PubMed Health⌕ Search

PubMed · 16223238

Chlorinated phenol analysis using off-line solid-phase extraction and capillary electrophoresis coupled with amperometric detection and a boron-doped diamond microelectrode.

Abstract

The analysis of chlorinated phenols (2-chlorophenol, 3-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in river water was accomplished using off-line solid-phase extraction (SPE) and capillary electrophoresis coupled with electrochemical detection. A key to the sensitive, reproducible, and stable detection of these pollutants was the use of a boron-doped diamond microelectrode in the amperometric detection mode. An off-line SPE procedure was utilized to extract and preconcentrate the pollutants prior to separation and detection, with ENVI-Chrom P, a highly cross-linked styrene-divinylbenzene copolymer, being employed as the sorbent. Pollutant recoveries in the 95-100% range with relative standard deviations of 1-4% were achieved. The diamond microelectrode provided a low and stable background current with low peak-to-peak noise. The oxidative detection of the pollutants was accomplished at +1.05 V vs Ag/AgCl without the need for electrode pretreatment. The method was evaluated in terms of the linear dynamic range, sensitivity, limit of quantitation, response precision, and response stability. A reproducible electrode response was observed during multiple injections of the chlorinated phenol solutions with a relative standard deviation of < or =5.4%. Good electrode response stability was observed over many days of continuous use with no significant electrode deactivation or fouling. The separation efficiencies for all six pollutants were greater than 170,000 plates/m. The minimum concentration detectable for all six ranged from 0.02 to 0.2 ppb (S/N > or = 3) using a 250:1 preconcentration factor.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Grace W Muna, Veronika Quaiserová-Mocko, Greg M Swain. 2005-10-15. Chlorinated phenol analysis using off-line solid-phase extraction and capillary electrophoresis coupled with amperometric detection and a boron-doped diamond microelectrode.. https://doi.org/10.1021/ac050473u

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Towards design of the smallest planar tetracoordinate carbon and boron systems.

A series of cyclic hydrocarbons analogs where a carbon displays unusual planar tetracoordinate structure is proposed, employing hybrid density functional theory calculations using B3LYP functional and 6-311+G** basis set. Various strategies were employed to design the neutral planar tetracoordinate hydrocarbon analogs. The same strategy is employed for designing the planar tetracoordinate boron systems. The simplest neutral planar tetracoordinate hydrocarbons were proposed and the effect of substitution on their stability has been assessed. The aromatic stabilization is gauged with nucleus independent chemical shift calculations. The activation barriers for the ring opening reaction, the highest occupied molecular orbital and lowest unoccupied molecular orbitals gap and singlet-triplet energy difference were estimated to gauge the plausibility experimental realization.

Boron↗

Structure and electrochemical properties of carbon films prepared by a electron cyclotron resonance sputtering method.

This paper describes the characterization, electrochemical properties, and applications of carbon films prepared by the electron cyclotron resonance (ECR) sputtering method. The ECR-sputtered carbon film was deposited within several minutes at room temperature. The optimized sputtering conditions significantly change the film structure, which includes many more sp3 bonds (sp3/sp2 = 0.702) than previously reported film (sp3/sp2 = 0.274)1 with an extremely flat surface (0.7 A). The ECR-sputtered carbon films exhibit excellent electrochemical properties. For example, they have nearly the same potential window in the positive direction as that of high-quality, boron-doped diamond (moderately doped, 10(19)-10(20) boron atoms/cm3)2 and an even wider potential window in the negative direction with a low background current, high stability, and suppression of fouling by electroactive species without pretreatment. The electron-transfer rates at ECR-sputtered carbon films are similar to those of glassy carbon (GC) for Ru(NH3)(6)(2+)/(3+) and Fe(CN)(6)(3-)/(4-), whereas they are much slower than those of GC for Fe2+/3+, dopamine oxidation, and O2 reduction due to weak interactions between electroactive species and the ECR-sputtered carbon film surface. Such a response can be attributed to the ultraflat surface and low surface O/C ratios of ECR-sputtered carbon films. ECR-sputtered carbon film is advantageous for measuring biochemicals with high oxidation potentials because of its wide potential window and high stability. Highly reproducible and well-defined cyclic voltammograms were obtained for histamine and azide ions with a peak potential at 1.25 and 1.12 V vs Ag/AgCl, respectively. The film is very stable for continuous voltammetry measurements in 10 microM bisphenol A, which usually fouls the electrode surface with oxidation products.

Boron↗