PubMed Health⌕ Search

Biomedical subjects

H Rousseau

Publications and source records attributed to H Rousseau.

120 records · Page 7Linked to original sources

Middle mesenteric artery visualized by computed tomographic angiography.

The middle mesenteric artery, a third mesenteric artery arising from the aorta that principally feeds the transverse colon, is an extremely rare anomaly. We identified a middle mesenteric artery branching into the ileocolic artery and into the right, middle, and accessory middle colic arteries. It supplied the cecum and the entire ascending and transverse colon. This anomaly was detected with computed tomographic angiography.

Angiography, Digital Subtraction↗

In vitro evaluation of a new rotational thrombectomy device: the Straub Rotarex catheter.

PURPOSE: To evaluate the efficacy of a new rotational thrombectomy device, and the procedure-related risk of particle embolization. METHODS: The experiments were performed in transparent silicone tubes. The conditions of flow were as close as possible to physiological parameters. Distal embolization was detected by a mesh of nylon filters. RESULTS: The Straub Rotarex catheter was able to remove all clots. The mean number of migrating particles larger than 1000 microm was 0.17 (+/- 0.38), the mean number of 400-1000 microm migrating particles was 1.08 (+/- 1.04). The mean intervention time was 67 (+/- 37) sec. The mean volume of collected liquid was 96.6 (+/- 24.7) ml. CONCLUSION: The in vitro results suggest that the Straub Rotarex catheter is able to remove large volumes of thrombus with a limited risk of embolization. The main limitation of our model is the absence of adhesion of the clot to the tube.

Catheterization↗

Noncovered stent placement in a blunt traumatic injury of the right subclavian artery.

We report a case of scapulothoracic dissociation with right subclavian artery traumatic injury that was managed by endovascular treatment. Particular features are the use of a flexible self-expandable noncovered stent and simultaneous protection of the right common carotid artery from distal embolization by inflating a balloon catheter.

Angiography↗

Imaging features of uncommon adrenal masses with histopathologic correlation.

Uncommon adrenal masses include cystic lesions (hydatid cyst, endothelial cyst), solid lesions (hemangioma, ganglioneuroma, angiosarcoma, primary malignant melanoma), and solid fatty lesions (myelolipoma, collision tumor). Most of these lesions do not have specific imaging features. The liquid content of adrenal cysts is clearly demonstrated on ultrasonographic scans, computed tomographic scans, and magnetic resonance images. Nevertheless, the histologic type cannot be predicted except at some stages of hydatid disease in which pathognomonic features are present. The most typical imaging features of hemangioma are phleboliths and enhancement of peripheral vascular lakes. Ganglioneuroma has nonspecific radiologic features, but this diagnosis should be considered in cases with early enhancement of fine septa and progressive filling. The radiologic features of angiosarcoma and primary malignant melanoma are nonspecific. A macroscopic lipid content within an adrenal mass is theoretically characteristic of myelolipoma. This diagnosis should be made with caution, especially when the lipid content is not predominant, because of the possible association with an adenoma.

Adenoma↗

In vitro evaluation of the embolic risk of diagnostic and therapeutic intravascular procedures.

BACKGROUND: The purpose of the study was to evaluate the risk of distal embolisation in a silicon model during different endovascular diagnostic and therapeutic procedures. MATERIAL AND METHODS: Endovascular technics, such as guidewire and catheter advancement, metal stent placement and balloon angioplasty were compared. Clots were produced from human blood sample. The transparent silicon model was filled with saline, flow was generated by an hydraulic pump. Stenosis was created by mechanical compression. The size of the circulating particles were measured with a mesh of nylon filters. RESULTS: No loose particles were detected using guidewire, pigtail and straight catheters. Balloon inflation induced embolisation of particles ranging from 100 microns to 10 mm in length. Deployment of self expandable metallic stents did not result in particle migration but secondary angioplasty inside the stent detached particles (ranging from 400 microns to 12 mm in length). Deployment of balloon expandable stent yielded in the stretching of the clot, which became sometimes longer than the stent, resulting in the detachment of the non covered portion. CONCLUSION: The risk of distal embolisation during guide-wires and catheters manipulation is not significant. Balloon catheters and secondary angioplasty after deployment of self-expanding stents caused large particles detachment.

Angioplasty, Balloon↗

Percutaneous vascular stent: experimental studies and preliminary clinical results in peripheral arterial diseases.

A new pattern of metallic intravascular stent has been experimentally and clinically tested. When the stent is percutaneously placed through a six french introducer, it is held against the vessel wall by its natural elastic properties. In 28 animals, 47 stents of different sizes (from 3 to 5 mm of luminal diameter and from 1.5 to 5 cm of length) have been implanted in the femoro-popliteal (16), the coronary (20), the carotid (3) and the renal arteries (5) and in 3 femoral veins. Angiographic and histological results have shown the stent's low thrombogenicity when it is well fit to the vessel's caliber. Moreover, they have shown its incorporation to the vessel wall by intimalisation as early as the third week after its implantation. The collateral vessels which covered by the stent remain permeable. At the end of this experimentation, 10 implants have been achieved in 8 patients (4 recurrences of iliac stenosis and 6 femoral stenosis). The angiographic results show the perfect tolerance of the organism at 6 months. This good tolerance is revealed by a thin intraluminal border which does not change the artery's diameter. This confirms the experimental results. The permeability is good except for two patients who had an obliteration after one month (one iliac and one femoral obliteration).

Angioplasty, Balloon↗

Transjugular intrahepatic portosystemic shunts using the Wallstent prosthesis: a follow-up study.

PURPOSE: The aim of the present study was to assess the efficacy of transjugular intrahepatic portosystemic shunts (TIPS) in 45 patients with cirrhosis during a mean follow-up of 7 months. METHODS: Forty-five consecutive patients treated by TIPS and who had been followed for at least 6 months after TIPS or until death, were included. Mean follow-up was 7.2 +/- 5.0 months. Shunt patency was assessed at 1 week and 1 month, then every 3 months after the procedure by Doppler US and angiography whenever needed. RESULTS: Thirty-six patients had been stented for refractory bleeding from ruptured esophagogastric varices. Of these, 8 patients (22%) rebled, 7 of whom were treated by a second shunt. Nine patients were treated for refractory ascites. Three patients had recurrent ascites due to shunt obstruction. All were treated by a second shunt which occluded in 2 patients. As a whole, 14 (31.1%) patients developed shunt obstruction within a mean of 120 +/- 136 days, 4 of whom remained asymptomatic. Other complications were septicemia by Staphylococcus aureus in 1 patient, transient encephalopathy in 9 patients, and disseminated intravascular coagulation in 1 patient. CONCLUSIONS: TIPS appears to be a relatively safe and effective technique in treating complications of portal hypertension in patients with cirrhosis. Shunt obstruction in 31% of our patients probably represents the most important limitation of this technique.

Ascites↗

[Intra-aortic covered endoprosthesis].

Because of the risk and complications related to surgery of the aorta, the development of new, less invasive endovascular techniques has resulted in a certain enthusiasm for these new treatments on the part of physicians and industry. The insertion of aortic stents allows the treatment of almost one half of aneurysm of the infrarenal abdominal aorta and descending aorta. The results appear to demonstrate the medium-term reliability and efficacy of these new techniques with a lower morbidity-mortality rate than that of conventional surgery. However, preoperative and intraoperative imaging plays an essential role in the success of these new methods. Finally, although the medium-term results are encouraging, the long-term outcome of these new materials is unknown, which justifies close surveillance of these patients and prospective comparative studies.

Aneurysm, Ruptured↗