Development of a tensostat for gastric perception studies.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to H Gregersen.
Explore the source record for details and available documents.
Intestinal stress-strain distributions are important determinants of intestinal function and are determined by the mechanical properties of the intestinal wall, the physiological loading conditions and the zero-stress state of the intestine. In this study the distribution of morphometric measures, residual circumferential strains and stress-strain relationships along the rat large intestine were determined in vitro. Segments from four parts of the large intestine were excised, closed at both ends, and inflated with pressures up to 2kPa. The outer diameter and length were measured. The zero-stress state was obtained by cutting rings of large intestine radially. The geometric configuration at the zero-stress state is of fundamental importance because it is the basic state with respect to which the physical stresses and strains are defined. The outer and inner circumferences, wall thickness and opening angle were measured from digitised images. Subsequently, residual strain and stress-strain distributions were calculated. The wall thickness and wall thickness-to-circumference ratio increased in the distal direction. The opening angle varied between approximately 40 and approximately 125 degrees with the highest values in the beginning of proximal colon (F=1.739, P<0.05). The residual strain at the inner surface was negative indicating that the mucosa-submucosal layers of the large intestine in no-load state are in compression. The four segments showed stress-strain distributions that were exponential. All segments were stiffer in longitudinal direction than in the circumferential direction (P<0.05). The transverse colon seemed stiffest both in the circumferential and longitudinal directions. In conclusion, significant variations were found in morphometric and biomechanical properties along the large intestine. The circumferential residual strains and passive elastic properties must be taken into account in studies of physiological problems in which the stress and strain are important, e.g. large intestinal bolus transport function.
Impedance planimetry and high-frequency ultrasound were used to determine circumferential stress and strain from measurements of luminal cross-sectional area and wall thickness during balloon distension of the guinea pig esophagus in vitro (N = 30). The excised esophagus was mounted on two plastic tubes in an organ bath containing oxygenated calcium-free Krebs-Ringer solution with 10(-2) M MgCl2 to abolish smooth muscle contractile activity. One of the plastic tubes was movable in order to stretch the esophagus longitudinally by 15% (elongated state). The impedance planimetry probe was placed with the balloon inside the lumen of the esophagus. A 20-MHz ultrasound transducer was mounted above the esophagus and provided scans in the transverse and longitudinal directions. The luminal cross-sectional area at the highest applied pressure of 2.9 kPa was 13.3 +/- 0.3 mm2 in the resting state. In the elongated state the luminal cross-sectional area at the highest pressure was 12.5 +/- 0.1 mm2 (P < 0.02). The wall thickness decreased from 990 +/- 21 microm at 0 kPa to 640 +/- 9 microm at 2.9 kPa at in vitro length. In the elongated state, the values were 940 +/- 32 microm to 480 +/- 13 microm (P < 0.01). The stress-strain relation was exponential (sigma = alpha(ebetaepsilon - 1), r2 > 0.98, P < 0.01). The circumferential elastic modulus calculated at a Green strain of 0.95 was 44.5 +/- 10.5 kPa in the in vitro state and 81.7 +/- 13.1 kPa in the elongated state. The elastic modulus differed between the resting and elongated states (P < 0.02).
The morphometry at no-load and zero-stress states and residual circumferential strains were determined along the pig duodenum in vitro in seven pigs. The no-load state was obtained by cutting eleven 2-mm-wide rings at 10% intervals along the duodenum. The zero-stress state was obtained by cutting the rings radially. The zero-stress state provides a standard morphological state to describe tissue since internal and external forces do not affect the tissue. The morphometric measures were obtained from digitized images, and the layer thicknesses were measured from histological sections. The mucosal and serosal circumferences, the wall thickness, and the wall thickness-to-mucosal radius ratio were largest in the proximal end of the duodenum (f > 1.9, P < 0.05). The thickness of the submucosal stratum compactum layer and the opening angle increased in distal direction (f = 2.3, P < 0.05 and = 6.5, P < 0.001). The residual strain at the mucosal surface was negative, indicating that the mucosa-submucosa layers of duodenum in no-load state are in compression. Distension experiments showed that the residual strain makes the stress distribution through the wall more uniform in the pressurized state. In conclusion, the large circumferential residual strains must be taken into account in the study of physiological problems, in which the stresses and strains are important, eg, the bolus transport function.
The stresses and strains that remain in an organ when the external load is removed (the no-load state) are called residual stresses and strains. They can be relieved by cutting up the organ to obtain the zero-stress configuration. This phenomenon was demonstrated more than 15 years ago in cardiovascular research but until recently it was not realized by the gastrointestinal research community. The function of the gastrointestinal tract is to propel food by peristaltic motion, which is a result of the interaction of the tissue forces in the wall and the hydrodynamic forces in the food bolus. To understand the tissue forces, it is necessary to know the stress-strain relationships of the tissues that must be measured in reference to the zero-stress state. It has become clear that the zero-stress configuration of the gastrointestinal tract is very different from that of the no-load condition and that the zero-stress state is sensitive to structural and mechanical remodeling. The purpose of this review is to describe the basic theory and experiments of residual stress and to explore its physiological and pathophysiological implications in the gastrointestinal system.
Explore the source record for details and available documents.
Morphometric and passive biomechanical properties were studied in isolated segments of the thoracic and abdominal aorta, left common carotid artery, left femoral artery and the left pulmonary artery in 20 non-diabetic and 28 streptozotocin (STZ)-induced diabetic rats. The diabetic and non-diabetic rats were divided into groups living 1, 4, 8, and 12 weeks after the induction of diabetes (n = 7 for each diabetic group) or sham injection (n = 5 for each group). The mechanical test was performed as a distension experiment where the proximal end of the arterial segment was connected via a tube to the container used for applying pressures to the segment and the distal end was left free. The vessel diameter and length were obtained from digitized images of the arterial segments at pre-selected pressures and at no-load and zero-stress states. Circumferential and longitudinal stresses (force per area) and strains (deformation) were computed from the length, diameter and pressure data and from the zero-stress state data. The zero-stress state was obtained by cutting vessel rings radially causing the rings to open up into a sector. Diabetes was associated with pronounced morphometric changes, e.g., wall thickness. With respect to the biomechanical data, the opening angle increased and reached a plateau in 4 weeks after which it decreased again (p < 0.05). The opening angle was smallest in the thoracic aorta and largest in the pulmonary artery. Furthermore, it was found that the circumferential stiffness of the arteries studied increased with the duration of diabetes. In the longitudinal direction significant differences were found 8 weeks after injection of STZ in all arteries except the pulmonary artery. In the 12 weeks group, the femoral artery was stiffest in the circumferential direction whereas the thoracic aorta was stiffest in the longitudinal direction. The accumulated serum glucose level correlated with the arterial wall thickness and elastic modulus (correlation coefficient between 0.56 and 0.81).
A computer-controlled tensiometer for studying wall tension in tubular organs has been developed. The system consisted of a probe with an inflatable balloon, an impedance planimeter, pressure transducer and amplifier, a pump with RS232 interface and a PC with dedicated software. Circumferential wall tension was computed in real time from pressure and cross-sectional area measurements (tension measurement mode). Wall tension can be maintained on a preset level or be changed as a step or ramp function by a feedback control of the infusion/withdrawal pump (tension control mode). A software regulator adjusted the volume rate (low volume rate when the computed tension was close to the preset value) to minimize overshoot and oscillation. Validation tests were performed and the technique was applied in the human oesophagus. Volume- and tension-controlled balloon distensions elicited secondary peristalsis of increasing intensity that was decreased significantly by the antimuscarinic agent Hyoscine butyl bromide. In tension control mode Hyoscine butyl bromide caused oesophageal relaxation, i.e. CSA to increase and pressure to decay. Furthermore, pronounced pressure relaxation and tension relaxation were observed during volume-controlled distension after administration of Hyoscine butyl bromide.
Recent studies on blood vessels, the heart, trachea and esophagus have shown that these organs in the zero-stress state are not closed circular cross-sections of rings, but open sectors. Any analysis of stress and strain must begin with organs in the zero-stress state. This report presents data on morphometry of the zero-stress and no-load states of the porcine ureter, and on residual strains and opening angles. The zero-stress state of the ureter is demonstrated by cutting the ureter into rings and cutting the rings into sectors; each sector is characterized by an opening angle. The outer and inner circumferences, the cross-sectional area of the ureteral wall and the number of buckles showed axial variation, with the highest values proximally in the ureter. Residual strain in the circumferential direction was significant, but showed no axial variation. The opening angles were approximately 30 degrees at the most distal and proximal sites and approximately 90 degrees in mid-ureter. The opening angle showed positive correlation to the wall thickness in the zero-stress state, residual strain at the outer circumference and negative correlation to the length of the outer circumference in the zero-stress state. Residual strains must be taken into account when studying physiological problems in which the stresses and strains are important, e.g. the urine transport function of the ureter.
The function of the esophagus is to move food by peristaltic motion, which is the result of the interaction of the tissue forces in the esophageal wall and the hydrodynamic forces in the food bolus. To understand the tissue forces in the esophagus, it is necessary to know the zero-stress state of the esophagus, and the stress-strain relationships of the tissues. This article is addressed to the first topic: the representation of zero-stress state of the esophagus by the states of zero stress-resultant and zero bending moment of the mucosa-submucosa and the muscle layers. It is shown that at the states of zero stress-resultant and zero bending moment, these two layers are not tubes of smaller radii but are open sectors whose shapes are approximately cylindrical and more or less circular. When the sectors are approximated by circular sectors, we measured their radii, opening angles, and average thickness around the circumference. Data on the radii, thickness-to-radius ratios, and the opening angles of these sectors are presented. Knowing the zero-stress state of these two layers, we can compute the strain distribution in the wall at any in vivo state, as well as the residual strain in the esophageal wall at the no-load state. The results of the in vivo states are compared to those obtained by a conventional approach, which treats the esophageal wall as a homogeneous material, and to another popular simplification, which ignores the residual strains completely. It is shown that the errors caused by the homogeneous wall assumption are relatively minor, but those caused by ignoring the residual strains completely are severe.
Previous studies have demonstrated regional differences in pressure-cross-sectional area relations, compliance and tension-strain relations of the oesophagus in vivo. The measurements and the variation in axial direction may reflect not only intrinsic oesophageal properties but can also be influenced by the adjacent organs. Four pigs were thoracotomised and the oesophagus was isolated from adjacent organs. The isolated oesophagus was investigated in situ by means of impedance planimetric measurements of cross-sectional area during pressure-controlled balloon distension 5, 15, and 25cm proximal to the gastro-oesophageal junction. CSA increased in a nonlinear way as function of pressure at all recording sites. The CSAs at pressures above 20 cmH2O increased progressively in distal direction (p < 0.001). The CSAs at a physiological pressure level of 30 cmH2O were 197 +/- 10, 222 +/- 19, and 231 +/- 17 mm2 at 25, 15, and 5cm above the gastro-oesophageal junction, respectively. The cross-sectional area distensibility increased from the proximal to the distal recording site in the whole pressure range (p < 0.001) with the most pronounced difference in the low pressure range. In conclusion, the regional variation in passive distensibility of the porcine oesophagus is an inherent condition of the oesophageal wall. The data have significance for evaluation of oesophageal flow properties and agree with previous findings of slow bolus velocity in the distal oesophagus.
BACKGROUND: The aim of the study was to evaluate whether the sensitivity for distension-induced contractions in the duodenum varied with the phases of the interdigestive migrating motility complex (MMC). METHODS: Four beagles (12-17 kg) with gastric fistulas were studied by means of perfused low-compliance manometry. A 2.5-cm-long balloon was placed in the third part of the duodenum. Side holes for pressure measurements were placed inside the balloon, 2cm proximal to the balloon, and in the antrum. Two-minute distensions with balloon pressures of 10 cmH2O were repeated in 10-min intervals during 17 MMCs. Twelve MMCs were also recorded without doing distensions. RESULTS: Balloon distension did not affect the duration of phase III and the MMC. In the beginning of phase I, distension did not significantly affect duodenal motility whereas distension induced contractile responses in late phase I, early phase II and late phase II (p < 0.05). The highest increase from the pre-distension to distension period was observed in early phase II (average 4 contractions min(-1)). However, considering the level of pre-distension contraction frequency, the fractional increase was by far the highest in late phase I. In phase III no difference was found between the periods before and during distension (15.8 +/- 0.7 versus 15.8 +/- 0.5 contractions min(-1)). The effect of balloon distension in phase IV was difficult to evaluate due to the inconsistent nature and sometimes rapidly decreasing activity in phase IV. Duodenal distension did not change frequency and amplitude of antral phase II contractions (p > 0.5). CONCLUSIONS: Duodenal balloon distension elicited ascending contractions in the canine duodenum in late phase I and in phase II. A refractory phase was demonstrated in the beginning of phase I while in phase III the frequency of contraction could not be increased further.
The dose- and time-dependent effects of endoscopic sclerotherapy on luminal cross-sectional area and wall distensibility were studied in pigs at 5 and 12 cm proximal to the gastroesophageal junction by means of impedance planimetry. Sixteen healthy animals underwent two sessions of endoscopic sclerotherapy two weeks apart with injections of either 5 or 10 ml of 1% Polidocanol in the distal 7 cm of the esophagus each time. The animals were investigated before sclerotherapy, two weeks after each session, and finally six weeks after the last session. Six healthy animals were studied as controls. Endoscopic sclerotherapy caused luminal narrowing in the sclerosed zone followed by normalization six weeks after the last treatment (P < 0.05 in both groups). Wall distensibility decreased in the sclerosed zone after treatment with 10 ml sclerosant (P < 0.05) followed by partial normalization, while no effect was found after 5 ml sclerosant (P > 0.2). Progressive dilations were observed in the proximal esophagus in both groups and were most pronounced in the 10 ml group (P < 0.05). Wall distensibility did not change proximal to the site of sclerotherapy in either group (P > 0.1).
We compared the stress-strain distributions obtained from isolated segments of the guinea pig duodenum, jejunum, and distal ileum, and the relation between the elastic properties and the collagen content. The segments were immersed in Krebs-Ringer solution containing 10(-2) M MgCl2 to abolish contractile activity. Stepwise inflation of an intraluminal balloon in which the cross-sectional area (CSA) was measured provided the luminal pressure-loading stimulus. The wall thickness was measured by means of 20-MHz A-mode ultrasound. The stress-strain and the incremental elastic modulus-strain distributions were derived from the steady-state values of wall thickness, internal radius, and applied pressure. The CSA-pressure relations and the wall thickness-pressure relations were nonlinear and both differed between the segments (P < 0.01). The stress-strain distributions showed an exponential behavior that fitted well to the equation Y = a x Exp(b x X) (r2 = 0.97 +/- 0.01). The intercept with they axis (a) and the slope of the curves (b) differed between the segments (P < 0.01 and P < 0.05). The collagen contents were 3.99 +/- 0.18 microg/mg, 2.51 +/- 0.13 microg/mg, and 2.10 +/- 0.11 microg/mg in the duodenum, jejunum, and distal ileum, respectively. This difference was significant among all three locations (P > 0.05). An association was found between the collagen content and the incremental elastic modulus (stiffness) at a stress level of 70 kPa (P < 0.05).
Explore the source record for details and available documents.
The bile duct is a distensible tube serving to transport bile from the liver and gallbladder to the duodenum. The purpose of this study was to characterize the luminal cross-sectional area (CSA) and tension-strain properties during distension of the normal isolated porcine common bile duct in vitro. An impedance planimetric system located inside a balloon was used. Eleven porcine bile ducts were examined in two locations, in the hepatic duct and in the common bile duct. The CSAs obtained in the common bile duct were significantly higher than those in the hepatic duct in the pressure range 0-8 kPa (P < 0.001). The circumferential wall tension (T)-strain (epsilon) relations for both locations fitted to the exponential equation T = a.eb. epsilon with determination coefficients of 0.97 +/- 0.01. The a and b constants were not statistically different between the two locations indicating that the elastic properties did not differ. In conclusion, the luminal CSAs were larger in the common bile duct when compared to the hepatic duct and the tension-strain relations did not differ between the two segments of the bile duct.
1. The principal aim of the present study was to explore the isometric and isobaric capacity of a new intravascular technique, impedance planimetry, in basic pharmacodynamic investigations on porcine isolated epicardial coronary arteries. 2. The balloon-based catheter technique provides simultaneous measurements of luminal cross-sectional area and pressure. Sources of errors that may influence the accuracy of measurements were evaluated in detail. 3. Under isometric conditions, the stretch ratio-tension diagram showed typical developments of resting and active tensions of the smooth muscle when exposed to alternating maximal K+ depolarization and mechanical stretching. The mean (+/- SEM) maximum active tension was 28.43 +/- 1.72 mN/mm, which was reached at a stretch ratio of 1.26 +/- 0.02, corresponding to a resting tension of 10.50 +/- 0.53 mN/mm (n = 7). The concentration-response relationship to K+ at optimal basal tension was characterized by a mean (+/- SEM) pD2 value of 1.67 +/- 0.01 (n = 7). 4. Under isobaric conditions in the pressure range 40-140 mmHg, the method allowed the investigation of active vascular responses to partial K+ depolarization. The maximal active response to 25 mmol/L K+ was found at the transmural pressure of 60 mmHg (n = 7). To obtain full K+ concentration-response curves, a basal tension corresponding to a transmural pressure of 120 mmHg was required. The mean (+/- SEM) pD2 value for the concentration-response relationship to K+ was 1.53 +/- 0.01 (n = 10). 5. The vascular sensitivities to cumulatively added K+ and various agonists, such as acetylcholine, 5-hydroxytryptamine and noradrenaline, obtained from the same vessel segment at the same initial conditions corresponding to 120 mmHg were significantly higher with the isometric than with the isobaric approach. 6. The results of the present study suggest that impedance planimetry could be a useful tool in pharmacological and physiological investigations of medium-sized arteries, both under isometric and isobaric conditions.