PubMed HealthSearch

Biomedical subjects

H Kulkarni

Publications and source records attributed to H Kulkarni.

At least 19 recordsLinked to original sources

Transcatheter closure of patent ductus arteriosus in children weighing < 10 kg with Gianturco coils using the balloon occlusion technique.

We evaluated the immediate and intermediate follow-up results of transcatheter closure (TCC) of patent ductus arteriosus (PDA) using Gianturco coils in children weighing < 10 kg. The results of PDA < or = 2.5 mm (group I, n = 18) and > 2.5 mm (group II, n = 16) were compared. Coils were deployed sequentially by transarterial route using a temporary balloon occlusion technique. The immediate clinical success rate in both groups was comparable. There was no significant difference in the number of coils required per patient and in the embolization rate between the two groups. Both groups had comparable occlusion rates at intermediate-term follow-up. At intermediate follow-up, one patient had developed left pulmonary artery stenosis while obstruction of the descending aorta was not seen in any; in 4 children the PDA had recanalized. Spontaneous reocclusion was observed in 3 of the latter at the last follow-up. We conclude that TCC of PDA is feasible and safe in children weighing < 10 kg with gratifying intermediate-term results.

Aortography

New technique using temporary balloon occlusion for transcatheter closure of patent ductus arteriosus with Gianturco coils.

We describe our early experience with a new technique involving temporary balloon occlusion for transcatheter closure of patent ductus arteriosus (PDA) using single or multiple Gianturco coils. Coil occlusion was attempted in 21 patients of median age 3 (range 1-11) years, and angiographic PDA diameter 3.0 mm +/- 0.87 mm. The inflated balloon of a pulmonary wedge pressure catheter over a transductal wire was used to mechanically hold the first extruded loop of the coil at the pulmonary end of the duct. If a residual shunt persisted after the delivery of the first coil, additional coils were delivered with or without the balloon support. One to nine coils (median 2) of different sizes varying between 3-12 mm diameter and 4-15 cm length were used. Immediate angiographic occlusion rate was 47.6%. However color Doppler (CD) at 24 hours and at 6 weeks revealed complete closure in 66.6% and 80.9%, respectively. Blood transfusion was required in 2 (9.5%) patients. Three out of 56 coils (5.4%) embolized during deployment. The use of balloon occlusion is effective and safe in the treatment of ducti up to 4.7 mm. Residual shunts lend to occlude with time.

Aortography

Aneurysms of sinus of Valsalva eroding into the interventricular septum: etiopathology and surgical considerations.

OBJECTIVE: To evaluate and discuss etiopathology, clinical manifestations and surgical outcome of a rare subset of unruptured aneurysm of the sinus of Valsalva which erodes into the interventricular septum. METHODS: Between 1989 and 1995, seven cases of unruptured aneurysm of the sinus of Valsalva eroding into the interventricular septum underwent surgical correction at the King Edward VII Memorial Hospital, Bombay. The origin of all these aneurysms was from the right coronary sinus. The mean age of presentation was 31 years. All patients were male. Calcification of the aneurysm was seen in three. Three patients presented without aortic regurgitation; all had complete heart block. Four patients presented with aortic regurgitation and in addition, two had complete heart block. Preoperative left ventricular function was poor in patients with aortic regurgitation (Ejection fraction range; 30-42%), when compared to those without aortic regurgitation (Ejection fraction range; 48-52%). Of those without aortic regurgitation at initial presentation, one patient developed progressive aortic regurgitation after 3 years requiring surgery. While two other patients were operated at earliest for closure of aneurysm, even in the absence of aortic regurgitation. All those with aortic regurgitation required surgery for aortic valve replacement and closure of aneurysm. Aneurysm was closed by direct suturing of the ostium in two patients and by patch closure in five patients. Permanent pacemaker was implanted in five patients. RESULT: There was no operative death. Patients who underwent aortic valve replacement required postoperative ionotropic support. Two patients, who underwent surgery in absence of aortic regurgitation, remain free of aortic regurgitation at the end of 36 and 42 months of follow-up. One of the patients with calcific aneurysmal sac underwent successful re-replacement of the aortic valve for paravalvar leak after a 2 year interval. CONCLUSION: Unruptured aneurysm of the sinus of Valsalva eroding into the interventricular septum should be operated at the earliest, which makes surgery simple and prevents development of complications such as aortic regurgitation and heart block.

Adult

Occlusion of congenital ventricular septal defects by the buttoned device. "Buttoned device" Clinical Trials International Register.

OBJECTIVES: To study the feasibility of congenital ventricular septal defect occlusion by the buttoned device and to establish guidelines for its safe and effective application. DESIGN: A descriptive study of all patients with a congenital ventricular septal defect undergoing transcatheter occlusion with the buttoned device, from March 1994 to May 1995. These patients were otherwise candidates for elective surgery at their institutions because they had persistence of a significant shunt (Qp:Qs = 1.5-2.1:1, median = 1.7), with left ventricular enlargement and/or symptoms, although their systolic pulmonary artery pressure was invariably normal (20-28 mm Hg, median = 25). The angiographic diameter of the defect ranged from 2.5 to 14 mm (median 6 mm). SETTING: A multi-institutional study. PATIENTS: Out of 25 cases attempted, 18 children and adults aged 4-35 years had devices implanted. Fifteen of these patients had membranous ventricular septal defects and three had muscular defects. All patients with a membranous ventricular septal defect had an associated aneurysm of the membranous septum. INTERVENTIONS: The buttoned device was introduced either directly or, in the last 12 cases, over a wire bridging the femoral artery and the femoral or jugular vein; the devices were delivered through 7-9 French (F) long sheaths. A membranous defect was regarded as suitable for device closure if the distance from the centre of the defect to the insertion of the right coronary aortic valve leaflet was more than 50% of the size of the required device. The device was guided by echocardiography and fluoroscopy. All muscular defects were corrected through the right jugular vein and all membranous ones through the femoral vein. RESULTS: All 18 patients underwent initial successful implantation of the device. In thirteen patients the shunts were completely occluded and in the remaining five there were trivial residual shunts. In two patients with membranous ventricular septal defects a change from the original position was noticed at two weeks; mild aortic regurgitation developed in one and the murmur recurred in the other; the devices had to be removed surgically. One patient developed transient third degree atrioventricular block during implantation; no tricuspid regurgitation was observed. CONCLUSION: Clinical occlusion of congenital ventricular septal defects was achieved in 16 out of the 18 attempted cases (13 full occlusions). Membranous ventricular septal defect occlusion can be effective and safe if patients and device sizes are carefully selected.

Adolescent

Percutaneous balloon mitral valvotomy in mitral restenosis.

BACKGROUND: Mitral restenosis often occurs within 5 to 15 years of surgical valvotomy. Percutaneous balloon mitral valvotomy is well established as a safe and effective alternative to mitral stenosis surgery, but only a few small studies have reported on the procedure. AIM: (i) To evaluate the safety and efficacy of percutaneous balloon mitral valvotomy in patients with mitral restenosis. (ii) To evaluate the intermediate-term outcome of patients undergoing balloon mitral valvotomy after previous surgical valvotomy. (iii) To compare these patients with those undergoing balloon mitral valvotomy as the initial procedure. METHODS: We analysed our experience of 614 consecutive patients undergoing balloon valvotomy and identified 84 patients (13.7%) with mitral restenosis following prior surgical valvotomy (Group I). The remaining 530 patients (86.3%) had not undergone previous surgery (Group II). The incidence of atrial fibrillation (19% vs 5.6%), mitral valve calcification (50% vs 30.6%) and total echo score > 8 (54.8% vs 24.15%) was significantly higher in Group I. Both groups were comparable as regards their functional class, technique of valvotomy, mitral valve area (0.87 +/- 0.18 vs 0.87 +/- 0.15 cm2, P = ns), mean transmitral gradient (19.63 +/- 6.01 vs 19.21 +/- 5.67 mmHg, P = ns), and mean pulmonary artery pressure (42.2 +/- 19.0 vs 40.8 +/- 14.4 mmHg, P = ns). RESULTS: After percutaneous balloon mitral valvotomy, the final mitral valve area (1.67 +/- 0.28 vs 1.69 +/- 0.29 cm2, P = ns), mean transmitral-mitral gradient (6.12 +/- 3.68 vs 5.02 +/- 3.21 mmHg, P = ns) and mean pulmonary artery pressure (31.0 +/- 15.2 vs 28.5 +/- 11.1 mmHg, P = ns) were comparable. The success rate (93.0% vs 95.3%, P = ns) were similar in both groups. Significant mitral regurgitation was seen in four (4.8%) patients in Group I and 22 (4.1%) patients in Group II (P = ns). There were two deaths (2.4%) in Group I and five (0.9%) in Group II (P = ns). The clinical and echo Doppler follow-up (8-40 months) studies showed that both groups were of similar NYHA class, and had similar mitral valve area (1.65 +/- 0.21 vs 1.66 +/- 0.3 cm2) and transmitral gradients (7.1 +/- 3.8 vs 5.9 +/- 3.5 mmHg). CONCLUSION: We conclude that percutaneous balloon mitral valvotomy can be performed safely and effectively in patients with mitral restenosis following surgical valvotomy; the beneficial acute outcome is sustained, as shown at intermediate-term follow-up and is similar to that of patients undergoing balloon mitral valvotomy as an initial procedure.

Adult

Calcium supplementation and prevention of pregnancy induced hypertension.

In a randomized controlled trial 201 healthy nulliparous women were randomly allocated by means of a computer generated randomization list. From 20 weeks of gestation until delivery they received either 2 g of oral elemental calcium (n = 103) per day or an identical placebo (n = 98). Eleven women (5.47%) were lost to follow-up after randomization. The study groups were very similar at the time of randomization; with respect to several clinical and demographic variables. Treatment compliance was very similar in both groups as was determined by pill count. The rate of pregnancy induced hypertension was lower in the calcium group than in the placebo group 8.24%; vs 29.03%; (RR = 0.28; 95% CI 0.14-0.59). The incidence of gestational hypertension was 6.18% in the calcium group and 17.20% in the placebo group (RR = 0.28; 95% CI 0.08-0.80), and the incidence of preeclampsia was 2.06% in the calcium group and 11.82% in the placebo group (RR = 0.13; 95% CI 0.01-0.64). In conclusion calcium supplementation given in pregnancy to nulliparous women reduces the incidence of pregnancy induced hypertension.

Calcium

Balloon mitral valvotomy: an autopsy study.

The autopsy findings in 20 patients who died following percutaneous balloon mitral valvotomy are reported. The procedure was attempted in 508 patients. In 17 of the 20 patients, balloon mitral valvotomy was attempted as a salvage procedure. Ten patients died in the immediate post valvotomy period (within 24 h), seven died within a week and three between 1 to 3 months. In 13 patients, the balloon valvotomy successfully opened out one or both commissures. Interatrial septostomy defects created by the transeptal catheter could be identified in 19 of 20 heart specimens. The size of the defects ranged from small (5 mm) openings to large (15 mm) defects especially with double balloon. Marked mitral valvar thickening with nodular calcification was observed in 16 cases. Significant complications leading to mortality included cardiac tamponade (five cases) due to left ventricle apical perforation (3/5 cases). Mitral valve damage in the form of leaflet tears, chordal rupture and long splits in five cases resulted in significant mitral regurgitation. The leaflet tears resulted in detachment of part of the leaflet from the annulus. A late complication noted was infective endocarditis. Associated pulmonary tuberculosis, chronic obstructive pulmonary disease, respiratory infections and multivalvar diseases also contributed to mortality.

Adolescent

Effect of 3 week oxygen therapy on functional and haemodynamic parameters in chronic obstructive pulmonary disease.

Sixteen patients with advanced chronic obstructive pulmonary disease (COPD) and stable chronic respiratory failure (pO2 less than 60 mm Hg, pCO2 greater than 45 mm Hg) were given 2-3 L/min oxygen 18 hours/day for 3 weeks. These were serially assessed for changes in pO2, pCO2, ECG, chest radiographs and haemodynamics. Initially all patients were in grade IV heart failure. There was no change in lung function after oxygen treatment but right descending pulmonary artery diameter and cardiothoracic ratio decreased significantly (P less than 0.01), as also the height of the P wave in ECG (P less than 0.05). There were significant changes in mean pO2 (51.8 to 61.9 mmHg; P less than 0.01), pCO2 (55.3 to 47.6 mmHg; P less than 0.001), mean pulmonary artery pressure (41.8 to 34.5 mmHg; P less than 0.01) and pulmonary vascular resistance (PVR) (346.4 to 163.3 dynes; P less than 0.05). The initial (P less than 0.05) and 3 week (P less than 0.01) pO2 levels correlated with the right descending pulmonary artery diameter. The height of the P wave also correlated with pO2 (P less than 0.01). The changes in pO2 levels correlated with those of the PVR and pulmonary blood flow (P less than 0.05). Three week oxygen therapy resulted in objective improvement in advanced COPD cases.

Adult

Electrocardiographic manifestations of the rapid recharge function of pulse generators after sensing.

In this report, we present our observations in three patients with Medtronic Spectrax VVI pulse generators that exhibited unusually clear electrocardio-Spectrax VVI pulse generators that exhibited unusually clear electrocardiographic artifacts, due to the rapid recharge function upon sensing. Although many contemporary pulse generators contain rapid recharge circuits operative after the delivery of a pacemaker stimulus, only certain Medtronic Spectrax pulse generators also possess a rapid recharge capability after sensing. Rapid recharge upon sensing may produce electrocardiographic deflections that should not be misinterpreted as pacemaker malfunction.

Electrocardiography