PubMed Health⌕ Search

Biomedical subjects

Glenn M Walker

Publications and source records attributed to Glenn M Walker.

6 recordsLinked to original sources

Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator.

An understanding of chemotaxis at the level of cell-molecule interactions is important because of its relevance in cancer, immunology, and microbiology, just to name a few. This study quantifies the effects of flow on cell migration during chemotaxis in a microfluidic device. The chemotaxis gradient within the device was modeled and compared to experimental results. Chemotaxis experiments were performed using the chemokine CXCL8 under different flow rates with human HL60 promyelocytic leukemia cells expressing a transfected CXCR2 chemokine receptor. Cell trajectories were separated into x and y axis components. When the microchannel flow rates were increased, cell trajectories along the x axis were found to be significantly affected (p < 0.05). Total migration distances were not affected. These results should be considered when using similar microfluidic devices for chemotaxis studies so that flow bias can be minimized. It may be possible to use this effect to estimate the total tractile force exerted by a cell during chemotaxis, which would be particularly valuable for cells whose tractile forces are below the level of detection with standard techniques of traction-force microscopy.

Cell Line, Tumor↗

Microfluidic glucose stimulation reveals limited coordination of intracellular Ca2+ activity oscillations in pancreatic islets.

The pancreatic islet is a functional microorgan involved in maintaining normoglycemia through regulated secretion of insulin and other hormones. Extracellular glucose stimulates insulin secretion from islet beta cells through an increase in redox state, which can be measured by NAD(P)H autofluorescence. Glucose concentrations over approximately 7 mM generate synchronous oscillations in beta cell intracellular Ca2+ concentration ([Ca2+]i), which lead to pulsatile insulin secretion. Prevailing models assume that the pancreatic islet acts as a functional syncytium, and the whole islet [Ca2+]i response has been modeled in terms of islet bursting and pacemaker models. To test these models, we developed a microfluidic device capable of partially stimulating an islet, while allowing observation of the NAD(P)H and [Ca2+]i responses. We show that beta cell [Ca2+]i oscillations occur only within regions stimulated with more than approximately 6.6 mM glucose. Furthermore, we show that tolbutamide, an antagonist of the ATP-sensitive K+ channel, allows these oscillations to travel farther into the nonstimulated regions of the islet. Our approach shows that the extent of Ca2+ propagation across the islet depends on a delicate interaction between the degree of coupling and the extent of ATP-sensitive K+-channel activation and illustrates an experimental paradigm that will have utility for many other biological systems.

Animals↗

Microenvironment design considerations for cellular scale studies.

In vivo cellular microenvironments are not well-mimicked in present in vitro cell culture systems. Microtechnology, and microfluidics in particular, provides the tools to create in vivo-like cellular microenvironments in vitro. Features of in vitro cellular microenvironments are discussed and compared to macroscale cell culture environments; the concept of an effective culture volume (ECV) is introduced to facilitate the comparison. Current research using microtechnology to investigate in vitro cellular microenvironments is presented and areas where more research is needed in characterizing the in vitro microenvironment are outlined.

Adsorption↗

A passive pumping method for microfluidic devices.

The surface energy present in a small drop of liquid is used to pump the liquid through a microchannel. The flow rate is determined by the volume of the drop present on the pumping port of the microchannel. A flow rate of 1.25 microL s(-1) is demonstrated using 0.5 microL drops of water. Two other fluid manipulations are demonstrated using the passive pumping method: pumping liquid to a higher gravitational potential energy and creating a plug within a microchannel.

Journal Article↗

An evaporation-based microfluidic sample concentration method.

We present a method for sample concentration within microfluidic devices using evaporation-induced flow. Evaporation-induced flow is easy to incorporate into microfluidic designs and can be used to concentrate a wide variety of molecules. The practicality of this method was demonstrated with 0.2 microm fluorescent spheres and FITC-labeled BSA. Thirty two percent of the 0.6 microL fluorescent sphere suspension was concentrated into a well within a microfluidic device. In the same amount of time, 93% of the 0.6 microL FITC-labeled BSA solution was concentrated.

Journal Article↗

Physics and applications of microfluidics in biology.

Fluid flow at the microscale exhibits unique phenomena that can be leveraged to fabricate devices and components capable of performing functions useful for biological studies. The physics of importance to microfluidics are reviewed. Common methods of fabricating microfluidic devices and systems are described. Components, including valves, mixers, and pumps, capable of controlling fluid flow by utilizing the physics of the microscale are presented. Techniques for sensing flow characteristics are described and examples of devices and systems that perform bioanalysis are presented. The focus of this review is microscale phenomena and the use of the physics of the scale to create devices and systems that provide functionality useful to the life sciences.

Biosensing Techniques↗