PubMed Health⌕ Search

Biomedical subjects

G Rescigno

Publications and source records attributed to G Rescigno.

At least 19 recordsLinked to original sources

Transglutaminase 1 gene mutations in Italian patients with autosomal recessive lamellar ichthyosis.

We analyzed the transglutaminase 1 gene locus in patients from six unrelated Italian families affected by autosomal recessive lamellar ichthyosis. In two families we identified a novel mutation (E520G) in the gene coding region, a previously reported splicing mutation (A3447G), and the mis-sense mutations S272P and V518M. The latter mutation, hitherto considered disease causing, was found to be a simple polymorphism. Linkage to transglutaminase 1 gene was excluded in two of the other four families examined. Single strand conformational polymorphism analysis of the transglutaminase 1 gene in the remaining two families did not reveal any alteration in the coding region. This finding confirms the genetic heterogeneity of the disease.

DNA, Recombinant↗

Patterns of systolic stress distribution on mitral valve anterior leaflet chordal apparatus. A structural mechanical theoretical analysis.

Increasing diffusion and complexity of mitral valve repair procedures may prompt an interest in the evaluation of the patterns of stress distribution on the chords, which are, from the structural mechanical point of view, the weakest element of valve apparatus. This theoretical analysis concentrates in particular on the mitral valve anterior leaflet. As is known, the vast majority of the chordae are attached to the anterior leaflet within the coaptation area; during systole they are then necessarily parallel, aligned along the same plane as that of the leaflets' coaptation surface, to which they are attached; moreover the thickness of the chordae increases significantly from the marginal chordae to the more central ones. In normal conditions during systole the progressively wider coaptation surface causes the increasing stress to be supported by an increasing number of progressively thicker chords, which are substantially parallel and aligned on the coaptation surface plane in such a way that they can share the stress between them, according to their thickness; in other words chords form a multifilament functional unit which enrolls elements of increasing thickness in response to the mounting stress. The geometrical modifications of the valve apparatus architecture (annulus dilatation, leaflet retraction, chordal elongation or retraction) often associated with valve insufficiency due to chordal rupture, have the common result of causing, during systole, a radial disarrangement of the direction of most of the secondary chordae which are no longer parallel, aligned on the coaptation surface plane. Due to the negligible elastic module of the valve leaflet, in this new arrangement the various chordae cannot share the stress between themselves as they do in a normal physiological situation; on the contrary the thinner chordae nearer to the free margin are also loaded with the peak systolic stress, thus generating conditions favoring their rupture. It can, therefore, be hypothesized that the anatomopathological picture of valve insufficiency due to chordal rupture may be the final event of a series of geometrical modifications of valve apparatus architecture, the common consequence of which is to load thinner marginal chords with peak systolic stress from which they are normally spared, thus favoring their rupture.

Animals↗

Pericardial patch for rapid and effective hemostasis of cardioplegia injection site.

Cardioplegia injection site may be the source of serious haemorrhagic complications either intraoperatively or during the early postoperative period. Here we describe a simple technique that allows a rapid control of hemostasis at this site. An autologous pericardial patch is used to repair and strengthen the aortic wall.

Aorta, Thoracic↗

Effective reduction of a giant left atrium by partial autotransplantation.

Although many surgical procedures have been proposed to reduce the size of a left atrium, their effectiveness is not well established. We present a case of mitral and tricuspid valve insufficiency with a giant left atrium. Partial heart autotransplantation was used in a mitral and tricuspid valve operation with a successful outcome. This procedure can be an effective method to treat giant left atrium.

Aged↗

Advancement flaps to treat superficial wound infections after cardiac operations.

The management of superficial sternal wound infections is not well-codified. In case of large necrosis or tissue defect we use a two-stage approach, consisting of a first surgical debridement, followed a few days later by wound closure by means of two lateral advancement flaps. We have used this technique with good cosmetic results and shorter hospital stays.

Cardiac Surgical Procedures↗

Clinical evaluation of the Physio annuloplasty ring.

STUDY OBJECTIVES: Prospective evaluation of a selectively flexible annuloplasty ring was undertaken to assess its safety and efficacy. PATIENTS: Between December 1992 and November 1996, 190 patients with mitral regurgitation underwent mitral valve repair using an annuloplasty ring (Carpentier-Edwards Physio; Baxter-Edwards CVS Laboratories; Irvine, Calif). Ninety-four were in New York Heart Association class I or II. Etiology was degenerative in 74% of the patients. RESULTS: Four patients died early for a hospital mortality of 2.1%, and one late death occurred. Two patients with systolic anterior motion required early valve replacement. Two transient episodes of hemiparesis occurred during the first postoperative month. There were no late thromboembolic complications, no late reoperation, and no endocarditis. Mean follow up of 23+/-13 months was complete in 99% of the patients. Seventy-seven patients (40.5%) have had Doppler echocardiography > 1 year after surgery: 61 (80%) of them have no residual regurgitation, 15 have grade 1+/4+ mitral regurgitation, while 1 has grade 2+/4+ insufficiency. Left ventricular end-diastolic volume index (mL/lm2) decreased from 107.4+/-35.5 preoperatively to 74.2+/-24.4 at last control (p<0.001). CONCLUSION: The physio annuloplasty ring provided reliable and stable results at medium-term follow-up with a very low incidence of valve-related complications.

Echocardiography, Doppler↗

Continuous warm blood cardioplegia pitfalls and solutions.

BACKGROUND: Continuous warm blood cardioplegia offers superior preservation in both routine and complicated cardiac cases. Management of continuous perfusion is an important task during each case. METHODS: The authors have developed several specific techniques to ensure stable catheter insertion and placement for continuous coronary sinus or antegrade ostial perfusion. RESULTS: Over 3,800 patients have been operated on with continuous warm blood cardioplegia using catheter techniques as described in this article. The overall 30-day mortality was 3.9%. CONCLUSIONS: Safe application of continuous warm blood cardioplegia has many advantages over prior cold techniques, but surgeons must know certain technical modifications to be able to universally apply continuous techniques safely.

Blood↗

[Mitral valvuloplasty for asymptomatic or pauci-symptomatic mitral insufficiency].

The aim of this study was to assess the results of mitral valvuloplasty for chronic asymptomatic or paucisymptomatic mitral regurgitation. Of 584 patients operated for chronic mitral regurgitation between January 1989 and December 1994, 175 were in NYHA Classes I and II and made up the study population. All had chronic grade 3 or 4/4 mitral regurgitation suitable for mitral valvuloplasty. The average follow-up was 34.3 months. Mitral valvuloplasty was performed in 174 patients, the other patient requiring mitral valve replacement. Three patients died (1.7%) and the actuarial 5 year survival was 98.2 +/- 1.0%. The probability of absence of reoperation and absence of thrombo-embolic complications at 5 years were 97 +/- 0.8% and 96.3 +/- 1.7% respectively. The residual regurgitation at Doppler echocardiography was minimal or absent in 94% of patients at the last follow-up control. The mean end-systolic and end-diastolic left ventricular dimensions decreased from 40.0 +/- 6.8 mm and 64.8 +/- 7.0 mm before surgery to 34.6 +/- 6.7 mm (p < 0.001) and 52.7 +/- 7.4 mm (p < 0.001) at the last control. The authors conclude that conservative mitral valve surgery for NYHA Classes I and II patients with chronic mitral regurgitation is feasible with a low risk and is associated with a significant reduction in ventricular volumes and stability of valvular continence at medium-term. When performed by teams trained in techniques of mitral valvuloplasty, these results suggest that surgery should be performed early.

Actuarial Analysis↗

Prosthesis for aortic arch substitution.

BACKGROUND: The risk of neurologic complications in aortic arch prosthetic substitution is directly related to the duration of the circulatory arrest. The purpose of this article is to report the experiments on animals of a device for simplifying and quickening the vascular anastomosis in aortic arch substitution. METHODS: The device consists of expandable loops of stainless steel wire, sewn to the proximal end of a Dacron prosthesis. An actuating removable guide allows the stainless steel wire loops to be expanded and tightened, in such a way that the prosthesis diameter is varied, while maintaining a regular cylindric shape. The prosthesis end is then transformed into a rigid cylindrical ring, approximately half the maximal diameter in length, with a variable and controllable diameter. A composite graft was prepared, fitted with the expandable device at the distal end of the main prosthesis as well as at each end of the branches for the supraaortic trunks. Cardiopulmonary bypass was established by cannulation of the right atrium and left iliac artery. The prosthesis was positioned very easily and quickly during a brief hypothermic circulatory arrest; ascending aorta anastomosis was carried out by the standard technique after central nervous system reperfusion was resumed. Acute experiments were carried out in 5 swine. RESULTS: Four of 5 animals survived the procedure without detectable neurologic sequelae. At sacrifice the prosthesis was found to be properly sited without lumen distortion or thrombosis. CONCLUSIONS: The main advantages of this device and modality of arch substitution in a clinical setting would include drastic reduction of the circulatory arrest time, easy and reliable hemostasis of the anastomosis line, and accurate and firm approximation of the dissection layers in case of dissecting aneurysms.

Animals↗

[Initial results of mitral valvuloplasty using the Physio-Carpentier-Edwards ring].

The Physio-Carpentier-Edwards ring is a new prosthetic ring developed to allow mitral annuloplasty associating remodelling and flexibility of the native mitral annulus. The object of this study was to assess the feasibility and reliability of mitral valvuloplasty with the Physio ring. Between December 1992 and October 1995, 100 patients with an average age of 56.8 years suffering from mitral insufficiency underwent mitral valvuloplasty with a Physio ring. The mitral insufficiency was degenerative in 94% of cases. The degree of regurgitation was scored 3+ or 4/+4/+ in 94 patients. Mitral valve prolapse was observed in 83 patients. Mitral reconstruction was undertaken using Carpentier's techniques. One patient died in the immediate postoperative period. Two patients were reoperated for valve replacement because of systolic anterior motion (SAM). One patient had SAM which regressed with medical treatment. There were no deaths after the hospital period. There were no late reoperations of thrombo-embolic complications. The average follow-up period was 19 +/- 8 months; 77 patients were followed up for over 1 year and all underwent control Doppler echocardiography. Sixty-one patients had no residual mitral insufficiency: 15 patients had grade 1/4 regurgitation and one patient had grade 2/4 regurgitation. The average mitral valve surface area was 2.8 +/- 0.3 cm2. The average left ventricular end diastolic volume decreased from 186 +/- 59 cm3 before surgery to 129 +/- 37 cm3 at the last control (p < 0.001). The authors conclude that the Physio ring enables reliable and effective mitral valvuloplasty with excellent short term results. The benefits of the flexibility of the Physio ring remain to be evaluated by a randomised trial.

Aged↗

Surgical treatment of asymptomatic and mildly symptomatic mitral regurgitation.

OBJECTIVE: The purpose of this study was to review the risk-benefit ratio of mitral valve repair in patients with severe mitral regurgitation and no or mild symptoms. METHODS: From January 1989 to December 1994, 584 patients were operated on for mitral regurgitation. Of these, 175 patients were in New York Heart Association class I or II with grade 3 to 4 isolated chronic mitral regurgitation. They comprise our study population. Mean age was 51.3 +/- 14.3 years. Principal causes of mitral regurgitation were degenerative in 128 (73%) and rheumatic in 26 patients (15%). Leaflet prolapse was the mechanism responsible for regurgitation in 152 patients (86%). Mitral valve repair was performed in 174 patients, and one patient required initial valve replacement. Mean follow-up was 34.3 +/- 18.8 months. RESULTS: Three patients died, for an overall mortality of 1.7%. Five patients were reoperated on, for an actuarial freedom from reoperation of 97.0% +/- 0.8% at 5 years. Actuarial freedom from thromboembolism and endocarditis was 96.3% +/- 1.7% and 99.4% +/- 0.6%, respectively, for an event-free survival of 91.0% +/- 2.0% at 5 years. Left atrial diameter decreased from 54.3 +/- 11.6 mm to 43.6 +/- 10.5 mm (p < 0.001). Left ventricular end-systolic and end-diastolic diameters decreased from 40.0 +/- 6.8 mm and 64.8 +/- 7.0 mm to 34.6 +/- 6.7 mm (p < 0.001) and 52.7 +/- 7.4 mm (p < 0.001), respectively. Mean residual mitral regurgitation was 0.44 +/- 0.6. CONCLUSION: Mitral valve repair for chronic mitral regurgitation in patients having mild or no symptoms was performed with low mortality and morbidity, good valve function, and preserved late left ventricular performance. Early repair may be advocated on the basis of severity of regurgitation and valve repairability, regardless of symptoms.

Adult↗

Thoracoscopic approach to implantable cardioverter defibrillator patch electrode implantation.

Even if transvenous lead system for automatic implantable cardioverter defibrillators (ICDs) has been one of the main surgical advances in the recent past, its major limitation is the high defibrillation thresholds in some cases. Thus, an additional patch may be required and implanted either in a subcutaneous position or in an epicardial position. We describe another possibility: the implantation of extrapericardial patch under video-thoracoscopic control. This new technique allows a deep implantation of the whole material without thoracotomy. Seven patients were included in our preliminary experience. During defibrillation threshold evaluation, two patients required 34 J with the single transvenous lead system, and five patients were not defibrillated with the single lead system; therefore, they required a 300-J external rescue shock. We decided to implant an additional patch in those seven patients with high defibrillation thresholds. This patch was inserted into the pleural cavity through a left subcostal incision. Under video thoracoscopy, it was positioned and stitched onto the pericardium. The defibrillation generator was then implanted through the left subcostal incision in a subdiaphragmatic space. As a result, preoperative defibrillation thresholds were significantly reduced (14.29 +/- 3.45 J, mean +/- SD) and remained stable during follow-up controls (eighth day and second month). Long-term follow-up (14 +/- 4.5 months) was uneventful, with an excellent tolerance for the patients. In conclusion, extrapericardial implantation of defibrillation patches under video thoracoscopy is an easy technique that allows low defibrillation thresholds.

Adult↗

[Right-to-left interatrial shunt with normal pulmonary pressures after pneumonectomy. Apropos of a case with severe cyanosis following left pneumonectomy].

Atrial septal defects usually give rise to left-to right in the absence of obstruction of the pulmonary outflow tract or pulmonary hypertension. The authors report a case of atrial septal defect with a right-to-left shunt despite normal pulmonary pressures at catheterisation in a 56 year-old-man who had undergone left pneumonectomy 6 months previously. The shunt was responsible for major arterial desaturation aggravated by the left lateral or dorsal decubitus position. Surgical closure of the defect resulted in cure with disappearance of cyanosis and normalisation of blood gases. The physiopathological mechanisms of these right-to-left shunts with normal pulmonary pressures are discussed with reference to previously reported cases in the literature.

Blood Gas Analysis↗

Subdiaphragmatic implantation of implantable cardioverter defibrillator generator.

Despite several improvements in the surgical technique and in the technologic design of cardioverter defibrillators made over the past years, abdominal placement of the generator device, done as Mirowski did it in his first implantation performed in 1980, remains the widely used method. Although smaller defibrillators are available, they remain bulky and are a source of local complications. To prevent such complications and to enhance patient comfort, we performed a subdiaphragmatic implantation in 31 patients.

Defibrillators, Implantable↗