msec (31%); however, there was no significant increased frequency of HCC or dysplastic nodules in patients with pathologically proved siderotic nodules.

Adult↗

Dynamic contrast-enhanced three-dimensional MR imaging of liver parenchyma: source images and angiographic reconstructions to define hepatic arterial anatomy.

PURPOSE: To assess the accuracy of an interpolated breath-hold T1-weighted three-dimensional (3D) gradient-echo (GRE) magnetic resonance (MR) imaging sequence with near-isotropic pixel size (</=2.3 mm) for evaluation of hepatic arterial anatomy variants during dynamic liver parenchymal imaging and to report patterns of hepatic arterial anatomy. MATERIALS AND METHODS: Liver MR imaging, including an interpolated breath-hold 3D GRE sequence with fat suppression (4.2/1.8 [repetition time msec/echo time msec], 12 degrees flip angle), was performed in 207 consecutive patients before and after gadopentetate dimeglumine administration. Of the 207 patients, 202 (98%) had technically satisfactory studies clearly defining the hepatic arterial system. The first contrast material-enhanced GRE acquisition was timed for optimal arterial enhancement with a timing examination. In a retrospective review, hepatic arteries were evaluated on the basis of arterial phase images interpreted by two independent readers using transverse source images complemented by multiplanar reconstructions. Twenty-three patients also underwent digital subtraction angiography, which was a reference standard for comparison. RESULTS: Conventional hepatic arterial anatomy was demonstrated in 135 (67%) of 202 patients. In the 23 patients with angiographic correlation, no discrepancy was noted between MR imaging and digital subtraction angiographic findings. CONCLUSION: Hepatic arterial anatomy can be reliably demonstrated during liver parenchymal imaging with an optimally timed contrast-enhanced isotropic 3D GRE sequence.

Angiography, Digital Subtraction↗

Hepatocellular carcinoma and dysplastic nodules in patients with cirrhosis: prospective diagnosis with MR imaging and explantation correlation.

PURPOSE: To determine the sensitivity and specificity of magnetic resonance (MR) imaging for detection of hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) by using explantation correlation in patients with cirrhosis and no known HCC. MATERIALS AND METHODS: Seventy-one patients without a known history of HCC who underwent MR imaging and subsequent transplantation within 90 days were examined. Breath-hold turbo short inversion time inversion-recovery and/or T2-weighted turbo spin-echo MR images were obtained. Dynamic two- or three-dimensional gadolinium-enhanced gradient-echo MR images were obtained in the hepatic arterial, portal venous, and equilibrium phases. Prospective MR image interpretations were compared directly with explanted liver pathologic results. RESULTS: Eleven (15%) of 71 patients had hepatic malignancies; MR imaging enabled diagnosis of tumor in six (54%) of 11 patients. On a lesion-by-lesion basis, MR imaging depicted 11 of 20 hepatic neoplasms, for an overall sensitivity of 55%. MR imaging depicted four (80%) of five lesions larger than 2 cm, six (50%) of 12 lesions 1-2 cm, and one (33%) of three lesions smaller than 1 cm. MR imaging depicted only nine (15%) of 59 DNS: The specificities of MR imaging for detection of HCC and DNs on a per patient basis were 60 (86%) of 70 patients and 53 (85%) of 62 patients, respectively. CONCLUSION: MR imaging is insensitive for the diagnosis of small (<2-cm) HCCs and DNS:

Adult↗

MR imaging as the sole preoperative imaging modality for right hepatectomy: a prospective study of living adult-to-adult liver donor candidates.

OBJECTIVE: Our aim was to investigate the feasibility of MR imaging as a comprehensive preoperative imaging test for examination of liver donor candidates for adult-to-adult right lobe transplantation. SUBJECTS AND METHODS: Twenty-five consecutive donor candidates were examined at 1.5 T using a torso phased array coil with breath-hold T1- and T2-weighted imaging of the abdomen, MR cholangiography using T2-weighted turbo spin-echo imaging, and MR angiography and venography of the liver using two interpolated three-dimensional spoiled gradient-echo sequences (average dose of gadolinium contrast material, 0.17 mmol/kg). Images were interpreted for liver parenchymal and extrahepatic abnormalities; measurements of right and left lobe liver volumes; definition of hepatic arterial, portal venous, and hepatic venous anatomy; and definition of the biliary branching pattern. Findings were compared with those of conventional angiography in 13 patients, 11 of whom also had surgical findings for comparison. RESULTS: Nine patients were excluded as candidates for donation on the basis of MR imaging findings that included parenchymal or extrahepatic abnormalities in five patients, vascular anomalies in two, and biliary anomalies in three. Two patients who did not undergo surgery underwent conventional angiography that confirmed MR angiographic findings except for a small (<2 mm) accessory left hepatic artery missed on MR imaging. Of the nine patients who underwent successful right hepatectomy, all MR imaging findings were corroborated intraoperatively. In two patients, right hepatectomy was aborted at laparotomy because of intraoperative cholangiography findings; in one of them, the biliary finding was unsuspected on MR imaging. CONCLUSION: A comprehensive MR imaging examination has the potential to serve as the sole preoperative imaging modality for living adult-to-adult liver donor candidates provided improvements in definition of intrahepatic biliary anatomy can be achieved.

Adult↗

Vascular and extravascular complications of liver transplantation: comprehensive evaluation with three-dimensional contrast-enhanced volumetric MR imaging and MR cholangiopancreatography.

OBJECTIVE: Our purpose was to evaluate a comprehensive MR imaging strategy for recipients of liver transplants that relies on dynamic interpolated three-dimensional (3D) MR imaging for simultaneous vascular, parenchymal, and extrahepatic imaging. MATERIALS AND METHODS: Twenty-three consecutive adult patients underwent 30 MR imaging examinations between 2 days and 99 months (mean, 15 months) after transplantation using a breath-hold 3D gradient-echo sequence (TR range/TE range, 3.7-4.7/1.8-1.9; flip angle, 12-30 degrees ) with an intermittent fat-saturation pulse and interpolation in the section-select direction to enable pixel size 3 mm or less in all dimensions. Unenhanced and triphasic contrast-enhanced 3D imaging (average dose, 0.13 mmol/kg of gadopentetate dimeglumine) was performed. A subset of patients (n = 13) also underwent MR cholangiopancreatography using half-Fourier single-shot turbo spin-echo imaging. MR imaging examinations were correlated with digital subtraction angiography (n = 8), contrast-enhanced cholangiography (n = 9), sonography (n = 13), and histopathology (n = 14). RESULTS: MR imaging revealed abnormal findings in 27 (90%) of 30 examinations, including vascular disease in nine, biliary complications in four, and evidence of intra- or extra-hepatic hepatocellular carcinoma recurrence in six. Digital subtraction angiography confirmed seven MR angiography examinations but suggested disease overestimation in one. Contrast-enhanced cholangiography confirmed findings of MR cholangiopancreatography in seven cases but suggested disease underestimation in two. CONCLUSION: Dynamic interpolated 3D MR imaging combined with dedicated MR cholangiopancreatography can provide a comprehensive assessment of vascular, biliary, parenchymal, and extrahepatic complications in most recipients of liver transplants.

Adult↗

Volumetric MR imaging of the liver and applications.

Recent improvements in MR technology have enabled the development of volumetric three-dimensional (3D) imaging methods for fat-suppressed T1-weighted images of the entire upper abdomen with pixel sizes of approximately 2 mm in all dimensions and with acquisition times of less than 25 seconds for breath-hold imaging. When performed with a timing scheme, dynamic contrast-enhanced volumetric imaging of the liver can be performed with selective imaging during the arterial phase and portal venous phase of enhancement. The volumetric data sets can be reconstructed in any oblique plane, enabling improved detection, localization, and characterization of small liver lesions. The combination of high-resolution isotropic pixels and accurate timing also permits angiographic reconstructions of the 3D images, producing MR angiography and venography that can be useful in therapeutic planning, such as for catheter-based interventions or surgical resections or transplantation. Additionally, with use of a hepatobiliary contrast agent such as mangafodipir, T1-weighted volumetric MR cholangiography can be performed in patients with nonobstructed systems for depiction of intrahepatic biliary anatomy.

Bile Ducts↗

Pelvic arteriovenous malformations: gadolinium-enhanced three-dimensional MR angiography findings.

Pelvic arteriovenous malformations (PAV-Ms) are rare disorders traditionally diagnosed by conventional angiography. Breath-hold three-dimensional gadolinium-enhanced MR angiography (3D-Gd-MRA) is a state-of-the-art alternative for vascular imaging. We describe the 3D-Gd-MRA findings in two patients with PAVMs. The 3D-Gd-MRA approach provides a noninvasive and versatile method for evaluation of PAVMs that enables both angiographic assessment of the malformations and evaluation of visceral involvement, which can preclude surgical intervention.

Adult↗

Diagnosis of a giant coronary aneurysm with multiple imaging modalities.

Echocardiography demonstrated an 8-cm mass adjacent to the right side of the heart in a 79-year-old man with a history of hypertension and a repaired abdominal aortic aneurysm. The results of Doppler echocardiography and magnetic resonance imaging suggested the diagnosis of an unusually large coronary artery aneurysm, and this was confirmed with coronary angiography. At surgery, the 8- to 10-cm coronary aneurysm was resected, and the patient made an uneventful recovery.

Aged↗

Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality.

PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination. MATERIALS AND METHODS: Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; interpolation in three directions; intermittent fat saturation; pixel size </= 2.5 mm in all dimensions) before and dynamically after administration of gadopentetate dimeglumine, with the first enhanced acquisition timed for hepatic arterial dominance by using a test bolus of contrast material. Qualitative and quantitative measures of image quality were determined. Patterns of arterial and venous anatomy were assessed. Ten patients (20%) underwent repeat imaging within 6 months, and reproducibility was evaluated. RESULTS: Hepatic contrast-to-noise ratios for nonenhanced and arterial, portal venous, and equilibrium phase studies averaged 13.0 +/- 12.6 (SD), 17.4 +/- 11.8, 30.4 +/- 16.2, and 28.6 +/- 21.1, respectively. During arterial phase, the liver enhanced a mean of 29% of the maximal enhancement as measured during portal venous phase. Hepatic vascular anatomic variants were comparable in distribution to those cited in published articles. Repeat studies were not significantly different in image quality when compared with original studies. CONCLUSION: High-quality arterial phase 3D volumetric interpolated breath-hold images can be obtained reliably and reproducibly when timed by using a test dose of contrast material.

Adipose Tissue↗

Angiotensin-converting enzyme inhibitor-enhanced phase-contrast MR imaging to measure renal artery velocity waveforms in patients with suspected renovascular hypertension.

OBJECTIVE: We investigated the usefulness of phase-contrast MR imaging to measure renal artery velocity waveforms as an adjunct to renal MR angiography. We also examined whether an angiotensin-converting enzyme (ACE) inhibitor improves the diagnostic accuracy of waveform analysis. SUBJECTS AND METHODS: Thirty-five patients referred for MR angiography of renal arteries underwent non-breath-hold oblique sagittal velocity-encoded phase-contrast MR imaging through both renal hila (TR/TE, 24/5; flip angle, 30 degrees; signal averages, two; encoding velocity, 75 cm/sec) before and after i.v. administration of an ACE inhibitor (enalaprilat). We analyzed velocity waveforms using established Doppler sonographic criteria. A timing examination with a test bolus of gadolinium contrast material was performed to ensure optimal arterial enhancement during breath-hold gadolinium-enhanced three-dimensional gradient-echo MR angiography. RESULTS: MR phase-contrast waveform pattern analysis was 50% (9/18) sensitive and 78% (40/51) specific for the detection of renal artery stenosis equal to or greater than 60% as shown on MR angiography. Sensitivity (67%, 12/18) and specificity (84%, 42/50) increased slightly, but not significantly, after i.v. administration of an ACE inhibitor. Also, the accuracy of quantitative criteria such as acceleration time and acceleration index did not improve after the administration of ACE inhibitor. CONCLUSION: Renal hilar velocity waveforms, measured using non-breath-hold MR phase-contrast techniques with or without an ACE inhibitor, are insufficiently accurate to use in predicting renal artery stenosis.

Adult↗

Echo-train STIR MRI of the liver: comparison of breath-hold and non-breath-hold imaging strategies.

The purpose of this study was to evaluate echo-train short inversion-time inversion recovery (STIR) sequences and compare the results obtained with breath-hold and non-breath-hold imaging strategies. Forty-one patients referred for hepatic magnetic resonance were imaged with both a breath-hold STIR (BH-STIR; acquisition time [TA] 16-20 seconds x 2) and a non-breath-hold STIR (NBH-STIR; TA 210-256 seconds). Quantitative analysis of the liver, spleen, and up to five hepatic lesions per patient was performed. Three blinded readers recorded the number of focal lesions depicted by each study and qualitatively evaluated overall image quality, lesion conspicuity, and image artifacts. The BH-STIR had greater sensitivity (98.8% vs. 91.6%) for detection of hepatic lesions than the NBH-STIR. The BH-STIR was statistically superior in four measures of image quality and had fewer image artifacts. The NBH-STIR images had statistically higher signal-to-noise (S/N, P < 0.001) and liver-lesion contrast-to-noise (C/N, P = 0.005) ratios. For the evaluation of focal hepatic lesions, a breath-hold echo-train STIR sequence provided superior overall image quality and allowed for detection of more lesions in a shorter amount of time than a non-breath-hold echo-train STIR sequence.

Artifacts↗

Atheromas of the thoracic aorta: A comparison of transesophageal echocardiography and breath-hold gadolinium-enhanced 3-dimensional magnetic resonance angiography.

Transesophageal echocardiography (TEE) has been the procedure of choice for identifying thoracic aortic atheromas. All patients over a 2-year period who underwent both TEE and magnetic resonance angiography of the thoracic aorta within 1 month were identified. The largest plaque in 3 aortic segments (ascending, arch, and descending) was measured. Thirty patients (16 men; 66.8 +/- 12.9 years) were studied. The mean size of the atheromas in the arch was larger as measured by TEE compared with magnetic resonance angiography (3.4 vs 1.4 mm, P =.01). However, the mean atheroma size was similar in the ascending aorta (1.9 vs 1.3 mm, P =.5) and descending aorta (3.9 vs 3.5 mm, P =.66). Of 24 aortic segments with plaques measuring >/=5 mm (with high embolic risk), 22 (92%) were seen on TEE and only 13 (54%) on magnetic resonance angiography (P =. 003). In conclusion, although both techniques are complementary, TEE does identify more high-risk plaques.

Aged↗

Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries.

PURPOSE: To evaluate the quality of single-dose breath-hold three-dimensional (3D) magnetic resonance (MR) angiography of the renal arteries optimized with a 1-mL test bolus timing examination. MATERIALS AND METHODS: Three-dimensional spoiled gradient-echo imaging (3.8-4.2/1.3-1.7 [repetition time msec/echo time msec], 25 degrees-40 degrees flip angle) was performed in 60 patients after administration of gadopentetate dimeglumine (average dose, 0.11 mmol/kg). Synchronization of contrast material administration with data acquisition was achieved with a 1-mL test dose of contrast material to estimate patient circulation parameters. Image quality was assessed by using contrast-to-noise (CNR), relative vascular enhancement, and venous-to-arterial enhancement ratios and subjective scoring of arterial and venous enhancement. The effect of the contrast material injection rate and the influence of breath holding during the timing examination also were examined. RESULTS: Overall, of 60 studies, 58 were diagnostic and 56 demonstrated excellent arterial enhancement. Venous enhancement was seen in eight studies. The average aortic relative vascular enhancement (+/- SD) was 14.6 +/- 5.9, with an aorta-to-inferior vena cava (IVC) CNR of 69.7 +/- 43.9. The IVC-to-aorta venous-to-arterial enhancement ratio averaged 0.08 +/- 0.16. There was no significant difference in image quality based on injection rates or the performance of breath holding during the timing examination (P > .1). CONCLUSION: Breath-hold gadolinium-enhanced renal MR angiography free of venous enhancement can be performed consistently and reliably with 20 mL of contrast material when studies are synchronized to patient circulation time by using a timing examination.

Contrast Media↗