PubMed Health⌕ Search

Biomedical subjects

H P Weber

Publications and source records attributed to H P Weber.

At least 19 recordsLinked to original sources

A time-dependent healing function for immediate loaded implants.

Current interest in immediate dental implant loading has grown due to a number of clinical advantages this treatment modality offers. To obtain a deeper insight into the changing mechanical properties during the healing phase, results from removal torque tests are used in a biomechanical model. The ultimate removal torques, which depend on healing time, are described by a time-dependent healing function. The bone behavior is modeled using an elastic law with damage. The evolution of damage is represented with an incremental equation with an initial damage value and two material parameters. The nonlinear relationship between the torque and the angle of rotation up to the ultimate torque can be calculated. By changing the elastic parameter in the elastic damage law, the remodeling process can be characterized. In a further step, the elastic parameters and the limits for shear stress from the biomechanical model for the removal torque will be used in an FE analysis in order to obtain information on the axial loading limits of a dental implant at different healing times.

Biomechanical Phenomena↗

Experimental and theoretical identification of a new high-pressure TiO2 polymorph.

Our combined theoretical and experimental investigations have led to the discovery of a new polymorph of titanium dioxide, where titanium is seven-coordinated to oxygen in the orthorhombic OI ( Pbca) structure. The zero-pressure bulk modulus of the new phase measured in the pressure range 19 to 36 GPa is 318(3) GPa. We demonstrate that the group IVa dioxides (TiO2, ZrO2, HfO2) on compression at ambient temperature all follow the common path: rutile -->alpha-PbO2-type --> baddeleyite-type (MI) --> orthorhombic OI (Pbca) structure --> cotunnite-type (OII).

Journal Article↗

Laser solder welding of articular cartilage: tensile strength and chondrocyte viability.

BACKGROUND AND OBJECTIVE: The surgical treatment of full-thickness cartilage defects in the knee joint remains a therapeutic challenge. Recently, new techniques for articular cartilage transplantation, such as mosaicplasty, have become available for cartilage repair. The long-term success of these techniques, however, depends not only on the chondrocyte viability but also on a lateral integration of the implant. The goal of this study was to evaluate the feasibility of cartilage welding by using albumin solder that was dye-enhanced to allow coagulation with 808-nm laser diode irradiation. STUDY DESIGN/MATERIALS AND METHODS: Conventional histology of light microscopy was compared with a viability staining to precisely determine the extent of thermal damage after laser welding. Indocyanine green (ICG) enhanced albumin solder (25% albumin, 0.5% HA, 0.1% ICG) was used for articular cartilage welding. For coagulation, the solder was irradiated through the cartilage implant by 808-nm laser light and the tensile strength of the weld was measured. RESULTS: Viability staining revealed a thermal damage of typically 500 m in depth at an irradiance of approximately 10 W/cm(2) for 8 seconds, whereas conventional histologies showed only half of the extent found by the viability test. Heat-bath investigations revealed a threshold temperature of minimum 54 degrees C for thermal damage of chondrocytes. Efficient cartilage bonding was obtained by using bovine albumin solder as adhesive. Maximum tensile strength of more than 10 N/cm(2) was achieved. CONCLUSIONS: Viability tests revealed that the thermal damage is much greater (up to twice) than expected after light microscopic characterization. This study shows the feasibility to strongly laser weld cartilage on cartilage by use of a dye-enhanced albumin solder. Possibilities to reduce the range of damage are suggested.

Animals↗

Comparative in vitro study of tissue welding using a 808 nm diode laser and a Ho:YAG laser.

In vitro porcine arteries and veins have been welded end-to-end using either a 808 nm diode laser combined with an indocyanine green enhanced albumin solder, or with a continuous-wave (cw) Ho:YAG laser without biological solder. The vascular stumps were approached to each other over a coronary dilatation catheter in order to obtain a precise alignment and good coaptation. Standard histology revealed for both welding techniques lateral tissue damage between 2 and 3 mm caused by laser-induced heat. Good solder attachment to the tissue was observed by the use of a scanning electron microscope. The vessels soldered with the 808 nm diode laser using albumin solder showed considerably higher tensile strength (1 N compared to 0.3 N) than vessels welded exclusively by Ho:YAG laser radiation. In contrast, leaking pressure (350 +/- 200 mmHg) and bursting pressure (457 +/- 200 mmHg) were found to be independent of the welding technique used. This study demonstrates that fast (total welding time about 2-5 min), stable and tight microvascular anastomosis can be achieved with the use of a dye-enhanced albumin laser soldering technique and an ancillary coronary dilatation catheter.

Anastomosis, Surgical↗

Connective tissue orientation around dental implants in a canine model.

The objective of this study was to evaluate the orientation of collagen in the canine gingival connective tissue to a titanium surface (TI), and to hydroxyapatite coatings applied by plasma-spraying (HAPS) and ion beam assisted deposition (IBAD), on the supracrestal region of dental implants after 3 and 4 months. The effects of induced peri-implantitis on the soft connective tissue apposed to the implant were also evaluated. The use of these three surface types allowed for the evaluation of the effects of chemical composition (TI vs. IBAD; same topography) and topography (HAPS vs. IBAD; similar chemical composition) on the collagen fiber orientation. The majority of collagen fibers were found to be parallel to the implant surface, and there was no significant effect of surface type on orientation. There was a significant effect of inflammation on the connective tissue attachment length. The loss of bone height and concomitant gingival recession reduced the length of soft connective tissue apposed to the implant zone designed for collagen fiber attachment.

Analysis of Variance↗

Overdenture attachment selection and the loading of implant and denture-bearing area. Part 1: In vivo verification of stereolithographic model.

Preliminary to a study investigating the force transfer from osseointegrated dental implants to the surrounding bone via various types of overdenture attachment, a stereolithographic model (SL-model) was constructed and compared to an in vivo situation in order to confirm the validity of the modeling technique for the planned measurements of implant strain and denture-bearing area loading. The SL-model was generated using the patient's computer tomographic data and duplicated in a material of known elastic properties. The model was fitted with sensors to measure strains in the peri-implant bone and loading forces within the posterior mandibular bone, i.e. the denture-bearing area of the mandible. Special telescopic copings were constructed to measure implant strain in this model as well as in vivo. Using these copings under identical overdenture loading conditions, the strains measured at the implants in vivo and in vitro were the same and never exceeded a tolerance of two standard deviations or a mean difference of -8.5% of the in vitro value. This indicates that the model was reliable for the measurement of implant strain. Denture-bearing area loading within the alveolar ridge cannot be measured in vivo. Instead, a method of extrapolating in vivo denture-bearing area loading figures from implant strain readings was developed and tested (better than 90% accuracy). These in vivo extrapolated figures were then compared to in vitro readings under otherwise identical loading conditions. The result indicated that the SL-model is reliable for measurements of denture-bearing area loading with an error of 10 to 20%.

Calibration↗

Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment.

In general, an implant is loaded via axial and horizontal forces. Besides this, moment loading can also occur. The aim of this study was to investigate how different prosthetic connectors with overdentures develop force transfer to implant and bone as well as to the denture-bearing alveolar ridge. Five connectors were investigated on a stereolithographic model fabricated according to a real patient situation. The model was fitted with strain gauges on the "bone" distal and medial to the implants and with vertical force transducers in the alveolar "bone" under the denture-bearing area. The parallel-sided rigid telescopic connector developed the highest moment loading of the implant (P<0.001), which would suggest restraint in the use of this connector. The bar construction also showed somewhat high moments but these may have been at least partly exaggerated by the individual patient situation. Loading results through the non-rigid telescopic copings, single spherical attachments and magnet overdentures demonstrated a low level of implant moment loading which would in part result from horizontal forces caused by denture forward shift during force application. The denture-bearing area loading was different with all attachments (P<0.001) and was related to the rigidity of the connector and reached the highest values with the non-rigid telescopic coping. The clinical implications of the various findings are discussed.

Alveolar Process↗

Temporal backward projection of optoacoustic pressure transients using fourier transform methods.

In medical imaging different techniques have been developed to gain information from inside a tissue. Optoacoustics is a method to generate tomography pictures of tissue using Q-switched laser pulses. Due to thermal and pressure confinement, a short light pulse generates a pressure distribution inside tissue, which mirrors absorbing structures and can be measured outside the tissue. Using a temporal back-projection method, the pressure distribution measured on the tissue surface allows us to gain a tomography picture of the absorbing structures inside tissue. This study presents a novel computational algorithm, which, at least in principle, yields an exact reconstruction of the absorbing structures in three-dimensional space inside the tissue. The reconstruction is based on 2D pressure distributions captured outside at different delay times. The algorithm is tested in a simulation and back-projection of pressure transients of a small absorber and a single point source.

Acoustics↗

Clinical outcomes of three Parkinson's disease patients treated with mandibular implant overdentures.

Parkinson's disease (PD) often affects the oro-pharyngeal musculature, leading to problems with speaking, chewing and swallowing. The inevitable reduction in food and fluid intake contributes to the further deterioration of neurological symptoms. Parkinson's disease patients have great difficulties in adjusting to the use of complete dentures. It is the purpose of this report to evaluate the benefit of using dental implants combined with overdentures to improve chewing and predigestion capacity in severely handicapped PD patients. Three edentulous PD patients (2 male, 1 female; mean age 75.7 years; mean PD duration 4.3 years; PD severity grade III according to Hoehn and Yahr; mean edentulousness 19.3 years) complaining of poor chewing ability were included in this evaluation. One-stage dental implants were placed in the interforaminal region of the mandible. After completion of healing, new overdentures were fabricated. Custom-made non-rigid (resilient) telescopic attachments were used for retention of the overdentures on the implants. Follow-up examinations of the 3 patients were made between 28 and 42 months after the completion of treatment, and peri-implant tissue conditions as well as the patients' self-assessed satisfaction level were recorded. A modified gastrointestinal symptoms questionnaire, Hoehn and Yahr Scale and body weight measurements were used to monitor gastrointestinal impairment and PD severity. The peri-implant parameters indicated healthy soft tissue conditions and all Periotest values were in the negative range. The patients judged their chewing abilities to be greatly improved. Since placing the implants, PD severity had deteriorated to grade IV (Hoehn and Yahr scale) in 2 patients and was stable in 1 patient. The body weight had improved slightly in all patients (mean 2.2 kg). On the gastrointestinal scale, all patients had improved from a mean score of 8.7 to 5.7. Non-rigid telescopic attachments for overdenture stabilization are particularly suitable for PD patients as they are easy to handle and to clean. The patients reported remarkable improvement in their chewing ability, an assessment which would seem to be supported by the improved gastro-intestinal index. The regimen described appears to be a useful adjunctive treatment in edentulous Parkinson's disease patients and may be considered for patients with diseases similarly affecting motor skills.

Aged↗

Effect of osseointegrated implants on the coordination of masticatory muscles: a pilot study.

STATEMENT OF PROBLEM: The neuromuscular network of masticatory function is, in part, coordinated with afferent information provided by the periodontal ligament (PDL). Osseointegrated implant-supported prostheses lack this PDL-derived proprioceptive feedback mechanism. PURPOSE: This pilot study was designed to address the hypothesis that implant patients acquire different patterns of functional coordination. Patients with implant-supported prostheses were characterized in regard to masticatory muscle tenderness and fatigue as well as changes in the coordinated activities of masticatory muscles during chewing and maximal occluding force. Results were compared with those of patients with natural teeth and interpreted to assess the functional outcome of implant therapy. MATERIAL AND METHODS: Fifty-seven volunteers (25 partially edentulous patients restored with implantsupported fixed prostheses; 32 control patients) were evaluated. A comprehensive set of clinical examinations was performed, including occlusal analysis and examination of masticatory muscle and TMJ. EMG recordings of 5 volunteers from each group were further evaluated. EMG activities of the masseter and anterior temporalis were recorded during habitual chewing and voluntary maximal occluding force. RESULTS: There were essentially no differences in the clinical evaluations between volunteers in the implant and control groups and no significant alterations in the masticatory muscle coordination for habitual chewing. During the maximal occluding force measurement, EMG recordings revealed a unique masticatory muscle coordination pattern in the implant group with a tendency to activate the working and nonworking side muscles simultaneously. CONCLUSION: Patients with implant-supported prostheses appeared to be well adapted to perform habitual masticatory functions. However, during a nonhabitual function such as maximal occluding force, our pilot data revealed a less coordinated masticatory muscle activity in the implant patients.

Adaptation, Physiological↗

A 5-year prospective clinical and radiographic study of non-submerged dental implants.

Osseointegrated implants as anchors for various prosthetic reconstructions have become a predictable treatment alternative. It was expected that implants required submucosal placement during the healing period for successful tissue integration. However, it has been demonstrated that healing and long-term health of implants could be achieved with equal predictability in a 1-stage, non-submerged approach. This prospective 5-year study not only calculates implant success by life table analysis, but also evaluates the correlation between observed bone level changes with clinical parameters as measured by suppuration, plaque indices, bleeding indices, probing depth, attachment level and mobility. A total of 112 ITI dental implants were inserted in different areas of the jaws. Clinical and radiographic parameters were evaluated annually for 5 years, whereas a portion of the study group for which 6-year evaluations were available were included in the life-table analysis. The overall success rate after 5 years in service was 99.1%, while after 6 years it was reduced to 95.5% due to the fracture of 3 implants in 1 patient. The mean crestal bone loss experienced during the first year was 0.6 mm followed by an annual yearly loss of approximately 0.05 mm. No significant differences could be found between the amount of bone loss measured at each of the yearly follow-up visits. This suggests that statistically the followed implants did not show any radiographically measurable bone loss following the initial period of bone loss associated with implant placement and osseointegration. Low levels of correlation between the individual and cumulative clinical parameters with radiographically measured bone loss suggests that these parameters are of limited clinical value in assessing and predicting future peri-implant bone loss.

Alveolar Bone Loss↗

A five-year evaluation of implants placed in extraction sockets.

The aim of this study is to examine extraction socket implant longevity and peri-implant conditions longitudinally and to compare the outcome with implants placed in intact alveolar bone sites (nonextraction sites) after a time period in function of five years or more. We hypothesize that implants placed into fresh extraction sockets have a long-term rate of success similar to that of conventionally placed implants. Eleven extraction socket implants in eight patients with a follow-up of at least five years were included in this report. The implants were loaded with either single-tooth replacements or three-to-four-unit fixed partial dentures after healing times of four to six months. Intraoral radiographs of the 11 implants were obtained immediately after surgery and upon recall five to seven years after surgery. In addition, the following clinical parameters were evaluated at each implant site five to seven years postsurgery: plaque indices (PT), bleeding indices (BI), probing depths, attachment level (AL), and distance from implant shoulder to mucosal margin (DIM). As a control, 11 implants from a previous long-term study of nonsubmerged implants placed into intact alveolar bone sites by the same clinician were matched by implant location, sex, and age. Initial and long-term follow-up radiographs of the experimental and control groups were scanned into a computer. A computer program designed for radiographic implant analysis was utilized to examine the changes in radiographic bone levels over time in the two groups. After a period of five to seven years, the mean bone loss for the immediate implant group was 0.167 mm, while that of the control group was 0.460 mm. An unpaired t-test resulted in a P value = 0.0563, indicating that the mean change in bone levels between the two groups is not statistically significant. In addition, clinical evaluation parameters (PI, BI, AL, DIM) revealed no significant difference between the two groups. Therefore, it can be stated that in this study the long-term success rate for extraction socket implants is similar to that of conventionally placed implants.

Adult↗

Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs.

STATEMENT OF PROBLEM: Immediate loading of implants may be a predictable treatment alternative when cross-arch stabilization with a fixed provisional is observed. PURPOSE: This study investigated the effect of immediate masticatory loading on the stability of single-standing dental implants with 4 different surfaces. MATERIAL AND METHODS: A total of 40 solid screw implants (diameter 3.3 mm, length 8 mm) were placed in the mandibles of 4 beagle dogs. Test groups included 3 hydroxyapatite (HA) coatings of titanium plasma-sprayed (TPS) implants. Implants with TPS alone served as control. Gold crowns were inserted 2 days after implant placement and the dogs were immediately put on a hard food diet. Implants were followed for 6 months after loading. Clinical and radiographic assessments of implants were performed at time of crown insertion (baseline) and after 1, 3, and 6 months of loading. The Periotest instrument was used for mobility measurements and radiographs were obtained for evaluation of peri-implant radiolucency and measurement of crestal bone changes. RESULTS: Of 40 implants, 39 displayed no discernible mobility, corresponding to successful clinical function. Peri-implant radiolucencies were absent for all but the 1 mobile implant. The reduction in crestal bone levels adjacent to the implants between baseline and 6 months was statistically significant (P <.0001). No statistically significant differences in crestal bone level changes over time were found between the various coatings demonstrating the absence of a treatment effect initiated by the surface coatings. CONCLUSION: In this study in beagle dogs, immediate masticatory loading of single-standing dental implants did not jeopardize tissue integration, provided the implants had excellent primary stability.

Analysis of Variance↗

Advantages and dangers of erbium laser application in stapedotomy.

Among different types of lasers, the erbium laser exhibits particularly favourable characteristics for ear surgery. Experiments with application of erbium laser pulses to the isolated stapes connected to an inner ear model confirmed that there was virtually no thermal effect to the inner ear liquid and that the border damage zone on the stapes footplate perforation did not exceed 5-10 microm. Erbium laser pulses, however, produce pressure waves due to the explosive ablation of tissue. Pulses of 10 to 17 J/cm2 producing pressure waves between 140 and 160 dB appear to be a limit for clinical application. With these criteria, an in-house built erbium YAG laser with a fiberoptic delivery device was used in 15 patients for stapedotomy. A special microhandpiece, where a zirconium fluoride fiber was connected to a quartz tip, was developed. In addition, three patients had stapedotomy with a commercially available Zeiss (Opmi TwinER) microscope equipped with a micromanipulator-operated erbium laser beam. One year after surgery, the air-bone gap was closed in all patients to within 20 dB between 0.5 and 3 kHz with only minor permanent bone conduction threshold losses (< 20 dB). However, we observed an immediate postoperative middle and high frequency loss of up to 75 dB on bone conduction threshold measurements 2 h after surgery, suggesting an acoustic traumatization by the erbium laser. This threshold shift recovered close to preoperative values within 6 h. These observations prompted us to discontinue the clinical use of erbium laser for stapedotomy until the problem of temporary acoustic traumatization is resolved.

Adult↗

The effect of insulin therapy on osseointegration in a diabetic rat model.

As patients become edentulous, dental implants have been one treatment alternative. Although studies indicate that dental implants inserted in healthy patients have been successful, their placement in the diabetic patient remains controversial. The purpose of this study utilizing histometric parameters compares the course of osseous healing around endosseous implants in normal non-diabetic and insulin controlled diabetic rats. Diabetes was induced by a single intraperitoneal injection of streptozotocin. Blood glucose was monitored by the glucose-oxidase method and controlled with daily insulin injections. Sterile custom fabricated commercially pure solid cylinder titanium implants, with a titanium plasma-sprayed surface were placed in the femora of each animal. The results indicate that insulin therapy was able to upregulate the formation of bone around implants inserted in the streptozotocin-induced diabetic rat model. However, histometric parameters utilized indicated that although the total quantity of bone formation was greater in the insulin controlled group, there was significantly less bone-to-implant contact in the insulin controlled diabetic group as compared to normal non-diabetic controls.

Animals↗

Pre- and post-implantation microbiota of the tongue, teeth, and newly placed implants.

OBJECTIVES: This investigation sought intra-oral sources of species colonizing dental implants. MATERIALS AND METHODS: Plaque samples were taken pre- and post-successful osseointegration from implants, teeth, and from tongues of 10 edentulous and 11 partially dentate subjects. Samples were assayed using whole genomic DNA probes in a checkerboard assay to 42 subgingival species. RESULTS: Similar prevalences and mean levels (10(3) to 10(4)) of microorganisms colonized implants and teeth. Species levels from tongue samples were higher than those of teeth and implants, although species prevalence was similar, suggesting that larger samples were obtained from the tongue. No significant differences were observed between the microbiota from the tongue of edentulous and partially dentate subjects. Most implant species were detected on tongue pre-implantation. In individual edentulous subjects, there were positive associations between Capnocytophaga ochracea and Campylobacter rectus from tongue and implant samples. In individual partially dentate subjects, there were positive associations between Fusobacterium nucleatum subsp. vincentii from tongue and implant samples, and Treponema denticola from implant and tooth samples taken at the same visit. CONCLUSION: This study indicated that the tongue, in addition to teeth, can be a source for species colonizing new implants.

Adult↗

Microbiota of successful osseointegrated dental implants.

BACKGROUND: The long-term survival of dental implants depends, in part, on control of bacterial infection in the peri-implant region. Periodontal pathogens colonized implants symptomatic through infection, whereas the microbiota of successful implants was similar to that of periodontal health. This study examined the impact on the peri-implant microbiota of crown restorations; implant type; length of time of loading; history of implant or periodontal infections; and whether implants replaced single or multiple teeth. It was of particular interest to evaluate implant colonization by species in a newly described red complex of periodontal pathogens, Porphyromonas gingivalis and Bacteroides forsythus. METHODS: This study sampled 43 partially edentulous subjects with successfully osseointegrated titanium root-form dental implants. Eighty-one (81) non-submerged and 20 submerged asymptomatic implants, 83 crowned, and 36 uncrowned teeth were sampled from peri-implant or subgingival sites. The microbiota of samples was evaluated using whole genomic DNA probes in a checkerboard assay to 23 subgingival species. RESULTS: Implants were colonized principally by oral streptococci, capnocytophagae, Veillonella parvula, Peptostreptococcus micros, and Fusobacterium nucleatum. The periodontal species, P. gingivalis, B. forsythus, Prevotella intermedia, Prevotella nigrescens, and Campylobacter rectus were detected in a few subjects. The microbiota around crowned implants and crowned teeth was similar. Streptococcus oralis, P. intermedia, and Selenomonas noxia were elevated in samples from uncrowned teeth compared to crowned teeth and implants. Microbial complexity increased as loading time increased, but colonization by periodontal pathogens, including red complex species, was higher in subjects with previous periodontal disease. No differences were observed in the microbiota of 1- and 2-stage implants, or between implants supporting single or multiple restorations. CONCLUSIONS: While presence of crowns had only a minor impact on the peri-implant microbiota, microbial changes were observed the longer the implants had been in function and in those patients with a history of periodontal or peri-implant infections. A history of periodontitis had a greater impact on the peri-implant microbiota than implant loading time. The major influence on the peri-implant microbiota was, however, the microbiota on remaining teeth. P. gingivalis and B. forsythus, red complex periodontal pathogens, colonized several implants, although all implants were successfully osseointegrated.

Adult↗

A radiographic evaluation of bone healing around submerged and non-submerged dental implants in beagle dogs.

BACKGROUND: The rehabilitation of the oral cavity with dental implants has become a predictable treatment modality. However, there have been only a few direct comparisons evaluating the submerged and nonsubmerged placement techniques. The purpose of this study was to characterize radiographic peri-implant bone changes following the insertion of submerged and nonsubmerged implants in the beagle dog. METHODS: At the end of the extraction healing phase, 19 submerged and 19 nonsubmerged implants were randomly placed in a split-mouth study design and observed over an 18-week period. For submerged implants, a second stage surgery and transmucosal abutment attachment was performed at week 12. Standardized dental radiographs taken at baseline, week 12, and week 18 were used to measure peri-implant bone changes. The radiographs were analyzed with a simple computer assisted method. RESULTS: A total of 43 standardized radiographs were exposed to evaluate the 38 implants. During the study period, all submerged and nonsubmerged implants demonstrated peri-implant bone loss. At baseline, both submerged and nonsubmerged implants had similar bone levels (P > or = 0.05). When the mean peri-implant bone levels for submerged and nonsubmerged implants were compared from baseline to week 12, nonsubmerged implants had a significantly greater amount and rate of bone resorption than submerged implants (P < or = 0.05). Following week 12, the initially submerged implant had a significantly higher rate and amount of peri-implant bone loss than the nonsubmerged implants (P < or = 0.05). However, by the end of the study period, week 18, both submerged and nonsubmerged implants had comparable bone levels (P > or = 0.05). CONCLUSIONS: The study indicates that, although the temporal patterns of peri-implant bone resorption differed, there were no differences between submerged and nonsubmerged implants in the overall amount and rate of peri-implant bone loss.

Alveolar Process↗