PubMed Health⌕ Search

PubMed · 16229420

Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging.

Abstract

We describe a new approach to the problem of collimator optimization in nuclear medicine; our methodology is illustrated for the challenging case of gallium-67 imaging. Collimator-design methods based on empirical rules, such as specification of an allowable level of single-septal penetration (SSP) at a fixed energy, are especially inappropriate for radionuclides characterized by an abundance of high-energy contaminant photons that scatter in the patient, collimator, and/or detector before detection within one of a few photopeak energy windows. Lead X-rays produced in the collimator are an additional source of contamination. We designed optimal collimation for 67Ga based on relevant clinical imaging tasks and a realistic simulation of photon transport in a phantom, collimator, and detector. Collimator designs were compared on the basis of performance in lesion detection, as predicted by a three-channel Hotelling observer (CHO), as well as in tumor and background activity estimation (EST), quantified by task-specific signal-to-noise ratios (SNRs). The optimal values of collimator lead content were 22.0 and 23.8 g/cm2, respectively, for CHO and EST, while the optimal geometric resolution values were 1.8 and 1.6 cm full-width at half-maximum (FWHM), respectively, at a distance of 23.5 cm. The resolution of a commercially available medium-energy low-penetration collimator (MELP) is 1.9 cm FWHM at this distance. The optimal values for SSP at 300 keV were 7.3% and 5.8% based on CHO and EST, respectively, compared to 5.2% for the MELP collimator. Compared with the commercial MELP collimator, the 67Ga collimator optimized for tumor detection or activity estimation tasks provided improved geometric spatial resolution with reduced geometric efficiency and, surprisingly, allowed an increased level of single-septal penetration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephen C Moore, Marie Foley Kijewski, Georges El Fakhri. 2005. Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging.. https://doi.org/10.1109/tmi.2005.857211

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Enhanced stability of hydrogen peroxide in the presence of subsurface solids.

The stabilization of hydrogen peroxide was investigated as a basis for enhancing its downgradient transport and contact with contaminants during catalyzed H(2)O(2) propagations (CHP) in situ chemical oxidation (ISCO). Stabilization of hydrogen peroxide was investigated in slurries containing four characterized subsurface solids using phytate, citrate, and malonate as stabilizing agents after screening ten potential stabilizers. The extent of hydrogen peroxide stabilization and the most effective stabilizer were solid-specific; however, phytate was usually the most effective stabilizer, increasing the hydrogen peroxide half-life to as much as 50 times. The degree of stabilization was nearly as effective at 10 mM concentrations as at 250 mM or 1 M concentrations. The effect of stabilization on relative rates of hydroxyl radical activity varied between the subsurface solids, but citrate and malonate generally had a greater positive effect than phytate. The effect of phytate, citrate, and malonate on the relative rates of superoxide generation was minimal to somewhat negative, depending on the solid. The results of this research demonstrate that the stabilizers phytate, citrate, and malonate can significantly increase the half-life of hydrogen peroxide in the presence of subsurface solids during CHP reactions while maintaining a significant portion of the reactive oxygen species activity. Use of these stabilizers in the field will likely improve the delivery of hydrogen peroxide and downgradient treatment during CHP ISCO.

Citrates↗

Purification of plasmid DNA with polymer-salt aqueous two-phase system: optimization using response surface methodology.

An experimental design was used to optimize plasmid purification from an alkaline lysate of Escherichia coli cells using PEG-sodium citrate aqueous two-phase systems (ATPS), and to evaluate the influence of pH, PEG molecular weight, tie line length, phase volume ratio, and lysate load. To build the mathematical model and minimize the number of experiments for the design parameters, response surface methodology (RMS) with an orthogonal rotatable central composite design was defined based on the conditions found for the highest purification by preliminary tests. The adequacy of the calculated models for the plasmid recovery and remaining RNA were confirmed by means of variance analysis and additional experiments. Analysis of contours of constant response as a function of pH, PEG molecular weight, tie line length, and cell lysate load for three different phase volume ratios revealed different effects of these five factors on the studied parameters. Plasmid recovery of 99% was predicted for a system with PEG 400, pH 6.9, tie line length of 38.7%, phase volume ratio of 1.5, and lysate load of 10% (v/v). Under these conditions the predicted RNA removal was 68%.

Citrates↗

Theoretical studies of molecular structure and vibrational spectra of melaminium citrate.

The molecular geometry and vibrational frequencies of melaminium citrate in the ground state have been calculated using the Hartree-Fock (HF) and density functional method (B3LYP) with 6-31G(d) basis set. The optimized geometric bond lengths and bond angles obtained by using HF and density functional theory (DFT, B3LYP) show the best agreement with the experimental data. Comparison of the observed fundamental vibrational frequencies of melaminium citrate and calculated results by density functional B3LYP and Hartree-Fock methods indicate that B3LYP is superior to the scaled Hartree-Fock approach for molecular vibrational problems.

Citrates↗