In vitro continuous amperometric monitoring of 5-hydroxytryptamine release from enterochromaffin cells of the guinea pig ileum.

A diamond microelectrode was used to sensitively, reproducibly and stably record overflow of 5-hydroxytryptamine (5-HT, serotonin) from enterochromaffin cells (EC) of the intenstinal mucosal layer. 5-HT is an important neurotransmitter and paracrine signalling molecule in the gastrointestinal tract. The diamond microelectrode was formed by overcoating a sharpened 76 microm diameter Pt wire with a thin layer of conducting diamond. After insulation with polypropylene, the conically-shaped microelectrode had a diameter of about 10 microm at the tip and 80 microm at the cylindrical portion. The exposed length was 100-200 microm. Continuous amperometry with the microelectrode poised at a detection potential of 700 mV vs. Ag|AgCl was used to measure 5-HT overflow as an oxidation current. 5-HT overflow was elicited by both mechanical and electrical stimulation. Some minor electrode fouling, a common problem with the oxidative detection of 5-HT, was seen for diamond but the response stabilized enabling recording in vitro. Both 5-HT and the paracrine hormone, melatonin, were detected in the extracellular solution. The 5-HT oxidation current increased in the presence of the serotonin transporter (SERT) inhibitor, fluoxetine (1 microM), providing evidence that the oxidation current was associated with 5-HT.

Animals↗

In vitro continuous amperometry with a diamond microelectrode coupled with video microscopy for simultaneously monitoring endogenous norepinephrine and its effect on the contractile response of a rat mesenteric artery.

Continuous amperometry with a diamond microelectrode and video microscopy were used to record (in vitro) endogenous norepinephrine release simultaneously with the evoked contractile response of a mesenteric artery from a healthy Sprague Dawley rat. Norepinephrine (NE) is a vasoconstricting neurotransmitter released from sympathetic nerves that innervate the smooth muscle cell layers surrounding arteries and veins. Using these two techniques along with several drugs, the NE released at sympathetic neuroeffector junctions nearby the microelectrode was measured as an oxidation current. Key to the amperometric measurement was the use of a diamond microelectrode because of the response sensitivity, reproducibility, and stability it provided. NE release was elicited by electrical stimulation at frequencies between 1 and 60 Hz, with a maximum response seen at 20 Hz. Confirmation that the oxidation current was, in fact, associated with endogenous NE came from the results of several drugs. Tetrodotoxin (TTX, 0.3 microM), a voltage-dependent sodium channel antagonist that blocks nerve conduction, abolished both the oxidation current and the arterial constriction. The alpha(2)-adrenergic autoreceptor antagonist, yohimbine (1.0 microM), caused an increase in the oxidation current and the corresponding constriction. The addition of cocaine (10 microM), an antagonist that inhibits neuronal NE reuptake, caused both the oxidation current and the contractile response to increase. These results, combined with the fact that the hydrodynamic voltammetric E(1/2) for endogenous NE was identical to that for a standard solution, confirmed that the oxidation current was due to NE and that this compound caused, at least in part, the contractile response. The results demonstrate that continuous amperometric monitoring of NE with a diamond microelectrode and video imaging of vascular tone allow real time local measurement of the temporal relationship between nerve-stimulated NE release and arterial constriction.

Animals↗

Chlorinated phenol analysis using off-line solid-phase extraction and capillary electrophoresis coupled with amperometric detection and a boron-doped diamond microelectrode.

The analysis of chlorinated phenols (2-chlorophenol, 3-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in river water was accomplished using off-line solid-phase extraction (SPE) and capillary electrophoresis coupled with electrochemical detection. A key to the sensitive, reproducible, and stable detection of these pollutants was the use of a boron-doped diamond microelectrode in the amperometric detection mode. An off-line SPE procedure was utilized to extract and preconcentrate the pollutants prior to separation and detection, with ENVI-Chrom P, a highly cross-linked styrene-divinylbenzene copolymer, being employed as the sorbent. Pollutant recoveries in the 95-100% range with relative standard deviations of 1-4% were achieved. The diamond microelectrode provided a low and stable background current with low peak-to-peak noise. The oxidative detection of the pollutants was accomplished at +1.05 V vs Ag/AgCl without the need for electrode pretreatment. The method was evaluated in terms of the linear dynamic range, sensitivity, limit of quantitation, response precision, and response stability. A reproducible electrode response was observed during multiple injections of the chlorinated phenol solutions with a relative standard deviation of < or =5.4%. Good electrode response stability was observed over many days of continuous use with no significant electrode deactivation or fouling. The separation efficiencies for all six pollutants were greater than 170,000 plates/m. The minimum concentration detectable for all six ranged from 0.02 to 0.2 ppb (S/N > or = 3) using a 250:1 preconcentration factor.

Boron↗

Electro-oxidation and amperometric detection of chlorinated phenols at boron-doped diamond electrodes: a comparison of microcrystalline and nanocrystalline thin films.

We report on the electro-oxidation and amperometric detection of phenol and chlorinated phenols, the latter coupled with flow injection analysis (FIA) and high performance liquid chromatography (HPLC), using boron-doped microcrystalline and nanocrystalline diamond thin-film electrodes. The low background current, good response without extensive pretreatment, and low susceptibility to fouling are properties that make diamond an attractive new electrode for monitoring this class of pollutants. Cyclic voltammetric studies were performed to evaluate the redox response of phenol, 2-chlorophenol, 3-chlorophenol,4-chlorophenol, and pentachlorophenol (PCP) in phosphate buffer, pH 3.5, as a function of the potential scan rate and cycle number. The diamond electrode performance for the amperometric detection of these contaminants in FIA-EC and HPLC-EC was evaluated in terms of the linear dynamic range, limit of quantitation, sensitivity, response precision, and response stability. Both diamond types yielded low mass limits of quantitation of 100-1000 pg for all the phenolic compounds in FIA-EC, except PCP which was 3 ng, and 100-600 pg for all the compounds in HPLC-EC. In all cases, the S/N was 3 or greater. Both electrode types also exhibited good sensitivity, excellent response reproducibility (av 2.7% for FIA-EC and av 4.2% for HPLC-EC), and superb response stability for all the analytes. The electrodes could be used from days to weeks in the measurement with only a periodic soak in distilled 2-propanol required to maintain optimum performance. Both types of diamond outperformed glassy carbon, which exhibited short-lived responsiveness as a consequence of fouling by reaction products and potential-dependent changes in the electrode's physiochemical properties. The use of the HPLC-EC assay for the determination of 2-chlorophenol in a contaminated soil sample is also demonstrated.

Boron↗

Electrochemical performance of diamond thin-film electrodes from different commercial sources.

The electrochemical properties of two commercial (Condias, Sumitomo) boron-doped diamond thin-film electrodes were compared with those of two types of boron-doped diamond thin film deposited in our laboratory (microcrystalline, nanocrystalline). Scanning electron microscopy and Raman spectroscopy were used to characterize the electrode morphology and microstructure, respectively. Cyclic voltammetry was used to study the electrochemical response, with five different redox systems serving as probes (Fe(CN)(6)(3)(-)(/4)(-), Ru(NH(3))(6)(3+/)(2+), IrCl(6)(2)(-)(/3)(-), 4-methylcatechol, Fe(3+/2+)). The response for the different systems was quite reproducibile from electrode type to type and from film to film for electrodes of the same type. For all five redox systems, the forward reaction peak current varied linearly with the scan rate(1/2) (nu), indicative of electrode reaction kinetics controlled by mass transport (semi-infinite linear diffusion) of the reactant. Apparent heterogeneous electron-transfer rate constants, k degrees (app), for all five redox systems were determined from deltaE(p)-nu experimental data, according to the method described by Nicholson (Nicholson, R. S. Anal. Chem. 1965, 37, 1351.). The rate constants were also verified through digital simulation (DigiSim 3.03) of the voltammetric i-E curves at different scan rates. Good fits between the experimental and simulated voltammograms were found for scan rates up to 50 V/s. k degrees (app) values of 0.05-0.5 cm/s were observed for Fe(CN)(6)(3)(-)(/4)(-), Ru(NH(3))(6)(3+/2+), and IrCl(6)(2)(-)(/3)(-) without any extensive electrode pretreatment (e.g., polishing). Lower k degrees (app) values of 10(-)(4)-10(-)(6) cm/s were found for 4-methylcatechol and Fe(3+/2+). The voltammetric responses for Fe(CN)(6)(3)(-)(/4)(-) and Ru(NH(3))(6)(3+/2+) were also examined at all four electrode types at two different solution pH (1.90, 7.35). Since the hydrogen-terminated diamond surfaces contain few, if any, ionizable carbon-oxygen functionalities (e.g., carboxylic acid, pK(a) approximately 4.5), the deltaE(p), i(p)(ox), and i(p)(red) values for the two systems were, for the most part, unaffected by the solution pH. This is in contrast to the typical behavior of oxygenated, sp(2) carbon electrodes, such as glassy carbon.

Boron↗

Boron-doped diamond microelectrodes for use in capillary electrophoresis with electrochemical detection.

The fabrication and characterization of boron-doped diamond microelectrodes for use in electrochemical detection coupled with capillary electrophoresis (CE-EC) is discussed. The microelectrodes were prepared by coating thin films of polycrystalline diamond on electrochemically sharpened platinum wires (76-, 25-, and 10-microm diameter), using microwave-assisted chemical vapor deposition (CVD). The diamond-coated wires were attached to copper wires (current collectors), and several methods were explored to insulate the cylindrical portion of the electrode: nail polish, epoxy, polyimide, and polypropylene coatings. The microelectrodes were characterized by scanning electron microscopy, Raman spectroscopy, and cyclic voltammetry. They exhibited low and stable background currents and sigmoidally shaped voltammetric curves for Ru(NH3)6(3+/2+) and Fe(CN)6(3-/4-) at low scan rates. The microelectrodes formed with the large diameter Pt and sealed in polypropylene pipet tips were employed for end-column detection in CE. Evaluation of the CE-EC system and the electrode performance were accomplished using a 10 mM phosphate buffer, pH 6.0, run buffer, and a 30-cm-long fused-silica capillary (75-microm i.d.) with dopamine, catechol, and ascorbic acid serving as test analytes. The background current (approximately 100 pA) and noise (approximately 3 pA) were measured at different detection potentials and found to be very stable with time. Reproducible separation (elution time) and detection (peak current or area) of dopamine, catechol, and ascorbic acid were observed with response precisions of 4.1% or less. Calibration curves constructed from the peak area were linear over 4 orders of magnitude, up to a concentration between 0.1 and 1 mM. Mass limits of detection for dopamine and catechol were 1.7 and 2.6 fmol, respectively (S/N = 3). The separation efficiency was approximately 33,000, 56,000, and 98,000 plates/m for dopamine, catechol, and ascorbic acid, respectively. In addition, the separation and detection of 1- and 2-naphthol in 160 mM borate buffer, pH 9.2, was investigated. Separation of these two analytes was achieved with efficiencies of 118,000 and 126,000 plates/m, respectively.

Ascorbic Acid↗

Optical and electrochemical properties of optically transparent, boron-doped diamond thin films deposited on quartz.

The optical and electrochemical properties of transparent, boron-doped diamond thin film, deposited on quartz, are discussed. The films were deposited by microwave-assisted chemical vapor deposition, for 1-2 h, using a 0.5% CH4/H2 source gas mixture at 45 Torr and 600 W of power. A high rate of diamond nucleation was achieved by mechanically scratching the quartz. This pretreatment leads to the formation of a continuous film, in a short period of time, which consists of nanometer-sized grains of diamond. The thin-film electrode was characterized by cyclic voltammetry, atomic force microscopy, and UV-visible absorption spectrophotometry. The film's electrochemical response was evaluated using Ru(NH3)6(3+/2+) in 1 M KCl, Fe(CN)6(3-/4-) in 1 M KCl, and chlorpromazine (CPZ) in 10 mM HClO4. The film exhibited a low voltammetric background current and a stable and active voltammetric response for all three redox systems. The optical transparency of the polycrystalline film in the visible region was near 50% and fairly constant between 300 and 800 nm. The optical and electrical properties were extremely stable during 48-h exposure tests in various aqueous (HNO3, NaOH) solutions and nonaqueous (e.g., chlorinated) solvents. The properties were also extremely stable during anodic and cathodic potential cycling in harsh aqueous environments. This stability is in stark contrast to what was observed for an indium-doped tin oxide thin film coated on quartz. The spectroelectrochemical response (transmission mode) for CPZ was studied in detail, using a thin-layer spectroelectrochemical cell. Thin-layer voltammetry, potential step/ absorption measurements, and detection analytical figures of merit are presented. The results demonstrate that durable, stable, and optically transparent diamond thin films, with low electrical resistivity (approximately 0.026 omega x cm) laterally through the film, can be deposited on quartz.

Journal Article↗

Direct electrochemistry of cytochrome C at nanocrystalline boron-doped diamond.

Direct electron transfer of horse heart cytochrome c is measured at a nanocrystalline boron-doped diamond thin-film electrode. A quasi-reversible, diffusion-controlled cyclic voltammetric response is observed for untreated diamond. The peak currents change linearly with the concentration, and importantly, there is no electrode fouling. The results, observed for a hydrogen-terminated and uncharged surface, (i.e., no ionizable carbon-oxygen functional groups), raise interesting questions about the necessary surface interactions of cytochrome c for relatively rapid electrode kinetics.