Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation.

A new approach in discriminating the regional air volume changes in the lungs associated with either spontaneous or mechanical ventilation during assisted ventilation is presented. Impedance data are obtained by conventional electrical impedance tomography (EIT). The data are filtered in the range of either the spontaneous or the ventilator rate and processed by the functional EIT (f-EIT) evaluation technique, whereby the variation of the respective EIT data with time is determined and imaged. EIT measurements performed in an infant during synchronized intermittent mandatory ventilation were evaluated with this method and indicated that the specific local lung volume swings related to spontaneous and mechanical inhalations can be separated and imaged as tomograms. This noninvasive approach may become useful in optimizing the ventilatory pattern during advanced forms of artificial ventilation and may help the clinician in the therapy management of individual patients.

Blood Gas Analysis

Errors of the backextrapolation method in determination of the blood volume.

Backextrapolation is an empirical method to calculate the central volume of distribution (for example the blood volume). It is based on the compartment model, which says that after an injection the substance is distributed instantaneously in the central volume with no time delay. The occurrence of recirculation is not taken into account. The change of concentration with time of indocyanine green (ICG) was observed in an in vitro model, in which the volume was recirculating in 60 s and the clearance of the ICG could be varied. It was found that the higher the elimination of ICG, the higher was the error of the backextrapolation method. The theoretical consideration of Schröder et al (Biomed. Tech. 42 (1997) 7-11) was proved. If the injected substance is eliminated somewhere in the body (i.e. not by radioactive decay), the backextrapolation method produces large errors.

Artifacts

Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure.

The aim of the study was to analyze thoracic electrical impedance tomographic (EIT) measurements accomplished under conditions comparable with clinical situations during artificial ventilation. Multiple EIT measurements were performed in pigs in three transverse thoracic planes during the volume controlled mode of mechanical ventilation at various tidal volumes (V(T)) and positive end-expiratory pressures (PEEP). The protocol comprised following ventilatory patterns: 1) V(T)(400, 500, 600, 700 ml) was varied in a random order at various constant PEEP levels and 2) PEEP (2, 5, 8, 11, 14 cm H2O) was randomly modified during ventilation with a constant V(T). The EIT technique was used to generate cross-sectional images of 1) regional lung ventilation and 2) regional shifts in lung volume with PEEP. The quantitative analysis was performed in terms of the tidal amplitude of the impedance change, reflecting the volume of delivered gas at various preset V(T) and the end-expiratory impedance change, revealing the variation of the lung volume at various PEEP levels. The results showed: 1) an increase in the tidal amplitude of the impedance change, proportional to the delivered V(T) at all constant PEEP levels, 2) a rising end-expiratory impedance change, with PEEP reflecting an increase in gas volume, and 3) a PEEP-dependent redistribution of the ventilated gas between the planes. The generated images and the quantitative results indicate the ability of EIT to identify regional changes in V(T) and lung volume during mechanical ventilation.

Animals

Mapping of capillary flow, cellular redox state, and resting membrane potential in hypoperfused rat myocardium.

The influence on myocyte viability of ischemia-induced changes in capillary perfusion was studied in the hearts of anesthetized rats subjected to partial occlusion of the left coronary artery for 45 min. Timed plasma labeling was applied to determine perfusion patterns. Changes in the fluorescence of preloaded potential-sensitive dyes [tetramethylrhodamine methyl ester (TMRM) and bis-oxonol], of trypan blue, and of endogeneous NADH were utilized in characterizing myocyte viability in histological sections of the heart. Within the hypoperfused zone, localized areas appeared vascularly nonlabeled for periods of at least 10 min. Within these areas a reduction in TMRM fluorescence occurred in 82. 5% of the tissue, signaling a reduced resting membrane potential. In the same areas 37.7% of the myocytes revealed an NADH fluorescence lower than that regularly found in anoxic tissues. This correlated with an especially low level of TMRM, with increased fluorescence bis-oxonol and with an accumulation of trypan blue. In conclusion, in localized hypoperfusion-induced zones lacking capillary flow, an inhomogeneous pattern of reductions in myocyte viability develops, which appears to be relevant in ischemia-induced arrhythmias.

Animals

Optimizing deconvolution techniques by the application of the Münchhausen meta algorithm.

A deconvolution applied to disturbed data often gives poor results, due to fundamental difficulties associated with ill-posed problems. Many numerical and theoretical methods have been invented to circumvent this phenomenon. Their performance varies, depending on the given problem and data. The main aim of this paper is to provide a decision rule for choosing a method for deconvolution and application of this method to the same data. We have called this meta-algorithm Münchhausen. In this paper we introduce and describe for the first time the basic principle of artificial disturbance of the data in the set-up of deconvolution. We demonstrate some interesting features of the random procedure Münchhausen, such as the non parametric set-up, robustness to disturbance of the data and last but not least good performance.

Algorithms

Electrical impedance tomography in monitoring experimental lung injury.

OBJECTIVE: To apply electrical impedance tomography (EIT) and the new evaluation approach (the functional EIT) in monitoring the development of artificial lung injury. DESIGN: Acute experimental trial. SETTING: Operating room for animal experimental studies at a university hospital. SUBJECTS: Five pigs (41.3 +/- 4.1 kg, mean body weight +/- SD). INTERVENTIONS: The animals were anaesthetised and mechanically ventilated. Sixteen electrodes were attached on the thoracic circumference and used for electrical current injection and surface voltage measurement. Oleic acid was applied sequentially (total dose 0.05 ml/kg body weight) into the left pulmonary artery to produce selective unilateral lung injury. MEASUREMENTS AND RESULTS: The presence of lung injury was documented by significant changes of PaCO2 (40.1 mmHg vs control 37.1 mmHg), PaO2 (112.3 mmHg vs 187.5 mmHg), pH (7.35 vs 7.42), mean pulmonary arterial pressure (29.2 mmHg vs 20.8 mmHg) and chest radiography. EIT detected 1) a regional decrease in mean impedance variation over the affected left lung (-41.4% vs control) and an increase over the intact right lung (+ 20.4% vs control) indicating reduced ventilation of the affected, and a compensatory augmented ventilation of the unaffected lung and 2) a pronounced fall in local baseline electrical impedance over the injured lung (-20.6% vs control) with a moderate fall over the intact lung (-10.0% vs control) indicating the development of lung oedema in the injured lung with a probable atelectasis formation in the contralateral one. CONCLUSION: The development of the local impairment of pulmonary ventilation and the formation of lung oedema could be followed by EIT in an experimental model of lung injury. This technique may become a useful tool for monitoring local pulmonary ventilation in intensive care patients suffering from pulmonary disorders associated with regionally reduced ventilation, fluid accumulation and/or cell membrane changes.

Acute Disease

Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography.

BACKGROUND: Electrical impedance tomography (EIT) is a noninvasive technique providing cross-sectional images of the thorax. We have tested an extended evaluation procedure, the functional EIT (f-EIT), to identify the local shifts of ventilation known to occur during the transition between spontaneous, controlled and assisted ventilation modes. METHODS: Ten patients scheduled for elective laparotomy were studied in the surgical ward, operating theatre and ICU during spontaneous and different modes of mechanical ventilation. Sixteen ECG electrodes were placed on the circumference of the thorax and connected with an EIT device (APT System Mark I, IBEES, Sheffield, UK). Measurements lasting 180 s were performed and f-EIT images of regional ventilation computed. The geometrical centre of ventilation was determined to quantify the regional distribution of lung ventilation during individual modes of ventilation. RESULTS: F-EIT confirmed the differences in the distribution of ventilation associated with various modes of artificial ventilation. Accentuated ventilation of the dependent lung regions was observed during spontaneous breathing, whereas a shift of the centre of ventilation to the nondependent regions was found during controlled ventilation. In the course of assisted ventilation a continuous displacement of the centre of ventilation back towards the dependent lung regions, consistent with an increased proportion of spontaneous breathing, was detected. Unassisted spontaneous breathing after weaning from mechanical ventilation resulted in a similar ventilation distribution as during tidal breathing prior to surgery. CONCLUSION: F-EIT determined the redistribution of lung ventilation during different modes of mechanical ventilation. We expect that f-EIT will become a useful noninvasive bedside monitoring technique for imaging regional ventilation in pulmonary diseased patients during mechanical ventilation.

Abdomen

Simulation of the initial concentration-time course after intravenous application of the drug.

In this paper we present a widely applicable computational method for the description of the initial concentration-time-course after intravenous injection of a substance. The intravascular concentration-time course, r, is described as r = c0 + g x r, where the asterisk denotes the convolution operation, c0 is the concentration-time course during the first passage of the substance and g is the transport function of the body. If the body transport function is known, then the concentration-time course of a substance can be predicted. The site of interest can be chosen arbitrarily, i.e. the concentration-time course in the arterial circulation supplying any organ can be described. This might be of special interest for the optimal design of intravenous injections of contrast media, where initial concentrations at the region of interest determine the success of the diagnostic procedure.

Animals

Development and initial in vivo testing of a new hydraulic drive system (Paedipump) for circulatory support in infants.

The main limitation in the use of circulatory support in children is the lack of an adequate system with regard to size and pumping capacity. Recently, two pneumatically driven ventricular support systems with low volume chambers for use in a pediatric population became available. We have developed a hydraulic drive system with an advantageous exact control of the stroke volume. The system enables two different modes of operation: the full-empty and the filled-empty modes. In both cases the ventricle is empty at the end of systole. This new system was tested in experimental animals (6 pigs, body weight 9.5-14.0 kg) with normal and reduced left ventricular function (MAP<45 mmHg). A 25 ml ventricle (HIA-Medos) was implanted. The full-empty and the filled-empty mode used led to a significant load reduction, both in animals with normal and impaired cardiac function. Plasma lactate levels, pH-values and total body O2-consumption were in the normal range during circulatory support indicating adequate organ perfusion. Results showed that sufficient ventricular support was achieved during all pumping modes due to the possibility of controlling and modifying the stroke volume of the hydraulically driven support system employed according to necessity. This is a promising feature for its future application in infants with congenital or acquired heart diseases.

Animals

Influence of high-dose ketamine on the vascular reactivity of human and porcine isolated coronary artery segments.

The influence of ketamine on the vasomotor effect of histamine and serotonin was studied in isolated human and porcine coronary artery rings. Ketamine (10(-3) mol L-1) attenuated the contractile response to both mediators significantly (P < 0.05 for histamine concentrations of 3 x 10(-5) mol L-1 and above as well as for serotonin concentrations of 3 x 10(-8) mol L-1 and above). This effect of ketamine was observed in intact and endothelial denuded porcine rings (difference n.s.) as well as in coronary arteries from explanted human hearts of patients undergoing heart transplantation. It is concluded that this reduction of the contractile response to histamine and serotonin caused by ketamine is not dependent on the endothelial function (e.g. endothelium-derived relaxing factor).

Anesthetics, Dissociative

Modelling of non-linear pharmacokinetics in sheep after short-term infusion of cardiotoxic doses of imipramine.

Imipramine was administered to sheep (n = 10) by intravenous infusion in high doses (450 mg-900 mg) to elicit cardiovascular shock. A cardiac assist device was then employed to manage the acute overdose situation. The concentration-time course of imipramine and its metabolite desmethylimipramine in plasma was measured by HPLC. As an indicator of imipramine's cardiotoxic effect, cardiac output was monitored. The aim of the study was to evaluate the pharmacokinetics under these conditions and to assess the efficiency of a cardiac assist device with (n = 5) and without (n = 5) an integrated haemoperfusion unit in removing drug from the circulation. The kinetics of imipramine could be described by a three compartment body model with concentration-dependent clearance resulting in non-linear kinetics. The changes in cardiac output with time could be linked to the pharmacokinetic model by a linear relationship. The cardiac assist device was found to contribute to the overall elimination of imipramine whereas the haemoperfusion unit had no clinically relevant impact.

Animals

[LOGNORMAL-NLSQ-technique. Evaluation of a new mathematical method for determining blood volume].

This paper describes the investigation of a new mathematical method of calculating blood volume. The new method determines the blood volume by calculating the product of the mean circulation transit time. The mean transit time is calculated from the body transport function. To examine the accuracy of the LOGNORMAL-NLSQ technique, 45 concentration time curves were measured in an in vitro recirculation model with variable clearance. The calculated volume was 4% smaller than the actual volume. This may be attributed to the functional dead space within the model, and is tolerable for clinical situations. The LOGNORMAL-NLSQ technique might acquire considerable importance in future, especially since it provides accurate results very quickly.

Blood Flow Velocity

Gravity-dependent phenomena in lung ventilation determined by functional EIT.

Gravity exerts an effect on the distribution of intrapulmonary ventilation. A study on the detection of gravity-dependent inhomogeneity of ventilation by a functional EIT technique is presented. The study was performed on five human subjects, whose ventilation distribution was modified by changes in body position. The subjects were studied during spontaneous tidal breathing. The qualitative and quantitative analysis of the functional EIT images revealed that the ventilation is higher in the dependent lung regions when compared with the non-dependent ones. These EIT findings correspond to current knowledge of the physiological behaviour of the lungs as derived from the radioactive-gas methods and raise the possibility of applying the less complicated functional EIT in future studies on ventilation distribution in the lungs. This may be of major interest in the monitoring of intensive care patients with severe pulmonary disorders.

Adult

Local mechanics of the lung tissue determined by functional EIT.

A new functional EIT (f-EIT) evaluation technique providing information on the local dynamic behaviour of the lung is presented. Out of a series of single EIT thoracic images local time courses of the impedance change are extracted. To detect regional differences in the dynamic behaviour of the lung tissue the local time courses at different locations are related to the average time course of the impedance change over the whole thoracic cross section. The time shifts between this reference signal and the signals from separate positions are calculated from the phase information of the complex cross spectra and evaluated in terms of the local phase angle. The computed phaseshifts are imaged over the cross section creating an 'f-EIT phase image' characterizing the local dynamic properties. To relate the observed differences to the proper lung location the resulting images are presented as a combination of the f-EIT ventilation images, which represent the local amplitude of ventilation and the f-EIT phase images. The new imaging technique was tested in spontaneously breathing humans. Alterations to pulmonary dynamics were induced by changing the body posture of the subjects. The f-EIT phase imaging procedure was shown to identify lung regions with different dynamics and it is expected that this technique will also distinguish pathologically determined alterations.

Biomechanical Phenomena

Myocardial extraction of bupivacaine in anaesthetized sheep and by hearts of sheep and rats in vitro.

We observed the in vivo kinetics of bupivacaine in the cardiopulmonary system, particularly in the pulmonary artery, the upper part of the descending aorta and the coronary sinus of anaesthetized sheep, each of which received a high dose infusion into the central vein. In some experiments dilution curves were monitored for the non-extracted dye, indocyanine green. Concentrations of bupivacaine were approximately 20% lower in the aorta than in the pulmonary artery. This gradient of bupivacaine was present across the lung for 5-10 min. Concentrations of bupivacaine in the coronary venous plasma were also markedly lower than at the arterial site. Initially more than 50% of the amount of bupivacaine at the arterial site was removed by the heart. Later, the myocardial extraction ratio decreased and plateaued at a value of 0.30-0.40. At this time, concentrations of bupivacaine in the pulmonary artery were approximately 12 micrograms ml-1. Therefore, approximately 0.3-0.6 mg of bupivacaine were extracted per minute by the sheep heart in vivo. On the other hand, isolated perfused rat hearts did not substantially remove bupivacaine (2 micrograms ml-1) from the medium. Approximately one-third of 14C-bupivacaine was retained in slices of rat and sheep myocardial tissue. However, there was no evidence that metabolism played a substantial role in the cardiac kinetics of bupivacaine.

Anesthetics, Local

Pulmonary and left ventricular decompression by artificial pulmonary valve incompetence during percutaneous cardiopulmonary bypass support in cardiac arrest.

BACKGROUND: In cardiac arrest, use of percutaneous cardiopulmonary bypass support (PCPS) may lead to left ventricular loading, with deleterious effects on the myocardium, and is often accompanied by an increase in pulmonary artery pressure. The present study was designed to assess the potential of artificially induced pulmonary valve incompetency to retrogradely decompress the left ventricle during PCPS in ventricular fibrillation. METHODS AND RESULTS: Studies were performed using a standardized experimental animal model in sheep (n = 12; body weight, 77 to 112 kg). When PCPS was used during fibrillation, an increase in left ventricular pressure (from 21.4 +/- 5.0 mm Hg after 1 minute to 28.4 +/- 9.5 mm Hg after 10 minutes of fibrillation) was observed in all animals, with a simultaneous increase in pulmonary artery pressure in 6 animals, from 15.5 +/- 3.8 to 24.3 +/- 5.4 mm Hg (group A). In these animals, artificial pulmonary valve incompetency, which was induced by a special "pulmonary valve spreading catheter," led to effective decompression of both the pulmonary circulation (decrease in pulmonary artery pressure from 24.3 to 11.3 mm Hg) and the left ventricle (decrease in left ventricular pressure from 30.5 to 17.7 mm Hg). We simultaneously measured a decrease in the myocardial release of lactate (increase in arterial coronaryvenous difference in lactate content from -0.01 to 0.14 mmol/L), demonstrating the myocardial protective effect of the procedure. In contrast, in 6 animals without an increase in pulmonary artery pressure during PCPS (group B), artificial pulmonary valve incompetency did not reduce left ventricular loading, which was probably because of competent mitral valves in these animals. CONCLUSIONS: In case of increasing pulmonary artery pressure during PCPS in cardiac arrest, artificial pulmonary valve incompetency might be a useful tool for effective pulmonary and retrograde left ventricular decompression.

Animals