Doppler analysis of the left venting line: an effective and simple technique to control heart de-airing.

Air embolism is still a major risk of open-heart surgery. Different techniques of air removal have been established, even though none is completely effective. Since 1989 the authors have used a new technique to avoid air passage into the left vent line when the left heart cavities are open. A specially designed probe attached to a vascular Doppler analyser is fixed to the left vent tubing. Air passage is detected by a characteristic acoustic signal. Air removal procedures are continued until no audible signals are detected. This technique was carried out in 150 open left heart operations in which there were no clinical signs of air embolism. To validate this procedure, simultaneous assessment of air removal was made using transoesophageal echocardiography (TEE) and carotid Doppler (CD) in six patients. When Doppler signs of air in the left vent disappeared, TEE revealed that a small amount of air was still present in two patients; carotid Doppler showed only minimal passage of air bubbles in three patients after left vent removal while the heart was freely ejecting. These results demonstrate that this technique is a reliable method of assessing air removal, which is especially useful when de-airing is difficult during reoperation.

Cardiac Surgical Procedures↗

The backflow from the pulmonary circulation for identification of the aortic origin of the bronchial arteries in experimental left single lung transplantation.

The ideal solution to the bronchial healing problems in lung transplant would be the reconstruction of the bronchial arteries at time of transplantation. The problems with this approach are essentially technical being difficult to identify and preserve the bronchial arteries in humans. The purpose of this paper is to report our experience with an experimental model in dog to easily identify and preserve bronchial circulation in single lung transplantation. The technique is based on the preservation during harvesting of the aortic origin of the first five couples of arterial orifices. Identification of the orifice(s) connected with the bronchial circulation is carried out by the backflow which takes place from the pulmonary circulation after organ reperfusion is resumed. The identified orifice(s) is then anastomosed to the descending recipient aorta, tangentially clamped.

Animals↗

Valvular replacement for aortic stenosis on patients in NYHA class III and IV. Early and long term results.

From January 1972 to June 1990, 112 patients between 39 and 83 years old, divided into 68 NYHA class III (60.72%) and 44 NYHA class IV, underwent surgery for aortic stenosis. There were 67 male (59.82%) and 45 female (40.18%). Early mortality included 8 patients (7.14%). Actuarial survival (including early postoperative mortality) for all 112 patients was 88.39%, 77.67%, 67.85% and 65.7% t one year, five, ten and fifteen years respectively. Clinical criteria are subjective but they remain the best prognostic factor. Surgery is indicated at occurrence of first symptoms, but, even in advanced cases, aortic valvular replacement can significantly improve survival and functional status. Even if operative risk is increased and secondary cardiomyopathy often progresses after surgery, aortic valve replacement results seem better than those of medical treatment alone.

Adult↗

[Automatic implantable defibrillators; subdiaphragmatic insertion].

Although the material and techniques of implantation of the electrodes of implantable defibrillators have been improved, the abdominal implantation of the generator remains widely used as described by Mirowski in 1980. Despite a progressive reduction in their size, the generators remain bulky and a source of local complications. The risks and discomfort of implantation in the abdominal wall led the authors to try subdiaphragmatic implantation in 22 patients. There was no morbidity with perfect healing in all 22 cases. The mean follow-up period was 11 months. The patients felt very comfortable, a significant advance with respect to abdominal implantations.

Adolescent↗

[Implantation of automatic defibrillators by means of video-thoracoscopy. Authors' experience].

The implantable cardioverter-defibrillator represents an effective option for some potentially lethal ventricular arrhythmias. Nowadays defibrillation electrodes are often endoluminal only. In some patients, however, the presence of high defibrillation thresholds mandates the implantation of a subcutaneous patch. If the subcutaneous patch does not allow a sufficient decrease in defibrillation threshold, then two epicardial patches are generally implanted by different surgical approaches. Nevertheless surgical trauma could be a serious hazard in unstable patients. In 6 patients in whom endoluminal electrodes did not allow a safe defibrillation threshold, an extrapericardial patch has been implanted by means of a video-thoracoscopic approach: a left subcostal incision is performed and the subdiaphragmatic extraperitoneal space is reached; a patch electrode is then introduced into the left pleural cavity by blunt dissection of the diaphragm. This patch is positioned under thoracoscopic control in contact to the left pericardial surface and fixed by single stitches sutures. The impulse generator is finally implanted into the subdiaphragmatic pocket. In all the patients the patch electrode configuration sufficiently decreased defibrillation thresholds. In one of the patients a stellectomy was thoracoscopically performed to treat the long QT syndrome which was the cause of the ventricular fibrillation episodes. Defibrillation thresholds were confirmed after 8 day and 2 months postoperatively. In conclusion, the thoracoscopic implantation of an extrapericardial patch has allowed a significant reduction of defibrillation thresholds, without recurring to a major surgical procedure.

Defibrillators, Implantable↗

High-frequency perfusion fluorometry (HFPF): preliminary results on a new technique for assessing bronchial mucosa blood perfusion.

A new method for estimating airway mucosa blood perfusion is proposed. It is based on the use of a high-sensitivity perfusion fluorometer, which allows us to detect the first intravascular passage of injected fluorochromes. Total measuring time can be sensibly reduced with respect to standard perfusion fluorometry, allowing us to make assessments during fiberoptic bronchoscopy. In vitro studies were performed to set up the optical arrangement of the instrument. The optimal measuring distance (2.2 mm) between the probe tip and the fluorescent mucosa was established using a fluorescent film surface to simulate fluorescent mucosa. The depth of tissue layers involved in the fluorescence emission was assessed by positioning tissue sections of different thickness between the probe tip and the fluorescent film. Tissue layers at depths not exceeding 1200 microns were found to contribute to the fluorescence signal recorded by the instrument. Mucosa blood perfusion was evaluated in rat trachea, as a model, under three different experimental conditions of vascularization: (a) basal condition (BC), (b) partial devascularization (PD), (c) full devascularization (FD). Sodium fluorescein (diffusible into the interstice) and fluorescein isothiocyanate-dextran (not diffusible into the interstice) were used as fluorescent tracers. Under the BC both substances allowed us to detect the first passage of fluorochrome through the mucosa capillary network with the same accuracy. In PD the first pass peak disappeared; total emitted fluorescence decreased as well. In FD a flat tracing was recorded. Consistent results were obtained with both substances.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

[Postoperative infections. A prospective analysis of 1396 cases].

Postoperative infections are the most frequent complications in surgery and are the commonest cause of the lengthening of hospital stay. The purpose of this study is to prospectively evaluate the incidence and predisposing factors of postoperative infections in 1396 surgical patients admitted to our Institute from 1984 to 1988. Patients undergoing minor surgical procedures (wound less than 2 cm) were excluded from the study. Patients were evaluated daily during hospital stay for onset of infections and results recorded on data sheet. Hemocultures in septic patients and samples of exudate at site of infection were taken whenever possible for aerobic and anaerobic cultures. 368 patients (26.36%) had at least one postoperative septic complication; (79 of them [5.65%] had two or more infections). The following infections were recorded: wound infections: 148 (10.60%); respiratory tract infections: 144 (10.31%); urinary tract infections 125 (8.95%); miscellaneous infections 11 (0.78%); thrombophlebitis 23 (1.64%); FUO 10 (0.71%). The most important predisposing factor for wound infection was endogenous contamination (wound infections: 18/499 [3.60%] in clean, 42/594 [7.67%] in potentially contaminated, 57/217 [26.26%] in contaminated and 31/86 [36.04%] in dirty operations). The duration of the anaesthesia was found to correlate with an increased incidence of respiratory tract infections (4.49% anaesthesia less than 60 min; 7.21% anaesthesia greater than 60 less than 120 min; 15.31% greater than 120 min anaesthesia). Urinary infections were more frequent when the patients where catheterized at least once in the postoperative period (24.86% vs 3.2%).

Fever of Unknown Origin↗