Performance of a novel collimator for high-sensitivity brain SPECT.

We assessed improvements in performance in detection and estimation tasks due to a novel brain single photon computed tomography collimator. Data were acquired on the CeraSPECT scanner using both new and standard collimators. The new variable focusing collimator SensOgrade samples the projections unequally, with central regions more heavily represented, to compensate for attenuation of counts from central brain structures. Furthermore, it utilizes more of the cylindrical crystal surface. Two phantom studies were performed. The first phantom was a 21-cm-diameter cylindrical background containing nine spheres ranging from 0.5 to 5 cm3 in volume. 99mTc sphere to background activity ratio was 10:1. Twenty-nine 10-min datasets were acquired with each collimator. The second phantom was the Radiology Support Devices (Long Beach, CA) striatal phantom with striatal-background ratios of 10:1 on the left and 5:1 on the right. Twenty-nine 4-min datasets were acquired with each collimator. Perfusion imaging using 99mTc-HMPAO was also performed in three healthy volunteers using both collimators under identical simulations. Projections were reconstructed by filtered backprojection with an unwindowed ramp filter. The nonprewhitening matched filter signal-to-noise ratio (NPW-SNR) was computed as a surrogate for human performance in detecting spherical lesions. Sphere activity concentration, radius, and location coordinates were simultaneously estimated by fitting images to an assumed model using an iterative nonlinear algorithm. Resolution recovery was implicit in the estimation procedure, as the point spread function was incorporated into the model. NPW-SNR for sphere detection was 1.5 to 2 times greater with the new collimator; for the striatal phantom the improvement in SNR was 54%. The SNR for estimating sphere activity concentration improved by 46 to 89% for spheres located more than 5 cm from the phantom center. Images acquired with the standard collimator were too noisy in the central regions to allow estimation of sphere activity. In 99mTc-HMPAO human studies, SNR was improved by 21 to 41% in the cortex, 66% in the basal ganglia, and 74% in the thalamus. The new collimator leads to substantially improved detection and estimation performance throughout the brain. The higher sensitivity will be particularly important for dynamic imaging.

Brain↗

Generalized five-dimensional dynamic and spectral factor analysis.

We have generalized the spectral factor analysis and the factor analysis of dynamic sequences (FADS) in SPECT imaging to a five-dimensional general factor analysis model (5D-GFA), where the five dimensions are the three spatial dimensions, photon energy, and time. The generalized model yields a significant advantage in terms of the ratio of the number of equations to that of unknowns in the factor analysis problem in dynamic SPECT studies. We solved the 5D model using a least-squares approach. In addition to the traditional non-negativity constraints, we constrained the solution using a priori knowledge of both time and energy, assuming that primary factors (spectra) are Gaussian-shaped with full-width at half-maximum equal to gamma camera energy resolution. 5D-GFA was validated in a simultaneous pre-/post-synaptic dual isotope dynamic phantom study where 99mTc and 123I activities were used to model early Parkinson disease studies. 5D-GFA was also applied to simultaneous perfusion/dopamine transporter (DAT) dynamic SPECT in rhesus monkeys. In the striatal phantom, 5D-GFA yielded significantly more accurate and precise estimates of both primary 99mTc (bias=6.4 % +/- 4.3 %) and 1231 (-1.7% +/- 6.9%) time activity curves (TAC) compared to conventional FADS (biases = 15.5% +/- 10.6% in 99mTc and 8.3% +/- 12.7% in 123I, p < 0.05). Our technique was also validated in two primate dynamic dual isotope perfusion/DAT transporter studies. Biases of 99mTc-HMPAO and 123I-DAT activity estimates with respect to estimates obtained in the presence of only one radionuclide (sequential imaging) were significantly lower with 5D-GFA (9.4% +/- 4.3% for 99mTc-HMPAO and 8.7% +/-4.1% for 123I-DAT) compared to biases greater than 15% for volumes of interest (VOI) over the reconstructed volumes (p < 0.05). 5D-GFA is a novel and promising approach in dynamic SPECT imaging that can also be used in other modalities. It allows accurate and precise dynamic analysis while compensating for Compton scatter and cross-talk.

Algorithms↗

Quantitative simultaneous (99m)Tc-ECD/123I-FP-CIT SPECT in Parkinson's disease and multiple system atrophy.

PURPOSE: The purpose of this study was to investigate the feasibility and utility of dual-isotope SPECT for differential diagnosis of idiopathic Parkinson's disease (IPD) and multiple system atrophy (MSA). METHODS: Simultaneous (99m)Tc-ECD/123I-FP-CIT studies were performed in nine normal controls, five IPD patients, and five MSA patients. Projections were corrected for scatter, cross-talk, and high-energy penetration, and iteratively reconstructed while correcting for patient-specific attenuation and variable collimator response. Perfusion and dopamine transporter (DAT) function were assessed using voxel-based statistical parametric mapping (SPM2) and volume of interest quantitation. DAT binding potential (BP) and asymmetry index (AI) were estimated in the putamen and caudate nucleus. RESULTS: Striatal BP was lower in IPD (55%) and MSA (23%) compared to normal controls (p<0.01) , and in IPD compared to MSA (p<0.05). AI was greater for IPD than for MSA and controls in both the caudate nucleus and the putamen (p<0.05). There was significantly decreased perfusion in the left and right nucleus lentiformis in MSA compared to IPD and controls (p<0.05). CONCLUSION: Dual-isotope studies are both feasible in and promising for the diagnosis of parkinsonian syndromes.

Cysteine↗

Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging.

We describe a new approach to the problem of collimator optimization in nuclear medicine; our methodology is illustrated for the challenging case of gallium-67 imaging. Collimator-design methods based on empirical rules, such as specification of an allowable level of single-septal penetration (SSP) at a fixed energy, are especially inappropriate for radionuclides characterized by an abundance of high-energy contaminant photons that scatter in the patient, collimator, and/or detector before detection within one of a few photopeak energy windows. Lead X-rays produced in the collimator are an additional source of contamination. We designed optimal collimation for 67Ga based on relevant clinical imaging tasks and a realistic simulation of photon transport in a phantom, collimator, and detector. Collimator designs were compared on the basis of performance in lesion detection, as predicted by a three-channel Hotelling observer (CHO), as well as in tumor and background activity estimation (EST), quantified by task-specific signal-to-noise ratios (SNRs). The optimal values of collimator lead content were 22.0 and 23.8 g/cm2, respectively, for CHO and EST, while the optimal geometric resolution values were 1.8 and 1.6 cm full-width at half-maximum (FWHM), respectively, at a distance of 23.5 cm. The resolution of a commercially available medium-energy low-penetration collimator (MELP) is 1.9 cm FWHM at this distance. The optimal values for SSP at 300 keV were 7.3% and 5.8% based on CHO and EST, respectively, compared to 5.2% for the MELP collimator. Compared with the commercial MELP collimator, the 67Ga collimator optimized for tumor detection or activity estimation tasks provided improved geometric spatial resolution with reduced geometric efficiency and, surprisingly, allowed an increased level of single-septal penetration.

Citrates↗

Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses.

UNLABELLED: We have addressed 2 major challenges of (82)Rb cardiac PET, noninvasive estimation of an accurate input function and absolute quantitation of myocardial perfusion, using a generalized form of least-squares factor analysis of dynamic sequences (GFADS) and a novel compartment analysis approach. METHODS: Left and right ventricular (LV + RV) time-activity curves (TACs) were generated from 10 rest/stress studies, and 30 myocardial TACs were modeled to cover a range of clinical values. Two-dimensional PET Monte Carlo simulations of the LV, RV, myocardium, and other organs were generated separately and combined using the above TACs to form 30 realistic dynamic (82)Rb studies. LV and RV TACs were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (k(1)) and egress (k(2)), as well as LV + RV contributions (f(v), r(v)), by orthogonal voxel grouping. In addition, 13 patients were injected with 2.22 +/- 0.19 GBq (60 +/- 5 mCi) of (82)Rb and imaged dynamically for 6 min at rest and during dipyridamole stress. RESULTS: In Monte Carlo simulations, GFADS yielded estimates of the 3 factors and corresponding factor images, with average errors of -4.2% +/- 6.3%, 3.5% +/- 4.3%, and 2.0% +/- 5.5% in the LV, RV, and myocardial factor estimates, respectively. The estimates were significantly more accurate and robust to noise than those obtained using TACs based on manually drawn volumes of interest (P < 0.01). The 2-compartment approach yielded accurate k(1), k(2), f(v), and r(v) parametric maps; the average error of estimates of k(1) was 6.8% +/- 3.6%. In all patient studies, our approach yielded robust estimates of k(1), k(2), f(v), and r(v), which correlated very well with the status of the subject and the catheterization results. CONCLUSION: Quantitative dynamic (82)Rb PET using generalized factor analysis of dynamic sequences and compartmental modeling yields estimates of parameters of absolute myocardial perfusion and kinetics with errors of <9%.

Adult↗

Quantitative SPECT leads to improved performance in discrimination tasks related to prodromal Alzheimer's disease.

UNLABELLED: We investigated the impact of the quantitation and reconstruction protocol on clinical tasks. The performance of standard clinical reconstruction procedures in discrimination tasks related to the diagnosis of prodromal Alzheimer's disease (AD) was compared with the performance of a quantitative approach incorporating improved corrections for scatter, attenuation, intrinsic spatial resolution, and distance-dependent spatial resolution. METHODS: Seventeen normal controls (normal group), 56 subjects who did not have dementia, who did have memory problems, but who did not develop AD within 5 y of follow-up (questionable group), and 27 subjects who did not have dementia, who did have memory problems, and who did develop AD over the follow-up period (converter group) were considered in this study. (99m)Tc-hexamethylpropyleneamine oxime SPECT and MRI studies were performed for each subject at baseline. The standard quantitation protocol (STD), routinely used in our clinic, consisted of Compton window scatter correction followed by filtered backprojection with attenuation correction using a uniform attenuation map. In the improved quantitative approach (QUAN), projections were corrected for scatter by use of a general spectral method and reconstructed by use of ordered-subset(s) expectation maximization, incorporating corrections for collimator response and attenuation using both a uniform attenuation map (QUANunif) and a nonuniform attenuation map (QUANnonunif). Mean SPECT activity concentration and MRI volume were estimated for 7 structures: rostral anterior cingulate gyrus, caudal anterior cingulate gyrus, posterior cingulate gyrus, hippocampus, basal forebrain, amygdala, and the banks of the superior temporal sulcus. Data were analyzed by pairwise discriminant analysis, and performance in binary group discrimination was measured by correlated receiver-operating-characteristic analysis. RESULTS: The use of QUANnonunif yielded a small but systematic improvement in discrimination accuracy for normal versus converter groups (accuracy or area under the receiver-operating-characteristic curve [Az], 0.965), normal versus questionable groups (Az, 0.973), and questionable versus converter groups (Az, 0.881) compared with the results obtained with QUANunif (Az, 0.955, 0.962, and 0.866, respectively). Discrimination performance was significantly lower (P < 0.05) with STD than with QUAN in all 3 tasks (Az with STD, 0.906, 0.878, and 0.768, respectively). MRI volume estimation led to a lower overall performance in all 3 tasks than did QUANnonunif (Az with MRI, 0.947, 0.917, and 0.872, respectively). CONCLUSION: Improved quantitative image reconstruction with accurate compensation for scatter, attenuation, and variable collimator response led to significantly better performance in discrimination tasks related to the diagnosis of prodromal AD than did standard clinical reconstruction procedures. The use of a nonuniform brain attenuation map yields a small improvement in discrimination accuracy.

Aged↗

MRI-guided SPECT perfusion measures and volumetric MRI in prodromal Alzheimer disease.

OBJECTIVE: To identify group differences in the prodromal phase of Alzheimer disease (AD) using quantitative single-photon emission computed tomography (SPECT) perfusion and magnetic resonance imaging (MRI) volume measures within specific volumes of interest. SETTING: Gerontology research unit. PARTICIPANTS: There were 17 healthy controls, 56 nondemented patients with memory problems who did not develop AD during 3 to 5 years of follow-up (questionables), and 27 nondemented patients with memory problems who developed AD during follow-up (converters). METHODS: A Tc 99m hexamethylpropyleneamine oxime SPECT study and an MRI were performed in each participant at baseline. Mean SPECT activity concentration and MRI volume were estimated within 9 structures: rostral anterior cingulate, caudal anterior cingulate, posterior cingulate, hippocampus, entorhinal cortex, basal forebrain, temporal horn, amygdala, and the banks of the superior temporal sulcus. Data were analyzed using overall and pairwise discriminant analysis, and performance in pairwise group discrimination was measured using correlated receiver operating characteristic curve analysis. RESULTS: The overall (3-group) discriminant function was significant for SPECT (F test, P<.001) and MRI (F test, P<.0001). For the SPECT analysis, the ranking of structures for discriminating among the 3 groups was, in order of decreasing discriminating power, caudal anterior cingulate, temporal horn, superior temporal sulcus, entorhinal cortex, hippocampus, rostral anterior cingulate, amygdala, basal forebrain, and posterior cingulate. For the MRI analysis, this ranking was entorhinal cortex, superior temporal sulcus, temporal horn, hippocampus, amygdala, caudal anterior cingulate, rostral anterior cingulate, basal forebrain, and posterior cingulate. Combining the 2 modalities yielded significantly better discrimination performance than did either alone. Furthermore, the correlation between SPECT and MRI measures was low. CONCLUSION: Measures of structure activity concentration and volume carry independent information; both reveal group differences in prodromal AD.

Aged↗

Optimization of Ga-67 imaging for detection and estimation tasks: dependence of imaging performance on spectral acquisition parameters.

UNLABELLED: We have compared the use of two (93 and 185 keV) and three (93, 185, and 300 keV) photopeaks for Ga-67 tumor imaging and optimized the placement of each energy window. METHODS: The bases for optimization and evaluation were ideal and Bayesian signal-to-noise ratios (SNR) for the detection of spheres embedded in a realistic anthropomorphic digital torso phantom and ideal SNR for the estimation of their size and activity concentration. Seven spheres of radii ranging from 1 to 3 cm, located at several sites in the torso, were simulated using a realistic Monte Carlo program. We also calculated the ideal SNR for the detection from simple phantom acquisitions. RESULTS: For detection and estimation tasks, the optimum windows were identical for all sphere sizes and locations. For the 93 keV photopeak, the optimal window was 84-102 keV for the detection and 87-102 keV for estimation; these windows are narrower than the 20% window often used in the clinic (83-101 keV). For the 185 keV photopeak, the optimal window was 170-220 keV for the detection and 170-215 keV for estimation; these are substantially different than the 15% window used in our clinic (171-199 keV). For the 300 keV photopeak, the optimal window for detection was 270-320 keV, and for estimation, 280-320 keV. Using the three optimized, rather than only the two lower-energy, windows yielded a 9% increase in the SNR for the detection of the 3 cm diam sphere (a 12% increase for a 2 cm diam sphere) and a 7% increase in the SNR for estimation of its size. For the acquired phantom data, detection also increased by 9%-12% when using three, rather than two, energy windows.

Abdomen↗