PubMed Health⌕ Search

Biomedical subjects

H Gregersen

Publications and source records attributed to H Gregersen.

At least 91 records · Page 5Linked to original sources

The risk of bacteremia in patients with monoclonal gammopathy of undetermined significance.

We estimated the risk of bacteremia in patients with monoclonal gammopathy of undetermined significance (MGUS) compared with the general population; 1237 cases of MGUS were identified by linking information on detected monoclonal components in the North Jutland County with the Danish Cancer Registry. We evaluated the risk of bacteremia in the MGUS cohort during the 13-yr period from 1981 to 1993 by linkage to the Bacteremia Registry in the County. Follow-up for the occurrence of bacteremia started 30 d after detection of the M-component and continued until malignant transformation, death or until 31 December 1993, whichever came first. The expected numbers of bacteremia was based upon county, age, sex and period-specific incidence rates. The median follow-up period was 3.8 yr. Forty episodes of bacteremia occurred during 5500 person-years versus 18 expected. The crude standardized incidence ratio of bacteremia was 2.2 (95% confidence interval, 1.6-3.0). There was no distinct pattern of bacterial etiology in the MGUS cohort. Although we found an association between MGUS and risk of bacteremia, the overall risk is small and this finding hardly affects the clinical handling of MGUS patients.

Aged↗

Relation between zero-stress state and branching order of porcine left coronary arterial tree.

The left common coronary arterial trees of eight pig hearts were dissected. The zero-stress state (the state of the organ when the external loads are removed) of the coronary arteries was determined by first cutting the arteries into short, ring-shaped segments perpendicular to the longitudinal axis of the blood vessel and then making a radial cut. This procedure caused the ring to open into a sector whose opening angle (theta), internal and external lengths (circumferences), and wall thickness were measured. Morphometric and theta data were organized in the framework of a diameter-defined Strahler system. We investigated 4 rings from the left common coronary artery (LCCA), 185 from the left anterior descending artery (LAD) and its branches, and 159 from the left circumflex artery (LCX) and its branches. The inner circumferences of the rings ranged over six orders for the LAD arterial tree and five orders for the LCX arterial tree, corresponding to a diameter range of about one order of magnitude for both arteries. theta demonstrates viscoelastic behavior and was measured 30 min after cutting. Our results show that the inner and outer circumference and the wall thickness increase as geometric sequences with the order number. theta is found to decrease linearly toward the smaller orders with a slope of 7.3 degrees/order in the range of the six largest orders. Strain calculations showed that the inner part of the arterial wall is in compression, whereas the outer part of the wall is in tension in the no-load (zero transmural pressure) state. This study provides basic data on the zero-stress state that are necessary for understanding the mechanics of the coronary artery.

Animals↗

Third generation oral contraceptives and heritable thrombophilia as risk factors of non-fatal venous thromboembolism.

Third generation oral contraceptives (OCs) are apparently stronger risk factors for venous thromboembolism (VTE) than other OCs, however, the increased risk may be due to confounding by indication related to differences in prescription behaviour. We estimated the risk of VTE associated with use of OCs with and without the presence of Factor V Leiden mutation, protein C-, protein S- or antithrombin deficiency. Sixty-seven cases with VTE were compared with 134 controls. The risk of VTE in the presence of thrombophilia was of the same magnitude for third generation OC users as for users of other OCs; OR: 52.5 (95% CI: 3.7-738.1) and OR: 63.3 (95% CI: 6.2-648.4), respectively. It is unlikely that confounding by indication entirely explains the risk of VTE associated with third generation OCs since the combined effect exceeds what could be explained if this source of error was the only determinant of the association.

Adult↗

[Renal insufficiency in myelomatosis. Prognostic factors and survival].

Clinical features, occurrence and reversibility of renal failure, response to treatment and survival duration in 190 multiple myeloma patients were reviewed in a retrospective study based on hospital records. Renal failure was present in 27% of the patients and constituted an important prognostic factor. Reversibility of renal failure occurred in 52% of the patients and was more frequent in those with low serum creatinine, hypercalcaemia, high erythrocyte sedimentation rate and high level of IgA. Response to chemotherapy resulted in a prolonged survival, whereas recovery of renal function did not significantly affect survival.

Adult↗

Dimensions and mechanical properties of porcine aortic segments determined by combined impedance planimetry and high-frequency ultrasound.

The aim of the study is to devise a method for direct measurements of pressure, cross-sectional area (CSA) and wall thickness of a vessel when pressurised. Segments of porcine descending thoracic aorta from 22 and 35 kg pigs (in groups 1 and 2, respectively) and of abdominal aorta from 35 kg pigs are studied in vitro. Impedance planimetry provides measurements of the luminal pressure and CSA of the aorta. The wall thickness is measured simultaneously by means of 20 MHz A-mode ultrasound. The pressure, CSA and wall thickness are registered at different pressure at steady state. At maximum pressure, the CSAs are 107 +/- 10, 215 +/- 19 and 257 +/- 17 mm2 in the abdominal, group 1 and 2 segments, respectively. There is a difference between the abdominal group and groups 1 and 2 (p < 0.05), but not between group 1 and 2 segments (p > 0.2). At maximum pressure, the wall thickness is 0.52 +/- 0.04, 0.79 +/- 0.07 and 1.07 +/- 0.02 mm, in the abdominal group 1 and 2 segments, respectively (p < 0.05). The circumferential stress-strain relationship accorded well with stress = a x exp(b x strain). The stress-strain curve of the abdominal aortas is shifted to the left, indicating an increase (p < 0.05).

Animals↗

Static elastic wall properties of the abdominal porcine aorta in vitro and in vivo.

OBJECTIVES: To characterise possible differences in vascular mechanics between in vitro and in vivo settings. DESIGN: Experimental animal study. MATERIAL: Segments of abdominal aorta from five 30kg pigs were studied in vitro and five porcine abdominal aortas were investigated in vivo. METHODS: Vessel luminal cross-sectional area (CSA) was assessed in vitro and in vivo by measuring the electrical impedance of fluid inside a distensible balloon mounted on a catheter. Wall thickness was measured in vitro by means of 20 MHz A-mode ultrasound. The obtained values in vitro were used to calculate wall thickness in vivo. RESULTS: The CSAs were larger in vitro than in vivo (p < 0.05). All segments showed stress-strain relations that accorded well with the exponential equation: Stress = a.exp(b. Strain). The y-axis intercepts (a) and the slope of the curves (b) were different in vitro and in vivo (p < 0.05). Differences were found between the aorta in vivo and in vitro regarding the circumferential stress-strain relations, i.e. the stiffest abdominal aorta was found in vivo. CONCLUSIONS: The differences in dimensions and wall stiffness may be attributed to the tethering to the surrounding tissues in vivo. Impedance planimetry combined with high frequency ultrasound is an accurate way of measuring segmental vascular elasticity in vivo.

Animals↗

Impedance planimetric characterization of esophagus in systemic sclerosis patients with severe involvement of esophagus.

This study was designed to evaluate the distensibility and secondary peristalsis of the esophagus in patients suffering from systemic sclerosis with severe esophageal involvement. Balloon distension with impedance planimetric measurement of luminal cross-sectional area was done 7 and 15 cm above the lower esophageal sphincter in 13 patients and nine healthy controls. The controls were studied both with and without receiving the anticholinergic drug butylscopolamine. The cross-sectional area--pressure relations were nonlinear with the largest cross-sectional area in patients at both measuring sites when compared to controls (P < 0.001). The anticholinergic drug butylscopolamine increased the cross-sectional area in controls (P < 0.001). The cross-sectional area distensibility, defined as CSA0(-1) delta CSA delta P-1 did not differ between patients and controls. Balloon distensions elicited contractions proximal to the distension site. The amplitude and frequency of contractions at the distal distension site were significantly reduced in the patients when compared to the controls (P < 0.05). In conclusion, the distal esophagus is most severely affected in patients with systemic sclerosis with increased cross-sectional area and impaired peristalsis.

Adult↗

Impaired human coronary artery distensibility by atherosclerotic lesions: a mechanical and histological investigation.

The objective of this study was to evaluate the relationship between human coronary artery distensibility and vessel wall morphology assessed by histomorphometry. Coronary artery pressure-cross-sectional area relations and distensibility were studied in excised autopsy hearts by means of a balloon-based impedance planimetric technique 2 cm from the aortic orifice of the arteries. Later the hearts were perfusion fixed at 100 mm Hg and cross-sectioned 17, 20 and 23 mm distal to the aortic orifice. The areas of lumen, intima and media were measured. Nineteen left anterior descending coronary arteries (LAD) and 15 right coronary arteries (RCA) from 25 hearts (12 women and 13 men) were investigated. The age of the subjects was 48-97 years (mean 73.8 years). Non-linear relations were found between balloon pressure and coronary cross-sectional area (according with the function y = a + bx0.5) and between balloon pressure and coronary distensibility, but there were no differences in these relations between the LAD and RCA. Subjects' age was positively correlated with wall thickness (r = 0.44, P < 0.05), intima area (r = 0.46, P < 0.01) and media area (r = 0.44, P < 0.05) of the coronary arteries. Additionally, the distensibility at low pressures was inversely correlated with arterial wall thickness (r = -0.37, P < 0.05). When focusing only on arteries with concentric atherosclerotic lesions, distensibility at low pressures was inversely correlated with arterial wall thickness (r = -0.57, P = 0.01) and intima area (r = -0.53, P < 0.05). Arteries with concentric lesions were less distensible at low pressures compared with arteries having eccentric lesions (5.4 +/- 0.8.10(-2) vs. 3.6 +/- 0.7.10(-2) kPa-1, P < 0.05) but this difference was absent at higher pressures. No difference in coronary artery distensibility was found between men and women. Age and distensibility were not correlated. These findings may have in vivo implications for complications to angioplasty procedures such as recoil and restenosis.

Aged↗

Morphometry and strain distribution in guinea pig duodenum with reference to the zero-stress state.

The aim of the present study is to determine the distribution of residual circumferential strains along the duodenum in anesthetized guinea pigs. A silicone elastomer was allowed to harden in the duodenal lumen under a pressure of 0.7 kPa. The duodenum was excised with the cast and photographed. The zero-stress state was obtained by cutting rings of duodenum radially. The geometric configuration at the zero-stress state is of fundamental importance, because it is the basic state with respect to which the physical stresses and strains are defined. A basic piece of information is the way the tangent vector rotates from one end of the circumference to the other. In the duodenum at zero-stress state, the total rotation of the tangent from one tip to the other is -500 to -850 , with the lowest absolute value in the proximal duodenum. In other words, the duodenum usually turns itself inside out on changing from a loaded state to the zero-stress state. The serosal circumference, the duodenal wall thickness, and the ratio of wall thickness to mucosal circumference decreased in the distal direction. In the pressurized state, the serosal Cauchy strain was tensile and increased in the distal direction; the mucosal Cauchy strain was compressive in the proximal half of the duodenum and tensile in the distal half. The large circumferential residual strains must be taken into account in a study of physiological problems in which the stresses and strains are important, e.g., the bolus transport function.

Animals↗

[Acute porphyria and multiple organ failure during treatment with lamotrigine].

A 38-year-old female suffered from an acute porphyric attack, multi-organ failure and disseminated intravascular coagulation (DIC) within two weeks of starting lamotrigine, a new antiepileptic drug. The porphyric attack was characterized by excess urinary excretion of aminolevulinic acid (ALA), porphobilinogen (PBG) and coproporphyrin III, a pattern similar to that seen in hereditary coproporphyria, however the diagnostic criteria for this specific porphyria were not fulfilled. We suggest that the observed clinical picture represents a rare adverse reaction to lamotrigine.

Adult↗

Unexplained chest pain: the hypersensitive, hyperreactive, and poorly compliant esophagus.

OBJECTIVE: To determine whether neuromuscular dysfunction of the esophagus causes chest pain in patients in whom no disease is found on cardiac work-up, upper gastrointestinal endoscopy, esophageal manometry, and 24-hour pH studies. DESIGN: Prospective study. SETTING: Tertiary referral center. PATIENTS: 24 consecutive patients and 12 healthy controls. MEASUREMENTS: A new technique, impedance planimetry, was used to measure the sensory, motor, and biomechanical properties of the human esophagus. The impendance planimeter, which consists of a probe with four ring electrodes, three pressure sensors, and a balloon, simultaneously measures intraluminal pressure and cross-sectional areas. This allows calculation of the biomechanical variables of the esophageal wall. RESULTS: Stepwise balloon distentions from 5 to 50 cm H2O induced a first sensation at a mean pressure (+/- SD) of 15 +/- 9 cm H2O in patients and 30 +/- 11 cm H2O in controls (P < 0.001). Moderate discomfort and pain were reported by 20 of 24 patients (83%) at 26 +/- 9 cm H2O and at 36 +/- 9 cm H2O, respectively, but by none of the controls (P < 0.001). Typical chest pain was reproduced in 20 of 24 patients (83%). In patients, the reactivity of the esophagus to balloon distention was greater (P = 0.01), the pressure elastic modulus was higher (P = 0.02), and the tension-strain association showed that the esophageal wall was less distensible (P = 0.02). Distention excited tertiary contractions and secondary peristalsis at a lower threshold of pressure (P = 0.05) and with a higher motility index in patients than in controls (P = 0.04). CONCLUSION: In patients with chest pain and normal cardiac and esophageal evaluations, impedance planimetry of the esophagus reproduces pain and is associated with a 50% lower sensory threshold for pain, a 50% lower threshold for reactive contractions, and reduced esophageal compliance.

Adult↗

Systemic treatment with epidermal growth factor in the rat. Biomechanical properties of the growing small intestine.

Prolonged treatment with epidermal growth factor (EGF) in the rat provides an experimental model to growth of the gastrointestinal tract. We treated female Wistar rats for 0 (n = 15), 1 (n = 8), 2 (n = 8), and 4 (n = 8) weeks with subcutaneous EGF (i50 micrograms.kg-1.day-1). Segments were taken from locations at 10, 50 and 90% along the length of the small intestine, weighed, the wall thickness was measured and the luminal cross-sectional area and passive biomechanical properties were assessed using impedance planimetry. In addition, the wall composition was evaluated on histological sections. The weight of the total small intestine and of the three segments (measured in mg.cm-1) increased with the duration of the EGF treatment due to mucosal and muscular growth. After 1 week of treatment the wall thickness increased. After 2 weeks of treatment the cross-sectional area began to increase. The circumferential stress-strain distributions revealed translation of the curves to the right in the graphs implying reduced wall stiffness during EGF treatment. In conclusion EGF treatment for 1 to 4 weeks caused a time-dependent increase in intestinal weight. The growth was characterized by increased wall thickness, increased cross-sectional area and reduced wall stiffness.

Animals↗

Discrimination between artefacts and contractions in pressure signals from the gastrointestinal tract by pattern recognition method.

A pattern recognition algorithm has been developed to discriminate between artefacts and contractions in interdigestive motility recorded by a pressure catheter with four channels from the human duodenum. A learning and a test set, both containing natural and induced artefacts, such as respiration and body movement, are obtained from five volunteers. The event classes were phase I, II and III contractions of the interdigestive motility complex and artefacts from respiration, cough, calibration signals and movements. Length, area, amplitude, inter-event interval, up- and downstroke, and correlation to other pressure channels and to respiration, are applied to classify the events. The sensitivity of the computer scoring increases with the number of applied features. When all the features are applied, the sensitivity of the Bayes' classifier against the visually scored contractions and artefacts is 0.96 with a specificity of 0.69.

Adult↗

Impedance planimetric characterization of the distal oesophagus in the Goettingen minipig.

Regional differences in biomechanical properties of the oesophagus were studied in 15 healthy Goettingen minipigs by means of impedance planimetry. The investigation was performed during anaesthesia by stepwise pressure-induced balloon distensions with concomitant measurement of pressure and luminal cross-sectional area (CSA) in the oesophagus 5 and 10 cm above the gastro-oesophageal junction. The circumferential wall tension, circumferential strain and incremental elastic modulus were computed from the measurements of pressure and CSA at steady-state conditions. Probably due to the anaesthesia, only scant peristalsis was recorded and the CSA always reached steady state during the balloon distensions. The CSAs were highest in the distal oesophagus (P < 0.001). At the highest induced pressure, the CSAs were 605 +/- 32 and 453 +/- 29 mm2 (mean +/- SEM) for the locations 5 and 10 cm from the gastro-oesophageal junction. The tension-strain distributions were non-linear and the curve obtained 5 cm above the gastro-oesophageal junction was shifted to the right when compared with the curve obtained from 10 cm above this junction. Fitting of the function tension = exp(a+b strain) to the data gave determination coefficients higher than 0.97 and P values lower than 0.001 for both measuring points. The constant a differed between the two locations in the oesophagus (P < 0.05). In conclusion, the pressure-CSA and the tension-strain distributions differed between the two measuring points suggesting that the elastic properties are different.

Anesthesia, General↗

Porcine coronary artery pharmacodynamics in vitro evaluated by a new intravascular technique: relation to axial stretch.

A new intravascular balloon catheter-based technique, impedance planimetry and the wire-mounted isometric tension technique commonly employed to study vessel pharmacodynamics in vitro, were compared. Porcine left anterior descendent coronary artery reactivity to nifedipine was assessed and the influence of 20% axial stretch was investigated. There were no histological differences between segments where the impedance planimetry balloon had been inflated and untouched segments. EC50 values differed significantly between the three procedures applied: The isometric method (n = 7): 2.54 +/- 0.44.10(-9) M; nonstretched arteries by the impedance planimetric method (n = 7): 1.99 +/- 0.40.10(-8) M; arteries 20% axially stretched (n = 7): 2.00 +/- 1.36.10(-7)M (isometric and nonstretched: p < 0.05; isometric and stretched: p < 0.001; nonstretched and stretched: p < 0.05). Maximal relaxant responses to nifedipine were 91.8 +/- 2.1% (isometric method), 105.1 +/- 2.3% (nonstretched), and 104.9 +/- 7.7% (stretched) (ANOVA, p = 0.11). In stretched arteries, the initial 12-min response to an increased dose of nifedipine was more rapid than the response of nonstretched arteries at a concentration of 1.10(-7) M (p = 0.038) and had a nonsignificant tendency toward a more rapid response at other concentrations. Resting tone could not be demonstrated and time control experiments showed no change in the maximal vessel response to potassium with any of the three methods. A new method in the evaluation of artery pharmacodynamics in vitro was presented. The study demonstrated that axial stretching of an artery has impact on the pharmacodynamic reactivity to nifedipine in porcine coronary arteries. Further studies are needed to evaluate the impact of the method on endothelial function.

Animals↗

Elastic properties in the circumferential direction in isolated rat small intestine.

The aim was to study the passive biomechanical wall properties in the isolated duodenum, jejunum and ileum of the rat. The organ bath contained a Krebs-Ringer solution with 10(-2) M MgCl2 to abolish smooth muscle contractile activity. Stepwise inflation of an intraluminal balloon, in which the cross-sectional area (CSA) was measured, provided the distension stimulus. The circumferential wall stress-strain distributions were computed from steady-state values of these measurements and the unstressed wall thickness was measured in order to evaluate the passive elastic properties. The CSAs measured increased from duodenum to jejunum and to ileum (P < 0.001). At the highest applied pressure load the CSA was 16.64 +/- 0.46 mm2 for the duodenum, 18.70 +/- 0.53 mm2 for the jejunum and 21.73 +/- 0.49 mm2 for the ileum. The wall thickness was 0.19 +/- 0.01, 0.25 +/- 0.01 and 0.28 +/- 0.02 mm, in duodenum, jejunum and ileum, respectively (P < 0.01). All segments showed stress-strain distributions that were exponential by nature. Applying the function Y = exp (a + bX) gave a median determination coefficient of 0.98 (quartiles 0.96-0.99). The duodenum was significantly stiffer than the two other segments. The values of a and b were 2.03 +/- 0.11 and 14.82 +/- 1.81, 1.39 +/- 0.20 and 13.15 +/- 1.42, and 1.13 +/- 0.13 and 10.69 +/- 0.65 for the duodenum, jejunum and ileum, respectively. The a differed between the duodenum and the other segments (P < 0.001). whereas the b differed only between the duodenum and ileum (P < 0.005). In conclusion, differences in the luminal CSA, wall thickness and elastic properties were found between the duodenum, jejunum and ileum.

Animals↗

Biomechanics of the gastrointestinal tract.

As the function of the gastrointestinal tract is to a large degree mechanical, it has become increasingly popular to acquire distensibility data in motility research based on various parameters. Hence it is important to know on which geometrical and mechanical assumptions the various parameters are based. Currently, compliance and tone derived from pressure-volume curves are by far the most often used parameters. However, pressure-volume relations obtained in tubular organs must be carefully interpreted as they provide no direct measure of luminal cross-sectional area and other variables useful in plane stress and strain analysis. Thus, erroneous conclusions concerning tissue distensibility may be deduced. Other parameters, such as wall tension, stress and strain, give more useful information about mechanical behaviour. Distensibility data procure significance in fluid mechanics and in the study of tone, peristaltic reflexes, and mechanoreceptor kinematics. Such data are needed for the determination of the interaction between stimulus, electrical responses in neurons and the mechanical behaviour of the gut. Furthermore, from a clinical perspective, investigation of visco-elastic properties is important because GI diseases are associated with growth and remodelling. For example, prestenotic dilatation, increased collagen synthesis, dysmotility and altered distensibility are common features of obstructive diseases. The purpose of this review is to discuss the physiological and clinical importance of acquiring biomechanical data, distensibility parameters and interpretation of these results and their associated errors. We will also discuss some aspects of the relationship between morphology, growth and biomechanics. Finally, we will outline a number of techniques to study the mechanical properties of the GI tract.

Biomechanical Phenomena↗