Converting insertion gain to and from headphone coupler responses.

OBJECTIVE: The paper aims to show how insertion gain responses can be translated into equivalent headphone responses, and vice versa. DESIGN: The relationship between the response types is theoretically derived by allowing for real ear to coupler differences and for real ear unaided responses. RESULTS: The necessary corrections for each of these factors are obtained from published data, and the combined correction factors are compared with independently obtained published data. CONCLUSIONS: The equations and data presented can be used to translate insertion gain responses into responses suitable for use with equipment using headphones and, by inference, insert phones.

Hearing Aids↗

Client Oriented Scale of Improvement (COSI) and its relationship to several other measures of benefit and satisfaction provided by hearing aids.

Several methods for measuring the self-reported benefit and satisfaction provided by a hearing aid were compared by administering all methods to each of 98 subjects. Significant correlations between many of the measures and reasonably high test-retest correlations for two of the measures administered twice suggest that most of the measures provide valid estimates of benefit and/or satisfaction. One of the methods included is a new tool called the Client Oriented Scale of Improvement (COSI). In this method, the client effectively writes the self-report questionnaire by nominating up to five listening situations in which help with hearing is required. At the conclusion of rehabilitation, reduction in disability and the resulting ability to communicate in these specific situations is quantified. Based on correlation analysis, the COSI method is as statistically valid as the much longer, more traditional questionnaires. Other features, such as relevance, diagnostic utility, compatibility with normal interviewing techniques, and good test-retest reliability, make it particularly suitable for routine clinical use.

Aged↗

Compression? Yes, but for low or high frequencies, for low or high intensities, and with what response times?

Several rationales for using compression in hearing aids are outlined. These rationales comprise discomfort avoidance, loudness normalization, noise reduction, short term signal dynamic range reduction, empirically determined compression, and long-term signal dynamic range reduction. The compression systems needed to implement each of these differ greatly, and these differences can be viewed as differences in the frequency range undergoing most compression, the intensity range undergoing most compression, and the speed at which the compressor(s) operate. A classification system along these lines is introduced and examples of currently available hearing aids falling into each category are given. The effects of each type of compression on speech intelligibility is investigated via a review of published research. The results of this indicate that, for speech in quiet at a comfortable level, no compression scheme yet tested offers better intelligibility than individually selected linear amplification. If input level is then decreased and the aid wearer is prevented from adjusting the volume control, many types of compression provide intelligibility superior to that available from linear amplification. In broadband noise, only one system, containing wideband compression followed by fast acting high-frequency compression, has so far been shown to provide significant intelligibility advantages.

Equipment Design↗

An equivalent input noise level criterion for hearing aids.

The purpose of this project was to establish a maximum acceptable equivalent input noise level (EINL) for hearing aids. It was found that, if the version of the National Acoustic Laboratories (NAL) procedure for selecting the gain and frequency response of hearing aids, which includes modifications for severe and profound hearing loss is used, the EINL criterion can be relaxed for higher gain hearing aids, as a function of the gain of the aid. The relationship between relaxation of the criterion and 2-cc coupler gain is nonlinear, in different amounts, at the various frequencies, so no simple rule can be used to describe the manner in which the criterion can be relaxed.

Auditory Perception↗

Gain, frequency response, and maximum output requirements for hearing aids.

This article applies the gain and frequency response and maximum output selection procedures currently recommended by the National Acoustic Laboratories (NAL) of Australia to the audiograms of a representative group of adult and child clients of Australian Hearing Services (AHS) to specify the performance that is required of various types of hearing aids in order to ensure that they can provide adequate gain, frequency response, and maximum output levels for at least 90% of the AHS client population. Cumulative frequency distributions of required 2-cc coupler gain slopes were calculated for each type of aid and used to design required frequency response variations. Coupler slope requirements in different octaves were found to be independent of one another. The required range of gain-maximum output combinations was determined for each type of aid.

Adult↗

Guidelines for fitting multiple memory hearing aids.

Fitting guidelines to determine candidacy for multiple memory hearing aids and the choice of amplification for each memory are devised by reviewing studies on the selection of amplification for different listening conditions. The guideline for determining candidacy comprises three factors: (1) difficulty hearing in acoustically diverse conditions, (2) an average high-frequency hearing loss greater than about 55 dB HL, and (3) ability to vary the low-frequency gain by at least 5 dB. People who meet all three criteria are highly likely to benefit from multiple memories. People who meet criteria 1 and 2 or 1 and 3 are possible candidates. The guideline for determining the amplification characteristics needed for each memory also enables the fitter to determine the number of memories needed. The following recommendations for amplification characteristic for various listening conditions are based on the literature review: linear amplification with the prescribed National Acoustic Laboratories' (NAL) frequency response is recommended for listening to speech in quiet; substantial high-frequency compression is recommended for ease of understanding two voices that differed by 10 dB in overall level; a linear response steeper than the NAL response is recommended for ease of understanding speech in a low-frequency background noise; low-frequency compression is recommended to reduce annoyance of low-frequency background noise; and a linear response flatter than the NAL response is recommended for listening in high-frequency background noise, and possibly for listening to music.

Equipment Design↗

The effect of a depleting anti-CD4 monoclonal antibody on T cells and fetal pig islet xenograft survival in various strains of mice.

The effect of a cell-depleting anti-CD4 monoclonal antibody (mAb), GK1.5, was studied in a number of strains of inbred mice. Young adult female NOD/Lt, CBA and BALB/c mice were transplanted with organ cultured fetal pig pancreas and given 0.3 mg of the mAb (as ascites) on days -1, 0 and +1. The grafts were mostly rejected within 13 days in CBA mice but BALB/c and NOD recipients still had essentially intact grafts with the NOD mice showing evidence of early rejection. By 28 days posttransplantation the BALB/c recipients still had well-preserved grafts with minimal infiltration, but NOD and CBA mice had generally rejected their grafts totally. Peritransplant mAb treatment reduced CD4+ T cells in the spleen and they showed only incomplete recovery by 28 days. To further analyse the effect of anti-CD4 treatment, these strains as well as C57BL/6 mice were given a single dose (0.3 mg) of GK1.5 either as ascites or as affinity purified mAb. There was no obvious difference in effect between the ascites and the purified mAb within a strain but the various strains showed consistent differences in their blood, spleen and lymph node lymphocytes and in their response to the mAb. C57BL/6 mice differed from the other strains in having fewer T cells but more B cells in the blood, spleen and lymph nodes and a low CD4/CD8 ratio. Recovery of CD4+ T cells was most rapid in NOD mice and this together with the relatively high number of these cells may account for the ability of these mice to reject grafts despite immunosuppression that can allow prolonged graft survival in other strains. This study emphasizes the need to examine various strains of mice when making general statements about the efficacy of immunosuppression in transplantation and stresses the need to be aware of the frequent use of 'permissive' strains in reports where excellent graft survival is reported.

Animals↗

Candidates for multiple frequency response characteristics.

This study examined what types of subjects may benefit from the use of multiple memory hearing aids that offer variation in their frequency response characteristics. Thirty subjects with varied degrees and configurations of hearing loss compared an individually prescribed frequency response (NAL) and two variations in which the real-ear response slope was either increased (more high-frequency emphasis) or decreased by about 3 dB/octave over the range from 500 Hz to 4000 Hz. The evaluations consisted of paired comparison judgments of pleasantness and of ease of understanding speech, in quiet and in three background noises with substantially different acoustic spectra (traffic noise, speech babble, and high-frequency noise). Twelve of the 30 subjects selected different frequency responses for different background noises and/or for different response criteria. These subjects were characterized as having the more severe high-frequency hearing losses (averaged across 2000, 3000, and 4000 Hz). They also tended to be those for whom the three frequency responses provided the greatest variation in real-ear low-frequency gain. (Despite substantial electronic variations, some subjects received only small variations in real-ear gain at the low frequencies). When subjects chose a different response for different conditions, they tended to prefer responses for which the slope was negatively related to the spectrum of the stimulus. This was true for both response criteria. The conclusion is that hearing aid users with substantial high-frequency losses, and who can be fitted with sufficient variation in the low-frequency real-ear gain, have the potential to benefit from having a choice of frequency response characteristics.

Adolescent↗

Hearing aid evaluation: predicting speech gain from insertion gain.

In this study, hearing aid gain for speech was defined as the difference in level between the aided and unaided performance-intensity functions measured at any specific value of percentage of items correct. The articulation index method was used to predict speech gain based on the subject's unaided sound field thresholds, ambient room noise, hearing aid internal noise, hearing aid insertion gain, and the subject's unaided performance-intensity function. Predicted speech gain agreed with measured speech gain with rms errors of only 3 dB for 11 subjects with mild or moderate hearing loss tested with monosyllabic words and continuous discourse. The speech gain provided by a hearing aid can thus be predicted from electroacoustic measures, which generally can be obtained in a shorter time. Importance functions believed to be applicable to nonsense syllables, words, and continuous discourse were used to make the predictions, but prediction accuracy was not affected by the importance function chosen. Speech gain measured with the monosyllabic word test was highly correlated with speech gain measured with the continuous discourse test, provided that similar presentation levels were used.

Aged↗

Cephalexin and penicillin in the treatment of group A beta-hemolytic streptococcal throat infections.

OBJECTIVE: To determine whether cephalexin or penicillin is more effective in the treatment of group A beta-hemolytic streptococcal tonsillopharyngitis in children. DESIGN: Randomized, double-blind, crossover study conducted from 1981 to 1984. SETTING: Seven pediatric practices in the United States, including private offices and pediatric clinics. PARTICIPANTS: Of the 654 patients, 525 children and adolescents with clinical evidence of tonsillitis or pharyngitis and throat cultures positive for group A beta-hemolytic streptococcal infection were evaluable. Eighty percent of patients completed the study; none were withdrawn because of adverse reaction. SELECTION CRITERIA: Children and adolescents who had acute illness suggestive of group A beta-hemolytic streptococcal infection were enrolled in the study. Treatment was continued if the throat culture was positive for group A beta-hemolytic streptococcal infection. INTERVENTIONS: Four doses of cephalexin and penicillin (27 mg/kg per day) were prescribed to be taken on an empty stomach for 10 days. MEASUREMENTS/MAIN RESULTS: Symptomatic clinical failure occurred in 8% of penicillin-treated patients and in 3% of cephalexin-treated patients. Bacteriologic failure rates were 11% in the penicillin treatment group and 7% in the cephalexin treatment group. The combined treatment failure rate of clinical relapse plus asymptomatic bacteriologic failure was 19% in the penicillin treatment group and 10% in the cephalexin treatment group. Paired antistreptolysin-O titer increased significantly in 62.3% of penicillin-treated patients and in 64.2% of cephalexin-treated patients. Similarly, anti-DNase B titers rose 52.2% in penicillin-treated patients and 52.4% in cephalexin-treated patients. CONCLUSION: Cephalexin is a more effective drug than penicillin in the treatment of group A beta-hemolytic streptococcal throat infection in children.

Adolescent↗

Allowing for real ear venting effects when selecting the coupler gain of hearing aids.

Vents in hearing aids have two major effects on the insertion gain of a hearing aid: they let low-frequency sound in without amplification, and they reduce the low-frequency gain of sound transmitted through the hearing aid. Their net effect on low-frequency gain can thus be either negative or positive. This paper shows how to allow for both of these effects. One of the results is that for many hearing-impaired clients, there is a range of coupler gain curves which will result in the required insertion gain. The tables in this article are arranged to enable the user to specify a desired vent, and then determine the allowable range of coupler gains that will achieve a desired insertion gain to within a specified tolerance. The results of various studies comparing coupler gain and insertion gain are also compared and combined. The calculation method outlined in this paper can predict low-frequency real ear insertion gain for the individual subject with a prediction accuracy (root-mean-square-error) of 3.6 dB.

Ear↗

Accuracy of twelve methods for estimating the real ear gain of hearing aids.

The gain of a hearing aid was measured on each of eight subjects using a variety of functional (subjective) and insertion (objective) gain methods. Each measurement was repeated on subsequent days and the hearing aid gain was also determined in several couplers and on KEMAR. The multiple measurements enabled an accurate estimate of the "true" gain of the aid on each subject to be determined. The real ear gain measured by each of the individual methods was then compared with this true gain estimate and the relative accuracy of each method was quantified. Of the clinically feasible methods, probe microphone measurement of insertion gain proved to be the most accurate. Few significant differences were found between functional gain and insertion gain. Estimation of real ear gain on the basis of coupler gain appeared to be a reasonable, though not recommended approach.

Audiometry↗

The National Acoustic Laboratories' (NAL) new procedure for selecting the gain and frequency response of a hearing aid.

A new procedure is presented for selecting the gain and frequency response of a hearing aid from pure-tone thresholds. This was developed from research which showed that a previous procedure did not meet its aim of amplifying all frequency bands of speech to equal loudness but that frequency responses which did so were considerably more effective. Measurements of 30 sensorineurally hearing-impaired ears (27 subjects), together with data from other studies, were analyzed to determine the best formula for predicting the optimal frequency response, for each individual, from the audiogram. The analysis indicated that a flat audiogram would require a rising frequency response characteristic of about 8 dB/octave up to 1.25 kHz and thereafter a falling characteristic of about 2 dB/octave. Variations in audiogram slope required about one-third as much variation in response slope. Three frequency average (3FA) gain was calculated to equal the 3FA gain of the previous procedure. Forty-four subjects (67 aided ears) fitted by the new procedure were evaluated by paired comparison judgments of the intelligibility and pleasantness of speech. The prescribed frequency response was seldom inferior to, and usually better than, any of several variations having more, or less, low and/or high-frequency amplification. On the average, used gain was approximately equal to prescribed gain. It is concluded that the new formula should prescribe a near optimal frequency response with few exceptions.

Audiometry, Pure-Tone↗

Updated performance requirements for hearing aids.

This article updates the design specifications for a family of hearing aids required by the National Acoustic Laboratories (NAL) in order to meet the needs of its clients. The required range of coupler gains and frequency responses of behind-the-ear (BTE), in-the-ear (ITE) and body-level (BL) hearing aids has been recalculated on the assumption that the aids will be fitted using the new Byrne-Dillon procedure for selecting gain and frequency response. In the light of recently acquired data, the specification of maximum allowable internal noise has been changed slightly and no relaxation of the equivalent input noise criterion for high gain aids is allowed. Since the Byrne-Dillon procedure demands a somewhat smaller (though still quite substantial) range of hearing aid response shapes, the subdivision of the total response requirements has also been repeated. The number of hearing aid models specified is still 18, but the number of fitter-adjusted controls has been reduced from 6 to 4. The fitter-adjusted controls comprise a maximum power output (MPO) level control, an MPO shape control, a low-tone cut control and a high-tone cut control, with MPO control being achieved by means of low-distortion compression limiting.

Australia↗

Performance requirements for hearing aids.

The requirements for hearing aid frequency responses, SSPL characteristics, compression limiting, directional response, and internal noise are examined. On the basis of the assumptions made, aids would best serve the hearing impaired if they had flat very-low-frequency gains (and various mid- and high-frequency gains), SSPL responses adjustable in shape and level, directional responses, and internal noise levels below a recommended criterion level.

Aged↗