PubMed Health⌕ Search

Biomedical subjects

Gabriel Montaldo

Publications and source records attributed to Gabriel Montaldo.

5 recordsLinked to original sources

Spatio-temporal coding in complex media for optimum beamforming: the iterative time-reversal approach.

Spatio-temporal encoding in transmit and receive modes is of major importance in the development of ultrasound imaging devices. Classically, the assumption of constant sound speed in the medium allows one to restrict the beamforming process to the application of a cylindrical time-delay law on the elements of a multiple-transducer array. Here is proposed an iterative time-reversal method capable of taking into account all the heterogeneities of the medium, concerning density, speed of sound, and absorption variations. It will be shown that this iterative focusing process converges toward a spatio-temporal inverse filter focusing, the first step of the process being a time-reversal focusing on the targeted point. This method can be seen as a calibration process and has been successfully applied to transskull focusing and intraplate echoes suppression. It is leading the way to promising applications such as high-resolution ultrasonic brain imaging and high-resolution focusing through complex reverberating media, in nondestructive testing and telecommunications. This work highlights the advantages of using spatio-temporal coding to focus through complex media. Such codes require the use of fully programmable, multichannel electronics to implement this technique in real time.

Echoencephalography↗

Building three-dimensional images using a time-reversal chaotic cavity.

The design of two-dimensional (2-D) arrays for three-dimensional (3-D) ultrasonic imaging is a major challenge in medical and nondestructive applications. Thousands of transducers are typically needed for focusing and steering in a 3-D volume. In this article, we propose a different concept allowing us to obtain electronic 3-D focusing with a small number of transducers. The basic idea is to couple a small number of transducers to a chaotic reverberating cavity with one face in contact with the body of the patient. The reverberations of the ultrasonic waves inside the cavity create at each reflection virtual transducers. The cavity acts as an ultrasonic kaleidoscope multiplying the small number of transducers and creating a much larger virtual transducer array. By exploiting time-reversal processing, it is possible to use collectively all the virtual transducers to focus a pulse everywhere in a 3-D volume. The reception process is based on a nonlinear pulse-inversion technique in order to ensure a good contrast. The feasibility of this concept for the building of 3-D images was demonstrated using a prototype relying only on 31 emission transducers and a single reception transducer.

Echocardiography, Three-Dimensional↗

Real time inverse filter focusing through iterative time reversal.

In order to achieve an optimal focusing through heterogeneous media we need to build the inverse filter of the propagation operator. Time reversal is an easy and robust way to achieve such an inverse filter in nondissipative media. However, as soon as losses appear in the medium, time reversal is not equivalent to the inverse filter anymore. Consequently, it does not produce the optimal focusing and beam degradations may appear. In such cases, we showed in previous works that the optimal focusing can be recovered by using the so-called spatiotemporal inverse filter technique. This process requires the presence of a complete set of receivers inside the medium. It allows one to reach the optimal focusing even in extreme situations such as ultrasonic focusing through human skull or audible sound focusing in strongly reverberant rooms. But, this technique is time consuming and implied fastidious numerical calculations. In this paper we propose a new way to process this inverse filter focusing technique in real time and without any calculation. The new process is based on iterative time reversal process. Contrary to the classical inverse filter technique, this iteration does not require any computation and achieves the inverse filter in an experimental way using wave propagation instead of computational power. The convergence from time reversal to inverse filter during the iterative process is theoretically explained. Finally, the feasibility of this iterative technique is experimentally demonstrated for ultrasound applications.

Journal Article↗

Revisiting iterative time reversal processing: application to detection of multiple targets.

The iterative time reversal processing represents a high speed and easy way to self-focus on the strongest scatterer in a multitarget medium. However, finding weaker scatterers is a more difficult task that can be solved by computing the eigenvalue and eigenvector decomposition of the time reversal operator, the so-called DORT method. Nevertheless, as it requires the measurement of the complete interelements response matrix and time-consuming computation, the separation of multiple targets may not be achieved in real time. In this study, a new real time technique is proposed for multitarget selective focusing that does not require the experimental acquisition of the time reversal operator. This technique achieves the operator decomposition using a particular sequence of filtered waves propagation instead of computational power. Due to its simplicity of implementation, this iterative process can be achieved in real time. This high speed selective focusing is experimentally demonstrated by detecting targets through a heterogeneous medium and in a speckle environment. A theoretical analysis compares this technique to the DORT formalism.

Journal Article↗

Time-reversal acoustics in biomedical engineering.

Time reversal is a very powerful method for focusing through complex and heterogeneous media and shows very promising results in biomedical applications. In this paper, we review some of the main applications investigated during the past decade. An iterative implementation of the time-reversal process allows tracking gallstones in real time during lithotripsy treatments. In this application domain, a smart exploitation of the reverberations in solid waveguides permits the focusing of high-amplitude ultrasonic shock waves with a small number of transducers. Finally, because time reversal is able to correct the strong distortions induced by the skull bone on ultrasonic propagation, this adaptive focusing technique is very promising for ultrasonic hyperthermia brain therapy.

Acoustics↗