PubMed Health⌕ Search

Biomedical subjects

G G Condorelli

Publications and source records attributed to G G Condorelli.

4 recordsLinked to original sources

Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation.

The present work analyzes possible increases in resistance to wear of nickel-titanium endodontic instruments that have undergone a process of ionic implantation. ProFile .04 taper #25 instruments were subjected to ionic implantation with bands of nitrogen ions of 250 KeV, currents in the order of 10 microA/cm2, and doses of 2 x 10(17) ions/ cm2. The instruments were used to make preparations in acrylic endodontic training blocks. Scanning electron microscopic investigations showed that after 60 s of work inside the endodontic training blocks nonionic implanted control instruments showed small modifications in their blades, and their tips showed the first signs of wear. After 240 s the control instruments showed consistent signs of wear and frequent changes to their surfaces. After 240 s of use the ionic-implanted instruments did not present any significant changes in the micromorphology of their surfaces. The implanted instruments did not manifest the typical signs of wear and did not show the surface changes that quickly affect the working life of untreated endodontic instruments manufactured from nickel-titanium.

Dental Instruments↗

Defects in GT rotary instruments after use: an SEM study.

Used rotary nickel-titanium instruments require frequent replacement. This laboratory study evaluated defects of GT Rotary instruments before and after usage. The instruments were fixed into custom-made holders and photographed in an SEM at x 260 to x 12,000 magnification at preset points. Instrument sizes 20 with 1.0, 0.8, and 0.6 taper and instrument sizes 35 with 1.2 taper were used in 12 canals. The used instruments were cleaned and then reexamined in an SEM as before. The presence of 11 types of conditions was scored from the pre- and postusage photographs. No instruments fracturing or plastic deformation was observed during the test. The presence of debris, pitting, and scraping changed significantly. Imperfections were found on used GT Rotary instruments and the presence of defects (pitting, scraping, and blunt-cutting edges) increased in all of the instruments. The behavior of GT Rotary instruments with usage seems to be different, compared with that found in other instruments.

Dental High-Speed Technique↗

The effect of surface treatments of nickel-titanium files on wear and cutting efficiency.

OBJECTIVES: This study was designed to verify whether nitridation treatment of the cutting surfaces resulted in surface or subsurface changes that produced an increase in the resistance to wear in nickel titanium (NiTi) endodontic files. STUDY DESIGN: Some experimental samples were exposed to ionic implantation by using 150 keV of nitrogen ions and doses of 1 x 10(17) ions per cm(2). Other samples were exposed to thermal nitridation processes performed for 480 minutes at 500 degrees C temperature. Control samples were not exposed to any process. The chemical composition of the surface layers of each sample was determined by means of x-ray photoelectron spectroscopy. The cutting efficiency was tested on an endotraining bloc. RESULTS: The experimental instruments showed in-depth distributions of chemical composition that were different from those seen in the control group; thermal-nitridated instruments demonstrated a surface ratio of nickel to titanium of 0.5. Implanted samples had a higher N/Ti ratio (1.2); this ratio may be due to the presence of a layer of titanium nitride. Samples in the experimental groups showed an increase in cutting ability as compared with the controls. CONCLUSIONS: Thermal nitridation and nitrogen-ionic implantation treatment of nickel-titanium files produced a higher wear resistance and an increased cutting capacity.

Dental Alloys↗

Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files.

OBJECTIVE: Nickel-titanium instruments that offer greater flexibility than instruments made of other metallic materials have been developed. This study evaluated the behavior in vitro of nickel-titanium rotary instruments under repeated sterilization cycles. STUDY DESIGN: To investigate changes in cutting ability and superficial alterations, 36 ProFile instruments, 18 with a taper of .04 and 18 with a taper of .06, were exposed to different sterilization cycles. Samples were divided into 3 groups of 12 files each. The 12 group A samples were exposed to 14 cycles of sterilization for 30 minutes; the 12 group B samples were exposed to 7 cycles of sterilization for 30 minutes; the 12 group C samples were not sterilized and served as a control group. Chemical compositions of the near surface layers of samples of each group were determined by means of Auger spectroscopy. RESULTS: The instruments that underwent the greatest number of sterilizations (group A) showed in-depth distributions of chemical composition that were different from those seen in the control group; this was the result of greater amounts of titanium oxide on the surfaces of the sterilized instruments. The files of group A showed a decrease in cutting efficiency in comparison with those of the control group. CONCLUSIONS: On the basis of this research on nickel-titanium files, we determined that repeated sterilizations under autoclave alter the superficial structure of such instruments.

Dental Instruments↗