PubMed Health⌕ Search

PubMed · 15801310

Spatio-temporal coding in complex media for optimum beamforming: the iterative time-reversal approach.

Abstract

Spatio-temporal encoding in transmit and receive modes is of major importance in the development of ultrasound imaging devices. Classically, the assumption of constant sound speed in the medium allows one to restrict the beamforming process to the application of a cylindrical time-delay law on the elements of a multiple-transducer array. Here is proposed an iterative time-reversal method capable of taking into account all the heterogeneities of the medium, concerning density, speed of sound, and absorption variations. It will be shown that this iterative focusing process converges toward a spatio-temporal inverse filter focusing, the first step of the process being a time-reversal focusing on the targeted point. This method can be seen as a calibration process and has been successfully applied to transskull focusing and intraplate echoes suppression. It is leading the way to promising applications such as high-resolution ultrasonic brain imaging and high-resolution focusing through complex reverberating media, in nondestructive testing and telecommunications. This work highlights the advantages of using spatio-temporal coding to focus through complex media. Such codes require the use of fully programmable, multichannel electronics to implement this technique in real time.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gabriel Montaldo, Jean-François Aubry, Mickaël Tanter, Mathias Fink. 2005. Spatio-temporal coding in complex media for optimum beamforming: the iterative time-reversal approach.. https://doi.org/10.1109/tuffc.2005.1406548

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thymus involution and cerebral white matter damage in extremely low gestational age neonates.

BACKGROUND: Among newborns who die, those who have cerebral white matter damage are more likely than others to have thymus involution and low thymus weights. OBJECTIVE: We sought to evaluate in a population of preterm newborns who did not die if those who developed a cerebral white matter damage (as defined by an echolucency) are more likely than others to have thymus involution as assessed on chest radiographs. METHOD: The 89 infants whose data were evaluated were born before the 28th week of gestation, had at least one chest radiograph within the first 2 days of life (to determine thymus size), and at least one cranial ultrasonogram to assess for white matter echolucency. RESULTS: Eighty-five percent of these infants had a small thymus within the first 2 weeks of life. Median time to thymus involution in those born before the 26th week of gestation was 36 h, and in those born during or after the 26th week of gestation was 140 h. Infants who developed involution before the median time in their respective gestational age groups were classified as early involuters (group 1) and were compared to their peers with late/no involution (group 2). Infants with an echolucency were more likely to have had early involution than infants without an echolucency (89% vs. 44%) (p = 0.01). This relationship was not distorted by potential confounders. The echolucency odds ratio associated with early thymus involution was consistently above 8 in all strata of the sample. CONCLUSION: These results are consistent with the possibility that early thymus involution and neonatal white matter damage are not independent phenomena and may have common antecedents.

Echoencephalography↗