Safety and efficacy of internal cardioversion of atrial fibrillation in patients with impaired left ventricular systolic function.

In patients with structural heart disease and left ventricular ejection fraction <40%, internal cardioversion is a safe and effective method for converting persistent atrial fibrillation. The acute success rate and atrial defibrillation requirement for cardioversion in these patients is comparable to patients with lone atrial fibrillation and structurally normal hearts.

Aged↗

Experience with a single-pass, dual-electrode implantable atrial defibrillator lead for maintaining sinus rhythm in patients with recurrent atrial fibrillation.

The implantable atrial defibrillator is a new potential nonpharmacologic treatment for recurrent atrial fibrillation. The results of this study suggest that a simplified lead configuration, with a single-pass, dual-electrode atrial defibrillation lead can be used for both atrial fibrillation detection and defibrillation with an implantable atrial defibrillator.

Adult↗

Effect of electrode polarity on the energy required for transthoracic atrial defibrillation.

Two hundred patients with atrial fibrillation underwent transthoracic cardioversion using adhesive electrodes positioned at the apex and right infraclavicular area, and the apex electrode was randomly selected to serve as the cathode or anode. The mean defibrillation energy requirement with the cathodal configuration was significantly lower than with the anodal configuration.

Adolescent↗

Atrial fibrillation detection and R-wave synchronization by Metrix implantable atrial defibrillator: implications for long-term efficacy and safety. The Metrix Investigators.

BACKGROUND: The long-term efficacy of atrial fibrillation (AF) detection and R-wave synchronization are critical safety requirements for the development of an implantable atrial defibrillator (IAD) for treatment of AF. METHODS AND RESULTS: The long-term efficacy of the Metrix IAD for AF detection and R-wave synchronization was tested in 51 patients. The mean duration of follow-up was 259+/-138 days (72 to 613 days). AF detection tests were performed 2240 times during observed operation with 100% specificity and 92.3% sensitivity for differentiation between sinus rhythm and AF; 2219 episodes and their electrograms stored in the device during AF detection were analyzed. The positive predictive value of the AF detection algorithm was 97.4% (lower 95% confidence limit [CL], 94.5%) in the out-of-hospital setting. A total of 242 435 R waves were analyzed for R-wave synchronization. Of these, 49% were marked for synchronized shock delivery, 82% of sinus rhythm and 36% of AF R waves, respectively. All shock markers were properly synchronized and within the R wave (overall synchronization accuracy, 100%; lower 95% CL, 99.999%). Overall, 3719 shocks have been delivered via the IAD with no instance of unsynchronized shock delivery or any episode of proarrhythmia. The observed proarrhythmic risk was 0%, with an estimated maximum proarrhythmic risk of 0.084% per shock (95% upper CL). CONCLUSIONS: The Metrix IAD can appropriately detect AF with a high specificity and sensitivity and reliably synchronize within a suitable R wave for shock delivery to minimize the risk of ventricular proarrhythmia.

Aged↗

Long-term outcome in patients with chronic atrial fibrillation after successful internal cardioversion.

Internal cardioversion is safe and effective in restoring sinus rhythm, even in patients with persistent AF of prolonged duration. Up to 40% to 50% of patients with AF lasting >1 year but <3 years could be maintained in sinus rhythm using a class III antiarrhythmic drug after successful internal cardioversion, and amiodarone appears to be more effective than sotalol in this patient population.

Aged↗

Transvenous atrial defibrillation--techniques and clinical applications.

Atrial fibrillation (AF) is the most common arrhythmia requiring treatment. The most desirable therapy may be restoration and maintenance of sinus rhythm. Limitations of the current methods for cardioversion of AF have prompted the development of transvenous atrial defibrillation (TADF) as an alternative and more effective technique for converting AF. Recent advances in the technique of TADF, particularly in the design and configuration of the electrodes, and the use of an optimal biphasic shock waveform have dramatically improved the efficacy of TADF for the termination of all types of AF. The reduction in voltage and energy requirements for cardioversion by TADF may allow the procedure to be performed with little or no sedation and the risk of general anesthesia may be avoided. Both experimental and clinical studies have demonstrated the feasibility, safety, and efficacy of using TADF as a new temporary or "permanent" mode of electrical therapy for AF. It has several potential applications, from acute termination of AF in the electrophysiology laboratory and in patients who have failed to respond to external cardioversion, to its use as an implantable device for treating recurrent AF. This article reviews the current technique and clinical applications of TADF for treatment of AF.

Animals↗

Defibrillation-guided radiofrequency ablation of atrial fibrillation secondary to an atrial focus.

OBJECTIVES: Our aim was to evaluate a potential focal source of atrial fibrillation (AF) by unmasking spontaneous early reinitiation of AF after transvenous atrial defibrillation (TADF), and to describe a method of using repeated TADF to map and ablate the focus. BACKGROUND: Atrial fibrillation may develop secondary to a rapidly discharging atrial focus that the atria cannot follow synchronously, with suppression of the focus once AF establishes. Focus mapping and radiofrequency (RF) ablation may be curative but is limited if the patient is in AF or if the focus is quiescent. Early reinitiation of AF has been observed following defibrillation, which might have a focal mechanism. METHODS: We performed TADF in patients with drug-refractory lone AF using electrodes in the right atrium (RA) and the coronary sinus. When reproducible early reinitiation of AF within 2 min after TADF was observed that exhibited a potential focal mechanism, both mapping and RF ablation were performed to suppress AF reinitiation. Clinical and ambulatory ECG monitoring was used to assess AF recurrence. RESULTS: A total of 44 lone AF patients (40 men, 4 women; 32 persistent, 12 paroxysmal AF) with a mean age of 58+/-13 years underwent TADF. Sixteen patients had early reinitiation of AF after TADF, nine (20%; 5 paroxysmal) exhibited a pattern of focal reinitiation. Earliest atrial activation was mapped to the right superior (n = 4) and the left superior (n = 3) pulmonary vein, just inside the orifice, in the seven patients who underwent further study. At the onset of AF reinitiation, the site of earliest activation was 86+/-38 ms ahead of the RA reference electrogram. The atrial activities from this site were fragmented and exhibited progressive cycle-length shortening with decremental conduction to the rest of the atrium until AF reinitiated. Radiofrequency ablation at the earliest activation site resulted in suppression of AF reinitiation despite pace-inducibility. Improved clinical outcome was observed over 8+/-4 months' follow-up. CONCLUSIONS: Transvenous atrial defibrillation can help to unmask, map, and ablate a potential atrial focus in patients with paroxysmal and persistent AF. A consistent atrial focus is the cause of early reinitiation of AF in 20% of patients with lone AF, and these patients may benefit from this technique.

Atrial Fibrillation↗

Implantable atrial defibrillator with a single-pass dual-electrode lead.

OBJECTIVES: We examined the feasibility and efficacy of using a single-pass, dual-electrode (Solo) lead for atrial fibrillation (AF) detection and defibrillation. BACKGROUND: The efficacy and safety of an implantable atrial defibrillator (IAD) has been extensively studied; however, separate right atrial (RA) and coronary sinus (CS) defibrillation leads are used for the present system. METHODS: We studied the use of the Solo lead for AF detection and defibrillation in 17 patients who underwent cardioversion of chronic AF. The Solo lead with a proximal 6-cm RA electrode and a distal 6-cm spiral-shaped CS electrode were positioned into the CS with the RA electrode against the anterolateral RA wall. The RA-CS electrogram signal amplitudes were measured and the efficacy of the Solo lead for AF detection and defibrillation was assessed by using an external version of the IAD. RESULTS: The leads were inserted in all patients without complication (mean fluoroscopy time: 13.3+/-6.8 min). The mean RA-CS signal amplitude was 484+/-229 microV during sinus rhythm and 274+/-88 microV during AF (p < 0.05). All patients had satisfactory atrial signal amplitude to allow accurate detection of sinus rhythm. Successful cardioversion was achieved in 16/17 (94%) patients with an atrial defibrillation threshold of 320+/-70 V (5.5+/-2.7 J). Insufficient interelectrode spacing resulted in suboptimal electrode locations, associated with a lower atrial signal amplitude, a higher atrial defibrillation threshold and diaphragmatic stimulation. CONCLUSIONS: These results suggest a simplified lead configuration with optimal interelectrode spacing can be used with an IAD for AF detection and defibrillation.

Adult↗

Improved efficacy of mode switching during atrial fibrillation using automatic atrial sensitivity adjustment.

Automatic mode switching (AMS) during atrial fibrillation (AF) in a dual chamber pacemaker is dependent on the accurate detection of an atrial electrogram. As atrial amplitude is often reduced during AF compared with sinus rhythm, this may result in failure of the AMS and a rapid ventricular response. In addition, undersensing of AF may result in competitive atrial pacing that sustains AF. We hypothesize that the use of automatic atrial sensitivity adjustment (ASA) may enhance AF sensing in a dual chamber pacemaker. We studied the AMS response with and without ASA of the Marathon DDDR (model 294-09, Intermedics, Inc.) pacemaker in 10 patients with paroxysmal AF. Intracardiac atrial electrograms during sinus rhythm and induced AF were recorded onto an analog tape recorder. They were replayed into the pacemaker to assess the AMS response at various starting atrial sensitivities from 3.5 to 0.8 mV with ASA activated and without. Atrial amplitude was reduced during AF. The higher the initial atrial sensitivity, the better is the AMS response and the lower the incidence of AF undersensing. The percentage of AMS before ASA ranged from 2.1% at an atrial sensitivity 3.5 mV to 95.6% at highest sensitivity of 0.5 mV (P < 0.05). After 10 minutes of ASA, the AMS response was improved from 1.7% to 50.6% and from 9.5% to 50.9% at starting atrial sensitivities of 3.5 mV and 2.5 mV, respectively (P < 0.05 in both instances). Undersensing during AF was also significantly reduced after ASA from 70% to 10% at a sensitivity of 3.5 mV and from 33.8% to 10.8% at 2.5 mV. There was no increase in oversensing. In four patients with paroxysmal AF with an implanted pacemaker, ASA improved AMS response in patients with a low implant atrial amplitude. In conclusion, efficacy of mode switching and AF sensing are dependent on the programmed atrial sensitivity, which can be enhanced with the use of ASA, particularly when P wave sensing during AF is borderline.

Adult↗

Detection of atrial fibrillation during sinus tachycardia induced by exercise in patients with implantable atrial defibrillators.

Accurate detection of atrial fibrillation (AF) is essential for appropriate operation of an implantable atrial defibrillator (IAD). However, during episodes of sinus tachycardia, distinction between AF and sinus rhythm (SR) using the "quiet interval" and "baseline crossing" analysis in the detection algorithm of the IAD may be difficult. The efficacy of this AF detection algorithm was tested in five patients implanted with an IAD (METRIX, Model 3000 or 3020, InControl Inc.) during treadmill exercise testing. The IADs were programmed to Monitor Mode with a wake up cycle of 1 minute for AF detection using the device nominal parameters or modified parameters, and to mark rhythms appropriate for shock delivery. A mean peak heart rate of 137 +/- 26 beats/min was reached during maximum exercise, and one patient developed transient AF. Seventy-eight (75 in SR, 3 in AF) and 91 (89 in SR, 2 in AF) runs of AF detection were performed using the nominal and modified parameters, respectively. The IAD detected AF and SR accurately, except for one episode of false-positive AF detection during sinus tachycardia at the nominal settings, but inappropriate shocks were prevented by minimum RR interval criteria that limited discharge at high heart rate. These results indicate that the AF detection algorithm in the IAD may become more vulnerable to false-positive AF detection during sinus tachycardia, which were avoided by reprogramming the Quiet Interval and minimum RR interval criteria for AF detection. Exercise testing appeared useful to program optimal settings of the IAD in preparation for daily activities.

Aged↗

Target temperatures of 48 degrees C versus 60 degrees C during slow pathway ablation: a randomized comparison.

INTRODUCTION: The relationship between temperature at the electrode-tissue interface and the loss of AV and ventriculoatrial (VA) conduction is not established, and the optimal target temperature for the slow pathway approach to radiofrequency ablation of AV nodal reentrant tachycardia (AVNRT) is unknown. Therefore, the purpose of this study was to compare target temperatures of 48 degrees C and 60 degrees C during the slow pathway approach to ablation of AVNRT. METHODS AND RESULTS: The study included 138 patients undergoing ablation for AVNRT. Patients undergoing slow pathway ablation using closed-loop temperature monitoring were randomly assigned to a target temperature of either 48 degrees C or 60 degrees C. The primary success rates were 76% in the patients assigned to 48 degrees C and 100% in the patients assigned to 60 degrees C (P < 0.01). The ablation procedure duration (33 +/- 31 min vs 26 +/- 28 min; P = 0.2), fluoroscopic time (25 +/- 15 min vs 24 +/- 16 min; P = 0.5), and mean number of applications (9.3 +/- 6.5 vs 7.8 +/- 8.1; P = 0.3) were similar in patients assigned to 48 degrees and 60 degrees C, respectively. The mean temperature (46.1 degrees +/- 24.8 degrees C vs 48.7 +/- 3.2 degrees C; P < 0.01), the temperature associated with junctional ectopy (48.1 degrees +/- 2.0 degrees C vs 53.5 degrees +/- 3.5 degrees C, P < 0.0001), and the frequency of VA block during junctional ectopy (24.6% vs 37.2%; P < 0.0001) were less in the patients assigned to 48 degrees C compared to 60 degrees C. The frequency of transient or permanent AV block was similar in each group (2.8% vs 3.6%; P = 0.2). In the 60 degrees C group, only 12% of applications achieved an electrode temperature of 60 degrees C. During follow-up of 9.9 +/- 4.2 months, there was one recurrence of AVNRT in the 48 degrees C group and none in the 60 degrees C group. CONCLUSIONS: Compared to 48 degrees C, a target temperature of 60 degrees C during radiofrequency slow pathway ablation is associated with a higher primary success rate and a higher incidence of VA block during junctional ectopy induced by the radiofrequency energy. AV block is not more common with the higher target temperature, but only if VA conduction is aggressively monitored during applications of radiofrequency energy.

Adult↗

Effect of the implantable atrial defibrillator on the natural history of atrial fibrillation.

INTRODUCTION: The purpose of our study was to evaluate the effect of repeated cardioversion with an implantable atrial defibrillator on the clinical outcome of patients with atrial fibrillation. METHODS AND RESULTS: The effects of the implantable atrial defibrillator on the total duration of atrial fibrillation, number of atrial fibrillation recurrences, and left atrial size were evaluated prospectively in 16 patients with atrial fibrillation (13 men and 3 women; mean age 58 +/- 11 years). Seven patients had no cardiovascular disease, 5 patients had hypertension, 3 patients had coronary heart disease, and 1 patient had congenital heart disease. Eight patients had paroxysmal atrial fibrillation for a mean duration of 80 +/- 61 months, and eight patients had persistent atrial fibrillation for a mean duration of 68 +/- 119 months. Except for one patient who received digoxin throughout the study, all patients received the same Class I or III antiarrhythmic agent throughout the study. The implantable atrial defibrillator successfully converted 50 (93%) of 54 spontaneous episodes of atrial fibrillation in 12 patients. During the initial 3 months of clinical follow-up, the atrial defibrillator documented 261 +/- 270 hours of atrial fibrillation compared with 126 +/- 172 hours (P = 0.01) during the subsequent 3 months. The left atrial size decreased from 4.4 +/- 0.7 cm at the time of atrial defibrillator implantation to 4.1 +/- 0.6 cm (P = 0.02) 6 months later. The number of atrial fibrillation recurrences did not change. These findings were observed in the absence of changes in drug therapy. No complications were observed. CONCLUSION: Restoration and maintenance of sinus rhythm in patients with atrial fibrillation by repeated cardioversion with an implantable atrial defibrillator was associated with a reduction in the total arrhythmia duration and a reduction in left atrial size. These results suggest that maintenance of sinus rhythm with the atrial defibrillator may reverse the remodeling process associated with atrial fibrillation.

Adult↗

Heterogeneous changes in electrophysiologic properties in the paroxysmal and chronically fibrillating human atrium.

INTRODUCTION: The regional changes in atrial electrophysiologic properties related to atrial fibrillation (AF) in patients with paroxysmal AF (PAF) and chronic AF (CAF) remain unclear. The purpose of this study was to investigate the regional changes in atrial electrophysiology in patients with AF. METHODS AND RESULTS: We evaluated the atrial electrophysiology at different sites (high right atrium, low right atrium [LRA], and distal coronary sinus [DCS]) in 11 patients with CAF, 8 patients with PAF, and 10 controls. Patients with CAF had significantly prolonged interatrial conduction and corrected sinus node recovery time, and shortened atrial effective refractory period (ERP) with loss of rate-related adaptation in the DCS, but had paradoxic prolongation of atrial ERP in the LRA, as compared with patients with PAF and the controls. As a result, the spatial distribution of atrial ERP that was observed in the controls and in patients with PAF was reversed in patients with CAF, without an increase in the dispersion of atrial refractoriness. Patients with PAF showed intermediate changes in atrial conduction times and atrial refractoriness as compared with patients with CAF and controls. CONCLUSION: There was a regional heterogeneity on the changes of atrial electrophysiology in different parts of the atrium, and the "normal" spatial distribution of atrial refractoriness was reversed in patients with CAF. The electrophysiologic changes observed in patients with PAF appear to behave as if in transition from the control state to CAF, suggesting progressive changes in atrial electrophysiologic properties.

Aged↗

Incidence and modes of onset of early reinitiation of atrial fibrillation after successful internal cardioversion, and its prevention by intravenous sotalol.

OBJECTIVES: To study the incidence and mode of onset of early reinitiation of atrial fibrillation (ERAF) following successful internal cardioversion of chronic atrial fibrillation, and to determine the effects of sotalol in the prevention of ERAF. DESIGN: The incidence and modes of onset of ERAF and the acute effects of intravenous sotalol in the prevention of ERAF were studied retrospectively. SETTING: Electrophysiology laboratory at a university teaching hospital. PATIENTS: 64 patients, mean (SD) age 62 (10) years, who underwent internal cardioversion of chronic atrial fibrillation (mean duration of atrial fibrillation 31 (39) months). MAIN OUTCOME MEASURES: ECGs and intracardiac electrograms recorded during the internal cardioversion of atrial fibrillation using 3/3 ms biphasic, R wave synchronised shocks. RESULTS: 52 patients (81%) had successful electrical cardioversion, and 20 (31%) of these had ERAF during the procedure. There was no clinical predictor for the occurrence of ERAF. Fifty eight episodes of ERAF were observed. Five ERAF episodes (9%) had preceding bradycardia and 53 (91%) of these were triggered by atrial premature beats with normal preceding heart rate. Atrial premature beats that reinitiated atrial fibrillation had a shorter coupling interval (333 (43) ms v 396 (100), p < 0.001) and a lower prematurity index (0.44 (0.11) v 0. 55 (0.14), p < 0.001) than those that did not reinitiate atrial fibrillation. Repeated shock delivery and increasing the defibrillation energy did not prevent ERAF. Intravenous sotalol infusion decreased the numbers of atrial premature beats and prolonged their coupling interval, and prevented ERAF after repeated defibrillation in 83% of patients with ERAF. CONCLUSIONS: ERAF is a significant clinical problem after successful internal cardioversion of chronic atrial fibrillation, and was observed in up to 31% of patients. In most episodes, ERAF was triggered by short coupling atrial premature beats with preceding normal heart rate. Intravenous sotalol was effective in preventing ERAF in most cases.

Adrenergic beta-Antagonists↗

Pulmonary hypertension secondary to systemic lupus erythematosus: prolonged survival following treatment with intermittent low dose iloprost.

Pulmonary hypertension (PHT) associated with systemic lupus erythematosus (SLE) has a dismal prognosis. Vasodilators and immunosuppressive therapy have been tried over the years with discouraging results. Prostacyclin (PGI2) which has potent vasodilatatory and anti-platelet effects has been demonstrated to significantly decrease pulmonary arterial pressure and pulmonary vascular resistance during acute infusion. Satisfactory response has been reported in SLE patients with PHT treated with short-term intravenous continuous PGI2 infusion. We report here a 48-month experience of the use of monthly low dose infusion of a PGI2 analogue, iloprost, in a SLE patient with pulmonary hypertension in New York Heart Association functional Class III. There was an initial haemodynamic response to an acute infusion of iloprost. Repeated infusions were followed by marked improvement in her functional status and her mean pulmonary arterial pressure dropped from 80 mmHg in the first few months and remained static at around 55 mmHg for the subsequent years.

Adult↗

Atrioverter: an implantable device for the treatment of atrial fibrillation.

BACKGROUND: During atrial fibrillation, electrophysiological changes occur in atrial tissue that favor the maintenance of the arrhythmia and facilitate recurrence after conversion to sinus rhythm. An implantable defibrillator connected to right atrial and coronary sinus defibrillation leads allows prompt restoration of sinus rhythm by a low-energy shock. The safety and efficacy of this system, called the Atrioverter, were evaluated in a prospective, multicenter study. METHODS AND RESULTS: The study included 51 patients with recurrent atrial fibrillation who had not responded to antiarrhythmic drugs, were in New York Heart Association Heart failure class I or II, and were at low risk for ventricular arrhythmias. The atrial defibrillation threshold had to be </=240 V during preimplant testing. Atrial fibrillation detection, R-wave shock synchronization, and defibrillation threshold were tested at implantation and during follow-up. Shock termination of spontaneous episodes of atrial fibrillation was performed under physician observation. Results are given after a minimum of 3 months of follow-up. During a follow-up of 72 to 613 days (mean, 259+/-138 days), 96% of 227 spontaneous episodes of atrial fibrillation in 41 patients were successfully converted to sinus rhythm by the Atrioverter. In 27% of episodes, several shocks were required because of early recurrence of atrial fibrillation. Shocks did not induce ventricular arrhythmias. Most patients received antiarrhythmic medication during follow-up. In 4 patients, the Atrioverter was removed: in 1 because of infection, in 1 because of cardiac tamponade, and in 1 because of frequent episodes of atrial fibrillation requiring His bundle ablation. CONCLUSIONS: With the Atrioverter, prompt and safe restoration of sinus rhythm is possible in patients with recurrent atrial fibrillation.

Adult↗