PubMed Health⌕ Search

Biomedical subjects

H J Geschwind

Publications and source records attributed to H J Geschwind.

At least 37 records · Page 2Linked to original sources

Excimer and holmium yttrium aluminum garnet laser coronary angioplasty.

Recently access to the coronary arteries became available to laser angioplasty because of a new technique utilizes a pulsed laser source and multifiber, "over-the-wire" guided catheters. The aim of this study was to evaluate the early and long-term results and the side effects of coronary angioplasty with an excimer or a Ho-YAG laser. Forty consecutive patients were treated with the Ho-YAG laser (group I) and 46 consecutive patients were treated with the excimer laser (group II). The primary laser angioplasty success rate was 55% and 72% (NS) for groups I and II, respectively. This success rate was highest in saphenous vein grafts. It was similar in calcified and noncalcified lesions and in total occlusions and stenoses. It tended to be lower in long lesions than in short ones (40% vs 60%; p < 0.05 and 44% vs 78%; NS for groups I and II, respectively). Laser stand-alone therapy was performed in 5% of patients in group I compared with 22% in group II (p < 0.05). Failures were due to the inability of the laser catheter tip to reach the lesion, to cross the obstruction, or to obtain a significant reduction in stenosis. They were more frequent in patients in group I than in those in group II (45% vs 28%). There were no deaths, no myocardial infarctions, and no need for emergency coronary artery bypass grafting because most patients had total occlusions or a well-protected coronary artery. Complications included acute closure in 8% of patients in group I and in 17% of patients in group II and spasm in 10% and 13% of patients in groups I and II, respectively. Dissection occurred more frequently in patients in group II than in those in group I (28% vs 7%; p < 0.04). The angiographic patency rate at 6-month follow-up was 33% and 29% for patients groups I and II, respectively. Multifiber, wire-guided catheters provide easy access to the coronary arteries. Excimer laser angioplasty is effective but induces a high rate of dissections. Technical improvements are required to ablate more tissue to possibly reduce the restenosis rate. Further studies are needed to elucidate the mechanism of side effects and to reduce the restenosis rate.

Adult↗

Assessment of coronary vasomotion by intracoronary ultrasound.

This study was performed to evaluate the accuracy of intravascular ultrasound for the assessment of coronary artery vasomotion and endothelial function in patients with atherosclerosis. Twenty patients with luminal irregularities on the coronary angiogram and a high cholesterol level (287 +/- 19 mg/dl) (group 1) and six patients with angiographically smooth arteries and a minimally elevated cholesterol level (197 +/- 12 mg/dl) (group 2) were studied. A mechanical intravascular ultrasound probe (4.3F) was placed into the proximal segment of the coronary artery. The ultrasound images were recorded on super VHS videotape and were then digitized allowing the measurement of the lumen area and then the calculation of a mean intimal thickness index. Endothelial function was studied during sympathetic stimulation by a cold pressor test and, after increasing coronary blood flow, by intracoronary papaverine administration; a 1 mg bolus of linsidomine was then administered into the coronary artery. Patients in group 1 had a higher mean intimal thickness (1.52 +/- 0.64 mm) than those in group 2 (0.18 +/- 0.08 mm) (p < 0.001). In response to sympathetic stimulation, a vasoconstricting effect occurred in group 1 (9.5 +/- 1.3 mm2 vs 11.4 +/- 1.2 mm2 at baseline, p < 0.05), while a vasodilating action was observed in the control group (11.6 +/- 2.1 mm2 vs 10.4 +/- 1.8 mm2 at baseline, p < 0.05). After papaverine infusion, a trend toward a vasoconstricting effect was observed in response to increased flow in group 1 (10 +/- 1.3 mm2 vs 11.4 +/- 1.2 mm2 at baseline, p < 0.05). that was not observed in group 2 (9.4 +/- 2 mm2 vs 8.9 +/- 1.9 mm2, p = NS). Linsidomine infusion induced a significant vasodilating effect in both groups (p < 0.001). In conclusion, intravascular ultrasound may be considered a useful tool to assess endothelial function of large coronary arteries and to obtain the precise relationship between wall thickness and the vasomotor response.

Aged↗

[Percutaneous coronary angioplasty by ultraviolet and infrared laser].

Laser angioplasty can now be performed on the coronary arteries as sources of pulsed laser and steerable multifibre catheters have become available. The aim of this study was to analyse the immediate results, the outcome and secondary effects of coronary angioplasty with excimer and holmium YAG laser. The homium-YAG laser was used in 40 patients (Group I) and the excimer laser in 46 patients (Group II). The immediate success rates were 55% in Group I and 71.7% in Group II. The highest success rates were obtained in lesions of saphenous vein grafts. The primary success rate was remarkably high in calcific lesions and complete occlusions. It was less impressive in long than in short stenoses in Group I. Treatment by laser coronary angioplasty alone was successful in 21.7% of patients in Group II and 5.0% of patients in Group I (p < 0.05). The failures were related to difficulty in reading the lesion, in passing the stenosis or in obtaining a reduction of its severity. The failures were more common in Group I (45%) than in Group II (28.3%). In this preliminary series there were no deaths, myocardial infarcts or emergency coronary bypass procedures. The following complications were observed: acute occlusions in 17.1% of patients in Group I and 7.5% of patients in Group II; spasm (10-13%); coronary dissection was commoner in Group II (28.3%) than in Group I (7.5%, p < 0.04). Angiographic and clinical follow-up at 6 months showed a restenosis rate of 46% in Group I and 43% in Group II.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Aneurysmal formation after successful pulsed laser coronary angioplasty.

We report two cases of coronary artery aneurysmal formation as long term consequences of Ho:YAG and excimer laser coronary angioplasty. This case report suggests that pulsed laser angioplasty may result in severe vessel wall damage that may lead ultimately to aneurysmal formation.

Angina, Unstable↗

Percutaneous angioscopic evaluation of luminal changes induced by excimer laser angioplasty.

Angioscopy has been shown to provide more detailed information on lesion morphology before and after interventional procedures than angiography. Therefore to evaluate the effects of laser angioplasty, angioscopy was performed in five patients with peripheral or coronary vascular disease who underwent excimer laser angioplasty. The excimer laser was operated at 308 nm, 135 nsec, 25 Hz, and 40 to 60 mjoules/mm2 and was coupled into multifiber wire-guided catheters of 1.4 to 2.0 mm diameter for coronary lesions and into catheters of 2.2 mm diameter for peripheral lesions. There were three coronary (one left anterior descending, one circumflex, one right coronary artery) and two peripheral (one common iliac artery, one superficial femoral artery) lesions. Angioscopy was successfully performed before and after laser ablation without any complications in all five lesions. The characteristics of angioscopic findings after excimer laser angioplasty consisted of flaps, fractures of plaques, and abundant tissue remnants. There was no apparent thermal injury. Recanalized channels were small and irregular. These results indicate that (1) angioscopy is effective and safe for evaluation of lesion morphology after laser angioplasty; (2) laser ablation does not result in thermal injury; and (3) irregular channels after recanalization and abundant tissue remnants may explain the suboptimal results after laser angioplasty.

Adult↗

Comparison of ablation efficacy of excimer, pulsed-dye, and holmium-YAG lasers relevant to shock waves.

Ablation efficacy of pulsed lasers on human arterial tissue and associated shock waves have been investigated by means of excimer laser at 308 nm, pulsed-dye laser at 480 nm, and holmium-YAG laser at 2.1 microns. A multifiber catheter was used for lasing at 420 mjoules/pulse with holmium-YAG, 18.9 mjoules/pulse with excimer, and 100 mjoules/pulse with pulsed-dye laser. Ablation efficiency (ablated volume/energy) was greatest with pulsed-dye laser in blood and excimer laser in saline solution. There was selectivity for atheroma with pulsed-dye laser (ablation efficiency in atheroma versus normal tissue, 58 versus 27 x 10(-2) mm3/joule in blood; p less than 0.005) and holmium-YAG laser (12.6 versus 5.6 x 10(-2) mm3/joule in blood; p less than 0.001). Ablation efficiency of pulsed-dye laser was enhanced by blood (0.58 in blood versus 0.17 mm3/joules in saline for atheroma; p less than 0.005). Shock waves were correlated with ablation efficiency (r = 0.63 and 0.74 for pulsed-dye laser and holmium-YAG laser, respectively). There was neither selectivity for atheroma nor influence of blood medium with excimer laser. Only holmium-YAG laser could ablate tissue at a distance from the target in the blood medium. Histologic findings showed that all lasers could create smooth-edged craters with minimal coagulation necrosis. In conclusion, laser irradiation with holmium-YAG and pulsed-dye lasers could selectively ablate atheromatous tissue with minimal thermal injury, whereas excimer laser could not. Ablation efficiency was correlated with shock waves. Efficiency of pulsed-dye laser was enhanced by blood.

Angioplasty, Laser↗

Characteristics of shock waves induced by pulsed lasers and their effects on arterial tissue: comparison of excimer, pulse dye, and holmium YAG lasers.

Shock waves were investigated using an excimer laser at 308 nm with 18.9 mjoules/pulse, a pulsed dye laser at 480 nm with 100 mjoules/pulse, and a holmium YAG (yttrium-aluminum-garnet) laser at 2.1 microns with 420 mjoules/pulse. At a distance from the target tissue, excimer lasing resulted in no shock waves in saline, while the other lasers produced smaller shock waves than those recorded when the laser was in contact with tissue (0.22 versus 2.0 mm Hg with the pulsed dye laser, 0 versus 0.23 mm Hg with the excimer laser, and 0.44 versus 6.9 mm Hg with the holmium YAG laser; p less than 0.001, respectively). In blood, excimer laser irradiation at a distance from the tissue produced shock waves as great as those produced when the laser was in contact with the tissue (0.19 versus 0.24 mm Hg with the excimer laser, 1.8 versus 3.0 mm Hg with the pulsed dye laser, and 3.1 versus 5.9 mm Hg with the holmium YAG laser; p less than 0.001 with the pulsed dye and holmium YAG lasers, respectively). When lasing was done at 60 mjoules/mm2, the pulsed dye and excimer lasers produced similar shock waves when the lasers were in contact with tissue; however, the holmium YAG laser did not produce shock waves. Thus pulsed lasers can produce shock waves of different characteristics according to the laser source.

Analysis of Variance↗

Tissue ablation with excimer laser and multiple fiber catheters: effects of optical fiber density and fluence.

This study was performed to assess the ablational properties of 1.4-, 1.7-, and 2.0-mm wire-guided multiple fiber catheters coupled to a XeCl excimer laser. Samples of postmortem human aorta were irradiated in blood at fluences of 40, 50, and 60 mJ/mm 2. Our results indicate that: 1) an increase in the active irradiation coverage results in an increase in the ablation efficiency; 2) the ablation efficiency is not fluence related using the 1.4- or 1.7-mm multiple fiber catheter but efficiency is fluence dependent using the 2.0-mm multiple fiber catheter; 3) the depth of tissue ablated with a multiple fiber catheter depends primarily upon the proportion of the active irradiation coverage at the catheter tip; 4) the 2.0-mm multiple fiber catheter induces craters surrounded by a larger zone of tissue damage than that observed with the 1.4- or 1.7-mm multiple fiber catheter; and 5) the 2.0-mm multiple fiber catheter should be used cautiously for laser angioplasty because of its high penetration and its risk of arterial wall damage.

Angioplasty, Laser↗

Enhancement of pulsed-dye laser ablation of arterial tissues with blood medium: effects of laser-induced shock waves.

The influence of blood medium on tissue ablation by a pulsed dye laser and its selectivity for atheroma were investigated. The role of shock waves on tissue ablation was also evaluated. Normal and atherosclerotic human aortas were irradiated by a 480 nm pulsed dye laser activated at 5 Hz. The laser was coupled with a single 0.2 mm fiber (Uni-guide) (40 mjoules/pulse) or a multifiber catheter (14 x 150 microns) (100 mjoules/pulse). Shock waves were measured using a fluid-filled catheter connected to a strain gauge manometer. With the Uni-guide, pulse-dye lasing resulted in greater ablation of atheroma in blood (11.6 x 10(-3) mm3/joule, p less than 0.001 versus atheroma measured in saline and normal tissue in blood) followed by normal tissue in blood (2.5 x 10(-3)mm3/joule), atheroma in saline (1.71 x 10(-3)mm3/joule, p less than 0.05 versus normal tissue in saline), and normal tissue in saline (0.54 x 10(-3) mm3/joule). With the multifiber catheter, laser ablation was the greatest in atheroma in blood (0.55 +/- 0.26 mm3/joule p less than 0.001 versus atheroma in saline and normal tissue in blood), followed by normal tissue in blood (0.27 +/- 0.12 mm3/joule), atheroma in saline (0.14 +/- 0.15 mm3/joule, p less than 0.001 versus normal tissue in saline), and normal tissue in saline (0 mm3/joule). The ablation efficiency of the multifiber catheter was greater than that of the Uni-guide (p less than 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Laser↗

Percutaneous coronary mid-infra-red laser angioplasty.

A pilot study was performed to determine the safety and efficacy of coronary pulsed mid-infra-red laser angioplasty. The laser was coupled with a novel 2.0 mm multifiber catheter consisting of 37 optical fibers of 150 microns each arranged concentrically around a 0.018-inch central lumen and a soft leading tapered distal tip to maintain coaxial alignment and position plaque in front of fibers. The laser was operated at 500 millijoules/pulse, 3.5 Hz, and 250 microseconds/pulse. Twenty-three patients with stenosis or occlusion of the left anterior descending or right coronary artery were selected for laser treatment. In three patients the catheter could not be positioned against the obstruction. In the 20 remaining patients laser angioplasty increased the diameter of the lumen from 0.3 +/- 0.3 mm to 1.4 +/- 0.3 mm and reduced the stenosis from 91 +/- 8% to 57 +/- 10%. In three patients "stand-alone" laser treatment was sufficient. In 17 patients balloon dilatation further reduced the stenosis to 20 +/- 18%. In two patients who had previously undergone unsuccessful balloon angioplasty with high inflation pressure, laser angioplasty allowed subsequent successful dilatation with low inflation pressure. There were no deaths, perforations, dissections, or arrhythmias. One patient had abrupt reclosure 24 hours after the procedure. Spasm occurred in four patients, and six patients had chest sensations during laser emission. Thus mid-infra-red pulsed coronary laser angioplasty is safe and effective for recanalization of stenosed and totally occluded arteries. The efficacy may be sufficient for "stand-alone" laser treatment. The technique may improve the efficacy of balloon angioplasty in cases of unsuccessful primary dilatation.

Adult↗

Holmium YAG laser coronary angioplasty with multifiber catheters.

Excimer lasers are being extensively used for coronary angioplasty along with multifiber over-the-wire catheters. To determine whether another wavelength could be an alternative, the laser-tissue interaction and the clinical usefulness of an infrared laser were studied. The laser consisted of a Holmium YAG pulsed laser coupled into a multifiber catheter. Experimental data from our laboratory showed that this solid state laser had the ability to cut calcified tissue, to be preferentially absorbed by atheroma, and to ablate tissue even when the catheter tip was positioned at a distance from the target. These results were obtained with only minimal thermal effects. After assessment of the efficacy and safety of this technique, laser angioplasty was performed in 53 consecutive patients with totally occluded (40%) or stenosed (mean percent 94) coronary arteries with a mean length of 6 mm. The primary laser and the procedure success rate were 64% and 94%, respectively. Failures were due to inability to advance the catheter against the lesion or to cross the obstruction. Stand-alone laser therapy could be achieved in only 18% of patients. In previous dilatation failures, laser irradiation allowed for subsequent balloon angioplasty to be successfully performed at a lower inflation pressure than that used in the failed dilatation. Complications included abrupt (during the procedure) and early (within 24 hours) vessel closure in 19% of cases, dissection without hemodynamic consequence in 28% and spasm. Reoccluded arteries could all be recanalized with dilatation.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Laser↗

Results and follow-up after percutaneous pulsed laser-assisted balloon angioplasty guided by spectroscopy.

BACKGROUND: Few data are available on the long-term outcome of patients who undergo laser-assisted balloon angioplasty for recanalization of occluded peripheral arteries. Because the cost of laser angioplasty is high, the value of the method should be carefully analyzed before it can be considered a routine method for recanalization. The purpose of this study was to evaluate the early and late results of laser-assisted balloon angioplasty in patients who could not be recanalized by conventional techniques. METHODS AND RESULTS: Laser angioplasty was performed in 66 patients with total occlusion of the iliofemoral artery in whom mechanical techniques failed to recanalize the obstructed vessel. The system consisted of a pulsed dye laser operated at 480 nm, 2 microseconds/pulse, 5 Hz, 50 mJ/pulse coupled into a 0.021-in. laser catheter. The treatment laser was connected with a diagnostic laser to induce tissue fluorescence for spectroscopic analysis via the same fiber. The treatment laser was emitted only when atheromatous tissue was recognized. After a pilot hole was created by laser emission, dilatation was performed to enlarge the channel. The mean length of occlusion was 8.8 +/- 6.1 cm. The primary success rate was 82%. It did not depend on the length of occlusion but was greater in non-calcified than in calcified lesions (88% versus 71%, p less than 0.03). Complications included seven early reocclusions that could be recanalized and eight perforations without clinical sequelae. At a mean 18-month follow-up, 64% of the laser-treated arteries remained patent. The rate of patency was related neither to the length of the occlusion nor to calcifications but was lower in patients who had early reocclusion (p less than 0.02). CONCLUSIONS: Pulsed dye laser-assisted balloon angioplasty is effective for recanalization of totally occluded arteries that cannot be treated by conventional means. The efficacy is limited by calcifications. The long-term patency rate is acceptable given the severity of the lesions.

Angioplasty, Laser↗

Percutaneous pulsed laser-assisted balloon angioplasty guided by spectroscopy.

Percutaneous laser angioplasty was performed in 19 patients with total superficial femoral calcified and noncalcified (4 to 25 cm length) occlusions; a pulsed dye laser of 480 nm was used with a pulse duration of 2 musec/pulse. The treatment laser was guided by a 325 nm diagnostic laser that induced fluorescence. The laser system operated through a single 200 or 500 microns optical fiber. Computerized spectral analysis of the tissue fluorescence located at the distal of the fiber tip allowed the treatment laser to be emitted on the atheroma and not on the arterial wall. Uniform success in primary laser recanalization was demonstrated, which allowed for subsequent balloon dilatation in all but one patient. One mechanical fiber perforation, two mechanical fiber dissections, one guidewire perforation, and one guidewire dissection occurred, but no complications resulting from the treatment or diagnostic laser were observed. The safety of the procedure appears to be enhanced by the spectroscopic guidance system, which allows recognition of plaque. The pulsed dye treatment laser was well tolerated and effective even in heavily calcified arteries.

Adult↗