PubMed Health⌕ Search

Biomedical subjects

Giuseppe Santoro

Publications and source records attributed to Giuseppe Santoro.

At least 37 records · Page 2Linked to original sources

Atrial function after surgical and percutaneous closure of atrial septal defect: a strain rate imaging study.

The effect of operation and the effect of the imposition of an occluding device on atrial function for patients with an atrial septal defect (ASD) has never been studied. Thus, the aim of this study was to evaluate for the first time both left atrial (LA) and right atrial (RA) function of children after transcatheter ASD closure with that of sex- and age-matched patients with surgically treated ASD, and sex- and age-matched control subjects using strain (epsilon) and epsilon rate imaging (SR). In all, 45 participants formed our studied sample: 15 patients after successful ASD device closure (ASD-D [atrial septal defect device closure] group, mean age: 9 +/- 3 years) and 15 age- and sex-matched patients after successful ASD surgical closure (ASD-S [atrial septal defect surgical closure] group, mean age: 9 +/- 3 years). All patients underwent ASD correction at least 6 months before the study. As a control group we selected 15 age- and sex-matched control subjects. In the ASD-S group the peak systolic epsilon and SR values were significantly reduced in both RA and LA when compared with control and ASD-D groups (P < .01). In the ASD-D group there was no significant difference in both LA and RA deformation properties when compared with control subjects. SR imaging indexes could provide new, noninvasive, clinically relevant insight on regional changes in atrial function for patients with ASD. ASD percutaneous closure is useful not only because it is less expensive and invasive than open-heart operation but also for its conservation of both LA and RA regional myocardial properties.

Atrial Function↗

Transcatheter palliation of congenital heart disease with reduced pulmonary blood flow.

BACKGROUND: Although surgical shunt is still considered as the best palliation of congenital heart disease with reduced pulmonary blood flow, stent implantation may be technically simpler, safer and more cost-effective than surgery in high-risk patients. This study evaluated the feasibility and results of this option in patients with duct-dependent pulmonary blood flow or systemic-to-pulmonary shunt malfunction. METHODS: Between April 2003 and July 2004, 9 patients (age 11 days-52 years, weight 2.1-52 kg) with complex congenital heart disease underwent stent implantation inside the patent ductus arteriosus (4 patients) or a stenotic surgical shunt (5 patients). RESULTS: The stenting procedure was successfully completed in all cases. The procedural time was 162 +/- 36 min (range 90-225 min). The fluoroscopy time was 33.8 +/- 6.8 min. No patient died. The morbidity rate was 22.2% (1 patient had local infection at the site of puncture and 1 had transient femoral artery pulse loss). After the procedure, the ductus/shunt diameter increased from 1.2 +/- 0.6 to 3.6 +/- 0.6 mm (p < 0.0001) and oxygen saturation improved from 74.0 +/- 6.5 to 85.2 +/- 3.3% (p < 0.01). Three patients underwent corrective surgery without technical problems after 8.0 +/- 1.0 months while oxygen saturation remained constantly >80% in patients still waiting for surgical repair (follow-up 5.3 +/- 3.1 months). CONCLUSIONS: Stent implantation is a technically feasible, safe and effective palliative option in high-risk surgical patients with congenital heart disease and reduced pulmonary blood flow. Although larger series are required to define the cost-effective clinical impact of this therapeutic option, it is reasonable to hypothesize a further extension of its indication even to elective and low-risk surgical patients.

Adolescent↗

Pulmonary artery stenting without angiographic imaging.

Pulmonary artery stenosis is a frequent complication seen after surgical repair of tetralogy of Fallot. In this setting, endovascular stent implantation is now accepted as the first-choice therapeutic option. However, angiographic imaging still being held as mandatory to check the stent position before final deployment, this procedure is not considered suitable for patients who cannot be submitted to angiography. In this paper, we report a novel method for the correct implantation of an endovascular stent without angiographic imaging. A 9-year-old boy underwent cardiac catheterization to relieve a severe left pulmonary artery stenosis. A previous attempt had been aborted due to a life-threatening anaphylactic reaction to the contrast medium. To avoid angiography, a contrast medium-filled compliant atrial septal defect sizing balloon (Amplatzer Sizing Balloon, AGA Medical Corporation) was used to image the vessel stenosis and successfully guide stent deployment. After the procedure, the transstenotic pressure gradient disappeared and the left-to-right pulmonary perfusion imbalance almost completely reverted.

Blood Vessel Prosthesis Implantation↗

Percutaneous treatment of moderate-to-large patent ductus arteriosus with different devices: early and mid-term results.

BACKGROUND: Transcatheter closure is now accepted as the first-choice therapeutic option in patients with patent ductus arteriosus (PDA). However, this procedure is still challenging in large PDA and/or younger patients. This study evaluated feasibility and results of this approach in large, symptomatic PDA using different devices. METHODS: Between April 2000 and July 2004, 57 patients underwent attempt of transcatheter closure of a large PDA at our Institution. Nineteen patients (33.3 %) were on pharmacologic therapy for congestive heart failure. PDA diameter was 3.2+/-1.2 mm (range 1.8-9 mm), resulting in a pulmonary to systemic flow ratio of 2.1+/-1.8 (range 1.4-5). RESULTS: The procedure was successfully performed in 54 patients (94.7%), using the Amplatzer duct occluder (ADO) device (34 patients) or a multiple detachable coil approach (20 patients). Complete PDA occlusion was recorded in 77.8% of patients at 24 hours, 92.6% at 1 month, and 94.4% at last follow-up control (23+/-12 months). PDA morphology and pulmonary to systemic flow ratio did not influence the success rate of the procedure or the residual shunt. A trend toward a higher occlusion rate at any follow-up point was recorded in the ADO group (79.5 vs 75.0% at 24 hours, 97.1 vs 85.0% at 1 month, and 97.1 vs 90% at last follow-up control, p = NS for all comparisons). CONCLUSIONS: Percutaneous closure might be considered effective and safe also in large, clinically significant PDA, by tailoring the device choice to the patient size and ductal morphology. In this setting, the multiple coil option revealed as effective as the ADO device over a mid-term follow-up.

Adolescent↗

Sarcoglycan subcomplex in normal human smooth muscle: an immunohistochemical and molecular study.

The sarcoglycans are transmembrane components of the dystrophin-glycoprotein complex, which links the cytoskeleton to the extracellular matrix in adult muscle fibers. Sarcoglycans seem to be functionally and pathologically as important as dystrophin. In the skeletal and cardiac muscle, the sarcoglycan subcomplex is a heterotetrameric unit composed of the transmembrane glycoproteins alpha-, beta-, gamma- and delta-sarcoglycan. A fifth sarcoglycan with significant homology to alpha-sarcoglycan, epsilon-sarcoglycan, has been identified; this sarcoglycan is expressed in both muscle and non-muscle cells. It is hypothesized that epsilon-sarcoglycan might replace alpha-sarcoglycan in smooth muscle, forming a novel sarcoglycan subcomplex consisting of epsilon-, beta-, gamma-, and delta-sarcoglycan. Recently, zeta-sarcoglycan, a novel sarcoglycan highly related to gamma-sarcoglycan and delta-sarcoglycan, has been identified. On this basis, growing evidence suggests that there are two types of sarcoglycan complex; one, in skeletal and cardiac muscle, consisting of alpha-, beta-, gamma- and delta-sarcoglycan; and the other, in smooth muscle, containing beta-, delta-, zeta- and epsilon-sarcoglycan. epsilon-sarcoglycan may be substituted for alpha-sarcoglycan in a subset of striated muscle complexes. Our results, obtained with immunofluorescence semi-quantitative analysis and molecular methods on smooth muscle biopsies of human adult gastroenteric tract, show for the first time that alpha-sarcoglycan fluorescence is also always detectable in smooth muscle, although its staining pattern is lower than epsilon-sarcoglycan. Normal alpha-sarcoglycan staining was detected at times, whereas there was reduced, but clearly detectable staining for epsilon-sarcoglycan. Moreover, gamma-sarcoglycan staining is always detectable in all analyzed biopsies. On the basis of our results, we would be able to hypothesize the existence of a pentameric or, considering zeta-sarcolgycan, a hexameric arrangement of the sarcoglycan subcomplex. The hexameric sarcoglycan subcomplex, in conformity with a larger or lower expression of single sarcoglycans, could characterize skeletal, cardiac or smooth muscle, or distinct parts of gastroenteric tract. It is intriguing to integrate these results with other vascular and urogenital smooth muscle, skeletal and cardiac muscle, while also analyzing zeta-sarcoglycan.

Adult↗

Analysis of right ventricular Doppler tissue imaging and load dependence in patients undergoing percutaneous closure of atrial septal defect.

In patients with volume overload due to atrial septal defect (ASD) and Doppler tissue imaging E'/A' <1 at baseline, right ventricular (RV) myocardial velocities show load independence after closure with a device. Conversely, in patients with ASD with basal E'/A' >1, regional velocities are load-dependent and positively correlate with RV dimension. Because RV Doppler tissue imaging velocities are still in the normal range 1 month after ASD closure, cardiac function does not seem to be affected by the presence of the occluder device.

Adolescent↗

Endothelial cell function in patients with Down's syndrome.

Patients with Down's syndrome show an increased pulmonary vascular reactivity that could be due to an impaired vascular endothelial function, which is possibly related to increased oxidative stress. In 8 patients with Down's syndrome and 9 euploid patients of similar age, endothelium-dependent and -independent vasodilation was studied, measuring brachial flow velocity with an intravascular Doppler flow wire. Patients with Down's syndrome showed a significant impairment of endothelial function versus controls. In presence of the antioxidant vitamin C, endothelium-dependent vasodilation in the patients with Down's syndrome was only slightly, but not significantly, improved.

Acetylcholine↗

Comparison of percutaneous closure of large patent ductus arteriosus by multiple coils versus the Amplatzer duct occluder device.

This study compared the efficacy and costs of the most used approaches for percutaneous closure of large patent ductus arteriosus, that is, multiple coils and the Amplatzer duct occluder (ADO) device. From April 2000 to September 2003, 47 patients underwent closure of large, symptomatic patent ductus arteriosus (diameter 4.6 +/- 3.0 mm/m(2); QP/QS 2.1 +/- 1.9) with multiple Cook detachable coils (n = 19) or the ADO device (n = 28). The multiple coil approach was significantly cheaper (1,389 +/- 168 vs 3,811 +/- 38, p <0.0001) but as effective as the ADO device over a mid-term follow-up (occlusion rate 89.5% vs 96.4%, p = NS).

Adolescent↗

Early electrical and geometric changes after percutaneous closure of large atrial septal defect.

Cardiac arrhythmias and right chamber enlargement are well known long-term sequelae of atrial septal defect (ASD). Surgical ASD closure relieves patient symptoms but often fails to revert cardiac volume overload findings. Transcatheter ASD closure might be an attractive alternative to surgery, also because of the possibility to study the amount and time-course of the electro-geometric modifications following shunt disappearance. Between March 2000 and December 2002, 24 patients (age 22.7 +16.8 years) underwent percutaneous closure of large ASD (stretched diameter >20 mm and/or QP/QS ratio >1.5:1). ASD closure was performed with the Amplatzer Septal Occluder device (mean 25 +/- 7 mm), achieving a complete occlusion in all patients at 1 month. In 6 patients, right ventricular (RV) monophasic action potential was recorded during the procedure. All patients underwent standard 12-lead electrocardiography and transthoracic echocardiography before and at 24 hours and 1 month after ASD closure. After the procedure, monophasic action potential length increased from 359 +/- 27 to 372 +/- 27 ms (p <0.0001). At 1 month, QT dispersion decreased from 54 +/- 25 to 41 +/- 17 ms (p <0.05), RV diastolic diameter decreased from 42 +/- 6 to 34 +/- 5 mm (p <0.00001), and left ventricular (LV) diastolic diameter increased from 39 +/- 5 to 44 +/- 5 mm (p <0.0001), resulting in a decrease in the RV/LV ratio from 1.11 +/- 0.22 to 0.79 +/- 0.11 (-28.8%, p <0.00001). Electrocardiographic changes, as well as the amount and time-course of RV overload relief, did not significantly differ between pediatric (<16 years of age; n = 11) and adult patients (n = 13). In conclusion, regardless of age at procedure, percutaneous ASD closure results in early striking electrical and geometric cardiac changes that may be beneficial during long-term follow-up.

Action Potentials↗

Ultrastructural changes of corpora cavernosa in men with erectile dysfunction and chronic renal failure.

Erectile dysfunction (ED) is a common and often distressing side effect of renal failure. Uremic men of different ages report a high variety of sexual problems, including sexual hormonal pattern alterations, reduced or loss of libido, infertility, and impotence, thereby influencing their well-being. The pathogenic mechanisms include physiologic, psychologic, and organic causes. To determine the contribution of morphologic factors to impotence we studied the ultrastructure of the corpora cavernosa in 20 patients with end-stage renal disease who were treated with chronic dialysis and compared the findings with 6 individuals with no clinical history of impotence. Our results indicated that in male uremic patients with sexual disturbances there were major changes in smooth muscle cells. This was characterized by reduction of dense bodies in the cytoplasm, thick basement membranes, and increased interstitial collagen fibers with resultant reduction of cell-to-cell contact. In addition, there was thickening and lamination of basement membranes of endothelial cells and increased accumulation of collagen between nerve fibers. These alterations were more evident in patients with longer time on dialysis and were independent of type of primary renal disease. We hypothesize that ED in dialysis patients is not related to the primary disease but to the uremic state.

Adult↗

Electrophysiological changes following balloon valvuloplasty and angioplasty for aortic stenosis and coartaction of aorta: clinical evidence for mechano-electrical feedback in humans.

BACKGROUND: Basic research and animal experiments have shown electrophysiological changes during or after changes in mechanical loading. Electrical instability following mechanical stretch has been observed as development of after-depolarisation and dispersion of refractoriness and repolarisation. The aim of the present study was to evaluate the presence of the mechano-electrical feedback in humans, assessing the ventricular repolarisation changes following acute changes in left ventricular pressure. MATERIAL AND METHODS: The study group comprised 30 consecutive patients (22 M and 8 F, aged 2 days-24 years) affected by severe congenital aortic stenosis and 30 patients (20 M and 10 F, aged 6 months-16 years) affected by severe coartaction of aorta. Ventricular repolarisation was evaluated before and after percutaneous balloon valvuloplasty and angioplasty in terms of absolute measures (JT, JTc, QT, QTc) and in terms of dispersion across the myocardium: QT and QTc dispersion (QTD, QTcD), JT and JTc dispersion (JTD and JTcD) and T-peak to T-end interval (Tp-Te). RESULTS: Patients with severe aortic stenosis and patients with aortic coartaction showed a significant decrease in dispersion of ventricular repolarisation time indexes (QTD, QTcD, JTD, JTcD and Tp-Te) following valvuloplasty and angioplasty. CONCLUSIONS: Changes in hemodynamic loading can also produce electrophysiological effects in humans. Acute reduction in left ventricular pressure overload following balloon valvuloplasty and angioplasty, decreases electrical instability, as expressed by the reduction across the myocardium of the dispersion of ventricular repolarisation.

Adolescent↗

Isolated anomalous origin of the right pulmonary artery from the ascending aorta (so-called "hemitruncus"): diagnosis and complex management in a newborn.

We report a case of an anomalous origin of the right pulmonary artery (RPA) from the ascending aorta diagnosed at echocardiography at 13 days of age. The diagnostic clue was relieved in the suprasternal and parasternal high short-axis views, showing aorto-RPA continuity with a systolic flow in the left pulmonary artery and a systo-diastolic flow in the RPA. At 34 days of age the infant was submitted to surgery during which a direct end-to-lateral anastomosis without conduit interposition was performed. During the short-term follow-up the patient developed RPA stenosis at the anastomosis site and underwent percutaneous stent implantation.

Anastomosis, Surgical↗

Evaluation of sarcoglycans, vinculin-talin-integrin system and filamin2 in alpha- and gamma-sarcoglycanopathy: an immunohistochemical study.

The sarcoglycan subcomplex (SGC) is a well-known system of interaction between extracellular matrix and sarcolemma-associated cytoskeleton in skeletal and cardiac muscle. The SGC is included in the DGC made up of sarcoplasmic subcomplex and a dystroglycan subcomplex. Recent developments in molecular genetics have demonstrated that the mutation of each single sarcoglycan gene, causes a series of recessive autosomal muscular dystrophies, dystrophin-positive, called sarcoglycanopathies or limb girdle muscular dystrophies. Our recent studies have demonstrated that costameres are a proteic machinery made up of DGC and vinculin-talin-integrin system, also revealing the colocalization of sarcoglycans and integrins in adult human skeletal muscle. These results may support the hypothesis of the existence of a bidirectional signalling between sarcoglycans and integrins in cultured L6 myocytes. The hypothesis of bidirectional signalling between sarcoglycans and integrins could be supported by the identification of a skeletal and cardiac muscle filamin2 as a gamma-sarcoglycan, delta-sarcoglycan and, hypothetically, beta1 integrin interacting protein. Our results, acquired with an immunofluorescence study on adult human skeletal muscle affected by LGMD type 2D and 2C, showed that in LGMD2D: a) alpha-sarcoglycan staining is severely reduced; b) the beta-gamma-delta-sarcoglycan subunit and all tested integrins staining are clearly detectable; c) filamin2 is normal and shows a costameric distribution. In LGMD2C: a) alpha-sarcoglycan staining is preserved; b) the beta-gamma-delta-sarcoglycan subunit staining is severely reduced; c) the alpha7B-integrin is slightly reduced and beta1D-integrin is severely reduced; d) filamin2 is severely reduced. Other tested proteins of the two systems show a normal staining pattern in both sarcoglycanopathies. Our study seems to confirm, for the first time on adult human skeletal muscle of subjects affected by LGMDs, the hypo-theses of: a) the existence, in mouse myotubes in culture, of two distinct subunits in sarcoglycans subcomplex; b) the presence of a bidirectional signalling between sarcoglycans and integrins, previously demonstrated on rat cultured L6 myocytes; c) the interaction of FLN2 with both sarcoglycans and integrins. These results may stimulate the search of yet unidentified common interactors of both fiber-extracellular matrix interaction systems.

Biopsy↗

One-step treatment of patent ductus arteriosus and pulmonary artery stenosis by cardiac catheterization.

Coexistence of pulmonary artery (PA) stenosis and patent ductus arteriosus (PDA) may lead to overestimating the relative importance of these malformations. This article reports on a patient with a trivial PDA and severe PA stenosis erroneously diagnosed as moderate PDA. He was successfully submitted to simultaneous PA stenting and PDA embolization.

Blood Vessel Prosthesis Implantation↗