PubMed Health⌕ Search

Biomedical subjects

Grace W Muna

Publications and source records attributed to Grace W Muna.

2 recordsLinked to original sources

Chlorinated phenol analysis using off-line solid-phase extraction and capillary electrophoresis coupled with amperometric detection and a boron-doped diamond microelectrode.

The analysis of chlorinated phenols (2-chlorophenol, 3-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in river water was accomplished using off-line solid-phase extraction (SPE) and capillary electrophoresis coupled with electrochemical detection. A key to the sensitive, reproducible, and stable detection of these pollutants was the use of a boron-doped diamond microelectrode in the amperometric detection mode. An off-line SPE procedure was utilized to extract and preconcentrate the pollutants prior to separation and detection, with ENVI-Chrom P, a highly cross-linked styrene-divinylbenzene copolymer, being employed as the sorbent. Pollutant recoveries in the 95-100% range with relative standard deviations of 1-4% were achieved. The diamond microelectrode provided a low and stable background current with low peak-to-peak noise. The oxidative detection of the pollutants was accomplished at +1.05 V vs Ag/AgCl without the need for electrode pretreatment. The method was evaluated in terms of the linear dynamic range, sensitivity, limit of quantitation, response precision, and response stability. A reproducible electrode response was observed during multiple injections of the chlorinated phenol solutions with a relative standard deviation of < or =5.4%. Good electrode response stability was observed over many days of continuous use with no significant electrode deactivation or fouling. The separation efficiencies for all six pollutants were greater than 170,000 plates/m. The minimum concentration detectable for all six ranged from 0.02 to 0.2 ppb (S/N > or = 3) using a 250:1 preconcentration factor.

Boron↗

Electro-oxidation and amperometric detection of chlorinated phenols at boron-doped diamond electrodes: a comparison of microcrystalline and nanocrystalline thin films.

We report on the electro-oxidation and amperometric detection of phenol and chlorinated phenols, the latter coupled with flow injection analysis (FIA) and high performance liquid chromatography (HPLC), using boron-doped microcrystalline and nanocrystalline diamond thin-film electrodes. The low background current, good response without extensive pretreatment, and low susceptibility to fouling are properties that make diamond an attractive new electrode for monitoring this class of pollutants. Cyclic voltammetric studies were performed to evaluate the redox response of phenol, 2-chlorophenol, 3-chlorophenol,4-chlorophenol, and pentachlorophenol (PCP) in phosphate buffer, pH 3.5, as a function of the potential scan rate and cycle number. The diamond electrode performance for the amperometric detection of these contaminants in FIA-EC and HPLC-EC was evaluated in terms of the linear dynamic range, limit of quantitation, sensitivity, response precision, and response stability. Both diamond types yielded low mass limits of quantitation of 100-1000 pg for all the phenolic compounds in FIA-EC, except PCP which was 3 ng, and 100-600 pg for all the compounds in HPLC-EC. In all cases, the S/N was 3 or greater. Both electrode types also exhibited good sensitivity, excellent response reproducibility (av 2.7% for FIA-EC and av 4.2% for HPLC-EC), and superb response stability for all the analytes. The electrodes could be used from days to weeks in the measurement with only a periodic soak in distilled 2-propanol required to maintain optimum performance. Both types of diamond outperformed glassy carbon, which exhibited short-lived responsiveness as a consequence of fouling by reaction products and potential-dependent changes in the electrode's physiochemical properties. The use of the HPLC-EC assay for the determination of 2-chlorophenol in a contaminated soil sample is also demonstrated.

Boron↗