Transesophageal echocardiography (TEE) is the procedure of choice for identifying aortic atheromas, which may result in stroke, transient ischemic attack and peripheral embolization. However, because of anatomic constraints, the innominate artery may not be visualized. We investigated gadolinium-enhanced MR angiography (MRA) as an alternative technique for evaluation of suspected atheromas of the innominate artery. From a retrospective review of 520 examinations, we identified five patients who had innominate artery atheromas diagnosed prospectively with gadolinium-enhanced MRA who also underwent TEE within 1 month. A total of 10 innominate artery atheromas were demonstrated on MRA; none of these were visualized on TEE. One patient had three atheromas, two patients had two atheromas and three patients had one atheroma. They ranged in size from 3 mm to 1.5 cm (mean 6.5 mm). One atheroma was flat, two were filiform, and seven were protruding. Gadolinium-enhanced MRA is superior to TEE for the diagnosis of atheromas of the innominate artery. In the setting of right cerebral or right arm embolization, when no source is seen in the arch on TEE, gadolinium-enhanced MRA should be considered.
The purpose of this study was to compare three T1-weighted sequences for hepatic magnetic resonance (MRI) imaging with the use of a body phased array coil. Three different T1-weighted MR sequences were compared: a conventional spin echo (CSE); half-Fourier spin echo (HFSE), and a gradient recalled echo (GRE). Three independent reviewers compared the sequences both quantitatively and qualitatively. The T1-weighted GRE sequence scored highest for overall image quality (p < 0.001), lesion conspicuity (p = 0.012), and yielded the highest contrast to noise (C/N) values. GRE T1-weighted images are the best for hepatic MRI.
The objective of this article was to compare half-dose (0.05 mm/kg) gadolinium-enhanced dynamic hepatic MR imaging to standard doses (0.10 mm/kg). Eighteen patients for follow-up hepatic MR received 0.05 mm/kg of gadolinium DTPA dynamically with gradient-echo imaging. Imaging parameters were identical to a 0.10-mm/kg study; patients were imaged during multiple phases of contrast enhancement. Two readers assessed for enhancement patterns and characterization. Quantitative signal-to-noise ratios (S/N) were obtained for abdominal viscera and contrast-to-noise ratios (C/N) were obtained on up to three lesions. No significant difference for the arterial dominant phase (P > 0.05) was found. Significant differences were found in all categories during the portal venous phase (except pancreas) and equilibrium phase (except liver). Lesion C/N ratios were not significant at any point (P > 0.05). Sixty-two out of 64 lesions (97%) were identically characterized. Therefore, half-dose dynamic gadolinium-enhanced MR may have diagnostic value.
Dissection of the ascending aorta is usually associated with severe chest and/or back pain. We describe three young men, with pathologically proven cystic medial necrosis, who presented with atypical clinical symptoms and ascending aortic dissection diagnosed by MR imaging and surgery. Patients with cystic medial necrosis and aortic dissection may not present with a classic acute chest pain syndrome.
Explore the source record for details and available documents.
PURPOSE: Our purpose was to determine the effects of apnea during end-inspiration compared with free breathing on timing examinations performed to optimize gadolinium-enhanced 3D MR angiography (MRA) of the thoracic aorta and arch vessels. METHOD: Thirty patients referred for gadolinium-enhanced 3D MRA of the thoracic aorta and branch vessels underwent two timing examinations: one performed during free breathing and one during apnea at end-inspiration to replicate more closely the respiratory pattern used to obtain 3D MRA. For each, axial images at the level of the proximal neck were acquired every 2 s for 40 s, during which time 1 ml of gadolinium contrast agent followed by 20 ml of saline was infused at 2 ml/s. The time to peak arterial enhancement (Ta), time to first jugular venous enhancement (Tj), and arterio-venous window (time from peak arterial enhancement to first jugular venous enhancement; AV) were compared for the two examinations in each patient. RESULTS: Overall there was no statistically significant difference in Ta, Tj, or AV between examinations performed during free breathing and apnea in end-inspiration, although a trend to delayed circulation times was observed with apnea (p = 0.2-0.3). In five patients (17%), the difference in Ta between free breathing and apnea was 4 s; in three patients (10%), the difference was 6 s. CONCLUSION: Circulation times determined during apnea at end-inspiration may differ from those obtained during free breathing by as much as 6 s in an individual patient. This difference may account for inappropriately timed gadolinium-enhanced MR angiograms performed with timing examinations, especially when very short acquisition times and low doses of gadolinium (20 ml) are used.
Cirrhosis is a progressive, diffuse process of liver fibrosis that is characterized by architectural distortion and the development of a spectrum of nodules ranging from benign regenerative nodules to premalignant dysplastic nodules to overtly malignant hepatocellular carcinoma. The purpose of this essay is to demonstrate the ex vivo MR and pathology findings of these nodules as well as other masses that can be seen in the cirrhotic liver. The optimal conditions under which ex vivo imaging can be performed allow greater spatial resolution than that achieved with in vivo imaging, without artifacts that may degrade image quality. Clearly, contrast-enhanced MRI is essential for both the diagnosis and the characterization of focal lesions in the cirrhotic liver. However, the use of ex vivo imaging precludes the evaluation of these important in vivo pulse sequences.
PURPOSE: The purpose of this work was to determine the sensitivity of hepatic digital subtraction arteriography (DSA) for the detection of hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) when compared with pathological findings from whole liver explants. METHOD: Twenty-one patients 30-72 years old (mean 54 years) with cirrhosis and known or clinically suspected HCC (20 prior to chemoembolization) underwent hepatic DSA with subsequent transplantation within 80 days (mean 32 days). The prospective DSA report was compared with pathologic findings from explanted livers. RESULTS: Overall, DSA detected 31 of 95 HCC lesions for a sensitivity of 33%. Of these 31 lesions, 28 were hypervascular and 3 were hypovascular. DSA detected all six HCCs measuring >5 cm, all six HCCs measuring 3-5 cm, and all five HCCs 2-3 cm, resulting in a sensitivity of 100% (17/17) for HCC >2 cm. DSA detected 7 of 18 HCCs measuring 1-2 cm (sensitivity 39%) and 7 of 60 HCCs < or =1 cm (sensitivity 12%). Overall sensitivity for DSA in detection of HCC < or =2 cm was 18% (14/78 lesions). None of 17 DNs (0.2-1.5 cm in size) was identified on DSA. CONCLUSION: DSA is insensitive to small HCC (< or =2 cm), carcinomatosis arising within nodules, and DN.
OBJECTIVE: To determine if iron containing "siderotic" nodules detected at magnetic resonance (MR) imaging are regenerative (RN) or dysplastic (DN) and to attempt to identify features that may distinguish them. MATERIAL AND METHODS: MR imaging (1.5 T) was performed on 77 cirrhotic patients who underwent orthotopic liver transplantation within 0-117 days (mean 30 days) of MR imaging. Two readers retrospectively evaluated breath-hold gradient-echo pulse sequences (echo time > or =9.0 ms, flip angle < or =45 degrees) for the presence of hypointense nodules, which were classified as micronodular (< or =3 mm), macronodular (>3 mm), or mixed. Nodule distribution was classified as focal (<5), scattered (5-20), or diffuse (>20) per slice. Thin section pathologic correlation was available in all cases, and Prussian blue iron stains were performed. RESULTS: Of 35 patients with pathologically proven siderotic nodules, 10 (29%) had at least 2 siderotic DN. MR detected siderotic nodules in 10 of 10 (100%) patients with siderotic DN and RN, and in 18 of 25 patients (72%) with siderotic RN only. CONCLUSION: Siderotic RN cannot be reliably distinguished from siderotic DN with MR imaging, and therefore the widely used term "siderotic regenerative nodule" should be avoided and replaced by "siderotic nodule."