Experiences in robotically enhanced IMA-preparation as initial step towards totally endoscopic coronary artery bypass grafting.

AIM: To evaluate the feasibility of robotically enhanced preparation of internal mammary arteries (IMA). METHOD: Via three trocars in left thoracic wall the left, right or both IMA were skeletonized under CO(2) insufflation and single lung ventilation using electrocautery. RESULTS: In 12 months, 26 LIMA, five BIMA and one RIMA were dissected. In five patients, the procedure had to be determined (IMA injury (two), respiratory insufficiency (two), and heart penetration (one)). Mean intrathoracic pressure was 9.7+/-1.5 mmHg. Mean time for LIMA and RIMA dissection was 66.7+/-21.1 and 99.2+/-8.7 min, respectively. In 10 patients, pericardium was incised and course of LAD assessed. However, in two patients, this coronary did not correlate with LAD. Time for instrument change depended on type of tool (cautery blade: 24.9+/-13.1 s, clip applier 72.8+/-28.4 s). CONCLUSION: Robotic dissection of IMA is reasonable. However, life-threatening complications can barely be managed due to inadequate tools and excessive time for instrument change. Incorrect determination of coronaries can result in misplaced anastomoses.

Aged↗

Left ventricular assist device as bridge to heart transplantation--lessons learned with the MicroMed DeBakey axial blood flow pump.

OBJECTIVE: The MicroMed DeBakey left ventricular assist device (LVAD) axial blood flow pump was used as bridge to heart transplantation (HTx) in patients with terminal heart failure. The aim was to evaluate this novel mechanical circulatory support system in regard to overall outcome. METHODS: Prospective study in 15 HTx candidates (mean age 40+/-7 years) with terminal heart failure and maximal medical treatment due to ischemic cardiomyopathy (CMP, n=5), dilated CMP (n=3), restrictive CMP (n=2), unclassified CMP (n=1), metabolic CMP (n=1), valvular CMP (n=1) and congenital CMP (n=2). All patients were implanted with a MicroMed DeBakey LVAD. A rescue procedure was necessary in eight critical patients, while seven underwent elective LVAD implantation. Procedures were performed via median sternotomy, in normotherm femoro-femoral CPB (mean duration 59+/-1 min). Oral Marcoumar (INR 2.0-3.0) and Aspirin (100 mg daily) were started as soon as possible. Patients were discharged into a specialized rehabilitation clinic from which it was possible to release them home after a few weeks. RESULTS: Successful implantation and discharge from ICU (mean stay 10+/-7 days) was possible in 11 patients. Seven were transplanted (mean support 50.7 days) and one is awaiting HTx (support >310 days) in the comfort of his home (NYHA I). Survival was 100% among the transplanted patients. Of the seven elective implants, five, and of the eight rescue procedures three patients underwent successful HTx. Four patients died early, while three patients died late on pump support due to intracranial hemorrhage (n=2, 73 and 76 days) and chest infection (n=1, 124 days). All survivors were discharged from hospital, with significant decrease in NYHA class (mean 3.8-2.4 (n=11)). Treadmill testing showed increased exercise tolerance, from 35 to 71W (n=4). Plasma BNP values (mean 950-162 ng/l (n=4)) and pulmonary resistance (mean 316-194.5 dyne s/cm(5) (n=3)) decreased significantly during LVAD support. CONCLUSIONS: The MicroMed DeBakey LVAD is simple to implant; outpatient treatment is safe and efficient. Patients' condition and pulmonary resistances normalize within 6 weeks, making previously considered inoperable patients amenable for HTx. HTx can be performed in low-risk situation, allowing better donor-recipient matching and improving overall outcome.

Adolescent↗

The relevance of large strains in functional tissue engineering of heart valves.

BACKGROUND: Exposing the developing tissue to flow and pressure in a bioreactor has been shown to enhance tissue formation in tissue-engineered heart valves. Animal studies showed excellent functionality in these valves in the pulmonary position. However, they lack the mechanical strength for implantation in the high-pressure aortic position. Improving the in vitro conditioning protocol is an important step towards the use of these valves as aortic heart valve replacements. In this study, the relevance of large strains to improve the mechanical conditioning protocol was investigated. METHODS: Using a newly developed device, engineered heart valve tissue was exposed to increasing cyclic strain in vitro. Tissue formation and mechanical properties were analyzed and compared to unstrained controls. RESULTS: Straining resulted in more pronounced and organized tissue formation with superior mechanical properties over unstrained controls. Overall tissue properties improved with increasing strain levels. CONCLUSIONS: The results demonstrate the significance of large strains in promoting tissue formation. This study may provide a methodological basis for tissue engineering of heart valves appropriate for systemic pressure applications.

Absorbable Implants↗

Advanced training model for beating heart coronary artery surgery: the Zurich heart-trainer.

OBJECTIVE: Coronary artery surgery with beating heart technique is gaining increasing popularity. However, it is a challenging technique even for well-trained cardiac surgeons. Thus, a training model for beating heart surgery was developed to increase safety and accuracy of this procedure. METHODS: The model consists of differentially hardened polyurethane resembling mechanical properties of the human heart. The covering used in this model is a 1:1 replica of the human thoracic wall with optionally embedded skeletal structures. Sternotomy, lateral thoracotomy or trocar placement is possible to access the lungs, the pericardium and the heart with adjacent vessels. Disposable artificial coronaries variable in size, wall quality or wall thickness are embedded in the synthetic myocardium. Two-layer vessels, which can simulate dissection, are available. Bypass conduits utilize the same material. Coronaries/bypasses as well as part of the ascending aorta are water-tight and can be rinsed with saline. Lungs can be inflated. A purpose-built pump induces heart movement with adjustable or randomized stroke volume, heart rate and arrhythmia induction. RESULTS: The model was tested in a recent 'Wet-Lab' course attended by 30 surgeons. All conventional instruments and stabilizers with standard techniques can be used. Training with beating or non-beating heart was possible. Time needed for an anastomosis was similar to clinical experience. Each artificial tissue showed its individual nature-like qualities. Various degrees of difficulty can be selected, according to stroke volume, heart rate, arrhythmia, vessel size and vessel quality. The model can be quickly and easily set up and is fully reusable. CONCLUSIONS: The similarity to human tissue and the easy set-up make this completely artificial model an ideal teaching tool to increase the confidence of cardiac surgeons dealing with beating heart and minimally invasive surgery.

Cardiac Surgical Procedures↗

Endoscopic saphenous vein harvesting for CABG -- a randomized, prospective trial.

BACKGROUND: The saphenous vein is an established conduit for coronary revascularization. Disadvantages of traditional harvest technique are significant pain and morbidity. We compared the endoscopic harvest technique with the traditional method. METHOD: 140 coronary artery bypass graft (CABG) patients were randomized into 2 groups: endoscopic vein harvesting (EVH; n = 80) and traditional open vein harvesting (OVH; n = 60). Analysis included preoperative risk factors for wound complication, harvesting time, graft injury, and intraoperative and postoperative complications. Patient follow-up lasted 3 months. RESULTS: The preoperative risk profiles of the groups were comparable. In the EVH group, 5 patients (7.1 %) had to be switched to the open technique. EVH time was 45 +/- 6.2 min vs. 31.1 +/- 6.5 min. Two patients (2.5 %) had to be revised because of bleeding complication vs. 6 (10 %) in the OVH group. No local infections or wound complications were observed in the EVH group vs. 11 (18 %) cases in the OVH group. Two OVH cases (3.6 %) were readmitted for wound debridement. All EVH patients reported less pain and were completely satisfied by the cosmetic results. CONCLUSION: EVH is a safe and efficient technique for CABG. Morbidity was significantly lower, with reduced pain and better cosmetic results. EVH time was significantly longer compared to the traditional harvesting technique.

Aged↗

Preoperative administration of steroids: influence on adhesion molecules and cytokines after cardiopulmonary bypass.

BACKGROUND: Cardiopulmonary bypass (CPB) is associated with tissue damage mediated by adhesion molecules and cytokines. Prebypass steroid administration may modulate the inflammatory response, resulting in improved postoperative recovery. METHODS: Fifty patients undergoing elective coronary operations under normothermic CPB were randomized into two groups: group A (n = 24) received intravenous methylprednisolone (10 mg/kg) 4 hours preoperatively, and group B (n = 26) served as controls. Cytokines (tumor necrosis factor-alpha [TNF-alpha], interleukin-2R [IL-2R], IL-6, IL-8), soluble adhesion molecules (sE-selectin, sICAM-1), C-reactive protein, and leukocytes were measured before steroid application, then 24 and 48 hours, and 6 days postoperatively. Adhesion molecules were measured by enzyme-linked immunosorbent assay, cytokines by chemiluminescent immunoassay. Postoperatively, hemodynamic measurements, inotropic agent requirements, blood loss, duration of mechanical ventilation, and intensive care unit stay were compared. RESULTS: Aortic cross-clamp and CPB time was similar in both groups. Prednisolone administration reduced postoperative levels of IL-6 (611 versus 92.7 pg/mL; p = 0.003), TNF-alpha (24.4 versus 11.0 pg/L, p = 0.02), and E-selectin (327 versus 107 ng/mL, p = 0.02). Postoperative recovery did not differ between groups. CONCLUSIONS: Preoperative administration of methylprednisolone blunted the increase of IL-6, TNF-alpha, and E-selectin levels after CPB but had no measurable effect on postoperative recovery.

Aged↗

Tissue engineering of small caliber vascular grafts.

OBJECTIVE: Previous tissue engineering approaches to create small caliber vascular grafts have been limited by the structural and mechanical immaturity of the constructs. This study uses a novel in vitro pulse duplicator system providing a 'biomimetic' environment during tissue formation to yield more mature, implantable vascular grafts. METHODS: Vascular grafts (I.D. 0.5 cm) were fabricated from novel bioabsorbable polymers (polyglycolic-acid/poly-4-hydroxybutyrate) and sequentially seeded with ovine vascular myofibroblasts and endothelial cells. After 4 days static culture, the grafts (n=24) were grown in vitro in a pulse duplicator system (bioreactor) for 4, 7, 14, 21, and 28 days. Controls (n=24) were grown in static culture conditions. Analysis of the neo-tissue included histology, scanning electron microscopy (SEM), and biochemical assays (DNA for cell content, 5-hydroxyproline for collagen). Mechanical testing was performed measuring the burst pressure and the suture retention strength. RESULTS: Histology showed viable, dense tissue in all samples. SEM demonstrated confluent smooth inner surfaces of the grafts exposed to pulsatile flow after 14 days. Biochemical analysis revealed a continuous increase of cell mass and collagen to 21 days compared to significantly lower values in the static controls. The mechanical properties of the pulsed vascular grafts comprised supra-physiological burst strength and suture retention strength appropriate for surgical implantation. CONCLUSIONS: This study demonstrates the feasibility of tissue engineering of viable, surgically implantable small caliber vascular grafts and the important effect of a 'biomimetic' in vitro environment on tissue maturation and extracellular matrix formation.

Absorbable Implants↗

Genetic predisposition in patients undergoing cardiopulmonary bypass surgery is associated with an increase of inflammatory cytokines.

OBJECTIVE: Cardiopulmonary bypass (CPB) surgery induces a transient rise in pro-inflammatory cytokines typically released by activated monocytes. The E4 variant of apolipoprotein E is a recognized risk factor for atherosclerosis. It has recently been shown that apolipoprotein E affects monocyte functions in vitro and leads to higher levels of median lipoprotein (a) in humans. The aim of the study is to investigate if the E4 genetic variant of apolipoprotein E affects cytokine release after CPB surgery. METHODS: 22 patients were operated on with standard coronary artery bypass grafting. Concentrations of interleukin 8 (IL-8) and tumor necrosis factor (TNF-alpha) were measured by automated Immulite immunoassay at regular intervals within 48 h after surgery. Total apparent cytokine outputs were calculated as area under the curve. Results are expressed as mean+/-standard deviation and compared by unpaired t-test. RESULTS: In the presented patient population 6 (27%) carried the E4 allele. Sixteen (63%) showed no E4 allele. Mean cross clamp time (CCT) was 56.2+/-13.5 min versus 55.7+/-12.1 min and CPB time was 91.8+/-17.5 versus 93.5+/-15.7 min. No statistical difference between E4-carriers and E4 non-carriers regarding CCT and CPB was observed. The total amount of IL-8 and TNF-alpha was higher in patients carrying the E4 genetic variant of apolipoprotein E in comparison to E4 non-carriers (P<0.08, P<0.039). CONCLUSION: The presence of the E4 allele is associated with increased release of IL-8 and TNF-alpha after CBP surgery. The preoperative determination of E4 in patients undergoing cardiac surgery may lead to additional perioperative measures for the treatment of an increased systemic inflammatory response.

Aged↗

Tissue engineering in cardiovascular surgery: new approach to develop completely human autologous tissue.

OBJECTIVE: In cardiovascular tissue engineering, three-dimensional scaffolds serve as physical supports and templates for cell attachment and tissue development. Currently used scaffolds are still far from ideal, they are potentially immunogenic and they show toxic degradation and inflammatory reactions. The aim of this study is to develop a new method for a three-dimensional completely autologous human tissue without using any scaffold materials. METHODS: Human aortic tissue is harvested from the ascending aorta in the operation room and worked up to pure human myofibroblasts cultures. These human aortic myofibroblasts cultures (1.5x10(6) cells, passage 3) were seeded into 15-cm culture dishes. Cells were cultured with Dulbecco' s modified Eagle's medium supplemented with 1 mM L-ascorbic acid 2-phosphate for 4 weeks to form myofibroblast sheets. The harvested cell sheets were folded to form four-layer sheets. The folded sheets were then framed up and cultured for another 4 weeks. Tissue development was evaluated by biochemical assay and light and electron microscopy. RESULTS: After 4 weeks of culture in ascorbic acid supplemented medium, myofibroblasts formed thin cell sheets in culture dishes. The cell sheets presented in a multi-layered pattern surrounded by extracellular matrices. Cultured for additional 4 weeks on the frames, the folded sheets further developed into more solid and flexible tissues. Light microscopy documented a structure resembling to a native tissue with confluent extracellular matrix. Under transmission electron microscope, viable cells and confluent bundles of striated mature collagen fibers were observed. Hydroxyproline assays showed significant increase of collagen content after culturing on the frames and were 80.5% of that of natural human pericardium. CONCLUSIONS: Improved cell culture technique may render human aortic myofibroblasts to a native tissue-like structure. A three-dimensional completely autologous human tissue may be further developed on the base of this structure with no show toxic degradation or inflammatory reactions.

Analysis of Variance↗

Fibrin gel as a three dimensional matrix in cardiovascular tissue engineering.

OBJECTIVE: In tissue engineering, three-dimensional biodegradable scaffolds are generally used as a basic structure for cell anchorage, cell proliferation and cell differentiation. The currently used biodegradable scaffolds in cardiovascular tissue engineering are potentially immunogenic, they show toxic degradation and inflammatory reactions. The aim of this study is to establish a new three-dimensional cell culture system within cells achieve uniform distribution and quick tissue development and with no toxic degradation or inflammatory reactions. METHODS: Human aortic tissue is harvested from the ascending aorta in the operation room and worked up to pure human myofibroblasts cultures. These human myofibroblasts cultures are suspended in fibrinogen solution and seeded into 6-well culture plates for cell development for 4 weeks and supplemented with different concentrations of aprotinin. Hydroxyproline assay and histological studies were performed to evaluate the tissue development in these fibrin gel structures. RESULTS: The light microscopy and the transmission electron microscopy studies for tissue development based on the three-dimensional fibrin gel structures showed homogenous cell growth and confluent collagen production. No toxic degradation or inflammatory reactions could be detected. Furthermore, fibrin gel myofibroblasts structures dissolved within 2 days in medium without aprotinin, but medium supplemented with higher concentration of aprotinin retained the three-dimensional structure and had a higher collagen content (P<0.005) and a better tissue development. CONCLUSIONS: A three-dimensional fibrin gel structure can serve as a useful scaffold for tissue engineering with controlled degradation, excellent seeding effects and good tissue development.

Aorta↗

Expression of adhesion molecules and cytokines after coronary artery bypass grafting during normothermic and hypothermic cardiac arrest.

OBJECTIVE: Cardiac surgery with cardiopulmonary bypass (CPB) results in vascular injury and tissue damage which involves leukocyte-endothelial interactions mediated by cytokines and adhesion molecules. This study was designed to demonstrate the effect of normothermic and hypothermic CPB to cytokine and soluble adhesion molecule levels in adults and to determine whether these levels correlate to the patients postoperative course. DESIGN AND PATIENTS: In 25 patients after normothermic and in 25 patients after hypothermic coronary artery bypass grafting with cardiopulmonary bypass (CPB), blood samples for cytokine and soluble adhesion molecule analysis were taken preoperatively, 24, 36, 48 h, and 6 days postoperatively. Soluble adhesion molecules (sE-selectin, sICAM-1) were measured by ELISA and cytokines (TNF-alpha, IL-6, IL-8) by chemilumenscent-immunoassay. Clinical data were collected prospectively. RESULTS: Postoperatively, adhesion molecule and cytokine levels were significantly elevated after CPB. Mean plasma levels of sICAM-1 was 2.4-fold higher after 6 days. Mean plasma concentration of sE-selectin peaked after 48 h with a 2-fold increase compared to normothermic conditions. In the hypothermia group sICAM-1, sE-selectin, IL-6, and IL-8 showed significantly higher levels (P<0.0057, P<0.0012, P<0.0419, P<0.0145) after 24 h compared to the normothermia group. No clinical differences were seen. CONCLUSION: Adhesion molecules and cytokines are elevated after CPB. Patients after hypothermic CPB show significant higher sICAM-1, sE-selectin, IL-6, and IL-8 levels after 24 h compared to normothermic conditions. These results are mainly due to longer CPB and crossclamp times but do not alter the patient's postoperative course.

Adult↗

Modified ultrafiltration lowers adhesion molecule and cytokine levels after cardiopulmonary bypass without clinical relevance in adults.

OBJECTIVE: Cardiac surgery with cardiopulmonary bypass (CPB) results in expression of cytokines and adhesion molecules (AM) with subsequent inflammatory response. The purpose of the study was to evaluate the clinical impact of modified ultrafiltration (MUF) and its efficacy in reducing cytokines and AM following coronary artery bypass grafting (CABG) in adults. METHODS: A prospective randomized study of 97 patients undergoing elective CABG was designed. Fifty patients were operated on using normothermic and 47 patients using hypothermic CPB. The normothermic group was subdivided into a group with modified ultrafiltration (n = 30) and a group without MUF (n = 20). In the hypothermic group 30 patients received MUF compared to 17 patients serving as controls. MUF was instituted after CPB for 15 min through the arterial and venous bypass circuit lines. Cytokines (IL-6, IL-8, TNF-alpha, IL-2R) and adhesion molecules (sE-selectin, sICAM-1) were measured preoperatively, pre-MUF, in the ultrafiltrate, 24 h, 48 h and 6 days after surgery by chemiluminescent enzyme immunometric assay or enzyme-linked immunosorbent assay (ELISA). Clinical parameters were collected prospectively until discharge. RESULTS: In all patients AM and cytokines were significantly elevated after normothermic and hypothemic CPB. AM and cytokines were significantly higher in hypothermia compared to normothermia. In hypothermic CPB sE-selectin was decreased after 24 h by 37% (P < 0.0063) and by 40% (P < 0.0027) after 48 h postoperatively. ICAM-1 was reduced by 43% (P < 0.0001) after 24 h and by 60% (P < 0.0001) after 6 days. Similar results were seen in cytokines with reduction up to 60% after 24 h. Changes after 48 h were noticeable but not significant. Reduction of AM and cytokines after normothermic CPB was minimal. Neither in normothermia, nor in hypothermia has sIL-2R been effectively removed from the circulation. There were no significant differences in the clinical variables between the patients with or without MUF. CONCLUSION: AM and cytokines are significantly elevated after hypothermic CPB compared to normothermic CPB. MUF led to a significant reduction in cytokine and AM levels after hypothermic CPB, except for IL-2R. MUF showed minimal effect in normothermia. We conclude that MUF is an efficient way to remove cytokines and AM. However, we were unable to demonstrate any significant impact of MUF in outcome of adults after elective CABG.

Adult↗

Reoperative surgery for degenerated aortic bioprostheses: predictors for emergency surgery and reoperative mortality.

OBJECTIVE: The long-term outcome of patients with aortic bioprosthetic valves could be improved by decreasing the reoperative mortality rate. METHODS: Predictors of emergency reoperation and reoperative mortality were identified retrospectively in 172 patients who had the first bioprosthetic aortic valve replacement between 1975 and 1988 (mean age 46+/-13 years) and were subjected to replacement of the degenerated bioprostheses between 1978 and 1997 (mean age 56+/-14 years). Emergency reoperation had to be performed in 31 patients (18%). RESULTS: The operative mortality was 5.2% (9/172), 22.6% for emergency (odds ratio 11.17; 95%-confidence limit 4.33-28.85) and 1.4% for elective replacement of the degenerated aortic bioprosthesis (P<0.0001; OR=20.3). Patients who died at reoperation had higher transvalvular gradients before the primary aortic valve replacement (P=0.007), received smaller bioprostheses at the first operation (P=0.03), had later recurrence of symptoms after the first aortic valve replacement (P=0.04), a higher pre-reoperative New York Heart Association (NYHA) class (P=0.02), and a higher incidence of coronary artery disease (P=0.001) and pulmonary artery hypertension (P=0.009). Endocarditis before the primary aortic valve replacement (P=0.004), postoperative pneumonia at the first operation (P=0.005), pulmonary hypertension (P=0.0004) acquired during the interval, later recurrence of symptoms (P=0.04) after the first operation, a lower ejection fraction at the time of reoperation (P=0.03) and acute onset of bioprosthetic regurgitation (P=0.00002) were predictors for emergency surgery. Higher transvalvular gradients at the primary aortic valve replacement (P=0. 006), coronary artery disease (P=0.003) acquired during the interval, the need for concomitant coronary artery revascularization (P=0. 001), sex (P=0.02) and size (P=0.05) and type of the bioprostheses used (P=0.007) were incremental predictors for reoperative mortality which were independent of emergency surgery. CONCLUSIONS: Elective replacement of failed aortic bioprostheses is safe. Patients undergoing emergency reoperation have a considerably higher mortality. They can be identified by a history of native aortic valve endocarditis, higher transvalvular gradients at primary aortic valve replacement, smaller bioprostheses, and pulmonary hypertension or coronary artery disease acquired during the interval. A failing bioprosthesis must be replaced at its first sign of dysfunction.

Aortic Valve↗

Affinity pump system: a new peristaltic blood pump for cardiopulmonary bypass.

An in vitro study has been carried out to assess the pump performance of a new peristaltic, extracorporeal displacement pump (Affinity) for cardiopulmonary bypass. The pump system consists of a pump rotor (0-110 rpm), a pump chamber, a venous reservoir with a 5/8" connecting tube and the Affinity console. The polyurethane chamber is connected to the venous reservoir by a 5/8" tube and fills passively due to the hydrostatic pressure exhibited by the fluid height in the venous reservoir. The implementation of an occlusive segment in the pump chamber, which collapses in low filling states, should prevent significant negative pressures. An in vitro circuit was filled with bovine blood (37 degrees C, hematocrit 35%) and the pump flow was measured by an ultrasonic transit time flow probe with respect to pre-load, diameter and length of attached tubing in the venous line, pump speed (rpm) and size of the connecting tube (3/8" and 5/8"). At 108 rpm and a preload equal to 10 mmHg, the flow was 8.6 +/- 0.42 l/min for an afterload of 80 mmHg. The reduction of the inlet connector to 3/8" diminished the pump flow significantly to 5.2 +/- 0.31 l/min (p < 0.0001). The pump flow decreased linearly with respect to the length of the attached tube in the venous line and for a 2 m long 5/8" silicon tube, the rpm-optimized flow was still 6.0 +/- 0.28 l/min at a preload of 10 mmHg. In case of low filling state or too high rpm, the occlusive segment collapsed and no cavitation bubbles could be detected. Our in vitro measurements yield a nomogram for rpm-optimized blood flow with respect to the pre-load in the venous reservoir. The delivered 5/8"connecting tube facilitates optimum filling of the pump chamber for high blood flow, but limits the use of venous reservoirs to Affinity products. The pump yields a high blood flow even when long tubing in the venous line is used. This makes the pump a candidate for a ventricular assist device. In hypovolemia or high rpm, the occlusive segment collapses and no negative pressure is generated at the inflow site of the pump chamber.

Animals↗

Aortopulmonary window with anomalous origin of the right coronary artery.

We report a case of an aortopulmonary window with a right coronary artery arising from the pulmonary trunk. This exceedingly rare anomaly with anomalous coronary artery presented without myocardial ischemia owing to the aortopulmonary window. The correct diagnosis was made by angiography and a successful surgical correction was performed.

Aortopulmonary Septal Defect↗

Complete thromboendarterectomy of the calcified ascending aorta and aortic arch.

BACKGROUND: Arteriosclerotic plaques of the ascending aorta and transverse arch increase the operative risk of cardiac operations and are strong predictors for late cerebrovascular events. METHODS: Twenty-two patients, mean age 68 +/- 6 years (range, 55 to 77 years), with grade IV + V plaques of the ascending aorta and transverse arch underwent coronary artery bypass grafting (n = 21) and aortic valve replacement (n = 8). Cerebrovascular emboli from unknown sources were found preoperatively in 8 patients (36%). All were in sinus rhythm. Complete thromboendarterectomy of the ascending aorta and transverse arch was performed during hypothermic circulatory arrest. After 21 +/- 12 months (range, 4 to 44 months), magnetic resonance imaging and transthoracic echocardiography of endarterectomized vessels was performed. RESULTS: There was one perioperative death (4.5%), one early (4.5%), and one late (4.7%) adverse neurologic event. Follow-up examinations revealed normal diameters of the endarterectomized aorta. CONCLUSIONS: For patients with grade IV + V plaques, thromboendarterectomy of the ascending aorta and transverse arch can be performed with an acceptable surgical risk and a low recurrence rate for cerebrovascular events. Dilatation of the endarterectomized aorta was not observed.

Aged↗