PubMed · 15519594

A time-dependent healing function for immediate loaded implants.

Abstract

Current interest in immediate dental implant loading has grown due to a number of clinical advantages this treatment modality offers. To obtain a deeper insight into the changing mechanical properties during the healing phase, results from removal torque tests are used in a biomechanical model. The ultimate removal torques, which depend on healing time, are described by a time-dependent healing function. The bone behavior is modeled using an elastic law with damage. The evolution of damage is represented with an incremental equation with an initial damage value and two material parameters. The nonlinear relationship between the torque and the angle of rotation up to the ultimate torque can be calculated. By changing the elastic parameter in the elastic damage law, the remodeling process can be characterized. In a further step, the elastic parameters and the limits for shear stress from the biomechanical model for the removal torque will be used in an FE analysis in order to obtain information on the axial loading limits of a dental implant at different healing times.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Winter, S M Heckmann, H P Weber. 2004. A time-dependent healing function for immediate loaded implants.. https://doi.org/10.1016/j.jbiomech.2004.02.033

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Buckling of swelling gels.

The patterns arising from the differential swelling of gels are investigated experimentally and theoretically as a model for the differential growth of living tissues. Two geometries are considered: a thin strip of soft gel clamped to a stiff gel, and a thin corona of soft gel clamped to a disk of stiff gel. When the structure is immersed in water, the soft gel swells and bends out of plane leading to a wavy periodic pattern whose wavelength is measured. The linear stability of the flat state is studied in the framework of linear elasticity using the equations for thin plates. The flat state is shown to become unstable to oscillations above a critical swelling rate and the computed wavelengths are in quantitative agreement with the experiment.

Biomechanical Phenomena↗

Knee joint mechanics under quadriceps--hamstrings muscle forces are influenced by tibial restraint.

BACKGROUND: To investigate the role of quadriceps and hamstrings muscle recruitments on knee joint mechanics, measurement studies constrain the tibial anterior-posterior translation at a point away from the joint. This generates a restraining force perpendicular to the tibia thus introducing an artefact shear force that likely alters joint mechanics and forces in cruciate ligaments. METHODS: A 3D nonlinear finite element model of the entire knee joint, including tibiofemoral and patellofemoral joints, was used to investigate joint mechanics in flexion (0 degrees -90 degrees ) under isolated and combined hamstrings and quadriceps activation. The effect of tibial restraint at two locations on results was studied and compared with the reference boundary condition of tibia constrained by pure moments. FINDINGS: Tibial restraint by a force rather than a pure moment substantially influences the joint response. For identical forces, hamstrings have much greater moment generating capacity at larger flexion angles while quadriceps are more effective at smaller angles. INTERPRETATION: Tibial constraint by a restraining force rather than a pure moment causes an artefact force on the joint that vary with muscle forces and restraining location. These artefact shear forces, especially when placed closer to the joint, considerably reduce forces in cruciate ligaments; in anterior cruciate ligament at near full extension and in posterior cruciate ligament at larger flexion angles. The beneficial effects of muscle co-contraction in reducing anterior cruciate ligament forces at near full extension and in posterior cruciate ligament forces at near 90 degrees , however, disappear as the restraint on the tibia approaches the joint. The artefact forces could distort results and their interpretations.

Biomechanical Phenomena↗