PubMed Health⌕ Search

Biomedical subjects

Ge Wang

Publications and source records attributed to Ge Wang.

18 recordsLinked to original sources

Engineering local nitrogen coordination environments of Palladium subnanometric clusters in metal-organic frameworks for efficient hydrogenation.

Subnanometric clusters (SCs) bridge the gap between single-atom catalysts and nanoparticles by combining high atomic utilization with cooperative multi-atom effects. However, stabilizing low-coordinated SCs while maintaining accessible active sites remains challenging. Here, we introduce pyrazole-3,5-dicarboxylic acid (PZDC), pyridine-3,5-dicarboxylic acid (PDC), and pyrrole-3,5-dicarboxylic acid (PPy) as secondary ligands in metal-organic frameworks to regulate the local nitrogen (N) coordination environment of Pd SCs (∼0.6 nm). Specifically, PZDC provides a chemically differentiated pyrazolic dual-N environment containing formally pyridinic-like and pyrrolic-like N sites. Aberration-corrected high-angle annular dark-field scanning transmission electron microscopy (AC HAADF-STEM) and X-ray absorption spectroscopy (XAS) confirm the formation of low-coordinated Pd clusters containing PdN and PdPd interactions, while CO diffuse reflectance infrared Fourier transform spectroscopy (CO-DRIFTS) reveals a distinctive adsorption environment characterized by geminal dicarbonyl species and strongly suppressed bridge-bonded CO adsorption. Within this catalyst series, the PZDC-functionalized material exhibits the highest activity and tetrahydrocyclopentadiene (THDCPD) selectivity in dicyclopentadiene (DCPD) hydrogenation. These results demonstrate that modification of the local N environment can regulate the average coordination structure, adsorption behavior, and catalytic properties of MOF-supported Pd SCs.

Hydrogenation catalysis↗

Controlled framework nickel exsolution in metal-organic frameworks creates confined active sites for chemoselective citral hydrogenation.

Selective hydrogenation of citral to citronellal over non-noble-metal catalysts remains challenging because highly active metallic Ni simultaneously promotes efficient substrate activation and undesired over‑hydrogenation of the desired product. Herein, we develop a controlled exsolution strategy in waste polyethylene terephthalate (PET)-derived nickel metal-organic frameworks (Ni-MOFs) to transform framework Ni into confined metallic active sites while preserving the porous framework architecture. During reductive treatment, framework Ni2+ species undergo gradual node-to-metal evolution, generating highly dispersed Ni0 sites confined within the partially retained MOF framework. More importantly, the degree of framework Ni exsolution governs the balance between citral activation and citronellal over‑hydrogenation, thereby establishing a distinct chemoselective window. Within the optimal exsolution regime, the framework-confined Ni0 sites enable efficient H2 activation and selective hydrogenation of the CC bond while suppressing the subsequent hydrogenation of citronellal. Consequently, the optimized catalyst achieves ∼99% citral conversion and 100% citronellal selectivity at 90 °C and 2 MPa H2, together with excellent catalytic stability and recyclability. Beyond the sustainable valorization of waste PET, this work establishes controlled framework exsolution as an effective strategy for engineering confined active sites and regulating chemoselectivity in non-noble-metal hydrogenation catalysts.

Chemoselective hydrogenation↗

C-terminal amino acids of Helicobacter pylori alpha1,3/4 fucosyltransferases determine type I and type II transfer.

The alpha1,3/4 fucosyltransferase (FucT) enzyme from Helicobacter pylori catalyzes fucose transfer from donor GDP-beta-l-fucose to the GlcNAc group of two series of acceptor substrates in H. pylori lipopolysaccharide: betaGal1,3betaGlcNAc (Type I) or betaGal1,4betaGlcNAc (Type II). Fucose is added either in alpha1,3 linkage of Type II acceptor to produce Lewis X or in alpha1,4 linkage of Type I acceptor to produce Lewis A, respectively. H. pylori FucTs from different strains have distinct Type I or Type II substrate specificities. FucT in H. pylori strain NCTC11639 has an exclusive alpha1,3 activity because it recognizes only Type II substrates, whereas FucT in H. pylori strain UA948 can utilize both Type II and Type I acceptors; thus it has both alpha1,3 and alpha1,4 activity, respectively. To identify elements conferring substrate specificity, 12 chimeric FucTs were constructed by domain swapping between 11639FucT and UA948FucT and characterized for their ability to transfer fucose to Type I and Type II acceptors. Our results indicate that the C-terminal region of H. pylori FucTs controls Type I and Type II acceptor specificity. In particular, the highly divergent C-terminal portion, seven amino acids DNPFIFC at positions 347-353 in 11639FucT, and the corresponding 10 amino acids CNDAHYSALH at positions 345-354 in UA948FucT, controls the Type I and Type II acceptor recognition. This is the opposite of mammalian FucTs where acceptor preference is determined primarily by the N-terminal residues in the hypervariable stem domain.

Amino Acid Sequence↗

Spatial variation of resolution and noise in multi-detector row spiral CT.

RATIONALE AND OBJECTIVES: The authors performed this study to evaluate an approach for measuring the variations of three-dimensional spatial resolution and image noise throughout a field of view imaged with multi-detector row spiral computed tomographic (CT) scanners. MATERIALS AND METHODS: The authors designed a phantom (diameter, 320 mm) that contained 37 metallic spheres (diameter, approximately 0.8 mm) positioned between two disks made of a material with attenuation being that of water. One sphere was located at the isocenter of the phantom, and the rest were evenly spaced in three concentric rings with diameters of 100, 200, and 300 mm, respectively. The phantom was imaged with two widely used multi-detector row CT scanners by using a standard protocol and four variations of that protocol. Because a recently developed theory holds that image resolution should be proportional to the square root of the trace of the covariance matrix of a point spread function, the authors developed a software package to segment high-attenuation spheres from the CT image volume and compute point spread functions from blurred images of the spheres. Three-dimensional spatial resolution and image noise were calculated as a function of radial distance within the field of view. RESULTS: Resolution and noise were quantified in the resultant CT image volumes and found to be nonisotropic, with worse resolution and less noise occurring at the periphery of the field of view. CONCLUSION: The method enabled measurement of variations in spatial resolution and of their distribution on images obtained with multi-detector row CT scanners. These findings may contribute to the development of an improved algorithm for image reconstruction.

Humans↗

Convergence studies on iterative algorithms for image reconstruction.

We introduce a general iterative scheme for image reconstruction based on Landweber's method. In our configuration, a sequential block-iterative (SeqBI) version can be readily formulated from a simultaneous block-iterative (SimBI) version, and vice versa. This provides a mechanism to derive new algorithms from known ones. It is shown that some widely used iterative algorithms, such as the algebraic reconstruction technique (ART), simultaneous ART (SART), Cimmino's, and the recently designed diagonal weighting and component averaging algorithms, are special examples of the general scheme. We prove convergence of the general scheme under conditions more general than assumed in earlier studies, for its SeqBI and SimBI versions in the consistent and inconsistent cases, respectively. Our results suggest automatic relaxation strategies for the SeqBI and SimBI versions and characterize the dependence of the limit image on the initial guess. It is found that in all cases the limit is the sum of the minimum norm solution of a weighted least-squares problem and an oblique projection of the initial image onto the null space of the system matrix.

Algorithms↗

Blind deblurring of spiral CT images.

To discriminate fine anatomical features in the inner ear, it has been desirable that spiral computed tomography (CT) may perform beyond their current resolution limits with the aid of digital image processing techniques. In this paper, we develop a blind deblurring approach to enhance image resolution retrospectively without complete knowledge of the underlying point spread function (PSF). An oblique CT image can be approximated as the convolution of an isotropic Gaussian PSF and the actual cross section. Practically, the parameter of the PSF is often unavailable. Hence, estimation of the parameter for the underlying PSF is crucially important for blind image deblurring. Based on the iterative deblurring theory, we formulate an edge-to-noise ratio (ENR) to characterize the image quality change due to deblurring. Our blind deblurring algorithm estimates the parameter of the PSF by maximizing the ENR, and deblurs images. In the phantom studies, the blind deblurring algorithm reduces image blurring by about 24%, according to our blurring residual measure. Also, the blind deblurring algorithm works well in patient studies. After fully automatic blind deblurring, the conspicuity of the submillimeter features of the cochlea is substantially improved.

Algorithms↗

A pointwise limit theorem for filtered backprojection in computed tomography.

Computed tomography (CT) is one of the most important areas in the modern science and technology. The most popular approach for image reconstruction is filtered backprojection. It is essential to understand the limit behavior of the filtered backprojection algorithms. The classic results on the limit of image reconstruction are typically done in the norm sense. In this paper, we use the method of limited bandwidth to handle filtered backprojection-based image reconstruction when the spectrum of an underlying image is not absolutely integrable. Our main contribution is, assuming the method of limited bandwidth, to prove a pointwise limit theorem for a class of functions practically relevant and quite general. Further work is underway to extend the theory and explore its practical applications.

Algorithms↗

A Grangeat-type half-scan algorithm for cone-beam CT.

Modern CT and micro-CT scanners are rapidly moving from fan-beam toward cone-beam geometry. Half-scan CT algorithms are advantageous in terms of temporal resolution, and widely used in fan-beam and cone-beam geometry. While existing half-scan algorithms for cone-beam CT are in the Feldkamp framework, in this paper we compensate missing data explicitly in the Grangeat framework, and formulate a half-scan algorithm in the circular scanning case. The half-scan spans 180 degrees plus two cone angles that guarantee sufficient data for reconstruction of the midplane defined by the source trajectory. The smooth half-scan weighting functions are designed for the suppression of data inconsistency. Numerical simulation results are reported for verification of our formulas and programs. This Grangeat-type half-scan algorithm produces excellent image quality, without off-mid-plane artifacts associated with Feldkamp-type half-scan algorithms. The Grangeat-type half-scan algorithm seems promising for quantitative and dynamic biomedical applications of CT and micro-CT.

Algorithms↗

Blind deblurring of spiral CT images-comparative studies on edge-to-noise ratios.

A recently developed blind deblurring algorithm based on the edge-to-noise ratio has been applied to improve the quality of spiral CT images. Since the discrepancy measure used to quantify the edge and noise effects is not symmetric, there are several ways to formulate the edge-to-noise ratio. This article is to investigate the performance of those ratios with phantom and patient data. In the phantom study, it is shown that all the ratios share similar properties, validating the blind deblurring algorithm. The image fidelity improvement varies from 29% to 33% for different ratios, according to the root mean square error (RMSE) criterion; the optimal iteration number determined for each ratio varies from 25 to 35. Those ratios that are associated with most satisfactory performance are singled out for the image fidelity improvement of about 33% in the numerical simulation. After automatic blind deblurring with the selected ratios, the spatial resolution of CT is substantially refined in all the cases tested.

Algorithms↗

X-ray micro-CT with a displaced detector array.

Because the sizes of samples differ in x-ray micro-CT applications, it is desirable to have a mechanism to change the field of view of a micro-CT scanner. A well-known way to double the diameter of the field of view is to displace a detector array by 50%. In this paper, we propose to displace a detector array by an amount of greater than 0% but less than 50% for a continuously adjustable field of view, and formulate a weighting scheme for artifact-free reconstruction. Then, we perform numerical simulation with the Shepp-Logan phantom to demonstrate the feasibility in fan-beam and cone-beam geometry.

Computer Simulation↗

A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging.

With the introduction of spiral/helical multislice CT, medical x-ray CT began a transition into cone-beam geometry. The higher speed, thinner slice, and wider coverage with multislice/cone-beam CT indicate a great potential for dynamic volumetric imaging, with cardiac CT studies being the primary example. Existing ECG-gated cardiac CT algorithms have achieved encouraging results, but they do not utilize any time-varying anatomical information of the heart, and need major improvements to meet critical clinical needs. In this paper, we develop a knowledge-based spiral/helical multislice/cone-beam CT approach for dynamic volumetric cardiac imaging. This approach assumes the relationship between the cardiac status and the ECG signal, such as the volume of the left ventricle as a function of the cardiac phase. Our knowledge-based cardiac CT algorithm is evaluated in numerical simulation and patient studies. In the patient studies, the cardiac status is estimated initially from ECG data and subsequently refined with reconstructed images. Our results demonstrate significant image quality improvements in cardiac CT studies, giving clearly better clarity of the chamber boundaries and vascular structures. In conclusion, this approach seems promising for practical cardiac CT screening and diagnosis.

Algorithms↗

Artifacts associated with implementation of the Grangeat formula.

To compensate for image artifacts introduced in approximate cone-beam reconstruction, exact cone-beam reconstruction algorithms are being developed for medical x-ray CT. Although the exact cone-beam approach is theoretically error-free, it is subject to image artifacts due to the discrete nature of numerical implementation. We report a study on image artifacts associated with the Grangeat algorithm as applied to a circular scanning locus. Three types of artifacts are found, which are thorn, wrinkle, and V-shaped artifacts. The thorn pattern is created by inappropriate extrapolation into the shadow zone in the radon domain. If the shadow zone is filled in with continuous data, the thorn artifacts along the boundary of the shadow zone can be removed. The wrinkle appearance arises if interpolated first derivatives of the radon data are not smooth between adjacent detector planes. In particular, the nearest-neighbor interpolation method should not be used. If the number of projections is not small, the bilinear interpolation method is effective to suppress the wrinkle artifacts. The V-shaped artifacts on the meridian plane come from the line integrations through the transition zones where derivative data change abruptly. Two remedies are to increase the sampling rate and suppress data noise.

Algorithms↗

[Rapid induction of mRNAs for liver regeneration genes by hepatopoietin and partial hepatectomy].

OBJECTIVE: To investigate the effect of recombinant human hepatopoietin (rhHPO) and partial hepatectomy on rapidly induced expression of immediate early gene. METHODS: We investigated the different gene expression within 1 hour after 2/3 partial hepatectomy by representational difference analysis and in primary cultured hepatocytes system. RESULTS: In the expressed sequence tag (EST) library, we identified that most of these genes were immediate early gene, and found one new gene PC3 that might be associated to liver regeneration in the EST library. Moreover, PC3 gene was rapidly induced after 2/3 partial hepatectomy and the expressing peak was within 1~2 hours after operation. HPO can rapidly induce the expression of these genes (c-fos, LRF-1, and PC3, etc.) in primarily cultured rat hepatocyte, which might be one of HPO molecular mechanism on stimulating hepatocyte proliferation. CONCLUSIONS: rhHPO and partial hepatectomy can rapidly induce the expression of immediate early gene. PC3 gene is immediate early gene related to liver regeneration.

Animals↗

[Preparation of thin hydroxyapatite layers on cp titanium through anodic oxidation followed with hydrothermal treatment].

To study the method of anodic oxidation followed by hydrothermal treatment for cp titanium and to know bone response to thin hydroxyapatite layers in vivo, commercially pure titanium plates were anodized at 200 V-400 V with direct electric current density no more than 50 mA/cm2 for 15 minutes in the electrolytic trough. beta-glycerophosphate sodium(0.03-0.04 M) and calcium acetate(0.2-0.3 M) were used as electrolytes. Then, titanium plates were hydrothermal treated in the autoclave for 2 hours at 280 degrees C-300 degrees C. Polishing and grit-blasting surface was used as control to learn bone response to thin layers. Twelve rabbits were evenly divided into 3 groups, each group was implanted with 12 implants into the rabbits femoral bone. After 4, 8 and 16 weeks, implants were taken out and collected respectively and were made grinding slices. The bone-implant interface was observed with light microscope. And the bone-implant interface of polishing and layered implants after 8 weeks implantation was observed with scanning electron microscope. The element contents at the interface of polishing and layered implants before and after 8 weeks implantation were detected with EDAX. Results showed that there was hydroxyapatite(HA) precipitated on the titanium surfaceamellae bone in 8 weeks for thin HA coatings, and no HA debris were found at the interfacial zone. In addition, Ca and P content on the hydrothermal treated implant surface increased much more after implantation than that of polished implants. It was concluded that anodic oxidation followed by hydrothermal treatment could precipitate thin hydroxyapatie layer on the surface of cp titanium, which could improve early formation of woven bone and accelerate woven bone transferring to lamellae bone at the implanted site.

Animals↗

Fast Algorithm for X-ray Cone-beam Microtomography.

Cone-beam X-ray microtomography attracts increasing attention due to its applications in biomedical sciences, material engineering, and industrial nondestructive evaluation. Rapid volumetric image reconstruction is highly desirable in all these areas for prompt visualization and analysis of complex structures of interest. In this article, we reformulate a generalized Feldkamp cone-beam image reconstruction algorithm, utilize curved voxels and mapping tables, improve the reconstruction efficiency by an order of magnitude relative to a direct implementation of the standard algorithm, and demonstrate the feasibility with numerical simulation and experiments using a prototype cone-beam X-ray microtomographic system. Our fast algorithm reconstructs a 256-voxel cube from 100 projections within 2 min on an Intel Pentium II(R) 233 MHz personal computer, produces satisfactory image quality, and can be further accelerated using special hardware and/or parallel processing techniques.

Journal Article↗

Novel Helicobacter pylori alpha1,2-fucosyltransferase, a key enzyme in the synthesis of Lewis antigens.

Helicobacter pylori lipopolysaccharides (LPS) contain complex carbohydrates known as Lewis antigens which may contribute to the pathogenesis and adaptation of the bacterium. Involved in the biosynthesis of Lewis antigens is an alpha1,2-fucosyltransferase (FucT) that adds fucose to the terminal betaGal unit of the O-chain of LPS. Recently, the H. pylori (Hp) alpha1,2-FucT-encoding gene (fucT2) was cloned and analysed in detail. However, due to the low level of expression and instability of the protein, its enzymic activity was not demonstrated. In this study, the Hp fucT2 gene was successfully overexpressed in Escherichia coli. Sufficient amounts of the protein were obtained which revealed alpha1,2-fucosyltransferase activity to be associated with the protein. A series of substrates were chosen to examine the acceptor specificity of Hp alpha1,2-FucT, and the enzyme reaction products were identified by capillary electrophoresis. In contrast to the normal mammalian alpha,2-FucT (H or Se enzyme), Hp alpha1,2-FucT prefers to use Lewis X [betaGal1-4(alphaFuc1-3)betaGlcNAc] rather than LacNAc [betaGal1-4betaGIcNAc] as a substrate, suggesting that H. pylori uses a novel pathway (via Lewis X) to synthesize Lewis Y. Hp alpha1,2-FucT also acts on type 1 acceptor [betaGal1-3betaGlcNAc] and Lewis a [betaGal1-3(alphaFuc1-4)betaGIcNAc], which provides H. pylori with the potential to synthesize H type 1 and Lewis b epitopes. The ability to transfer fucose to a monofucosylated substrate (Lewis X or Lewis a) makes Hp alpha1,2-FucT distinct from normal mammalian alpha1,2-FucT.

Antigens, Bacterial↗