Dynamic field shaping to optimize stereotactic radiosurgery.

A dynamic field shaping collimation system is evaluated for use in stereotactic radiosurgery of non-spherical lesions. The concept is as follows: (a) use the existing circular collimators to define a cone which encompasses the maximum dimensions of the target volume; (b) position two sets of independent rectangular photon collimators immediately upstream from the circular aperture and allow each collimator to have independent translational and rotational motion in order to define, for each increment of arc, a polygonal field shape having up to four straight and four curved edges which enscribe the beam's eye projection of the target; (c) modify the translational and rotational position of each independent collimator with each change in arc angle to continuously shape the instantaneous field to the target shape. A prototype device has been constructed and uses vane control technology developed in a related research project in electron arc therapy. The efficacy of this device is illustrated by dose calculations and measurement based on actual clinical data. Dose volume histograms are used to compare the dose received by three techniques: single isocenter treatment using a single circular aperture, dual isocenter treatment, and single isocenter treatment using dynamically shaped fields. Doses were calculated throughout the brain using a volume grid of 3 mm spacing. Dose volume histograms comparing dose within the target volume and brain volume excluding target volume, as well as computed isodose distributions, demonstrate the possible reduction in normal tissue dose burden while simultaneously preserving dose uniformity throughout the prescribed target volume. This simple four-vane collimation system may provide a viable alternate treatment technique for non-spherical lesions.

Humans↗

Electron arc therapy: design, implementation and evaluation of a dynamic multi-vane collimator system.

Innovative techniques in motion control technology have been applied to the design and implementation of a portable computer-controlled multi-vane collimator for use in electron arc therapy. The collimator, consisting of 18 independently controlled vanes, is inserted into the standard accessory mount assembly of a linear accelerator, in the same fashion as standard field shaping blocks. Power is supplied to the collimator vane motors via a self-contained battery system. The range of motion of the vanes, symmetrically mounted nine on each side, provides a variable aperture width projected to isocenter of 2 cm minimum to 8 cm maximum. The projected length of the aperture at isocenter is 38 cm. The transition time between vane positions is less than 1 second, corresponding to gantry movement of less than 1 degree. The movement of each of the 18 vanes is monitored and controlled by six individually addressed three axis processors that are shielded from the electron beam. A table of collimator vane positions versus gantry angle, as determined by dose optimization calculations, is stored in a data file. The desired collimator vane position corresponding to the current arc segment is conveyed from the control console to each vane controller via packets within a token passing network. Communication between the computer in the console area and the vane controllers is accomplished through encoded infra-red pulse transmission, eliminating the need for additional communication lines between the console and the accelerator. This dynamic collimator offers improved dose uniformity while simplifying the delivery of electron arc therapy.

Electronics, Medical↗