Shielded biplanar gradient coil design.

An application of the target field method to the design of shielded biplanar gradient coils for magnetic resonance imaging electromagnets is presented. Some specific cases are studied, and optimized geometries are proposed for the axial and transverse gradient coils that eliminate the third- and minimize the fifth-order terms in the magnetic field expansion.

Electromagnetic Phenomena↗

Fast optimization of a biplanar gradient coil set.

This work presents an approach for fast optimization of gradient coils, using the simulated annealing method. The shielding condition derived from a target field method and the analytical evaluation of the fields produced by simple geometries were used to reduce the computing time. This method is applied to the optimization of a shielded biplanar gradient coil set. Efficiency, inductance, and homogeneity of the gradient fields produced by the optimized geometries were studied as a function of the number of wires, for the longitudinal and transverse gradient coils. A prototype of the gradient set was made to test the proposed design method. The resulting experimental values of coil efficiency, inductance, field linearity, and shielding performance exhibit good agreement between theory and experiment.

Magnetic Resonance Spectroscopy↗

Magnetic fields mapping with the phase reference method.

A simple method for imaging the magnetic field produced by arbitrary current distributions is presented. The method is based on the use of a phase reference image and can be easily adapted to any standard magnetic resonance imaging scanner. Examples are given to application to gradient coil characterization and quantitative field measurements.

Magnetic Resonance Imaging↗

Use of a Phase Reference for Field Mapping with Amplitude Images at Low Field

We present a method to obtain MRI amplitude images that can picture the magnetic field due to arbitrary shaped magnetized objects. The method employees the gradient recalled echo sequence and two sets of data obtained in separate experiments, one of which provides a phase reference image making it possible to eliminate the effect of the B0 field inhomogeneities. The final magnitude images have a good signal-to-noise even at low fields, and provide qualitative as well as quantitative information about the magnetic field produced by the ferromagnetic object. As an example the method is applied to study the field produced by a small metal piece in a 500-G scanner, and the experimental results are compared with numerical simulations. Copyright 1998 Academic Press.

Journal Article↗