PubMed Health⌕ Search

Biomedical subjects

H Dillon

Publications and source records attributed to H Dillon.

At least 19 recordsLinked to original sources

Electrophysiological and behavioral evidence of auditory processing deficits in children with reading disorder.

OBJECTIVE: The aim of the research was to investigate auditory processing abilities in children with reading disorders using electrophysiological and behavioral tasks. METHODS: Differences in auditory processing between control, compensated (age appropriate reading skills with a history of reading disorder), and reading disordered groups were systematically investigated. RESULTS: The reading disorder group had significantly lower results than control and compensated reader groups for most tests in the reading and auditory processing test battery. All children with a reading disorder did not pass at least one behavioral test of auditory processing, and hence would be diagnosed clinically as having an auditory processing disorder (APD). The reading disorder group also had significantly smaller /ga/-evoked mismatch negativity (MMN) area than the control group. Compensated and control groups had similar results for the electrophysiological and behavioral auditory processing tests. Correlation analyses showed that reading fluency and accuracy and nonword scores (measured using Castle and Coltheart's word/nonword test) correlated significantly with most APD measures. CONCLUSIONS: The general profile of auditory processing deficits in children with reading disorder was a combination of deficits on frequency patterns (i.e. frequency pattern test) and absent or small /ga/-evoked MMN. Significant results from the correlation analyses support the co-morbidity of reading and auditory processing disorders. SIGNIFICANCE: Children with reading disorders are likely to have auditory processing disorders.

Acoustic Stimulation↗

Circumferential mural bands in the small intestine causing simple obstructive colic: a case series.

REASONS FOR PERFORMING STUDY: Circumferential mural band (CMB) in the small intestine is an emerging condition in Ireland. The clinical presentation is a simple obstruction of the small intestine of unknown aetiology. HYPOTHESIS: Horses affected with CMB in the small intestine have a good prognosis following surgical decompression into the caecum. METHODS: A retrospective study was carried out and 28 cases identified from 559 colic surgeries performed over a 5.5 year period. An exploratory celiotomy was performed in every case. A simple obstruction at the mid or distal jejunum was identified caused by a CMB, which was multiple in some cases. All of the horses except 2 had undergone a regular anthelmintic programme. RESULTS: Manual decompression of the small intestine into the caecum resulted in resolution of the simple jejunal obstruction. A constricted segment of small intestine was resected in one case, as the degree of constriction was severe. A full thickness biopsy was taken from another case. Histopathology was performed on both samples. All horses recovered from surgery and were discharged from the hospital 7-32 days post operatively. Short-term complications were observed. Survival rate was 100% at long-term follow-up. Histopathology showed inflammatory infiltration in the submucosa, muscularis and serosa with eosinophils predominating. Parasites were not detected. CONCLUSION AND POTENTIAL RELEVANCE: Small intestine circumferential mural bands have a good prognosis after surgical decompression of the small intestine into the caecum.

Animals↗

Factors affecting the use and perceived benefit of ITE and BTE hearing aids.

The aim of the present study was to investigate factors that might affect hearing aid use, satisfaction and perceived benefit. A further aim was to look at which variables affect the choice of hearing aid, in particular, an in-the-ear (ITE) versus a behind-the-ear (BTE) device. Twenty-nine elderly hearing-impaired people with a mild-to-moderate hearing loss were fitted with both an ITE and a BTE hearing aid with similar electroacoustic performance. Both hearing aids were linear with output compression limiting and were fitted in a randomized order. After wearing each device for a six-week period, subj ets were asked to select the hearing aid they preferred. Variables significantly related to hearing aid choice, use and perceived benefit included ease of management, accuracy with which the NAL-R insertion gain target was achieved, earmould comfort and the type of hearing aid the client preferred initially.

Aged↗

Children's amplification needs--same or different from adults?

Hearing aid fitting strategies for children have largely developed separately from those for adults. There has, however, been little consideration of whether children's amplification requirements are different, except for the physical effects of differences in ear canal size. This paper summarizes the fitting strategies for children, and examines whether children require more (or less) gain for high-, medium- or low-level sounds, or a different frequency response, compared with adults with similar hearing loss. Research relating to the above questions is reviewed. The gain that children require for high-level sounds is not different than for adults because loudness discomfort levels are similar. The gain children prefer for medium-level sounds is the same, or only slightly more, than is preferred by adults. Children may require greater gain for low-level sounds because they do require higher signal levels to achieve the same level of speech understanding as adults do. There are, however, arguments why more gain for low-level sounds may not be desirable. The frequency response children prefer is the same as that preferred by adults. New methods for evaluating individual fittings are briefly discussed.

Adolescent↗

Fitting low ratio compression to people with severe and profound hearing losses.

OBJECTIVE: In this study, we aimed to determine the extent to which wide dynamic range compression and compression limiting could benefit severely and profoundly hearing-impaired adults. DESIGN: Subjects were fitted with multi-memory hearing aids incorporating frequency independent input-controlled compression with a 2:1 compression ratio and output-controlled compression limiting. The input compression threshold (CT) was varied to establish the lowest level that maintained audibility for conversational intensity speech without acoustic feedback oscillation. Where a low (40 to 57 dB SPL) CT was possible, this was compared with a moderate (65 to 74 dB SPL) level. The preferred input compression setting was subsequently compared with linear, compression-limited amplification in the same aids. In the three cases where 2:1 input compression could not be used, because of feedback or loudness insufficiency problems, compression limiting was compared with peak clipping. Field trials were conducted over a 2- or 3-mo period to establish preferences. RESULTS: Nine of the 16 subjects preferred the inclusion of the higher level input compression, and one preferred lower level input compression. Four subjects preferred linear, compression-limited amplification, one favored peak clipping, and one could not be satisfied with any of the options provided. CONCLUSIONS: 2:1 input compression was useful, and preferred by 10 of the subjects, but for nine subjects the preferred CT was relatively high. With a group 4-frequency average loss of 87 dB HTL, the results demonstrate that fast-acting, low compression ratio systems can be useful for losses traditionally regarded as the domain of linear amplification.

Adult↗

Maximizing effective audibility in hearing aid fitting.

OBJECTIVE: This paper examines why more audibility is not always better than less audibility if hearing-impaired people are to best understand speech. DESIGN: We used speech perception data from 14 normally hearing and 40 hearing-impaired people to quantify the contribution of audibility to speech intelligibility. The quantification revealed that the effectiveness of audibility decreased with hearing loss, and the decrement was greater at high frequencies than at lower frequencies. To apply the Speech Intelligibility Index (SII) model to predict speech intelligibility for hearing-impaired people, we modified the model to take account of effective audibility rather than physical audibility. RESULTS: The modified SII model provided an adequate description of speech performance of people with a wide range of hearing threshold levels. We applied the model to the evaluation of two prescriptions for a sloping audiogram at prescribed levels and at equated loudness levels to demonstrate the necessity of considering loudness and effective audibility in prescribing amplification. Effective audibility is defined as audibility corrected for the effects of level distortion and hearing loss desensitization, and this paper proposes a method of estimating effective audibility from hearing threshold level at different frequencies. CONCLUSIONS: The practical implication of considering effective audibility in prescribing hearing aids is that for a given listening level, less gain is provided at frequencies where the hearing is most impaired to allow more gain at frequencies where audibility is most useful. In developing the NAL-NL1 prescription for nonlinear hearing aids, we adopted the modified SII model together with a loudness model to derive optimal gain-frequency response characteristics that maximize predicted speech intelligibility for people with different degrees of hearing losses.

Audiometry, Speech↗

Should children who use cochlear implants wear hearing aids in the opposite ear?

OBJECTIVE: The aim of this study was to investigate 1) whether a hearing aid needs to be adjusted differently depending on whether a child wears a cochlear implant or another hearing aid in the contralateral ear; 2) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural interference; and 3) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural benefits in speech perception, localization, and communicative functioning in real life. DESIGN: Sixteen children participated in this study. All children used a Nucleus 22 or Nucleus 24 cochlear implant system programmed with the SPEAK strategy in one ear. The hearing aid amplification requirements in the nonimplanted ear of these children were determined using two procedures. A paired comparison technique was used to identify the frequency response that was best for speech intelligibility in quiet, and a loudness balancing technique was used to match the loudness of speech in the ear with a hearing aid to that with a cochlear implant. Eleven of the 16 children participated in the investigation of binaural effects. Performance in speech perception, localization, and communicative functioning was assessed under four aided conditions: cochlear implant with hearing aid as worn, cochlear implant alone, hearing aid alone, and cochlear implant with hearing aid adjusted according to individual requirements. RESULTS: Fifteen of the 16 children whose amplification requirements were determined preferred a hearing aid frequency response that was within +/-6 dB/octave of the NAL-RP prescription. On average, the children required 6 dB more gain than prescribed to balance the loudness of the implanted ear for a speech signal presented at 65 dB SPL. For all 11 children whose performance was evaluated for investigating binaural effects, there was no indication of significantly poorer performance under bilaterally aided conditions compared with unilaterally aided conditions. On average, there were significant benefits in speech perception, localization, and aural/oral function when the children used cochlear implants with adjusted hearing aids than when they used cochlear implants alone. All individuals showed benefits in at least one of the measures. CONCLUSIONS: Hearing aids for children who also use cochlear implants can be selected using the NAL-RP prescription. Adjustment of hearing aid gain to match loudness in the implanted ear can facilitate integration of signals from both ears, leading to better speech perception. Given that there are binaural advantages from using cochlear implants with hearing aids in opposite ears, clinicians should advise parents and other professionals about these potential advantages, and facilitate bilateral amplification by adjusting hearing aids after stable cochlear implant MAPs are established.

Adolescent↗

NAL-NL1 procedure for fitting nonlinear hearing aids: characteristics and comparisons with other procedures.

A new procedure for fitting nonlinear hearing aids (National Acoustic Laboratories' nonlinear fitting procedure, version 1 [NAL-NL1]) is described. The rationale is to maximize speech intelligibility while constraining loudness to be normal or less. Speech intelligibility is predicted by the Speech Intelligibility Index (SII), which has been modified to account for the reduction in performance associated with increasing degrees of hearing loss, especially at high frequencies. Prescriptions are compared for the NAL-NL1, desired sensation level [input/output], FIG6, and a threshold version of the Independent Hearing Aid Fitting Forum procedures. For an average speech input level, the NAL-NL1 prescriptions are very similar to those of the well-established NAL-Revised, Profound procedure. Compared with the other procedures, NAL-NL1 prescribes less low-frequency gain for flat and upward sloping audiograms. It prescribes less high-frequency gain for steeply sloping high-frequency hearing losses. NAL-NL1 tends to prescribe less compression than the other procedures. All procedures differ considerably from one another for some audiograms.

Acoustic Stimulation↗

Estimating the location of probe microphones relative to the tympanic membrane.

This experiment investigated the accuracy with which the location of a probe tip relative to the tympanic membrane can be estimated by means of standing waves. The ear canal length of each ear of six adult subjects was measured with a probe tube using a tactile method. A 6-kHz warble tone was then generated, and the position of the standing wave notch in the ear canal was determined using a probe microphone by noting the place where the sound pressure level was at a minimum. The distance of the notch from the tympanic membrane was then calculated. The mean distance of the notch from the tympanic membrane was found to be 14.1 mm. It was concluded that this technique is reliable and suitable for clinical use when it is important that the probe tube be placed within a known distance of the eardrum for accurate measurement of real-ear aided gain.

Acoustic Stimulation↗

Incentives and obstacles to the routine use of outcomes measures by clinicians.

OBJECTIVE: Unless clinicians are forced by funds providers to use outcomes measures, clinicians will choose to use them only if the value they provide is commensurate with the administration time required. This study was designed to determine which aspects of outcomes measures encouraged clinicians to use them and which aspects discouraged clinicians from using them. DESIGN: Clinicians who had used one or more outcomes measures were surveyed using a reasonably open-ended survey. Comments were analyzed by categorising them and counting the number of comments within each category. RESULTS: Aspects that were most valued included determining the clients' goals and expectations at the outset of the rehabilitation program, as well as measures of improvement and of residual hearing difficulties at the end of the program. Aspects that most discouraged the use of outcomes measures included collection or recording of information that the clinician would prefer to collect and record in other ways, and an excessive amount of time to administer. CONCLUSION: To maximize the adoption of outcomes measures by clinicians, the tools should provide information in addition to a simple quantification of benefit. For example, this might comprise information about clients' initial goals and/or expectations.

Attitude↗

Optimal outcome measures, research priorities, and international cooperation.

The participants in the Eriksholm Workshop on "Measuring Outcomes in Audiological Rehabilitation Using Hearing Aids" debated three issues that are reported in this article. First, it was agreed that the characteristics of an optimal outcome measure vary as a function of the purpose of the measurement. Potential characteristics of outcome self-report tools for four common goals of outcome measurement are briefly presented to illustrate this point. Second, 10 important research priorities in outcome measurement were identified and ranked. They are presented with brief discussion of the top five. Third, the concept of generating a brief universally applicable outcome measure was endorsed. This brief data set is intended to supplement existing outcome measures and to promote data combination and comparison across different social, cultural, and health-care delivery systems. A set of seven core items is proposed for further study.

Correction of Hearing Impairment↗

Relative loudness perception of low and high frequency sounds in the open and occluded ear.

A comparison of published equal loudness contours indicates that different shapes are obtained at a comfortable level when the measurements are done in an occluded ear than when they are done in an open ear, even though all measurements are expressed as dB SPL at the eardrum. This paper presents the result from a loudness balancing test which confirms this observation. Eleven normal-hearing listeners balanced the level of a 500- and a 3000-Hz octave band babble-noise to the level of a 1500-Hz octave band babble-noise. The balancing test was completed in open and occluded ears using a loudspeaker and a hearing aid receiver, respectively. A probe tube microphone was used to measure the actual levels presented near the individual's eardrum. The results show that an average of 10 dB higher level was selected for the 500-Hz octave band when listening with the occluded ear than when listening with the open ear. A large range of factors is discussed, but no physical explanation for the discrepancy was found. The findings could have consequences for psychoacoustic experiments and for the use of loudness measurements for hearing aid prescription.

Auditory Threshold↗

An efficient, adaptive method of measuring loudness growth functions.

This paper presents a new categorical loudness scaling procedure that differs from previously published loudness scaling procedures by (i) adaptively selecting a new set of levels for each new sequence, (ii) deriving levels that are equispaced on the loudness scale, and (iii) using a continuous scale with few labels. A major advantage of the adaptive procedure is that the individual dynamic range need not be measured prior to loudness testing. The adaptive procedure proved to be time efficient and to produce complete loudness functions from Not heard to Uncomfortably loud for normal hearing and hearing impaired subjects. The pattern of short-term and long-term reliability was similar to that reported for non-adaptive loudness scaling procedures. Three presentations produced a stable loudness function. Normative curves for one octave babble-noise at six test frequencies are presented and compared to normative data obtained with a selection of published categorical scaling procedures.

Adolescent↗

Control of hearing-aid saturated sound pressure level by frequency-shaped output compression limiting.

To fit a hearing aid successfully, it is important to set the Saturated Sound Pressure Level (SSPL) or Maximum Power Output (MPO) appropriately. The SSPL should be low enough to prevent sounds from being amplified to uncomfortable loudness, and yet high enough to maximize speech intelligibility and signal quality. To help attain an optimum SSPL setting, a novel output compression limiting scheme, with shapable MPO (ShaMPO), has been devised. In ShaMPO, the SSPL is shaped across frequencies in accordance with the individual user's loudness discomfort levels (LDLs). The contributions of different frequency regions to loudness are controlled by summing the amplified signal power relative to the LDLs across frequencies, and using this signal to control a wideband compressor. This scheme and a conventional output compression limiting (AGCo) scheme have been implemented in a digital hearing aid. Ten subjects, with moderately-severe to profound sensorineural hearing losses, participated in a study comparing speech intelligibility and listening comfort for the two schemes. Results showed that there were no significant differences in the speech perception scores between AGCo and ShaMPO, even when the speech was presented at 80 dBA, at which level both schemes were in compression much of the time. However, an examination of how subjects selected the SSPL for the two schemes revealed that, in many instances, AGCo would permit some sounds with compact spectra to be amplified above LDL, whereas ShaMPO would not. Thus the ShaMPO scheme can improve listening comfort for some intense sounds without a loss of speech intelligibility. In contrast, half the subjects found speech at 80 dBA to be uncomfortably loud when listening through their own aids.

Aged↗

Client preferences for compression threshold in single-channel wide dynamic range compression hearing aids.

OBJECTIVE: Compression in hearing aids can be applied with low compression ratios over a wide range of input levels, but reverts to linear amplification below the compression threshold (CT). In this study, we aimed to determine which of two CTs was preferred by subjects as they used their hearing aids in their own environments, and whether they would prefer to have no low ratio compression at all. DESIGN: Subjects were fitted with a multimemory hearing aid incorporating input controlled compression with a 2:1 compression ratio and output controlled compression limiting. The two memories contained identical programs except that they differed in CT. Sixteen mild to moderately sensorineurally hearing-impaired subjects compared low (approximately 40 dB SPL) and moderate (approximately 65 dB SPL) CTs over 2 mo of field trials using hand held remote controls to switch between the alternatives. In a third month's trial, the preferred option (which also included output controlled compression limiting) was compared with compression limiting alone. RESULTS: The higher CT was preferred by 14 of the subjects. The combination of input compression and output compression limiting was preferred to compression limiting alone by 14 of the subjects. CONCLUSIONS: Several real world advantages of frequency independent 2:1 compression with a CT of about 65 dB SPL were demonstrated over linear amplification. Extending the compression to much lower input levels appears to carry more disadvantages than advantages, at least for clients with mild and moderate hearing losses, when fitted with single-channel compression aids with a 2:1 compression ratio.

Aged↗

The National Acoustic Laboratories' procedure for selecting the saturation sound pressure level of hearing aids: theoretical derivation.

This paper presents the derivation of a procedure for prescribing the saturation sound pressure level (SSPL) of hearing aids. The procedure is designed to be used with either measured values of loudness discomfort level (LDL) or with hearing threshold values alone. SSPL needs to be low enough to prevent the hearing aid from causing loudness discomfort to the aid wearer but high enough to prevent the hearing aid from being excessively saturated by speech. The maximum SSPL likely to be acceptable can be predicted by measuring LDL or by estimating LDL from hearing thresholds. The minimum SSPL likely to be acceptable can be predicted by calculating, for any particular hearing loss, the amount of gain likely to be needed and hence the SSPL needed if the speech input signal is continuous discourse at an overall level of 75 dB SPL. The midpoint between the minimum and maximum acceptable SSPL values is defined as the optimal or prescribed SSPL, and the three frequency average (3FA; 500, 1000, and 2000 Hz) value of this can be predicted from the 3FA hearing thresholds. Alternatively, the SSPL prescription at each frequency can be prescribed on the basis of the hearing aid gain at each frequency. For either method, the SSPL prescription needs to be increased for people with a conductive component to their hearing losses. The SSPL prescription, when referred to a 2-cc coupler, needs to be decreased for infants, for deeply inserted hearing aids, for multichannel hearing aids that limit SSPL separately in each band, and possibly for nonlinear hearing aids. The 3FA SSPL prescribed for persons with a sensorineural hearing loss increases linearly from 89 dB SPL for normal hearing to 107 dB SPL for a person with a 60 dB HL 3FA loss, and then linearly again to 139 dB SPL for a person with a 120 dB HL 3FA loss. The procedure predicts that the acceptable range of SSPLs is very wide for people with mild losses but is vanishingly small for people with profound losses.

Adult↗

The National Acoustic Laboratories' procedure for selecting the saturation sound pressure level of hearing aids: experimental validation.

OBJECTIVE: The primary aim of this study is to evaluate the accuracy of a new procedure for selecting the saturation sound pressure level (SSPL) of hearing aids. Secondary aims are to investigate what limits the minimum SSPL that is acceptable to clients and whether the type of limiting (peak clipping or compression limiting) affects the SSPL required. DESIGN: The study comprised two experiments. In the first, subjects increased the SSPL of a laboratory master hearing aid until they experienced loudness discomfort and decreased it until the sound became less acceptable in some way. In the second study, subjects wore multi-memory programmable hearing aids in their own environments and reported which of the two programs, differing only in SSPL setting, provided the more acceptable sound quality and comfort. RESULTS: The theoretical procedure being investigated prescribed SSPLs that were within the acceptable range for 86% of the subjects in the laboratory study and for 63% of the subjects in the field experiment. On average, the theoretical predictions were neither too high nor too low. Incorporating individual measurements of loudness discomfort level into the prescription formula increased accuracy by such a small amount that it was not considered worthwhile. For a compression limiting hearing aid, the first thing that subjects noticed as SSPL was reduced was inadequate loudness. For the peak clipping hearing aid, however, both inadequate loudness and perception of distortion limited the acceptable SSPL range. CONCLUSION: The theoretical procedure provides a good initial prescription of three frequency average SSPL, but it is still essential to evaluate the fitting and, if necessary, fine tune the individual's hearing aid. Compression limiting hearing aids can have slightly lower SSPL settings than peak clipping hearing aids for the same acceptability.

Acoustic Stimulation↗

Speech recognition of hearing-impaired listeners: predictions from audibility and the limited role of high-frequency amplification.

Two experiments were conducted to examine the relationship between audibility and speech recognition for individuals with sensorineural hearing losses ranging from mild to profound degrees. Speech scores measured using filtered sentences were compared to predictions based on the Speech Intelligibility Index (SII). The SII greatly overpredicted performance at high sensation levels, and for many listeners, it underpredicted performance at low sensation levels. To improve predictive accuracy, the SII needed to be modified. Scaling the index by a multiplicative proficiency factor was found to be inappropriate, and alternative modifications were explored. The data were best fitted using a method that combined the standard level distortion factor (which accounted for decrease in speech intelligibility at high presentation levels based on measurements of normal-hearing people) with individual frequency-dependent proficiency. This method was evaluated using broadband sentences and nonsense syllables tests. Results indicate that audibility cannot adequately explain speech recognition of many hearing-impaired listeners. Considerable variations from audibility-based predictions remained, especially for people with severe losses listening at high sensation levels. The data suggest that, contrary to the basis of the SII, information contained in each frequency band is not strictly additive. The data also suggest that for people with severe or profound losses at the high frequencies, amplification should only achieve a low or zero sensation level at this region, contrary to the implications of the unmodified SII.

Adult↗