PubMed Health⌕ Search

Biomedical subjects

H Gregersen

Publications and source records attributed to H Gregersen.

At least 55 records · Page 3Linked to original sources

Comparison of methods used for measurement of rectal compliance.

INTRODUCTION: Compliance is defined as the change in volume or cross-sectional area divided by the change in pressure. Pressure-volume measurement during distention with a compliant balloon is the most commonly used method for computation of rectal compliance. However, intraindividual and interindividual variations are large, restricting the usefulness of the method. Other methods such as rectal distention by a large, noncompliant bag and rectal impedance planimetry for assessment of pressure-cross-sectional-area relations have been proposed as alternatives owing to the reduction of errors from elongation of the balloon within the rectal lumen. However, in vivo reproducibility of pressure-volume measurement during distention with a compliant balloon, pressure-volume measurement during rectal distention by a large, noncompliant bag, and rectal impedance planimetry have never been compared. PURPOSE: The aim of this study was to compare in vivo reproducibility of the above-mentioned methods and to study their in vitro reproducibility and validity. METHODS: Ten healthy volunteers (six men) aged 21-59 years were randomized to either rectal pressure-volume measurement with a compliant balloon or rectal impedance planimetry. After a one-hour rest, the other procedure was performed. After two weeks, both procedures were again performed in the same order. During rectal impedance planimetry the volume of the bag used (maximum volume 450 ml; secured at both ends to the probe) was continuously registered, measuring pressure-volume relations during rectal distention by a large, noncompliant bag. Reproducibility was tested by comparing the difference divided by the mean for each method at eight pressure steps in the range from 5 to 40 cm H2O. Furthermore, the in vitro reproducibility and validity of the three methods were studied using polyvinyl chloride tubes with known cross-sectional areas. RESULTS: In vivo reproducibility for pressure-volume measurement with a large, noncompliant bag and rectal impedance planimetry was significantly better than for pressure-volume measurement with a compliant balloon (P = 0.005 and P = 0.019, respectively). No statistically significant difference was found between pressure-volume measurement with a large, noncompliant bag and rectal impedance planimetry (P = 0.20). In vitro reproducibility of pressure-volume measurement with a large, noncompliant bag and rectal impedance planimetry was good, but some elongation occurred, reducing the validity of pressure-volume measurement with a large, noncompliant bag. Coiling and elongation of the balloon within the lumen were major sources of error for pressure-volume measurement with a compliant balloon. CONCLUSION: In vivo and in vitro reproducibility of methods used for measurement of rectal compliance can be improved by restricting the effects of elongation within the lumen either by using a large-volume, noncompliant bag or by rectal impedance planimetry. However, pressure-volume measurement will to some degree depend on the properties of the balloons or bags.

Adult↗

Regional distribution of axial strain and circumferential residual strain in the layered rabbit oesophagus.

The oesophagus is subjected to large axial strains in vivo and the zero-stress state is not a closed cylinder but an open circular cylindrical sector. The closed cylinder with no external loads applied is called the no-load state and residual strain is the difference in strain between the no-load state and zero-stress state. To understand oesophageal physiology and pathophysiology, it is necessary to know the distribution of axial strain, the zero-stress state, the stress-strain relations of oesophageal tissue, and the changes of these states and relationships due to biological remodeling of the tissue under stress. This study is addressed to such biomechanical properties in normal rabbits. The oesophagi were marked on the surface in vivo, photographed, excised (in vitro state), photographed again, and sectioned into rings (no-load state) in an organ bath containing calcium-free Kreb's solution with dextran and EGTA added. The rings were cut radially to obtain the zero-stress state for the non-separated wall and further dissected to separate the muscle and submucosa layers. Equilibrium was awaited for 30min in each state and the specimens were photographed in no-load and the zero-stress states. The oesophageal length, circumferences, layer thicknesses and areas, and openings angle were measured from the digitised images. The oesophagus shortened axially by 35% after excision. The in vivo axial strain showed a significant variation with the highest values in the mid-oesophagus (p<0.001). Luminal area, circumferences, and wall and layer thicknesses and areas varied in axial direction (in all tests p<0.05). The residual strain was compressive at the mucosal surface and tensile at the serosal surface. The dissection studies demonstrated shear forces between the two layers in the non-separated wall in the no-load and zero-stress states. In conclusion, our data show significant axial variation in passive morphometric and biomechanical properties of the oesophagus. The oesophagus is a layered composite structure with nonlinear and anisotropic mechanical behaviour.

Animals↗

Propagation speed of sound assessment in the layers of the guinea-pig esophagus in vitro by means of acoustic microscopy.

The study's purpose was to evaluate the propagation speed of sound in the tissue layers of the esophagus at various mechanical loadings. Scanning laser acoustics microscopy was applied for the estimation of the propagation speed in the mucosa-submucosa and muscle layers of guinea-pig esophagus in vitro (n = 26). The propagation speed in the esophagus was determined in the no-load state with all external forces removed, and in the distended and zero-stress states. The zero-stress state was obtained by cutting the esophageal rings radially. The propagation speed in the no-load state differed significantly (p < 0.001) between the muscle layer (median 1740, quartiles 1735-1746 m/s) and the mucosa (1607, 1605-1609 m/s). In the distended state the propagation speed in the muscle layer decreased significantly (p < 0.001) to 1673 (1666-1681) m/s while it did not change significantly in mucosa (1602, 1600-1607 m/s). When compared to the no-load state, the propagation speed in the zero-stress state in the muscle layers decreased to 1624 (1615-1636) m/s (p < 0.001) and in mucosa to 1584 (1566-1603) m/s (p < 0.001). In conclusion, the esophagus is a composite structure with heterogeneous propagation speed characteristics. Furthermore, the mechanical loading state must be considered in esophageal ultrasound studies.

Acoustics↗

Effect of re-feeding after starvation on biomechanical properties in rat small intestine.

Luminal nutrients are essential for maintaining the structural and functional integrity of the gut. Starvation induces pronounced structural and biomechanical remodelling in the rat small intestine. The present work was done to study the recovery process after resumption of food intake. Twenty-five Wistar rats were allocated to five groups. Four groups fasted for 7 days but had free access to water. One of these groups served as fasted controls and was killed at the end of the fast. The other three groups were re-fed for 2, 4 and 7 days before they were euthanised. The fifth group had free access to food during the whole study (fed controls). The intestinal no-load state, zero-stress state and the stress-strain relationship during distension were studied. The intestinal segments were cut transversely into a series of short ring-shaped segments to obtain the no-load state. Each ring was cut in the radial direction to obtain the zero-stress state. The rats regained the lost body weight (22%) by the 7th day of re-feeding. The lost duodenal mass (40%) and jejunal mass (25%) were regained by the 2nd day whereas the lost mass from ileum (18%) was regained by the 4th day. The fasting-induced morphometric changes were normalised by re-feeding on the 2nd day in the duodenum and jejunum, and on the 4th day in the ileum. The longitudinal stress-strain curves shifted to the right after fasting and shifted back within two days following re-feeding (P<0.05). The circumferential stress-strain curves in the fasted or re-fed rats changed in a similar though less pronounced way. Normal values were reached within 4-7 days for the circumferential direction. In conclusion, fasting-induced biomechanical and structural remodelling were normalised by re-feeding in a time- and location-dependent way.

Animals↗

Tension-strain relations and morphometry of rat small intestine in experimental diabetes.

Tension-strain relations and morphometric data were studied in isolated segments of the jejunum and distal ileum in untreated diabetic rats, insulin-treated diabetic rats, and nondiabetic control rats. Diabetes was induced by a single intravenous injection of streptozotocin (28 mg/kg body wt). All injected rats developed hyperglycemia. The experiment was terminated after 28 days and the intestinal segments were superfused with saline solution containing papaverine to abolish contractile activity. Stepwise inflation of a balloon in which the cross-sectional area (CSA) was measured provided the luminal pressure-loading stimulus. The circumferential tension-strain relation was derived from steady-state values of internal radius and applied pressure. The intestinal weight, length, and weight per unit length increased significantly in untreated diabetic rats compared to the two other groups (P < 0.05). The body weight decreased in untreated diabetic rats compared to the two other groups (P < 0.05). The pressure-CSA relations differed between jejunum and distal ileum (P < 0.001) but not between the groups (P > 0.2). The tension-strain relations in jejunum and distal ileum were nonlinear and the curves for the two diabetic groups were shifted to the left compared to the curve for controls (P < 0.05), indicating increased wall stiffness. The histomorphometric data showed increased wall thickness in untreated diabetic rats compared to the two other groups both in jejunum and distal ileum (P < 0.02). Mucosal, submucosal, and muscle layer thicknesses did not differ between the three groups. No significant association was found between the histomorphometric and biomechanical parameters.

Animals↗

Axial stretch modifies contractility of porcine coronary arteries by a protein kinase C-dependent mechanism.

Large coronary arteries undergo marked circumferential and axial deformations due to changes in blood pressure and gross movements of the ventricular wall during systole and diastole. The present study was designed to investigate 1) whether axial stretch of large coronary arteries influences the sensitivity to vasoconstrictors, 2) the mechanisms mediating stretch-dependent changes in vascular sensitivity. Endothelium-denuded cylindrical segments from large porcine coronary arteries were studied under isometric conditions using a balloon-based impedance planimetric technique. In segments subjected to a pressure of 60 mmHg, 20% axial stretch caused a left-ward shift of the concentration-response curves for K+ and 5-hydroxytryptamine (5-HT). Enhancement of vascular sensitivity to 5-HT induced by axial stretch was observed also in maximally K+-depolarized coronary arteries. Protein kinase C inhibition by calphostin C (1 microM) slightly decreased the spontaneous resting tone at 60 mmHg and inhibited the leftward shift of the concentration-response curve for 5-HT elicited by axial stretch. These results suggest that axial stretch of the vessel wall enhances the sensitivity of coronary arteries to vasoconstrictors by a protein kinase C-dependent mechanism.

Animals↗

Mortality and causes of death in patients with monoclonal gammopathy of undetermined significance.

To evaluate the mortality and causes of death in monoclonal gammopathy of undetermined significance (MGUS), we identified 1324 cases of MGUS in the period 1978-93 in North Jutland County, Denmark. Data on mortality were obtained by record linkage to the Danish Death Registry. There were 868 deaths in the MGUS cohort during 7785 years of follow-up vs. 409.6 expected, giving a standardized mortality ratio (SMR) of 2.1 (95% confidence interval 2.0-2.3). Malignant transformation was the cause of death in 97 patients vs. 4.9 expected, yielding a SMR of 20.0 (16.2-24.4), which explained about 20% of the excess mortality in the cohort. The mortality was increased for several other malignant and non-malignant causes of death during the first 4 years of follow-up. For late follow-up, 5-18 years after detection of the M-component, the overall SMR was 1.7 (1.5-1.9), and malignant transformation was the only cause of death with a substantial increase of SMR. Although malignant transformation is an important cause of death in MGUS patients, it did not entirely explain the increased mortality. MGUS patients often suffer from coexisting clinical conditions that increase the mortality, especially during the first years after detection of the M-component.

Bronchitis↗

Oesophageal pressure-cross-sectional area distributions and secondary peristalsis in relation to subclassification of systemic sclerosis.

The aim of the present study was to correlate the severity of oesophageal motor dysfunction with the severity of cutaneous disease in systemic sclerosis (SS). Patients were divided into three groups based on the degree of skin involvement: type I, acrosclerosis distal to the wrist; type II, scleroderma extending above the wrist in proximal direction; type III, diffuse cutaneous systemic sclerosis. Impedance planimetry employing distensions with pressures up to 5 kPa with the concomitant measurement of oesophageal cross-sectional area (CSA) was used in combination with standard oesophageal manometry. Measurements were made at 7 and 15 cm above the lower oesophageal sphincter (LOS). Thirty patients (16 type I, six type II and eight type III patients) and 23 normal controls were included. LOS pressure was lower in SS patients than in normal patients, with the lowest values in type III. The CSAs were higher in SS patients than in controls at both sites (P < 0.001). The CSAs at the distal site were highest in type III, as compared to type I and II (P < 0.03). The CSA at the highest induced pressure (5.0 kPa) was 613 +/- 45, 719 +/- 79, and 808 +/- 115 mm2 in types I, II and III, respectively. No differences in CSA were found at the proximal site between the three types of SS. The distensibility did not differ between SS and normal patients at the distal site. The distensibility was lowest in SS patients (P < 0.001) at the proximal distension site. The distensibility did not vary with the type of SS at either site. Significant differences in contraction frequency of the secondary peristalsis as function of wall tension were demonstrated between the SS patients and controls at the distal site (P < 0.05). No differences were found at the proximal site. The contraction frequency and amplitude at the distal and proximal sites did not differ among the three types. In conclusion for most parameters studied, SS patients differed from normal patients. Among SS types, the most pronounced changes were found in type III.

Adult↗

Oesophageal morphometry and residual strain in a mouse model of osteogenesis imperfecta.

Recently, it was demonstrated in the oesophagus that the zero-stress state is not a closed cylinder but an open circular cylindrical sector. The closed cylinder with no external loads applied is called the no-load state and residual strain is the difference in strain between the no-load state and the zero-stress state. To understand the physiology and pathology of the oesophagus, it is necessary to know the zero-stress state and the stress-strain relationships of the tissues in the oesophagus, and the changes of these states and relationships due to biological remodelling of the tissues under stress. The aim of this study was to investigate the morphological and biomechanical remodelling at the no-load and zero-stress states in mutant osteogenesis imperfecta murine (oim) mice with collagen deficiency. The oesophagi of seven oim and seven normal wild-type mice were excised, cleaned, and sectioned into rings in an organ bath containing calcium-free Krebs solution with dextran and EGTA. The rings were photographed in the no-load state and cut radially to obtain the zero-stress state. Equilibrium was awaited for 30 min and the specimens were photographed again. Circumferences, submucosa and muscle layer thicknesses and areas, and the opening angle were measured from the digitized images. The oesophagi in oim mice had smaller layer thicknesses and areas compared to the wild types. The largest reduction in layer thickness in oim mice was found in the submucosa (approximately 36%). Oim mice had significantly larger opening angles (120.2 +/- 4.5 degrees ) than wild-type mice (93.0 +/- 11.2 degrees ). The residual strain was compressive at the mucosal surface and tensile at the serosal surface in both oim and wild types. In the oim mice, the residual strains at the serosal and mucosal surfaces and the mucosa-submucosal-muscle layer interface were higher than in the wild types (P < 0.05). The gradient of residual strain per unit thickness was higher in oim mice than in wild-type mice, and was highest in submucosa (P < 0.05). The only morphometric measure that was similar in oim and wild-type mice was the inner circumference in the no-load state. In conclusion, our data show significant differences in the residual strain distribution and morphometry between oim mice and wild-type mice. The data suggest that the residual stress in oesophagus is caused by the tension in the muscle layer rather than the stiffness of the submucosa in compression and that the remodelling process in the oim oesophagus is due mainly to morphometric and biomechanical alterations in the submucosa.

Animals↗

Small intestine wall distribution of elastic stiffness measured with 500 MHz scanning acoustic microscopy.

Obtaining data relating intestinal mechanical properties and histology is a step towards the next level in the hierarchy of structure of living tissue, and may provide new insight into the mechanisms of intestinal function and disease such as obstruction. Due to lack of methodology, however, such data are currently sparse. Scanning acoustic microscopy (SAM) can measure the propagation speed of sound (C) and the acoustic impedance (Z) with micrometer resolution in tissue. By use of elementary theory of elasticity, the elastic stiffness (c11) can be computed from C and Z. We used 5-microm-thick transverse sections of ethanol treated guinea pig small intestine as the experimental model and measured the distribution of C and Z across the intestinal wall using SAM at 500 MHz. The individual layers mucosa, submucosa, and circular and longitudinal muscle were discerned with ease in the images and varied significantly with respect to both C and Z in most cases. The measured values (median values) of C ranged from 1550 to 1669 m s(-1), and Z ranged from 2.10 to 2.60 MPa s m(-1). c11 differed between all layers ranging from 3.25 to 4.27 GPa with the following sequence of magnitude: circular muscle >submucosa>mucosa>longitudinal muscle (p<0.001). In conclusion, we provided the first microscale mechanical data relating to the histological layers of the small intestine.

Acoustics↗

Remodeling of the zero-stress state of femoral arteries in response to flow overload.

The goal of this study is to quantitatively describe the remodeling of the zero-stress state of the femoral artery in flow overload. Increased blood flow, approximately as a unit step change, was imposed on the femoral artery by making an arteriovenous (a-v) fistula with the epigastric vein. The a-v fistula was created in the right leg of 36 rats, which were divided equally into six groups (2 days and 1, 2, 4, 8, and 12 wk after the fistula). The vessels in the left leg were used as controls without operative trauma. The in vivo blood pressure, flow, and femoral outer diameter and the in vitro zero-stress state geometry were measured. The in vivo shear rate at the endothelial surface increased approximately as a step function by approximately 83%, after 2 days, compared with the control artery. The arterial luminal and wall area significantly increased postsurgically from 0.15 +/- 0.02 and 0.22 +/- 0.02 mm(2) to 0.28 +/- 0.04 and 0.31 +/- 0.05 mm(2), respectively, after 12 wk. The wall thickness did not change significantly over time (P > 0.1). The opening angle decreased to 82 +/- 4.2 degrees postsurgically when compared with controls (102 +/- 4.4) after 12 wk and correlated linearly with the thickness-to-radius ratio. Histological analysis revealed vascular smooth muscle cell growth. The remodeling data are expressed mathematically in terms of indicial functions, i.e., change of a particular feature of a blood vessel in response to a unit step change of blood flow. The indicial function approach provides a quantitative description of the remodeling process in the blood vessel wall.

Animals↗

Sensory and biomechanical responses to distension of the normal human rectum and sigmoid colon.

BACKGROUND: Visceral pain is a major clinical problem. The aim of the present study was to compare the pain and biomechanical responses to standardized distension of the human colon. METHODS: The relation between pain intensity and pressure, cross-sectional area (CSA) and tension-strain relations of the rectum and sigmoid colon were studied in 11 normal subjects following standardized distension using impedance planimetry. The bag was inflated stepwise with pressures up to 6 kPa. The subjects, who were blinded for the distension procedure, rated their pain intensity using an aggregate visual analogue score (VAS) combining the intensity of the feeling of air, urge to defecate and pain. RESULTS: The distensions produced an initial rapid increase in CSA followed by a phase of slow increase until a steady state CSA was reached after 0.5-1 min. Several phasic contractions (observed as short-term decreases in the CSA) were recorded in the rectum from the end of the rapid phase to the end of distension at pressures from 1 to 5 kPa. The CSA in the rectum and sigmoid colon was 3,706 +/- 426 mm(2) and 2,305 +/- 426 mm(2) at the maximum bag pressure of 6 kPa (F = 52.4, p < 0.001). The tension-strain relation did not differ between the normal rectum and sigmoid colon. The VAS score for every modality (air, defecation and pain) revealed an increase in intensity as a function of pressure. The VAS score in the rectum and the sigmoid colon as a function of tension and strain did not show any differences. CONCLUSIONS: The biomechanical properties in the sigmoid colon and rectum were alike. For a given wall tension and circumferential strain the sensibility seems equal in the rectum and the sigmoid colon. The observed difference in perception between the two segments was related to the greater CSA in the rectum.

Abdominal Pain↗

The impact of M-component type and immunoglobulin concentration on the risk of malignant transformation in patients with monoclonal gammopathy of undetermined significance.

BACKGROUND AND OBJECTIVES: In this study the impact of gender, age, type of M-component and concentration of immunoglobulins on the risk of malignant transformation in monoclonal gammopathy of undetermined significance (MGUS) was assessed. DESIGN AND METHODS: We identified 1,247 cases of MGUS in the period 1978 to 1993 in North Jutland County, Denmark. Data on cancer occurrence in the MGUS cohort were obtained from the Danish Cancer Registry. The expected numbers of incident cancer cases were calculated from age-, sex-, county-, and period-specific cancer incidence rates. The impact of the variables mentioned above on the risk of malignant transformation was analyzed in Poisson regression models. RESULTS: The relative risk of IgA compared to IgG was 1.8 (95% confidence interval, 1.1-3.0), while the relative risk of IgM compared to IgG was 1.1 (0.7-1.9). For all three types of MGUS, the risk of malignant transformation was higher among females than among males, and the risk increased with increasing concentration of immunoglobulin with very high risks for the patients with the highest levels of immunoglobulin. Hypogammaglobulinemia was associated with malignant transformation in patients with IgG type MGUS. For IgG and IgM MGUS, the risk decreased with increasing age and with follow-up beyond one year. INTERPRETATION AND CONCLUSIONS: Female sex, IgA M-component type and high concentration of the immunoglobulin comprising the M-component were associated with a high risk of malignant transformation. Hypogammaglobulinemia, young age at diagnosis and short follow-up were risk factors in particular for those with IgG MGUS.

Adolescent↗

Multiple myeloma following an episode of community-acquired pneumococcal bacteraemia or meningitis.

The risk of multiple myeloma subsequent to an episode of serious pneumococcal infection has not been ascertained. We identified 328 episodes of community-acquired pneumococcal bacteraemia and 77 episodes of pneumococcal meningitis in 227,000 persons over 40 years of age in the County of North Jutland, Denmark, in the period 1981 to 1996. The incidence rate of a subsequent diagnosis of multiple myeloma was determined by linkage to the Danish Cancer Registry. During 1,218 patient-years of follow-up in the bacteraemia cohort, 7 cases of multiple myeloma were diagnosed compared with 0.13 cases expected (standardized incidence ratio (SIR) 53.5, 95% confidence interval 21.4-111.4). During 444 patient-years of follow-up in the meningitis cohort, 4 cases of multiple myeloma were diagnosed compared with 0.05 cases expected (SIR 83.2, 95% confidence interval 22.6-214.8). Patients who survive an episode of community-acquired pneumococcal bacteraemia or meningitis are at increased risk of being diagnosed with multiple myeloma, but the absolute risk is low.

Adult↗

[Improved function of the hand in persons with tetraplegia using electric stimulation via implanted electrodes].

Functional Electrical Stimulation (FES) is a controlled use of electrical stimulation of muscle contractions to obtain function. FES is utilised today in the treatment of spinal cord injured individuals for diaphragmatic pacing, bladder and bowel management, ejaculation, walking and hand function, as well as conditioning. We present The Freehand System, which consists of implanted electrodes to arm and hand muscles. This system has now been implanted in the first two Nordic tetraplegics. Candidates are tetraplegics with C5-6 lesions. After implantation it may take 6-8 months before the tetraplegic person can expect to use The Freehand System completely in daily life. The tetraplegic individual can choose between two grasps. The Freehand System can for some few very physically disabled tetraplegics be a good aid to increase their level of activities of daily living and independence. Continued development in the coming years may broaden the indications with benefit for more individuals.

Activities of Daily Living↗

Vascular reactivity to nifedipine and Ca(2+) in vitro: the role of preactivation, wall tension and geometry.

The purpose of the study was to investigate the influence of preactivation, wall tension and geometry on the reactivity of porcine coronary arteries to nifedipine and extracellular Ca(2+) in vitro. Porcine large coronary arteries were mounted as ring and cylindrical preparations and studied by wire- and balloon-based techniques. The sensitivity and maximal responses to nifedipine were more pronounced in 25 mM K(+) compared to 10 microM prostaglandin F(2alpha)-contracted preparations. Vascular sensitivity to nifedipine and Ca(2+) was enhanced under isometric compared to isobaric conditions. Under isometric conditions in the presence of 25 mM K(+), coronary rings were more sensitive to nifedipine, but less sensitive to Ca(2+) compared to cylindrical segments. In cylindrical segments, circumferential and axial tension increases augmented the extracellular Ca(2+)-dependent spontaneous resting tone and the sensitivity to extracellular Ca(2+). Coronary rings showed no resting tone at various resting tensions. These results suggest that preactivation, wall tension and vessel geometry are important determinants of Ca(2+)-influxes via nifedipine-sensitive voltage-gated Ca(2+) channels. Furthermore, axial wall tension appears to be a modulator of nifedipine-insensitive transmembrane Ca(2+)-influx that may play a role for the tone and reactivity in large coronary arteries.

Animals↗

Cancer risk in patients with monoclonal gammopathy of undetermined significance.

To assess the cancer risk of monoclonal gammopathy of undetermined significance (MGUS) we identified 1229 cases of MGUS in the period 1978 to 1993. Data on cancer occurrence in the MGUS cohort were obtained from the Danish Cancer Registry. The expected numbers of cancer cases were calculated from age-, sex-, county-, and period-specific cancer incidence rates. In the MGUS cohort 64 new cancers with a known association with M-components were diagnosed versus 5.0 expected giving a standardized incidence ratio (SIR) of 12.9 (95% confidence interval, 9.9-16.5). The relative risks of developing multiple myeloma (SIR 34.3), Waldenström's macroglobulinemia (SIR 63.8), and non-Hodgkin's lymphoma (SIR 5.9) were significantly increased and independent of time passed from detection of the M-component. The relative risk of chronic lymphocytic leukemia was not significantly increased, SIR 2.7 (0.5-7. 7). Among cancer sites without known association with M-components 141 cases were observed versus 94.6 expected giving a SIR of 1.5 (1. 3-1.8). This enhanced risk was seen for several non-hematological cancer sites but for most cancer sites the risk was dependent on time passed from detection of the M-component, indicating a bias rather than a causal role of MGUS.

Adolescent↗