PubMed Health⌕ Search

Biomedical subjects

Georg Rainer

Publications and source records attributed to Georg Rainer.

At least 19 recordsLinked to original sources

Long-term effect of sharp optic edges of a polymethyl methacrylate intraocular lens on posterior capsule opacification: a randomized trial.

PURPOSE: To compare the posterior capsule opacification (PCO) inhibiting effect of a 3-piece polymethyl methacrylate (PMMA) intraocular lens (IOL) with a sharp optic edge design with that of the round-edged version of the same IOL during a 5-year period. DESIGN: Randomized patient- and examiner-masked clinical trial with intraindividual comparison. PARTICIPANTS: Thirty-two patients with bilateral age-related cataract (64 eyes). METHODS: Each study patient had phacoemulsification cataract surgery in both eyes and received a sharp optic edge PMMA IOL in one eye and a round optic edge PMMA IOL in the fellow eye (both by Dr Schmidt in Germany). Follow-up examinations were at 1 week, 1 month, 1 year, 3 years, and 5 years. Digital retroillumination images were taken from each eye. The amount of posterior capsule opacification was assessed objectively by means of automated image analysis software (Automated Quantification of After-Cataract) at 1 year, 3 years, and 5 years after surgery. MAIN OUTCOME MEASURE: Posterior capsule opacification score: 0-10. RESULTS: The sharp optic edge IOL showed significantly less regeneratory and fibrotic PCO at 1 year, 3 years, and 5 years after surgery. The mean AQUA PCO score was 5.12 for the round-edge and 2.49 for the sharp-edge IOL (scale, 0-10; P<0.001) at 5 years. The mean difference among patients for the PCO score in the eye implanted with the sharp optic edge versus the score in the eye with the round optic edge was 2.83 at 5 years (95% confidence interval, 1.66-4.00). Due to the large number of neodymium:yttrium-aluminum-garnet laser capsulotomies that were performed (12 in the round-edge group and 4 in the sharp-edge group), there was no significant difference in visual acuity between both groups at any time point. CONCLUSIONS: Compared with the round-edge version, the sharp optic edge design of a 3-piece PMMA IOL led to significantly less PCO at 1 year, 3 years, and 5 years after surgery. However, the sharp optic edge did not lead to complete PCO prevention during this follow-up period. This finding has implications for the design of PMMA IOLs used for cataract surgery, especially in the developing world.

Aged↗

Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics: randomized clinical trial.

PURPOSE: Comparison of the intensity of posterior capsule opacification (PCO) between a silicone intraocular lens (IOL) and a hydrophobic acrylic IOL, both of them 3-piece and open-loop and having truncated optics with sharp edges. DESIGN: Randomized, controlled, patient- and examiner-masked trial with intrapatient comparison. PARTICIPANTS AND CONTROLS: One hundred six eyes of 53 patients with age-related bilateral cataract. METHODS: Each patient had cataract surgery in both eyes and received a silicone IOL in one eye and a hydrophobic acrylic IOL in the fellow eye. Follow-up examinations were at 1 and 3 years after surgery. The patients were examined at the slit lamp, visual acuity (VA) was assessed, and standardized high-resolution digital retroillumination images of the posterior capsule were taken. The amount of PCO was assessed subjectively at the slit lamp and objectively using automated image analysis software. Data of 56 eyes of 28 patients, who were examined at each follow-up, were analyzed. MAIN OUTCOME MEASURE: Posterior capsule opacification intensity at 3 years as measured with automated image analysis. RESULTS: At 1 and 3 years after surgery, PCO did not differ between the silicone (1.6 and 1.9 [image analysis scores, 0-10 scale], respectively) and acrylic IOLs (1.7 and 2.2) (P > 0.24). Furthermore, there was no significant difference in best-corrected VA, rhexis/IOL overlap, capsular folds, and amount of anterior capsule opacification during the follow-up period. In each group, one neodymium:yttrium-aluminum-garnet (YAG) laser capsulotomy was performed during the entire study duration. CONCLUSION: Silicone and hydrophobic acrylic are similarly effective in inducing the PCO-inhibiting effect of a rectangular, sharp optic edge. Three years after surgery, the PCO intensity and the YAG rate were low with both IOL models.

Acrylic Resins↗

Effects of moderate changes in intraocular pressure on ocular hemodynamics in patients with primary open-angle glaucoma and healthy controls.

PURPOSE: There is some indirect evidence for altered autoregulation in patients with glaucoma, but only a few studies have measured ocular blood flow directly during changes in ocular perfusion pressure. The present study was designed to compare pulsatile choroidal blood flow and optic nerve head (ONH) blood flow during moderate increases in intraocular pressure (IOP) in patients with primary open-angle glaucoma (POAG) and normal controls. DESIGN: Two nonrandomized studies comparing blood flow responses in glaucoma patients and controls in an open design. PARTICIPANTS AND CONTROLS: Sixteen patients with POAG glaucoma and 16 healthy gender-matched and age-matched controls were included in the choroidal blood flow experiments. The ONH blood flow experiment was performed in 14 POAG patients and 14 healthy gender-matched and age-matched controls. METHODS: In the first study, pulsatile choroidal blood flow was assessed by laser interferometric measurement of fundus pulsation amplitude (FPA). In the second study, ONH blood flow was measured using laser Doppler flowmetry. In both cohorts, the IOP was increased stepwise by 10 and 20 mmHg using a suction cup. MAIN OUTCOME MEASURES: Fundus pulsation amplitude and ONH blood flow. RESULTS: The baseline values of FPA and ONH blood flow were lower in glaucoma patients as compared with age-matched and gender-matched healthy controls. In patients with POAG, FPA decreased by -4.5+/-5.8% and -11.3+/-4.9% during elevation of IOP of 10 and 20 mmHg, respectively. These results were not different from the results in healthy controls, where FPA decreased by -5.1+/-3.4% and -12.2+/-4.9% at the 2 pressure levels (P = 0.23 between groups). Optic nerve head blood flow showed no changes during the increase of IOP of 10 and 20 mmHg in either of the 2 groups (glaucoma patients, +2.1+/-14.7% and -0.8+/-15.2%; healthy controls, +4.3+/-12.0% and +0.2+/-14.2%; P = 0.83 between groups). CONCLUSIONS: The present study does not provide evidence for altered autoregulation in patients with POAG during a moderate increase in IOP. However, these results do not necessarily contradict the concept of vascular dysregulation in glaucoma.

Aged↗

Natural course of intraocular pressure after cataract surgery with sodium chondroitin sulfate 4%-sodium hyaluronate 3% (Viscoat).

PURPOSE: To investigate the natural course of intraocular pressure (IOP) and its peak after small-incision cataract surgery with chondroitin sulfate 4%-sodium hyaluronate 3% (Viscoat, Alcon Laboratories, Inc., Fort Worth, TX). DESIGN: Observational case series. PARTICIPANTS: This prospective study comprised 40 eyes of 40 consecutive cataract patients scheduled for small-incision cataract surgery. METHODS: Cataract surgery was performed with sodium chondroitin sulfate 4%-sodium hyaluronate 3% as the ophthalmic viscosurgical device, which was removed as completely as possible from the eye at the end of surgery. The IOP was measured preoperatively and 30 minutes; 1, 2, 3, 4, 6, 8, and 20 to 24 hours; and 1 week postoperatively. MAIN OUTCOME MEASURES: Postoperative IOP increase. RESULTS: The mean IOP increased significantly at all observation times during the first 20 to 24 hours, with a peak increase of 13.4+/-9.4 mmHg after 1 hour (P<0.05). In all, 28 eyes (70%) had an IOP spike to 30 mmHg or higher. Sixty-eight percent of these spikes occurred at 30 minutes as well as at 1 hour and 2 hours postoperatively. At 20 to 24 hours, no eye had an IOP spike to 30 mmHg or higher. CONCLUSIONS: Significant IOP increases were found during the first 24 hours, peaking at 1 hour after surgery. With a single postoperative IOP measurement, between 30 minutes and 2 hours after surgery, two thirds of these IOP spikes could be detected. To detect all IOP spikes, a second measurement between 4 and 6 hours after surgery would be necessary.

Aged↗

Influence of optic edge design and anterior capsule polishing on posterior capsule fibrosis.

PURPOSE: To evaluate the role of posterior optic edge design and the effect of anterior capsule polishing on peripheral fibrotic posterior capsule opacification (PCO). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This randomized prospective study comprised 144 eyes of 72 patients with bilateral age-related cataract. Each patient had standardized cataract surgery in both eyes by the same surgeon. Group 1 (46 patients) received a round-edged hydrophobic acrylic IOL (AMO Sensar AR40) in 1 eye and a sharp-edged hydrophobic acrylic IOL (AMO Sensar OptiEdge AR40e) in the other eye. Group 2 (26 patients) received a silicone IOL (Pharmacia CeeOn 911A) with a truncated optic in both eyes. In this group, the anterior capsule was extensively polished in 1 eye and was left unpolished in the other eye. Digital slitlamp photographs were taken 1 year postoperatively using a standardized photographic technique for fibrotic PCO. The intensity of PCO was subjectively graded (score 0 to 4) by 2 masked examiners. RESULTS: Subjective PCO scores correlated well between the 2 examiners (r = 0.88). In Group 1, the mean PCO score was 0.26 for the OptiEdge AR40e IOL and 0.90 for the AR40 IOL (P<.01). In Group 2, the mean PCO score was 0.24 in eyes with a polished capsule and 0.17 in eyes in which the capsule was not polished (P =.31). CONCLUSIONS: The sharp-edged OptiEdge AR40e IOL led to significantly less peripheral fibrotic PCO 1 year postoperatively than the round-edged AR40 IOL. In eyes with the sharp-edged silicone 911A IOL, anterior capsule polishing caused no significant difference in fibrotic PCO.

Acrylic Resins↗

Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.

PURPOSE: To examine the influence of intraocular lens (IOL) optic edge design and optic material on fibrosis of the anterior and peripheral posterior capsules and on capsulorhexis contraction. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This randomized controlled patient- and examiner-masked study comprised 210 eyes of 105 patients with bilateral age-related cataract. In Group 1 (n = 53), the Sensar OptiEdge AR40e hydrophobic acrylic IOL with a sharp posterior optic edge was compared with the AR40 acrylic IOL with a round edge. In Group 2 (n = 52), the ClariFlex OptiEdge silicone IOL with a sharp posterior optic edge was compared with the PhacoFlex SI-40 silicone IOL with a round edge All IOLs were manufactured by Advanced Medical Optics, Inc. Standardized digital slitlamp images of anterior capsule opacification (ACO) and fibrotic posterior capsule opacification (PCO) were taken 1 year postoperatively, and digital retroillumination images were taken at 1 week and 1 year. The intensity of fibrotic PCO was graded subjectively (score 0 to 4), ACO was graded objectively (score 0% to 100%), and the capsulorhexis area (mm(2)) was determined objectively. RESULTS: One year after surgery, the mean ACO score was 32% in eyes with the sharp-edged acrylic IOL and 29% in eyes with the round-edged acrylic IOL (P<.05). In the silicone group, the mean was 31% and 26%, respectively (P<.05). The mean fibrotic PCO score was lower in eyes with a sharp-edged acrylic IOL than in eyes with a round-edged acrylic IOL (0.26 and 0.93, respectively; P<.05) and in eyes with a sharp-edged silicone IOL than in eyes with a round-edged silicone IOL (0.24 and 0.82, respectively; P<.001). At 1 year, the mean capsulorhexis area was statistically significantly smaller in eyes with a sharp-edged silicone IOL than in eyes with a round-edged silicone IOL (P<.05). CONCLUSIONS: Acrylic and silicone IOLs with the sharp OptiEdge design led to significantly less fibrotic PCO but more ACO than round-edged acrylic and silicone IOLs. The sharp-edged silicone IOL caused significantly more capsulorhexis contraction than the round-edged silicone IOL and both acrylic IOLs.

Acrylic Resins↗

Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results.

PURPOSE: To evaluate the long-term effect of anterior capsule polishing on anterior capsule opacification (ACO) and peripheral fibrotic posterior capsule opacification (PCO). SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This randomized double-blind study comprised 104 eyes of 52 patients with bilateral age-related cataract. All patients received round-edged intraocular lenses (IOLs); 26 received an SI-40 IOL (Advanced Medical Optics Inc.) in both eyes, and 26 received a Silens6 IOL (Domilens) in both eyes. Both IOLs consist of different silicone material and have different haptic angulation. The SI-40 IOL has 13.0 mm open-loop poly(methyl methacrylate) (PMMA) haptics angulated by 10 degrees. The Silens6 IOL has 12.5 mm open-loop PMMA haptics with no angulation. In 1 eye, the anterior capsule was extensively polished. The anterior capsule was left unpolished in the contralateral eye, which acted as a control. Digital slitlamp photographs of the ACO and fibrotic PCO were taken with a standardized technique for 3 years postoperatively. The intensity of ACO was measured objectively (score 0% to 100%) using Adobe Photoshop software. Fibrotic PCO was graded subjectively (score 0 to 4). RESULTS: The mean ACO was 17% in the polished eyes and 26% in the control eyes (P = .0001). The mean fibrotic PCO score was 0.5 and 1.0, respectively (P = .0007). The mean ACO was 15% in the polished SI-40 eyes and 26% in the control SI-40 eyes (P = .01). It was 19% in the polished Silens6 eyes and 26% in the control Silens6 eyes (P = .003). The mean fibrotic PCO score was 0.4 in the polished SI-40 eyes and 1.1 in the control SI-40 eyes (P = .0006). It was 0.6 in the polished Silens6 eyes and 0.9 in the control Silens6 eyes (P = .08). CONCLUSIONS: Three years after surgery, eyes in which the anterior capsule was extensively polished had less ACO and fibrotic PCO with both round-edged silicone IOLs. In eyes with Silens6 IOLs, however, the reduction in fibrotic PCO was not significant.

Aged↗

Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan system.

OBJECTIVE: To compare the reliability of central corneal thickness measurements (CCT) obtained with partial coherence interferometry (PCI), ultrasound pachymetry, and the Orbscan system. DESIGN: Cross-sectional study. PARTICIPANTS: Twenty healthy subjects with CCT measurements in both eyes. METHODS: The CCT measurements were obtained with PCI, ultrasound pachymetry, and the Orbscan system. In each eye, 2 investigators performed 5 repeated measurements with each pachymetric device. Intraclass correlation coefficients (kappa) were calculated and mean CCT measurements were compared. MAIN OUTCOME MEASURES: The CCT measurements obtained with ultrasound pachymetry, the Orbscan system (Orbtek Inc., Salt Lake City, UT), and PCI. RESULTS: Mean CCT values measured with ultrasound pachymetry were significantly thicker than those measured with PCI (21.5 microm; P<0.001) or the Orbscan system (19.8 microm; P<0.001). The correlation coefficients for the intraobserver variability were 0.999 for PCI measurements, 0.983 for ultrasound pachymetry measurements, and 0.988 for Orbscan system measurements. The correlation coefficients for the interobserver variability were 0.998 for PCI measurements, 0.980 for ultrasound pachymetry measurements, and 0.988 for Orbscan system measurements. There was a slightly better consistency between ultrasound pachymetry and PCI (kappa = 0.96) than between the Orbscan system and PCI (kappa = 0.92) and between ultrasound pachymetry and the Orbscan system (kappa = 0.89). CONCLUSIONS: Partial coherence interferometry was the method with the least intraobserver or interobserver variability. Mean CCT as measured with ultrasound pachymetry was approximately 20 microm thicker than with the Orbscan system and PCI. However, corneal thickness measurements with ultrasound pachymetry and PCI were slightly more consistent than those of the Orbscan system and PCI. This slightly better consistency, however, may be important, especially in corneal refractive surgery.

Adult↗

Effect of optic edge design and haptic angulation on postoperative intraocular lens position change.

PURPOSE: To assess the effect of optic edge design and optic-haptic angulation of open-loop intraocular lenses (IOLs) on postoperative axial movement and the final position of the optic by measuring the anterior chamber depth (ACD) during the first postoperative year using partial coherence interferometry (PCI). SETTING: Department of Ophthalmology, Vienna General Hospital, Institute of Medical Physics, University of Vienna, Vienna, Austria. METHODS: In study 1, a 3-piece silicone IOL with nonangulated modified C-loop haptics (MicroSil, Dr. Schmidt) was implanted in 78 eyes of 39 patients; patients were randomized to receive a round-edged optic IOL in 1 eye and a sharp-edged optic IOL in the other eye. The ACD was measured by PCI 1 day, 1 week, 3 months, and 1 year after surgery. In study 2, a foldable, 3-piece acrylic IOL with modified 10-degree angulated J-loop haptics (AcrySof MA60BM, Alcon) was implanted in 32 eyes of 32 patients. The ACD was measured by PCI 1 day, 1 week, and 3 months after surgery. RESULTS: In eyes with a nonangulated silicone IOL, there was a significant postoperative change in ACD with both sharp-edged and round-edged designs (P<.01). There was forward movement of both IOL designs in the first week, with no significant difference between the 2 models. From 1 week to 3 months, there was backward movement of IOLs of both designs, with the sharp-edged IOL moving a significantly greater amount (P<.001). From 3 months to 1 year, IOLs with both optic edge designs moved slightly backward. Sixty-six percent of angulated IOLs showed continuous but variable forward movement and 34%, backward movement. CONCLUSIONS: Optic edge design influenced postoperative axial optic movement and thus had an impact on the development of postoperative refraction (refractive shift, deviation from target refraction). The influence of optic-haptic angulation proved to be significantly greater and more variable than edge design.

Acrylic Resins↗

Self-tonometry with the Ocuton S: evaluation of accuracy in glaucoma patients.

BACKGROUND: To compare two methods of measuring intraocular pressure (IOP) and to evaluate whether repeated measurements taken with the Ocuton S applanation self-tonometer can improve reliability. METHODS: Ocuton S and Goldmann applanation tonometry (GAT), and corneal thickness measurements taken with the Orbscan topography system, were successfully performed in 64 of 68 glaucoma patients. RESULTS: The median IOPs were 15.5 mmHg using GAT, and 16 mmHg using the first self-taken Ocuton S measurement (n = 64). The differences between the median of the GAT measurements and the first Ocuton S measurement, and the medians of the three and six separate Ocuton S measurements were within 3 mmHg in 52%, 59% and 67% of cases, respectively. The mean corneal thickness of all evaluated eyes was 545.3 microm. There was no effect of corneal thickness on the accuracy of either of the two devices (p > 0.05). CONCLUSION: Repeated measurements can improve the reliability of the Ocuton S. However, even with repeated measurements only every second patient succeeds in obtaining reliable measurements.

Adult↗

Ocular blood flow and systemic blood pressure in patients with primary open-angle glaucoma and ocular hypertension.

PURPOSE: There is evidence that altered optic nerve head (ONH) blood flow may play a role in the development and progression of glaucoma. In the present study, the baseline characteristics were examined in a study population participating in a clinical trial in which the ocular hemodynamic effects of timolol and dorzolamide were compared. METHODS: One hundred forty patients with primary open-angle glaucoma (POAG) or ocular hypertension (OHT) were included in this trial and their baseline parameters compared with those of a group of 102 age-matched control subjects. Scanning laser Doppler flowmetry was used to measure blood flow in the temporal neuroretinal rim and the cup of the ONH. Pulsatile choroidal blood flow was assessed by laser interferometric measurement of fundus pulsation amplitude. In addition, hemodynamic parameters and mean arterial pressure were calculated in both groups. RESULTS: All ocular hemodynamic parameters were significantly lower in the POAG/OHT group compared with the healthy control group (P < 0.001 each). In addition, a significant positive correlation between laser Doppler flowmetry readings and mean arterial pressure was observed in patients with glaucoma but not in healthy control subjects. Likewise, the correlation coefficient between fundus pulsation amplitude and mean arterial pressure was higher in patients with glaucoma than in healthy control subjects. CONCLUSIONS: The present study indicates reduced ONH and choroidal blood flow and an abnormal association between blood pressure and ocular perfusion in patients with primary open-angle glaucoma or ocular hypertension, independent of topical antiglaucoma medication. Hence, vascular dysregulation appears to be an early manifestation in glaucoma that is not caused by pharmacologic intervention.

Antihypertensive Agents↗

Comparison of 4 methods for quantifying posterior capsule opacification.

PURPOSE: To compare the results of posterior capsule opacification (PCO) quantification and the repeatability of a fully automated analysis system (Automated Quantification of After-Cataract [AQUA]) with that of 2 other quantification methods and subjective grading of PCO. A test set of digital retroillumination images of 100 eyes with PCO of varying degrees was used. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: One hundred digital retroillumination images of eyes (100 patients) with PCO were selected to attain an even distribution from mild to severe cases. The images were evaluated by 4 methods: subjective grading by 4 experienced and 4 inexperienced examiners, the subjective Evaluation of Posterior Capsular Opacification (EPCO) system, posterior capsule opacification (POCO) software, and the AQUA system. Ten images were presented twice to assess the reproducibility of the analysis systems. RESULTS: Subjective grading correlated best with the subjective EPCO system and the objective AQUA system (r = 0.94 and r = 0.93, respectively). The POCO system showed very early saturation and therefore a much weaker correlation (r = 0.73). The POCO scores reached the maximum of 100% in several minimal to mild PCO cases. The reproducibility of the AQUA software was perfect and that of the other analysis systems, comparably satisfactory. CONCLUSION: The objective AQUA score correlated well with subjective methods including the EPCO system. The POCO system, which assesses PCO area, did not adequately describe PCO intensity and includes a subjective step in the analysis process. The AQUA system could become an important tool for randomized masked trials of PCO inhibition.

Cataract↗

Intraocular lens movement caused by ciliary muscle contraction.

PURPOSE: To investigate intraocular lens (IOL) movement, measured as a change in anterior chamber depth (ACD) caused by pilocarpine-induced ciliary muscle contraction. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: In this prospective study, the ACD was measured using high-precision, high-resolution, dual-beam partial coherence interferometry in 62 pseudophakic eyes of 55 patients under pilocarpine- and cyclopentolate-induced ciliary muscle contraction and relaxation. The following were studied: 2 models of a ring-haptic IOL (designed to accommodate), a plate-haptic IOL, and 3 types of 3-piece IOLs. Measurements were performed 3 months after surgery. RESULTS: The ring-haptic IOLs and plate-haptic IOL showed a forward movement (ring haptic 43A, -116 microm; ring haptic 43E, -222 microm; plate haptic -162 microm). The 3-piece IOLs showed no change in ACD except in 1 IOL type in which there was backward movement (156 microm). CONCLUSIONS: Pilocarpine-induced ciliary muscle contraction caused forward movement of ring- and plate-haptic IOLs that resulted in an estimated accommodative amplitude of less than 0.50 diopter in most cases. The accommodating ring-haptic IOLs did not perform better than the conventional plate-haptic IOL.

Accommodation, Ocular↗

After-cataract in adults with primary posterior capsulorhexis: comparison of hydrogel and silicone intraocular lenses with round edges after 2 years.

PURPOSE: To evaluate the potential of primary posterior continuous curvilinear capsulorhexis (PCCC) to prevent after-cataract 2 years after surgery and perform a bilateral comparison of 2 intraocular lens (IOL) materials, silicone and hydrogel. SETTING: Department of Ophthalmology, University of Vienna, Medical School, Vienna, Austria. METHODS: In this randomized patient- and examiner-masked study, 37 patients (74 eyes) with age-related cataract had bilateral small-incision cataract surgery with PCCC. Randomly, 1 eye received a hydrogel IOL and the contralateral eye, a silicone IOL. Both IOLs had open-loop haptics and a round-edged optic. Standardized digital retroillumination photographs were taken 1 day and 1, 6, 12, and 24 months after surgery to evaluate development of after-cataract on the anterior and posterior capsules by subjective grading. Opacification of the PCCC area was also objectively evaluated using new software. RESULTS: Twenty-nine patients (58 eyes) completed the 2-year follow-up. Partial closure with ongrowth at the edge of the PCCC was found in 55% in the hydrogel group and 28% in the silicone group. Total closure of the PCCC was observed in 3 eyes, 2 in the hydrogel group and 1 in the silicone group. CONCLUSION: Ongrowth onto the PCCC area was dependent on IOL material. Because of less ongrowth and more fibrotic after-cataract with silicone IOLs, the efficacy of the PCCC was higher in this group.

Aged↗

Effect of a fixed dorzolamide-timolol combination on intraocular pressure after small-incision cataract surgery with Viscoat.

PURPOSE: To evaluate the effect of a fixed dorzolamide-timolol combination (Cosopt) on intraocular pressure (IOP) after small-incision cataract surgery with sodium chondroitin sulfate 4%-sodium hyaluronate 3% (Viscoat). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized study comprised 76 eyes of 38 patients scheduled for small-incision cataract surgery in both eyes. Patients were randomized to receive 1 drop of the fixed dorzolamide-timolol combination in 1 eye or no treatment (control) immediately after cataract surgery. The fellow eye received the other assigned treatment. Cataract surgery was performed with Viscoat in an identical fashion in both eyes. The IOP was measured preoperatively and 6 hours, 20 to 24 hours, and 1 week postoperatively. RESULTS: Six hours after surgery, the mean increase in IOP was significantly lower in the dorzolamide-timolol group than in the control group (4.3 mm Hg +/- 5.6 [SD] versus 8.4 +/- 6.1 mm Hg; P =.003). Two eyes in the dorzolamide-timolol group and 9 in the control group had IOP spikes of 30 mm Hg or higher (P =.022). Twenty to 24 hours after surgery, the mean IOP change was -2.6 +/- 3.3 mm Hg in the dorzolamide-timolol group and 1.5 +/- 3.2 mm Hg in the control group (P<.001). CONCLUSIONS: The fixed dorzolamide-timolol combination was effective in reducing IOP 6 hours and 20 to 24 hours after cataract surgery. However, it did not prevent Viscoat-induced IOP spikes of 30 mm Hg or higher.

Aged↗

Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery.

PURPOSE: To compare measurements performed with the IOLMaster (Carl Zeiss, Meditec AG) with those obtained by applanation ultrasound (US) and manual keratometry and to evaluate the effect of operator experience on US biometry. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: The axial length (696 eyes) and anterior chamber depth (ACD) (462 eyes) were measured in 377 patients with cataract using the IOLMaster and applanation US. To assess the effect of operator experience on the biometric results, the operators were divided into 2 groups: experienced and less experienced in performing US biometry. The difference in measurements between the methods and the variability of the difference were compared between the 2 groups. RESULTS: Applanation US measured axial length and ACD shorter than the IOLMaster; the mean numerical difference was 0.13 mm and 0.19 mm, respectively (P<.01). For axial length, the absolute difference was smaller with experienced operators than with less experienced operators (0.15 mm versus 0.22 mm) (P<.01). For ACD, experienced operators obtained a smaller difference between measurement techniques (0.21 mm versus 0.29 mm; P<.05). CONCLUSIONS: Experienced US operators had less difference and lower variability in the difference between applanation US and IOLMaster readings for axial length and ACD measurements. The noncontact optical method, which is essentially operator independent, gave significantly more reliable biometry before cataract surgery, especially in the case of less experienced operators.

Adult↗

Influence of intraocular lens material on regeneratory posterior capsule opacification after neodymium:YAG laser capsulotomy.

PURPOSE: To evaluate the influence of a neodymium:YAG (Nd:YAG) laser capsulotomy on the morphology and development of regeneratory opacification of the remaining surrounding posterior capsule. SETTING: Department of Ophthalmology, Medical School, University of Vienna, Vienna, Austria. METHODS: Standardized digital retroillumination photographs were taken immediately before and after Nd:YAG laser capsulotomy and at 1 week, 6 months, and 1 to 3 years in 38 eyes of consecutive patients. Changes in regeneratory posterior capsule opacification (PCO) and opacification around the capsulotomy opening were evaluated. The influence of the type of intraocular lens (IOL) material and design (acrylic, n = 8; hydrogel, n = 8; silicone open loop, n = 11; silicone plate haptic, n = 6; poly(methyl methacrylate) [PMMA], n = 5) was assessed. The state of the anterior vitreous surface was examined at the slitlamp in all eyes. RESULTS: In 8 of 17 eyes with a silicone IOL, reduced regeneratory PCO was observed. Massive pearl formation on the margin of the Nd:YAG capsulotomy was typical with silicone IOLs (8 eyes) but also occurred with PMMA IOLs. Eyes with acrylic IOLs had no change in regeneratory PCO after the capsulotomy. Three of 8 eyes with hydrogel IOLs had complete closure of the posterior capsulotomy opening. CONCLUSIONS: Neodymium:YAG laser capsulotomy induced changes in the development and morphology of regeneratory PCO. Silicone and PMMA IOLs led to significant pearl formation on the capsulotomy margin, often combined with a reduction of peripheral regeneratory PCO (silicone). Hydrogel IOLs led to a higher incidence of reclosure of the Nd:YAG capsulotomy opening.

Acrylic Resins↗

Correlation between the early morphological appearance of filtering blebs and outcome of trabeculectomy with mitomycin C.

PURPOSE: To correlate the morphologic appearance of filtering blebs in the early postoperative period with the outcome of trabeculectomy with mitomycin C (MMC) during the first postoperative year. PATIENTS AND METHODS: In a prospective study, the morphologic appearance of filtering blebs after primary trabeculectomy with adjunctive MMC (0.1 mg/ml for 5 minutes intra-operatively) was classified; 49 eyes of 49 patients were examined preoperatively, 1 and 3 days, 1 and 2 weeks, 1, 3, 6, and 12 months postoperatively. Status of filtering bleb, intraocular pressure (IOP), and number of medications were recorded. RESULTS: One year after surgery all patients had IOP < or = 21; 6 patients received antiglaucoma medication. One eye required needling of the filtering bleb because of encapsulation. During the first postoperative year, eyes with conjunctival subepithelial micro cysts, observed in the first and the second postoperative week, had significantly lower mean IOP, than eyes without (11.1 mm Hg vs. 13.9 mm Hg; p:0.0043, ANOVA). Eyes with corkscrew vessels, observed in the first and the second postoperative week, had significantly higher mean IOP, than eyes without during the first postoperative year (13.4 mm Hg vs. 11.7 mm Hg; p:0.0141, ANOVA). CONCLUSION: Classification of filtering blebs after trabeculectomy with MMC may help to disclose patients with an increased failure risk.

Aged↗