PubMed Health⌕ Search

Biomedical subjects

G A Krinsky

Publications and source records attributed to G A Krinsky.

At least 37 records · Page 2Linked to original sources

Abdominal MR imaging with a volumetric interpolated breath-hold examination.

PURPOSE: To compare a T1-weighted, three-dimensional (3D), gradient-echo (GRE) sequence for magnetic resonance (MR) imaging of the body (volumetric interpolated breath-hold examination, or VIBE) with a two-dimensional (2D) GRE breath-hold equivalent. MATERIALS AND METHODS: Twenty consecutive patients underwent 1.5-T MR imaging. The examinations included pre- and postcontrast (20 mL gadopentetate dimeglumine) fat-saturated 2D GRE breath-hold imaging and fat-saturated volumetric interpolated breath-hold imaging before, during (arterial phase), and after injection, with thin (2-mm source images) and thick (8-mm reconstruction images) sections. The three images were compared qualitatively and quantitatively (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]). RESULTS: Qualitatively, the 2-mm source images had poorer pancreatic edge definition on precontrast images compared with the other two data sets (P < .05). On gadolinium-enhanced images, scores for clarity of pancreatic edge, number of vessels visualized, and arterial ghosting were significantly lower for the postcontrast 2D GRE images. Quantitatively, SNR measurements in the liver, aorta, and renal cortex on pre- and postcontrast images were significantly higher for the 8-mm reconstruction images than for the 2D GRE or 2-mm source images (P < .05). Aorta-to-fat CNR was significantly higher on the 8-mm reconstruction images. CONCLUSION: Fat-saturated volumetric interpolated breath-hold images have quality comparable to that of conventional fat-saturated 2D GRE images.

Abdomen↗

Thoracic aorta: rapid black-blood MR imaging with half-Fourier rapid acquisition with relaxation enhancement with or without electrocardiographic triggering.

PURPOSE: To evaluate and compare findings for thoracic aortic disease with three black-blood magnetic resonance (MR) pulse sequences: half-Fourier rapid acquisition with relaxation enhancement (RARE), with and without electrocardiographic (ECG) triggering, and ECG-triggered turbo spin echo (SE). MATERIALS AND METHODS: Axial black-blood MR images of the chest acquired at 1.5 T with a phased-array coil were obtained in 38 consecutive patients referred for evaluation of thoracic aortic disease. ECG-triggered and nontriggered half-Fourier RARE images were compared with T1-weighted ECG-triggered turbo SE images. Two readers independently scored images for each of the following parameters: ghosting artifacts; clarity of the mediastinum, cardiac chambers, and aortic wall; conspicuity of abnormality; intraluminal signal void uniformity; and overall image quality. RESULTS: Both half-Fourier RARE sequences outperformed the turbo SE sequence for all measured parameters. Scores for the ECG-triggered half-Fourier RARE sequence were significantly (P < .05) higher than those for the nontriggered version for clarity of the mediastinum and aortic wall, conspicuity of any abnormality other than aortic dissection, and overall image quality. Mean acquisition times for the ECG-triggered (48 seconds) and nontriggered (30 seconds) sequences were significantly shorter than that for the turbo SE sequence (2 minutes 20 seconds). CONCLUSION: Rapid black-blood half-Fourier RARE sequences, with or without ECG triggering, can replace ECG-triggered turbo SE sequences for evaluation of thoracic aortic disease.

Adult↗

Three-dimensional gadolinium-enhanced MR venographic evaluation of patency of central veins in the thorax: initial experience.

PURPOSE: To assess the usefulness of three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) venography for evaluation of thoracic central veins. MATERIALS AND METHODS: A retrospective study included 15 patients who underwent 3D gadolinium-enhanced subtraction MR venography with a spoiled gradient-echo sequence before and at multiple times after intravenous administration of 30-40 mL of contrast material. Maximum intensity projection and multiplanar reconstruction images were used to categorize central veins as patent, occluded, or narrowed. Results were compared with findings (in 12 patients) at conventional venography (n = 3), attempted central venous catheter placement (n = 3), or surgery (n = 6). Medical records were retrospectively reviewed to determine if patient care was affected by MR venographic findings. RESULTS: By using MR venograms, an appropriate vessel could be identified for successful placement of a catheter, indwelling venous access device, or arteriovenous hemodialysis graft in all nine patients in whom placement was attempted. MR venography also was predictive of unsuccessful hemodialysis catheter placement in one patient. Conventional venographic findings confirmed MR venographic findings in three patients; in a fourth patient, conventional venography was unsuccessful due to inadequate access. MR venographic findings influenced treatment in 14 patients. CONCLUSION: On the basis of these initial results, 3D gadolinium-enhanced MR venography may facilitate comprehensive evaluation of abnormalities of the central veins in the thorax, particularly with regard to selection of venous access sites.

Adult↗

Thoracic aorta: comparison of single-dose breath-hold and double-dose non-breath-hold gadolinium-enhanced three-dimensional MR angiography.

OBJECTIVE: The purpose of this study was to compare single-dose (0.1 mmol/kg) breath-hold gadolinium-enhanced three-dimensional (3D) MR angiography and double-dose (0.2 mmol/kg) non-breath-hold 3D MR angiography for evaluation of thoracic aortic disease. MATERIALS AND METHODS: Twenty-five patients referred for MR evaluation of the thoracic aorta underwent non-breath-hold gadolinium-enhanced 3D MR angiography on a 1.5-T scanner with standard gradients (TR/TE, 21/6; flip angle, 30 degrees) during slow infusion of a double dose of gadopentetate dimeglumine using a body coil. Subsequently, the same patients underwent breath-hold MR imaging with high-performance gradients (TR/TE, 5/2; flip angle, 30 degrees-50 degrees), a timing examination, and power injection of a single dose of gadolinium. For both studies, quantitative signal-to-noise measurements were obtained for the ascending thoracic, descending thoracic, and abdominal aorta. Three observers retrospectively evaluated each examination for degree of enhancement of the aorta, pulmonary arteries, and systemic veins; motion artifacts; and overall image quality. RESULTS: Single-dose breath-hold gadolinium-enhanced 3D MR angiography showed greater signal-to-noise ratio, fewer motion artifacts, and better overall image quality (p < .05) than the non-breath-hold double-dose technique. The single-dose technique also showed significantly better qualitative enhancement of the aortic root and ascending aorta (p < .05) and less enhancement of the pulmonary arteries, renal veins, and left internal jugular vein (p < .05). CONCLUSION: Optimized single-dose breath-hold gadolinium-enhanced 3D MR angiography is superior to double-dose non-breath-hold 3D MR angiography for evaluation of thoracic aortic disease.

Adolescent↗

Pulmonary nodule detection: low-dose versus conventional CT.

PURPOSE: To quantitate the effectiveness of low-dose computed tomography (CT) in the identification of pulmonary nodules while controlling for anatomic nodule characteristics and to establish what factors lead to reduced diagnostic sensitivity at low-dose CT. MATERIALS AND METHODS: Each of six participating radiologist independently rated 200 image panels by using a four-point confidence scale. Conventional images were obtained at 200 mAs; low-dose images were obtained at 20 mAs. To fully control their characteristics, nodules were simulated with a given diameter, shape, and section thickness while preserving the resolution, noise level, and reconstruction artifacts of the original images. Panels were matched so that nodules on low-dose and conventional images had equivalent sizes, locations, and relationships to blood vessels. RESULTS: Among 864 positive panels, 259 (60%) of 432 low-dose panels and 272 (63%) of 432 conventional panels were correctly interpreted (P = .259). Lowering the x-ray dose significantly reduced the detectability of peripheral nodules (P = .019) and nodules separated from blood vessels (P = .044). Surprisingly, 3-mm nodules were detected with approximately equal sensitivity (P = .181) at conventional and low-dose CT. The specificity of low-dose images was 88% (148 of 168 panels) versus 91% (153 of 168 panels) for conventional images (P = .372). CONCLUSION: Low-dose CT is acceptable for pulmonary nodule identification, making it suitable for primary screening. These results confirm the strong effect of size, location, and angiocentricity on the sensitivity of nodule detection with conventional CT.

Computer Simulation↗

Dysplastic nodules in cirrhotic liver: arterial phase enhancement at CT and MR imaging--a case report.

In a 65-year-old woman with cirrhosis, biphasic helical computed tomography (CT) and multiphase gadolinium-enhanced magnetic resonance (MR) imaging depicted 11 hepatic nodules that enhanced homogeneously during the hepatic arterial phase. At pathologic examination, all lesions were dysplastic nodules with unpaired hepatic arteries within. Hepatic arterial phase enhancement of cirrhotic nodules at CT and MR imaging is not diagnostic of hepatocellular carcinoma but may occur in dysplastic nodules. Results of a single biopsy yielding hepatocellular carcinoma may not be applicable to other nodules that enhance similarly.

Aged↗

Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging.

PURPOSE: To evaluate gadolinium-enhanced three-dimensional magnetic resonance (MR) angiography for thoracic aortic disease and to compare this technique with conventional thoracic MR imaging. MATERIALS AND METHODS: One hundred eight consecutive patients underwent 122 thoracic MR examinations, including conventional MR imaging followed by enhanced three-dimensional MR angiography. A gradient-echo sequence was used at 1.5 T (116 examinations) and 1.0 T (6 examinations) during infusion of 0.2 mmol/kg gadopentetate dimeglumine. Two independent readers (A and B), with varied experience in thoracic MR angiography, retrospectively evaluated the images for presence of aortic dissection, aneurysm, arch vessel disease, and protruding atheroma. Correlation with findings of surgery or other imaging modalities was available in 98 cases. RESULTS: Enhanced MR angiography was sensitive (92%-96%) and specific (100%) for acute and chronic aortic dissection (n = 26) and was as useful as conventional MR imaging in the diagnosis of aneurysm (n = 43) and arch vessel disease (n = 7). One of two intramural hematomas were overlooked at MR angiography by reader A, and both were overlooked by reader B. CONCLUSION: Enhanced three-dimensional MR angiography is a rapid and accurate imaging modality in diagnosis of thoracic aortic disease but is insensitive to intramural hematoma.

Adolescent↗

Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: optimization with a test examination and a power injector.

To optimize findings at dynamic gadolinium-enhanced hepatic magnetic resonance imaging in the hepatic arterial phase, a timing examination was performed after injection of a 0.5-mL timing bolus of gadopentetate dimeglumine. In the experimental group (n = 28), power injection was used and the imaging delay was determined in each patient on the basis of the results of the timing examination. In the control group (n = 28), hand injection and a fixed 20-second imaging delay were used. Arterial-phase examinations (defined as relative liver enhancement of not more than 30% of peak parenchymal enhancement) were successful in 26 (93%) experimental group patients and in 17 (61%) control group patients.

Adolescent↗

Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography.

PURPOSE: To demonstrate the utility of low-dose gadolinium-enhanced magnetic resonance (MR) angiography of two consecutive anatomic areas for assessment of peripheral vascular disease. MATERIALS AND METHODS: Fifteen patients underwent gadolinium-enhanced MR angiography for evaluation of lower extremity peripheral vascular disease after conventional digital subtraction angiography (DSA). MR angiography was performed with three-dimensional coronal gradient-echo acquisitions before and during administration of gadopentetate dimeglumine. Two separate, contiguous areas were studied with separate doses of 0.075 and 0.1 mmol/kg gadopentetate dimeglumine. MR angiography findings were compared with DSA findings; DSA was the standard of reference. Treatment options were determined first with MR angiograms and then with DSA images. RESULTS: For distinguishing greater than 50% stenosis from 50% or less stenosis, gadolinium-enhanced MR angiography yielded a sensitivity of 97%, a specificity of 96%, and an accuracy of 97%. In 146 (97%) of 150 anatomic segments, there was essential or total agreement on treatments determined with MR angiography and DSA. In two cases (one case of vascular stent placement and one case of surgical anastomosis), extent of disease was overestimated with MR angiography. The MR study of one infrapopliteal area was insufficient for evaluation. CONCLUSION: Accurate gadolinium-enhanced MR angiography of multiple peripheral vascular areas of the lower extremities can be performed in most patients with less than 0.2 mmol/kg contrast material.

Aged↗

Dysplastic nodules and hepatocellular carcinoma: thin-section MR imaging of explanted cirrhotic livers with pathologic correlation.

PURPOSE: To evaluate detection and characterization of hepatocellular nodules in fresh whole explanted cirrhotic livers at thin-section magnetic resonance (MR) imaging. MATERIALS AND METHODS: T1-weighted spin-echo and T2-weighted fast spin-echo MR imaging (5-mm-thick sections) were performed in a head coil at 1.5 T in the whole cirrhotic livers of 28 consecutive patients within 4 hours of explantation. MR imaging findings were correlated with findings at pathologic examination, and new international terminology was used to classify the hepatocellular nodules. RESULTS: At pathologic examination, 42 suspect (other than regenerative) nodules were identified in 11 patients. MR imaging depicted 41 of 42 (98%) of these nodules (five of five hepatocellular carcinomas [HCCs {diameter, > or = 2 cm}], 10 of 10 small HCCs [diameter, < 2 cm], two of two dysplastic nodules with subfoci of HCC, three of three high-grade dysplastic nodules, and 21 of 22 low-grade dysplastic nodules. Lesions demonstrated the following combinations of signal intensity characteristics on thin-section T1- and T2-weighted images, respectively: HCC, hyperintense, hypointense (n = 3); hyperintense, hyperintense (n = 1); hypointense, isointense (n = 1). Small HCC, hyperintense, hypointense (n = 7); hypointense, hyperintense (n = 2); hyperintense, hyperintense (n = 1). Both dysplastic nodules with subfoci of HCC, hyperintense, hypointense. All seven nonsiderotic low-grade dysplastic nodules, hyperintense, hypointense. All 14 siderotic low-grade dysplastic nodules, hypointense, hypointense. All three high-grade dysplastic nodules, hyperintense, hypointense. CONCLUSION: The variable signal intensity characteristics of HCCs made reliable diagnosis impossible, but the thinsection unenhanced in vitro MR images were sensitive for detection of HCCs and dysplastic nodules in cirrhotic livers.

Carcinoma, Hepatocellular↗

Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector.

PURPOSE: To determine the usefulness of a timing examination performed with 1 mL gadopentetate dimeglumine administered with a magnetic resonance (MR) power injector at single-dose three-dimensional (3D) MR aortography. MATERIALS AND METHODS: 3D fast imaging with steady-state precession (repetition time [msec]/echo time [msec] = 5.0/2.0, with 50 degrees flip angle) was performed in 30 patients after administration of 0.1 mmol/kg gadopentetate dimeglumine. In 15 inpatients, a power injector was used and a timing examination was performed (experimental group). In 15 outpatients, manual injection was used and a timing examination was not performed (control group). In the timing examination, 1 mL gadopentetate dimeglumine was followed with 15 mL saline, both at 2 mL/sec, during axial turbo fast low-angle shot imaging (11/4.2/300 [inversion time ¿msec¿], with a 15 degrees flip angle); one image was obtained every 2 seconds for 60 seconds. Aortic signal-to-noise ratios (S/Ns) and contrast-to-noise ratios (C/Ns) were determined on images obtained in the two groups. RESULTS: In the timing examinations, aortic S/N increased significantly (902% +/- 517 [P < .001]) and was sufficient to help determine the timing of arterial enhancement. Findings on experimental images were superior to those on control images (S/N, 29.8 vs 20.5 [P = .003]; C/N, 23.8 vs 12.8 [P < .001], respectively). The time to perform procedures and calculations at the timing examination added a mean of 4.5 minutes to each examination. CONCLUSION: The combined use of a power injector and a timing examination improved S/Ns and C/Ns at breath-hold single-dose gadolinium-enhanced 3D MR aortography.

Aged↗

Image subtraction in gadolinium-enhanced MR imaging.

Image subtraction in gadolinium-enhanced MR imaging is a broadly applicable postprocessing technique that can be used with any field strength and T1-weighted sequence. This technique is typically a quick and efficient means of obtaining fat suppression that avoids the limitations of incomplete fat saturation due to field inhomogeneity and increased imaging times associated with conventional fat-suppression techniques. In particular, image subtraction may be valuable on lower strength magnetic field systems that lack effective chemical-shift fat-suppression techniques. Because source data are viewed in conjunction with subtracted images, image subtraction is unlikely to introduce errors in interpretation. By performing unenhanced and enhanced sequences in a manner amenable to image subtraction, radiologists should find this technique to be a useful and almost cost-free option.

Aged↗

Small renal parenchymal neoplasms: further observations on growth.

PURPOSE: To determine the growTH rate and behavior of small (< or = 3.5-cm diameter) incidentally detected renal parenchymal neoplasms. MATERIALS AND METHODS: Forty renal parenchymal tumors in 37 adult patients (mean age, 65.5 years) were observed with computed tomography (CT) and ultrasound for 1.75-8.5 years (mean, 3.25 years). Surgical removal was performed of 26 tumors proved and graded at pathologic examination. Fourteen tumors with CT criteria of neoplasm are being followed up. RESULTS: The overall growth rate of neoplasms was 0-1.1 cm/y (mean, 0.36 cm/y). Thirty tumors grew 0.5 cm/y or less and 19 grew very slowly (< or = 0.35 cm/y). No patient developed metastatic disease. Nine (24%) had multiple neoplasms. CONCLUSION: Most small, incidentally discovered, well-marginated renal parenchymal neoplasms grow slowly and are not an immediate threat to a patient's life. Watchful waiting might be appropriate instead of surgical removal, especially in patients who are elderly or may not survive surgery.

Adenoma↗

Renal cell carcinoma: correlation of CT findings with nuclear morphologic grading in 100 tumors.

The contrast-enhanced preoperative computed tomographic (CT) scans and microscopic slides of 94 patients with 100 surgically resected renal cell carcinomas (RCCs) were retrospectively and independently reviewed in order to correlate the CT imaging findings of RCC with nuclear grading. As nuclear grade increased, RCCs were more likely to be of higher stage and greater size at presentation, and appeared more heterogeneous and less marginated. Of the features analyzed, tumor margination most closely correlated with nuclear grade. Overlap in the CT appearance of individual tumors limited the potential of CT to differentiate RCCs of varying grade. Small, well-marginated, homogeneous tumors, however, were either grade I or II, and were distinguishable from the more aggressive grade III lesions, which generally displayed irregular margins and greater inhomogeneity.

Adult↗