The current status of single lead dual chamber sensing and pacing.

The use of single lead, atrial synchronous ventricular (VDD) pacing in patients with high grade atrioventricular (AV) block and normal sinus node function is an acceptable alternative to dual chamber (DDD) pacing. Implantation and follow up procedures are simplified, and cost is usually reduced by more than the cost of an additional atrial lead. With the use of either diagonally arranged dipole or closely spaced ring electrodes, reliable atrial sensing can be achieved using differential atrial amplifier and high atrial sensitivity. Also oversensing is infrequently observed using provocation tests and dynamic recordings, clinical undersensing is unusual and minimized by programming to the highest atrial sensitivity. However, as atrial pacing is not possible, loss of AV synchrony and rate response may occur for unrecognized or progressive sinus node disease and lower rate limit. The development of single lead dual chamber pacing system may overcome this limitation. Recent studies have demonstrated that atrial pacing can be effective either with the use of a special pacing lead configuration or via floating atrial electrode with a novel stimulation method. Overlapping Biphasic Impulse (OLBI) can reduce atrial pacing threshold. Early clinical experience suggested that this new pacing method can provide effective and reliable atrial pacing with a relatively low incidence of diaphragmatic pacing. Thus the problem of atrial sensing is solved with a single pass lead but further long term evaluation is required to assess the efficacy and feasibility of new instrumentation for single lead dual chamber pacing.

Cardiac Pacing, Artificial↗

Electrophysiological properties of the fibrillating atrium: implications for therapy.

1. Atrial fibrillation (AF) is the most commonly occurring cardiac dysrhythmia and remains a challenge to medical therapy. Although the disorder has been recognized for over 100 years, surprisingly very little is understood about its pathophysiology. Over the past decade, a variety of experimental and animal models of AF have been developed and these have provided insights into the mechanism of AF. 2. The pathophysiology of AF is complex. Atrial fibrillation can be caused either by a single source of very rapid impulses or, in the majority of cases, by multiple random re-entering wavelets. The notion that AF may be initiated by a single rapid firing focus and the perpetuation of AF may be partly dependent on macro re-entry around the natural atrial orifices provides a new potential curative therapy for AF by radiofrequency ablation. 3. Shortening of atrial wavelength, either by slow atrial conduction velocities, short atrial refractory periods or both, seems to predispose to development of intra-atrial re-entry and, thus, AF. The functional mechanism by which anti-arrhythmic drugs terminate AF appears to be by prolonging the wavelength and decreasing the number of re-entry wavelets. These understandings are important for the future development of effective anti-arrhythmic agents against AF. 4. The presence of a short and variable excitable gap during AF may be potentially important for termination of AF by pacing. 5. New insights are being gained into the potential role and mechanism of electrical remodelling of the atrium due to AF. Repeated induction of AF by rapid atrial pacing leads to a shortening of atrial refractoriness with loss of rate adaptation, which favours the induction and maintenance of AF. These electrophysiological changes were assumed to occur during repeated AF and to facilitate the generation of multiple re-entrant wavelets. These data suggest that prompt restoration of sinus rhythm and new novel therapy that prevents or diminishes electrical remodelling may promote maintenance of sinus rhythm after successful cardioversion.

Animals↗

Programmed atrial sensitivity: a critical determinant in atrial fibrillation detection and optimal automatic mode switching.

Automatic mode switching (AMS) prevents tracking of paroxysmal atrial fibrillation (AF) in dual chamber pacing. The correct detection of AF can be affected by the programmed atrial sensitivity (AS). We prospectively studied the relationship between AS, AF undersensing, and AMS, using unfiltered bipolar intracardiac atrial electrograms recorded from 17 patients during sinus rhythm (SR) and in AF. Overall, 780 rhythms were recorded and replayed onto three dual chamber pacemaker models using different AMS algorithms (Thera DR 7940, Marathon DDDR 294-09, and Meta DDDR 1254), and the ventricular responses were measured. AS was randomly programmed in steps from the highest available AS to half of the mean atrial P wave amplitude (PWA), and the percentage of appropriate AMS responses (defined as a ventricular pacing rate at the expected AMS mode) were recorded. AMS efficacy was related to the programmed AS settings in an exponential manner. At low AS settings, a higher percentage of tests were associated with absence of, or with intermittent AMS and tracking of AF, whereas at higher AS, oversensing of noise during SR occurred. An optimal AS measured approximately 1.3 mV, representing about one-third of the PWA measured during SR, although oversensing of SR and undersensing of AF continued to occur in 14% of tests and time, respectively, due to the high variation in PWA during AF. Thus, a fixed AS cannot eliminate AF undersensing without inviting noise oversensing, suggesting the need for automatic adjustments of AS, or the use of a rate-limiting algorithm to prevent rate oscillation during intermittent AF sensing. In conclusion, AMS functions of existing pacemakers were significantly limited by the undersensing of AF and oversensing of noise. Proper adjustment of the AS is important to enable effective AMS during AF.

Algorithms↗

Atrial sensing and pacing with a single pass ventricular lead.

The use of single lead for atrial synchronous ventricular (VDD) pacing in patients with high grade atrioventricular (AV) block and normal sinus node function is an acceptable alternative to dual chamber (DDD) pacing. Implantation and follow up procedures are simplified, and cost is usually reduced by more than the cost of an additional atrial lead. With the use of either diagonally arranged dipole or closely spaced ring electrodes, reliable atrial sensing can be achieved using differential atrial amplifier and high atrial sensitivity. Also oversensing is infrequently observed using provocation tests and dynamic recordings, clinical undersensing is unusual and minimized by programming to the highest atrial sensitivity. However, as atrial pacing is not possible, loss of AV synchrony and rate response may occur for unrecognized or progressive sinus node disease and lower rate limit. The development of single lead dual chamber pacing system may overcome this limitation. Recent studies have demonstrated that atrial pacing can be effective either with the use of a special pacing lead configuration or via floating atrial electrode with a novel stimulation method. Overlapping biphasic impulse (OLBI) can reduce atrial pacing threshold. Early clinical experience suggested that this new pacing method can provide effective and reliable atrial pacing with a relatively low incidence of diaphragmatic pacing. Thus the problem of atrial sensing is solved with a single pass lead but further long term evaluation is required to assess the efficacy and feasibility of new instrumentation for single lead dual chamber pacing.

Cardiac Pacing, Artificial↗

Clinical shock tolerability and effect of different right atrial electrode locations on efficacy of low energy human transvenous atrial defibrillation using an implantable lead system.

OBJECTIVES: The objectives of this study were 1) to evaluate the effect of different right atrial electrode locations on the efficacy of low energy transvenous defibrillation with an implantable lead system; and 2) to qualitate and quantify the discomfort from atrial defibrillation shocks delivered by a clinically relevant method. BACKGROUND: Biatrial shocks result in the lowest thresholds for transvenous atrial defibrillation, but the optimal right atrial and coronary sinus electrode locations for defibrillation efficacy in humans have not been defined. METHODS: Twenty-eight patients (17 men, 11 women) with chronic atrial fibrillation (AF) (lasting > or = 1 month) were studied. Transvenous atrial defibrillation was performed by delivering R wave-synchronized biphasic shocks with incremental shock levels (from 180 to 400 V in steps of 40 V). Different electrode location combinations were used and tested randomly: the anterolateral, inferomedial right atrium or high right atrial appendage to the distal coronary sinus. Defibrillation thresholds were defined in duplicate by using the step-up protocol. Pain perception of shock delivery was assessed by using a purpose-designed questionnaire; sedation was given when the shock level was unacceptable (tolerability threshold). RESULTS: Sinus rhythm was restored in 26 of 28 patients by using at least one of the right atrial electrode locations tested. The conversion rate with the anterolateral right atrial location (21 [81%] of 26) was higher than that with the inferomedial right atrial location (8 [50%] of 16, p < 0.05) but similar to that with the high right atrial appendage location (16 [89%] of 18, p > 0.05). The mean defibrillation thresholds for the high right atrial appendage, anterolateral right atrium and inferomedial right atrium were all significantly different with respect to energy (3.9 +/- 1.8 J vs. 4.6 +/- 1.8 J vs. 6.0 +/- 1.7 J, respectively, p < 0.05) and voltage (317 +/- 77 V vs. 348 +/- 70 V vs. 396 +/- 66 V, respectively, p < 0.05). Patients tolerated a mean of 3.4 +/- 2 shocks with a tolerability threshold of 255 +/- 60 V, 2.5 +/- 1.3 J. CONCLUSIONS: Low energy transvenous defibrillation with an implantable defibrillation lead system is an effective treatment for AF. Most patients can tolerate two to three shocks, and, when the starting shock level (180 V) is close to the defibrillation threshold, they can tolerate on average a shock level of 260 V without sedation. Electrodes should be positioned in the distal coronary sinus and in the high right atrial appendage to achieve the lowest defibrillation threshold, although other locations may be suitable for certain patients.

Adult↗

Long-term effect of right ventricular pacing on myocardial perfusion and function.

OBJECTIVES: The purpose of this study was to investigate the effect of long-term ventricular pacing on myocardial perfusion and function in patients receiving such pacing. BACKGROUND: The long-term effect of ventricular pacing on myocardial perfusion and function in humans is unclear, although animal studies have suggested that it may be adverse. METHODS: Forty-three patients with complete heart block and dual-chamber rate-adaptive (DDDR) pacing were studied. All underwent thallium-201 (Tl-201) exercise myocardial scintigraphy to assess myocardial perfusion and radionuclide ventriculography to determine left ventricular function and regional wall motion. Coronary angiography was also performed in patients with abnormal findings on Tl-201 study. RESULTS: There was no significant difference in mean age, gender, percent ventricular pacing, pacing threshold, ventricular pacing output and metabolic equivalents on exercise testing between patients with or without perfusion defects on exercise Tl-201 scintigraphy. However, the duration of pacing tended to be longer in patients with than in those without perfusion defects (43.9 +/- 49.7 vs. 20.1 +/- 9.8 months, p = 0.05). Tl-201 perfusion defects were noted in 28 (65%) of 43 of patients (inferior 78% [n = 22], apical 67% [n = 17], septal 21% [n = 6], anterior 7% [n = 2], lateral 3% [n = 1)]. Of 16 of 28 patients with abnormal Tl-201 findings who underwent coronary angiography, only 3 (19%) had significant coronary artery disease. Patients with an abnormal perfusion defect had a significantly lower left ventricular ejection fraction (48.5 +/- 9.9% vs. 59.6 +/- 8.9%, p < 0.001) and a higher percent of wall motion abnormalities (57% vs. 20%, p = 0.026), mainly over apical regions. CONCLUSIONS: Long-term right ventricular apical pacing resulted in a high incidence of myocardial perfusion defects that increased with the duration of pacing. These myocardial perfusion abnormalities were associated with apical wall motion abnormalities and impaired global left ventricular function.

Aged↗

Relation between mitral regurgitation and platelet activation.

OBJECTIVES: This study sought to examine the effect of mitral regurgitation (MR) on platelet activation in patients with mitral valve prolapse (MVP) or rheumatic MR. BACKGROUND: MVP and rheumatic MR are associated with an increased incidence of thromboembolic events. Although the underlying causes are not clear, increased platelet activation has been suggested as one of the pathogenic mechanisms. Results of previous studies that have investigated the relation between MVP and platelet activation are controversial. Whether the presence of MR in patients with mitral valve disease is associated with platelet activation remains unclear. METHODS: We studied platelet activation by measuring the plasma level of platelet factor 4 (PF4) and beta-thromboglobulin (BTG) in 16 patients with MVP, 12 patients with rheumatic MR and 25 control subjects. A detailed echocardiographic examination, including M-mode measurement and color Doppler flow mapping to detect the presence and severity of MR was performed. RESULTS: Patients and control subjects were matched for gender, age and left ventricular ejection fraction. Eight (50%) of 16 patients with MVP had MR. Patients with MVP and MR and patients with rheumatic MR had a significantly larger left atrial diameter. Mean log plasma levels of PF4 and BTG were significantly higher in patients with MVP and MR and patients with rheumatic MR than in control subjects (1.17 +/- 0.22 and 0.93 +/- 0.23 IU/ml vs. 0.52 +/- 0.34 IU/ml, p < 0.01; 1.70 +/- 0.21 and 1.53 +/- 0.15 IU/ml vs. 1.37 +/- 0.15 IU/ml, p < 0.05, respectively) but were comparable in patients with MVP and no MR and control subjects. Plasma levels of PF4 and BTG were positively correlated with the severity of MR, as assessed by a semiquantitative method (r = 0.59, p = 0.0001; r = 0.60, p = 0.0001, respectively). Increasing age and left atrial enlargement were not related to platelet activation. CONCLUSIONS: MR in mitral valve disease was associated with systemic platelet activation. MVP itself was not associated with increased platelet activation. The degree of platelet activation was positively correlated with the severity of MR and was independent of the underlying etiology of mitral valve disease, age and left atrial size. The possibility of a higher incidence of thromboembolism and the role of antiplatelet agents in such patients will require further studies to determine.

Adult↗

Electrical remodelling of chronic atrial fibrillation.

1. It is now recognized that atrial fibrillation (AF) is not a benign condition, as it is associated with a 40% increase in mortality and a doubling of the risk of stroke. 2. The development of AF leads to mechanical, electrophysiological and cellular changes in the atria that tend to sustain AF. This process is known as atrial remodelling. 3. The three electrophysiological elements in the atria that initiate and sustain AF are: (i) shortening of the refractory period and an increase in dispersion; (ii) slowing of conduction velocity; and (iii) the presence of triggering foci. 4. As AF is a heterogeneous disorder, therapeutic strategies include the use of devices (pacemakers and atrial defibrillators), radiofrequency ablation (focal ablation or the creation of linear lines) and drug therapy that may reverse a remodelled atrium.

Atrial Fibrillation↗

Initial clinical experience with an implantable human atrial defibrillator.

Low energy biatrial shock is an effective means of restoring sinus rhythm in patients with atrial fibrillation (AF). Ventricular proarrhythmia is avoided provided that shocks are well synchronized to R waves that are not at closely coupled intervals or preceded by long-short cycles. Based on these principles, an implantable atrial defibrillator has been developed and was implanted in three patients with drug refractory paroxysmal AF. The device detects AF via an actively fixed right atrial and a self-retaining coronary sinus defibrillating leads, and delivers 3/3 ms biphasic shocks up to 300 V synchronized to the R wave. The mean implant threshold (ED50) was 195 V (1.8 J). and minimum voltage at conversion during follow-up assessments at 1, 3, and 6 months were 260 V, 2.5 J. 250 V, 2.3 J, and 300 V, 3.0 J respectively. Detection of AF was 100% specific and shocks were 100% synchronized, although only a proportion of synchronized R waves were considered suitable for shock delivery primarily because of closely coupled cycles. Three patients had 9 spontaneous AF episodes, 8/9 (89%) successfully defibrillated by shocks of 260-300 V. Sedation was not used in 4 out of 9 (45%) episodes. Backup ventricular pacing was initiated by the device in 6 out of (67%) episodes. One patient had more frequent AF after lead placement, which subsided after a change of medication. There was no ventricular proarrhythmia. It is concluded that an implantable atrial defibrillator is a viable therapy for selected patients with paroxysmal AF. The device is capable of accurate AF detection, R wave synchronization and ventricular support pacing after successful defibrillation of AF.

Adult↗

Effects of atrioventricular asynchrony on platelet activation: implication of thromboembolism in paced patients.

OBJECTIVE: To investigate the platelet activation in different modes of pacing in patients implanted with dual chamber rate adaptive pacemaker (DDDR) for bradyarrhythmias, and to explore the possible underlying mechanism of the higher thromboembolic incidence in single chamber ventricular rate adaptive (VVIR) pacing. DESIGN: Platelet activation was determined in chronically paced patients during three different pacing modes (VVIR, DDD, and DDDR) in a randomised crossover fashion. SETTING: Pacemaker clinic at a university teaching hospital. PATIENTS: 15 patients with complete heart block, mean (SD) age 63 (10) years, and 12 patients with sick sinus syndrome, mean age 68 (9) years, implanted with DDDR pacemakers. MAIN OUTCOME MEASURES: Platelet activation was assessed by measuring the plasma concentrations of platelet factor 4 (PF4) and beta thromboglobulin using an enzyme linked immunosorbent assay (ELISA). Mean log plasma PF4 and beta thromboglobulin values were compared in paced patients during different pacing modes and with controls. RESULTS: Compared with controls, patients paced in DDDR, DDD, and VVIR modes had higher mean log plasma concentrations of PF4 (0.90 (0.32), 0.92 (0.29), and 1.12 (0.33) v 0.61 (0.29) log IU/ml, all p < 0.05, respectively) and beta thromboglobulin (1.55 (0.20), 1.59 (0.16), and 1.71 (0.18) v 1.40 (0.12) log IU/ml, all p < 0.05, respectively). In paced patients, VVIR pacing was associated with higher plasma concentrations of PF4 and beta thromboglobulin than either DDDR or DDD pacing (all p < 0.05). There was no significant difference in plasma PF4 and beta thromboglobulin between patients with complete heart block and sick sinus syndrome in the corresponding pacing mode. Holter monitoring showed no difference in mean pacing rate and occurrence of cardiac arrhythmias to account for the increased platelet activation during VVIR pacing. There was no relation between the percentage of ventricular pacing on Holter during DDDR, DDD, and VVIR modes and the log mean plasma concentrations of PF4 (r = 0.002, 0.001, and 0.001, respectively, all p > 0.05) and beta thromboglobulin (r = 0.007, 0.01, and 0.001, respectively, all p > 0.05). CONCLUSIONS: Single chamber ventricular pacing was associated with enhanced spontaneous systemic platelet activation compared with physiological dual chamber pacing. This was related to the loss of atrioventricular synchrony rather than to the underlying cause of bradycardia, lack of rate response, or coexisting arrhythmia. This abnormality may be associated with increased thromboembolism and was correctible by an appropriate pacing mode prescription and possibly antiplatelet treatment.

Aged↗

Transesophageal echocardiography in the detection of inferior vena cava and cardiac metastasis in hepatocellular carcinoma.

Antemortem diagnosis of inferior vena cava (IVC) and cardiac metastasis of hepatocellular carcinoma (HCC) is difficult but important before consideration of curative resection. There are only a few cases of cardiac metastasis of HCC which have been diagnosed antemortem by echocardiography. Accordingly, 18 consecutive patients with HCC who were potential candidates for curative resection were studied by transthoracic (TTE) and transesophageal echocardiography (TEE). One (6%) and two (11%) patients had cardiac and IVC metastasis of HCC, respectively, which was detected by two-dimensional TTE. In contrast, by using TEE, four patients (22%) showed tumor invasion of the IVC, of whom two (11%) had tumor mass extending into the right atrium (RA). There was no significant difference in age, serum level of alpha-fetoprotein, and percentage of right liver lobar involvement between those with and without cardiac metastasis. Patients without cardiac metastasis detected on TTE or TEE had significantly longer mean duration of survival (5.0 +/- 2.1 vs. 2.1 +/- 1.0 months; p < 0.05). In summary, TEE may be more useful than TTE in the detection of cardiac metastasis of HCC, which occurred in 22% of patients whose primary tumor was considered to be surgically resectable in our series. This can be safely performed in patients with HCC and can provide optimal visualization of the IVC and RA. The high prevalence of subclinical cardiac metastasis in HCC mandates the use of TEE in all patients with HCC prior to surgical intervention.

Age Factors↗

Case report: lysosomal glycogen storage disease with normal acid maltase: an unusual form of hypertrophic cardiomyopathy with rapidly progressive heart failure.

A 14-year-old boy with mild mental retardation, myopathy, and nonobstructive hypertrophic cardiomyopathy (HCM) with clinical and histopathologic features consistent with lysosomal glycogen storage disease with normal acid maltase is described. The case illustrates the aggressive nature of the cardiomyopathy of this syndrome. This condition is associated with malignant ventricular arrhythmias, relentlessly progressive ventricular dilatation, dysfunction, and sudden death. It is important to recognize this unusual and malignant form of HCM to precipitate low early diagnosis by muscle biopsy. Patients with this condition would be excellent candidates for life-saving heart transplant as the myopathy and mental retardation are mild and nonprogressive. The underlying biochemical defect and mode of inheritance of this syndrome are unclear. However, a significant proportion are genetically related and thus, relatives may benefit from family screening.

Adolescent↗

Single lead DDD system: a comparative evaluation of unipolar, bipolar, and overlapping biphasic stimulation and the effects of right atrial floating electrode location on atrial pacing and sensing thresholds.

Single lead DDD pacing using unipolar or bipolar stimulation is limited by high atrial threshold. Overlapping biphasic (OLBI) waveform stimulation via atrial floating ring electrodes may preferentially enhance atrial pacing and avoid diaphragmatic pacing. Single lead DDD pacing with OLBI atrial pacing was studied in 12 patients (6 men and 6 women; mean age 74 +/- 7 years) with complete heart block. At implantation, atrial bipolar rings (area 27 mm2, separation 10 mm) were positioned at radiological defined high, mid, and low right atrial (RA) levels, and P wave amplitude and atrial and diaphragmatic pacing thresholds were determined in each position using unipolar, bipolar, and OLBI stimulation in random order. Although statistically insignificant, both the maximum and minimum sensed P wave amplitudes tended to be lower in the low RA position. Independent of the stimulation modes, minimum atrial pacing threshold occurred in the mid-RA. At mid-RA, the atrial pacing threshold was significantly lower with OLBI pacing compared with either unipolar or bipolar mode (3.9 +/- 2.2 V vs 6.7 +/- 3.5 V and 6.9 +/- 3.5 V, P < 0.05). Although the diaphragmatic thresholds were similar, OLBI pacing modes in the mid-RA and final location significantly improved the safety margin for avoidance of diaphragmatic pacing compared with unipolar mode. There was no correlation between atrial pacing and sensing threshold. At predischarge testing, all but one patient who developed atrial fibrillation had satisfactory atrial capture and a stable atrial pacing threshold (day 0: 2.6 +/- 1.1V vs day 2:3.2 +/- 1.3V, P = NS). However, diaphragmatic pacing occurred in four of 11 (36%) patients, especially in the upright position (sitting and standing). Our preliminary clinical results suggest that OLBI pacing via atrial floating ring electrodes can reduce the atrial pacing threshold. To optimize atrial pacing and sensing, the bipolar electrodes should be located at the mid-RA level first, although the high RA is an alternative. Despite significant improvements in the safety margin for diaphragmatic pacing with OLBI pacing, diaphragmatic stimulation remains a clinical problem.

Aged↗

Exercise-associated cardiac asystole in persons without structural heart disease.

Exercise-associated cardiac asystole (EACA) in patients without structural heart disease is uncommonly encountered. Two patients who developed prolonged asystolic arrest associated with exercise are described; both demonstrated a positive head-up tilt table response, absence of underlying heart disease, and a history of vagotonia. A review of this condition in the literature suggests the occurrence of this syndrome of EACA in young men with atheletic inclination who developed syncope usually after a strenuous exercise at a high heart rate. Although the described patients usually responded by avoiding maximal exercise and the use of beta-blockade, vagolytic agent, and permanent pacing, EACA may be the link for some cases of exercise-related asystolic deaths.

Adult↗

Comparison of digoxin versus low-dose amiodarone for ventricular rate control in patients with chronic atrial fibrillation.

1. Rapid ventricular rate (VR) and rhythm irregularity during atrial fibrillation (AF) impair cardiac performance. Although digoxin has been widely used in patients with AF, its efficacy for the control of VR and rhythm irregularity is unsatisfactory. Whether low-dose amiodarone is more effective remains unclear. 2. We randomized 16 patients (13 male, three female; mean (+/-SD) age 63 +/- 9 years) with chronic AF to receive either digoxin or amiodarone for 24 weeks. At baseline and at 12 and 24 weeks follow up, Holter monitor recording and cardiopulmonary exercise test were performed to assess VR and rhythm irregularity control and exercise capacity. 3. Seven and nine patients received digoxin and amiodarone, respectively. After 12 and 24 weeks treatment, both digoxin and amiodarone significantly decreased the mean ambulatory VR and the VR during peak exercise compared with baseline (all P < 0.05). At 24 weeks, there were no significant differences between digoxin and amiodarone in the percentage reduction in VR during ambulatory (27 +/- 13 vs. 25 +/- 12%, respectively; P = 0.8) and peak exercise (13 +/- 12 vs. 12 +/- 10%%, respectively; P = 0.6). 4. The rhythm irregularity, as measured by SD of RR intervals and the root mean square of the SD of RR intervals, and the exercise capacity, as measured by exercise workload, maximal oxygen consumption (VO2), minute ventilation, ventilatory equivalent and oxygen pulse, were not significantly changed after treatment with digoxin or amiodarone (all P > 0.05). 5. Quality of life, determined by SF-36 questionnaire, and AF symptomatology, as measured by the AF Symptom Checklist, were also not significantly changed after treatment with digoxin or amiodarone (all P > 0.05). 6. In conclusion, digoxin and low-dose amiodarone had similar efficacy in the control of VR during ambulatory activity and exercise. However, both were less efficacious during exercise and did not significantly affect rhythm irregularity, exercise capacity, quality of life and AF symptomatology in patients with chronic AF.

Aged↗