A simple technique to cross mitral valve during percutaneous balloon mitral valvuloplasty.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to H Kulkarni.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Sixteen patients with advanced chronic obstructive pulmonary disease (COPD) and stable chronic respiratory failure (pO2 less than 60 mm Hg, pCO2 greater than 45 mm Hg) were given 2-3 L/min oxygen 18 hours/day for 3 weeks. These were serially assessed for changes in pO2, pCO2, ECG, chest radiographs and haemodynamics. Initially all patients were in grade IV heart failure. There was no change in lung function after oxygen treatment but right descending pulmonary artery diameter and cardiothoracic ratio decreased significantly (P less than 0.01), as also the height of the P wave in ECG (P less than 0.05). There were significant changes in mean pO2 (51.8 to 61.9 mmHg; P less than 0.01), pCO2 (55.3 to 47.6 mmHg; P less than 0.001), mean pulmonary artery pressure (41.8 to 34.5 mmHg; P less than 0.01) and pulmonary vascular resistance (PVR) (346.4 to 163.3 dynes; P less than 0.05). The initial (P less than 0.05) and 3 week (P less than 0.01) pO2 levels correlated with the right descending pulmonary artery diameter. The height of the P wave also correlated with pO2 (P less than 0.01). The changes in pO2 levels correlated with those of the PVR and pulmonary blood flow (P less than 0.05). Three week oxygen therapy resulted in objective improvement in advanced COPD cases.
In this report, we present our observations in three patients with Medtronic Spectrax VVI pulse generators that exhibited unusually clear electrocardio-Spectrax VVI pulse generators that exhibited unusually clear electrocardiographic artifacts, due to the rapid recharge function upon sensing. Although many contemporary pulse generators contain rapid recharge circuits operative after the delivery of a pacemaker stimulus, only certain Medtronic Spectrax pulse generators also possess a rapid recharge capability after sensing. Rapid recharge upon sensing may produce electrocardiographic deflections that should not be misinterpreted as pacemaker malfunction.
Explore the source record for details and available documents.
Twenty children (mean age 3.25 years) with congenital cyanotic heart disease undergoing modified left Blalock-Taussig (BT) shunt were studied. The mean follow-up period was 9.5 months (range 6 months to 1 year). The shunt was performed for cyanotic spells in 15 (75%) and hypoplastic pulmonary arteries in 5 (25%) patients. There were no immediate or late complications. None had cyanotic spell after the shunt. The mean arterial oxygen saturation improved from 66.47 +/- 11.9 to 76.97 +/- 8.16% (p = 0.0003) and mean hematocrit decreased from 51.55 +/- 9.5 to 46.5 +/- 9.7 (p = 0.002) after the shunt. The left atrial systolic volume and left ventricular diastolic volume also increased significantly following the shunt (from 15.82 +/- 6.37 to 20.83 +/- 8.91 ml p = 0.006 and from 36.13 +/- 16.08 to 41.08 +/- 20.07 ml (p = 0.01) respectively. There was significant growth of main, right and left pulmonary arteries and pulmonary valve annulus after the procedure.
2 cases of unruptured aneurysm of the sinus of Valsalva are presented. Both the patients had involvement of the right sinus of Valsalva. One of the patients had associated systemic lupus erythematosus (SLE). Such an association has not been described in the literature. Clinical, echocardiographic and the angiographic features have been discussed and literature reviewed.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Acute hemodynamic effects of high flow oxygen (O2) inhalation, sublingual isosorbide dinitrate (ISDN), intravenous aminophylline (AMN) and sublingual nifedipine (NIF) were studied in 32 patients with primary pulmonary hypertension (PPH). In 30 out of 32 patients the basal ratio of pulmonary to systemic vascular resistance (Rp/Rs) was > 0.5 (mean = 0.77 +/- 0.20). Oxygen caused significant decrease in the mean resistance ratio to 0.68 +/- 0.20 (p = 0.005). ISDN, AMN and NIF caused increase in the resistance ratio to 0.79 +/- 0.26; 0.78 +/- 0.26; and 0.80 +/- 0.23 respectively. O2, ISDN, AMN and NIF caused a fall of Rp/Rs in 21 (65.6%), 10 (31.2%), 10(31.2%) and 9(28.1%) patients respectively. Thus, of the four drugs tested high flow O2 inhalation resulted in fall of Rp/Rs in two thirds of patients whereas ISDN, AMN and NIF caused a mean rise in Rp/Rs. One third of patients did respond acutely to the latter three drugs. Acute hemodynamic studies are useful before prescribing vasodilators in patients with PPH since more of the commonly used drugs like ISDN, AMN, NIF could have detrimental hemodynamic responses in some patients. However, great caution should be exercised before performing hemodynamic study as the procedure has definite mortality and morbidity.