PubMed Health⌕ Search

Biomedical subjects

G Zünd

Publications and source records attributed to G Zünd.

At least 37 records · Page 2Linked to original sources

Explanted cryopreserved allografts: a morphological and immunohistochemical comparison between arterial allografts and allograft heart valves from infants and adults.

OBJECTIVE: Life expectancy of cryopreserved allografts implanted in infants is different from those implanted in adults. A morphological study of explanted allograft heart valves was performed to determine the mechanism of deterioration and to compare cryopreserved arterial and heart valve allografts from adult patients with those explanted from infants. METHOD: Between 1987 and 1996, 209 cryopreserved allografts were implanted: 125 valved conduits or monocusps to reconstruct the right ventricular outflow tract in congenital heart disease, 50 allograft heart valves to treat native aortic and prosthetic aortic valve endocarditis and 34 cryopreserved arterial allografts to replace mycotic aortic aneurysms or infected aortic prosthetic grafts. Two months to 8 years after implantation, 23 heart valve allografts, 11 right-sided and 12 left-sided, and four arterial allografts had to be explanted for reasons such as degeneration, recurrent infection, aneurysm formation or rupture. Besides conventional staining, immunohistochemical detection of cell populations was performed as follows: CD45RO, CD3 and CD43 for T lymphocytes, CD20 for B lymphocytes, CD68 for macrophages, protein S100 for Langerhans-cells, vimentin for fibroblasts, alpha-actin for smooth muscle cells and factor VIII for endothelial cells. RESULTS: Explanted cryopreserved allografts were all fibrotic, acellular, non-vital and without endothelial cells. The fibrous tissue was preserved. T lymphocytes, indicating rejection, were found in all right-sided allografts from the paediatric population, but only in 9% of left-sided valves explanted from adults and in one of the four of arterial allografts. Macrophages and Langerhans-cells were found only in right-sided allografts from paediatric patients. CONCLUSION: Right-sided cryopreserved allografts from a paediatric population showed ongoing cellular rejection. By contrast, there was only a weak T-cell mediated rejection to adult heart valve and arterial allografts. Therefore, similar long-term results can be expected in adult arterial and heart valve allografts, whereas longevity of right-sided heart valve allograft in the paediatric age group seems endangered by cellular rejection.

Adolescent↗

Conservative treatment of the aortic root in acute type A dissection.

OBJECTIVE: In acute type A dissection long-term results of conservative aortic root surgery were compared with the outcome of primary valve and/or root replacement. METHODS: Between 1985 and 1995, 199 patients (mean age 59 years, 154 men) were operated on. The aortic root was involved in the dissection process and valve incompetence of varying degree was present without exception. Replacement of a proximal aortic segment was standard procedure in all patients. The aortic valve was preserved in 126 patients: commissural suture resuspension (12 patients), root reconstruction with GRF-glue (gelatine-resorcin-formaldehyde/glutaraldehyde-glue) (114 patients). Valve replacement was performed in 73 patients (50 composite grafts, 23 valve prostheses with separate supracoronary grafts). Preoperative risk factors (valve replacement vs. preservation): coronary artery disease (11 vs. 8%, NS), tamponade (18 vs. 17%, NS), unstable hemodynamics (22 vs. 15%, NS), renal failure (4 vs. 6%, NS), neurologic disorder (19 vs. 32%, NS). RESULTS: The overall early mortality was 23.6% (47/199 patients) and increased after commissural suture resuspension compared with GRF-glue reconstruction (P = NS). Parameters of the early postoperative period did not differ between conservative treatment and root/valve replacement: low cardiac output, 34 versus 38% (P = NS); myocardial infarction, 10 versus 11% (P = NS); hemorrhage, 25 versus 23% (P = NS); duration of intensive care (P = NS). Survival was 61% after 8 years without difference between the two principal treatment groups (P = NS) and between the two conservative subgroups (P = NS). At 2 years, GRF-glue reconstruction had an increased freedom from reoperation on the aortic root (92 vs. 70%, P = 0.0253) and event free survival (77 vs. 41%, P = 0.0224) compared with suture resuspension. Commissural suture resuspension was an independent, significant predictor for reoperation (P = 0.0221, relative risk = 4.7130). CONCLUSION: Surgery for acute type A dissection still carries a considerable early risk. Preservation of the aortic root is safe in the absence of Marfan or annuloaortic ectasia, but a certain incidence of reoperations on the aortic valve and the aortic root has to be accepted. Root reconstruction using GRF-glue is the method of choice and is superior to suture resuspension, with a significantly better reoperation-free and event-free survival.

Acute Disease↗

Flow measurements through aortocoronary and intraluminal coronary shunts.

AIMS: Temporary insertion of shunts during coronary artery bypass grafting (CABG) on the beating heart may provide the minimal flow required for adequate myocardial protection (40 to 60 ml/min). We investigated the flow as a function of the pressure head over three aortocoronary shunts and one intraluminal coronary shunt. METHODS: The aortocoronary shunts (VS-01590 with bulb size 2, 3 and 4 mm) and the intraluminal shunt (IVS-4030, bulb size 4 mm) were perfused with 47% glycerin solution at 37 degrees C. The preload was raised in 5 mmHg steps from 35 to 80 mmHg. The afterload was set at 12 mmHg. A regression analysis of the flow on the pressure head was performed. RESULTS: For maximal preload the flow through the aortocoronary shunts was 15.9 +/- 1.3, 46.2 +/- 2.2 and 75.4 +/- 3.3 ml/min, for the intraluminal shunt it was 76.1 +/- 3.4 ml/min. To provide a flow of 40 ml/min a preload of 70, 50 and 45 mmHg was necessary for the 3 mm and 4 mm aortocoronary shunt and the intraluminal shunt respectively. For the aortocoronary and the intraluminal shunts the beta-coefficients were 0.27, 0.66, 1.13 and 1.02 ml/(min*mmHg) respectively with all p < 0.0001. CONCLUSIONS: For adequate pressure head the 3 mm and 4 mm aortocoronary shunt and the intraluminal shunt provide myocardial protection. In case of severe proximal coronary stenosis the intraluminal shunt will not guarantee myocardial protection and main benefit reduces to working in a bloodless field. The insertion of shunts is a cheap and simple method to optimize CABG on the beating heart.

Arteriovenous Shunt, Surgical↗

Optimized performance of the Abiomed BVS 5000: adjustment of the pump height based on Doppler control of the flow pattern.

The Abiomed BVS 5000 is an automatic volume-driven paracorporeal pulsatile assist device providing left, right or biventricular support. The paracorporeal position allows optical adjustment of filling volumes of the device, which determines the output of the system. A procedure to adjust for maximal stable flow has not yet been established. In vitro measurements have been performed to assess the flow and pressure characteristics of the Abiomed BVS 5000 by raising the preload in 5 mmHg steps before running the system. Doppler probes were placed at the inflow and outflow lines of the pump. After setting the afterload at 80 mmHg the assist device was started. Two measurements were performed to find optimal flow (based on Doppler control and optical adjustment). (1) By Doppler control a stable flow pattern was found at a preload of 25 mmHg with a mean atrial pressure of 5 mmHg and a mean flow of 5.3 +/- 0.7 l/min (mean +/- standard deviation) at the inflow and outflow sites (the console flow was 4.8 +/- 0.4 l/min with a frequency of 61.8 +/- 2.0 l/min). (2) Optical adjustment of the pump height gave rise to a preload of 35 mmHg where we recorded a maximal atrial pressure of 107 +/- 5.8 mmHg, a maximal retrograde flow of -4.3 +/- 1.2 l/min at the inflow and -1.2 +/- 0.4 l/min at the outflow site. The mean flow at the inflow and outflow sites was 5.1 +/- 0.5 l/min (the console flow was 4.6 +/- 0.3 l/min with a frequency of 59.6 +/- 2.6 Hz). At an initial afterload of 60 and 40 mmHg the system showed the same qualitative behaviour, but the results were less accurate. Optical adjustment of the pump height may result in an atrioventricular valve insufficiency with undetected retrograde flow and high atrial pressures. We conclude that a Doppler flow probe must be placed at the inflow site to guarantee maximal stable flow.

Equipment Design↗

Hemodynamic properties of the hemopump HP14.

BACKGROUND: The Hemopump HP14 is a catheter-mounted, transvalvular, left ventricular assist device intended for femoral percutaneous insertion. The pump was developed for patients with postoperative or postinterventional low cardiac output and for CABG surgery on the beating heart. Little is known about the effect of afterload and hematocrit on the pump performance. METHODS: The influence of hematocrit and afterload on the pump flow was tested using an in vitro model filled with heparinized bovine blood. Regression analysis of the pump flow with respect to three hematocrit values (20%, 30%, 40%) and ten afterload levels (30 mmHg-120 mmHg in 10 mmHg increments) was performed for all pump speed levels (n = 7). RESULTS: At all pump speed levels reduction of afterload and hematocrit were significant predictors for increasing pump flow (p<0.001). For hematocrit values between 40% and 20% and highest pump speed, mean pump flow at lowest afterload ranged between 2.34 and 2.53 L/min; and at highest afterload between 1.31 and 1.53 L/min. For speed level 1, afterload of 120 mmHg and hematocrit of 40% there was a maximal retrograde flow of 230+/-35 ml/min. CONCLUSIONS: Pump performance is significantly improved by both afterload and hematocrit reduction. In the weaning phase and during the removal of the device, the pump should run at a speed level of at least three to prevent retrograde flow in the pump. Estimates for pump flow in vivo can be extrapolated from our diagrams. Our results show that the Hemopump HP14 is a valuable alternative to intra-aortic balloon counterpulsation.

Animals↗

Fluorescence activated cell sorting: a reliable method in tissue engineering of a bioprosthetic heart valve.

BACKGROUND: Techniques of tissue engineering are used to seed human autologous cells in vitro on degradable mesh to create new functional tissue like a bioprosthetic heart valve. A precondition is subsequent seeding of native-valve-analogous pure endothelial and myofibroblast cell lines. The aim of this study is to find a safe method of isolating viable cell lines out of tissues from the operating room. METHODS: Mixed cells from ascending aorta obtained from the operating room were incubated with an endothelial-specific fluorescent marker. The labeled cells were activated and sorted by flow cytometry. Isolated cell lines were cultured and thereafter square sheets of polymeric scaffold were seeded with myofibroblasts, followed by endothelial cells. The created tissue was stained with hematoxylin and eosin, van Gieson stain, and stains for factor VIII and CD34. RESULTS: Control culture samples (n = 25) revealed vital uncontaminated endothelial and myofibroblast cell lines. Microscopy of the seeded meshes (n = 16) demonstrated a tissue-like structure. Van Gieson stain showed production of collagen. Endothelial cells formed a superficial monolayer, demonstrated by factor VIII and CD34; no invasive formation of capillaries was detectable. CONCLUSIONS: These results demonstrate that fluorescence activated cell sorting is a reliable and safe method to gain pure vital autologous cell lines out of human mixed cells for subsequent seeding on degradable mesh and that those cells are active to form new tissue.

Aorta↗

Disadvantages of local repair in acute type A aortic dissection.

BACKGROUND: In acute type A dissection of the aorta, local repair with glue-aortoplasty was compared with aortic replacement. METHODS: Between 1992 and 1996, 106 consecutive patients (mean age, 59 years; 84 men) were operated on average 14.5 hours after onset of dissection. A local repair (gelatin-resorcine-formaldehyde/glutaraldehyde glue, Trigon AG, Monchengladbach, Germany) without graft replacement was performed in 21 patients. Graft replacement and reinforcement of aortic stumps with gelatin-resorcine-formaldehyde/glutaraldehyde glue was performed in 85 patients (supracoronary graft, 68; aortic root replacement, 17). RESULTS: Survival was 79% after 30 days and 69% after 2 years. There was no difference in early mortality (p = 0.2240) and survival (p = 0.07649). Risk factors for early mortality were preoperative shock, neurologic disorder, duration of crossclamp, and extracorporeal circulation. The rate of reoperation on the proximal aorta was 31.6% (6 of 19) after local repair and 9% (6 of 64) after aortic replacement (p = 0.0157). Local repair was a significant predictor for reoperation (p = 0.0087), with decreased reoperation-free survival (p = 0.01164). In all reinterventions (four supracoronary grafts, including two valve replacements; two composite grafts; two arch replacements) breakdown of the aortoplasty was confirmed. CONCLUSION: Local repair has satisfactory early results but an increased incidence of reoperations due to a breakdown of the glue-aortoplasty. Indications for local repair should be restricted to high-risk patients requiring a minimal emergency surgical procedure.

Acute Disease↗

Effect of soluble complement receptor type 1 on reperfusion edema and neutrophil migration after lung allotransplantation in swine.

OBJECTIVE: Soluble complement receptor type 1 inhibits complement activation by blocking C3 and C5 convertases of the classical and alternative pathways. We evaluated the effect of soluble complement receptor type 1 on lung allograft reperfusion injury. METHODS: Left lung transplantation was performed in 13 weight-matched pigs (25 to 31 kg) after prolonged preservation (20 hours at 1 degree C). One hour after reperfusion the recipient contralateral right lung was excluded to assess graft function only. Complement activity and C3a levels were measured after reperfusion and at the end of the assessment. Extravascular lung water index, intrathoracic blood volume, and cardiac output were assessed during a 5-hour observation period. Gas exchange and hemodynamics were monitored. At the end of the 5-hour assessment period, myeloperoxidase assay and bronchoalveolar lavage were performed to assess neutrophil migration, and C5b-9 (membrane attack complex) deposits in the allograft were detected by immunohistochemistry. Two groups were studied. In group II (n = 6) recipient animals were treated with soluble complement receptor type 1 (15 mg/kg) 15 minutes before reperfusion. Group I (n = 7) served as the control group. RESULTS: Serum complement activity was completely inhibited in group II. In contrast to group I, C5b-9 complexes were not detected in group II allograft tissue samples. C3a was reduced to normal levels in group II (p = 0.00005). Extravascular lung water index was higher in group I animals throughout the assessment period (p = 0.035). No significant difference in allograft myeloperoxidase activity (p = 0.10) and polymorphonuclear leukocyte count of the bronchoalveolar lavage fluid (p = 0.057) was detected. CONCLUSION: Inhibition of the complement system by soluble complement receptor type 1 blocks local complement activation in the allograft and reduces posttransplantation reperfusion edema but does not improve hemodynamic parameters.

Animals↗

Tissue engineering: a new approach in cardiovascular surgery: Seeding of human fibroblasts followed by human endothelial cells on resorbable mesh.

OBJECTIVE: In tissue engineering the material properties of synthetic compounds are chosen to enable delivery of dissociated cells onto a scaffold in a manner that will result in in vitro formation of a new functional tissue. The seeding of human fibroblasts followed by human endothelial cells on resorbable mesh is a precondition of a successful creation of human tissues such as vessels or cardiac valves. METHODS: Polymeric scaffolds (n = 18) composed of polyglycolic acid (PGA) with a fiber diameter of 12-15 microm and a polymer density of 70 mg/ml were used as square sheets of 1 x 1 x 0.3 cm. Fibroblasts (passage 7) harvested from human foreskin were seeded (3.4 x 10(6)) and cultured over a 3 week period on a PGA-mesh, followed by seeding of endothelial cells (passage 5, 2.8 x 10(6)) harvested from human ascending aorta. Thereafter the new tissue was stained for HE, van Gieson, Trichrom Masson, Factor VIII and CD 34 and proved by scanning electron microscopy. RESULTS: Microscopic examination of the seeded mesh demonstrated that the human fibroblasts were attached to the polymeric fibers and had begun to spread out and divide. The scanning electron microscopic examination demonstrated a homogeneous scaffold resembling a solid sheet of tissue. The seeded endothelial cells formed a monolayer on the fibroblasts and no endothelial cell invasion or new formation of capillaris could be detected. CONCLUSIONS: These results are a first step to demonstrate that seeding of human fibroblasts and endothelial cells on PGA-mesh might be a feasible model to construct human tissues such as vessels or cardiac valves.

Aorta↗

Composite graft replacement of the aortic root in acute dissection.

OBJECTIVE: In acute type A dissection the indication for composite graft replacement of the aortic root and the optimal implantation technique are a matter of debate. In this study early and late results of root replacement in acute dissection are determined and compared with supracoronary graft replacement. Two implantation techniques (open vs. inclusion) are evaluated. METHODS: Between 1985 and 1995, 207 consecutive patients (mean age 58 +/- 12 years, 78% men) were operated for acute type A dissection of the aorta. Root replacement in 50 patients (inclusion technique in 34/50 patients with Cabrol shunt in 15/34 patients, open technique in 16/50 patients) was compared with more conservative procedures in 157 patients: supracoronary graft replacement in 143 patients (with aortic valve replacement in 23 patients) and local repair without graft interposition in 14 patients. Preoperative risk factors, like hemodynamic instability, renal failure, neurologic disorder and coronary artery disease did not differ in the two treatment groups. RESULTS: Early results, survival and reoperation-free survival after 5 years were insignificantly better after root replacement: mortality 10/50 (20%) vs. 38/157 (24%) P = n.s.; hemorrhage 10/50 (20%) vs. 39/157 (25%) P = n.s.; stroke 5/50 (10%) vs. 27/157 (17%) P = n.s.; survival 70 +/- 7% vs. 63 +/- 4%, reoperation free survival 92 +/- 6% vs. 78 +/- 5% P = 0.0815). For the open technique, early mortality was 18.8 vs. 20.6%, P = n.s. and reoperation free survival at 5 years was 80.7 vs. 65.2%, P = n.s. Perioperative complications did not differ in the two technical groups and a single pseudoaneurysm occurred in the Bentall group. CONCLUSION: In acute dissection composite graft replacement of the aortic root can be carried out with good early and late results not inferior to more conservative procedures. The open technique is the implantation method of choice and the modified Bentall technique is indicated in situations with increased risk of bleeding.

Acute Disease↗

Endothelial cell injury in cardiac surgery: salicylate may be protective by reducing expression of endothelial adhesion molecules.

OBJECTIVE: Cardiac surgery with cardiopulmonary bypass induces ischemia to the heart, hypoxemia to various tissues and release of endotoxins. The endothelial cell may suffer from hypoxia and trigger cascades of adverse reactions by activation of neutrophils through adhesion molecules. The authors measured expression of intercellular adhesion molecule-1 (ICAM-1), during hypoxia and normoxia and hypothesized that salicylate, which inhibits the nuclear factor-kappaB (NFkappaB), an hypoxia-dependent transmission factor, could reduce this expression. METHODS: Human umbilical vein endothelial cells were cultured and exposed to normoxia and hypoxia in the presence of lipopolysaccharide (LPS). The endothelial cells were thereafter treated with salicylate or indomethacin under the same conditions. The surface expression of ICAM-1 was measured by whole cell enzyme-linked immunosorbent assay (ELISA) and the NFkappaB expression by Western blotting. RESULTS: In the presence of LPS and under hypoxic conditions, the endothelial cells produced a 300 +/- 41% increased expression of ICAM-1 compared with normoxia. The addition of salicylate (0.02-20 mM) completely inhibited the enhanced expression of ICAM-1, the addition of indomethacin at equivalent concentrations did not reduce ICAM-1 expression under either condition. CONCLUSION: ICAM-1 expression is greatly enhanced by the hypoxic endothelial cell in the presence of circulating endotoxin. Pre-treatment with salicylate completely abolishes the enhanced expression. The study suggests that salicylate administered before cardiopulmonary bypass might protect the heart against ischemic/reperfusion injuries and reduce the load of the overall inflammatory reaction.

Blotting, Western↗

Preoperative predictors of recurrent atrial fibrillation late after successful mitral valve reconstruction.

OBJECTIVE: Late outcome after mitral valve repair was examined to define preoperative predictors of recurrent atrial fibrillation late after successful mitral valve reconstruction. METHODS: One hundred and eighty-nine patients, 112 with preoperative sinus rhythm and 72 with preoperative chronic or intermittent atrial fibrillation, were followed for 12.2 +/- 10 years after valve repair. Clinic, hemodynamic end echocardiographic data were entered into Cox-regression and Kaplan-Meyer analysis to assess predictors for recurrent atrial fibrillation late after successful mitral valve repair. RESULTS: Univariate and multivariate predictors for recurrent atrial fibrillation late after successful mitral valve reconstruction were preoperative atrial fibrillation (P = 0.0001), preoperative antiarrhythmic drug treatment (P = 0.005), heart rate (P = 0.01), left ventricular ejection fraction (P = 0.01) and increased left ventricular posterior wall thickness (P = 0.05). Patients > 57.5 years with a mean pulmonary artery pressure > or =23 mm Hg and a history of preoperative antiarrhythmic drug treatment had an odds ratio of 53.33 (95% confidence limits 6.12-464.54) for atrial fibrillation late after successful mitral valve repair. CONCLUSION: Older patients with a history of atrial fibrillation, antiarrhythmic treatment or an elevated pulmonary artery pressure may present atrial fibrillation late after successful mitral valve repair. They could be considered for combined mitral valve reconstruction and surgery for atrial fibrillation even though sinus rhythm is present preoperatively.

Adult↗

[How to do: initial experiences with a new device in minimally invasive heart surgery].

A special surgical technique is required for minimal-invasive cardiac surgery. The view for the coronary artery anastomosis under beating heart conditions is important and coronary artery blood might prevent a clear view of the opened coronary artery vessel. A new system called VisoFlo promises to improve visualisation at the surgical site. VisoFlo delivers a column of air to help provide a clear view of anastomosis site and in addition has a controllable mist to help prevent desiccation of the graft and surrounding tissue. This system was tested on 45 patients with coronary-artery-bypass graft surgery under beating heart conditions and at 65 patients with standard coronary-artery-bypass graft surgery. Our conclusions are, that the VisoFlo system is easy to use, guarantees a clear view of the anastomosis site and the surgical work will not be impaired.

Anastomosis, Surgical↗