[The omitted x-ray examination--benefit and risk--a comparison].

Today the risk of omission of an x-ray examination is often underestimated compared with the assumed stochastic - i.e. random - risk of radiation exposure associated with the x-ray examination. The benefit of the x-ray examination can be estimated by considering how it influences the diagnostic decision and the therapy. Three degrees of justification (indication) supply proof of different degrees of the proportion of benefit gained. It is evident that some of the x-ray examinations that are being performed, are unnecessary, whereas on the other hand even so-called routine x-ray examinations can yield a therapeutically relevant finding in some patients. A comparison of benefit and risk shows that the estimated benefit exceeds the assumed irradiation risk by several orders of magnitude. This is exemplified by examinations of the thorax and lumbar vertebral column. The guidelines issued by the German Federal Chamber of Physicians on quality assurance in x-ray diagnostics and CT result in a considerable reduction of patient doses. Advantage must be taken of the benefit of x-ray examinations performed with an extremely critical eye on the relevant indication and with minimised irradiation exposure. Omitting an indicated examination may endanger the patient to such an extent that major neglect of the irradiation risk is warranted.

Humans↗

Impact of hard-copy size on observer performance in digital chest radiography.

To determine the impact of reduced hard-copy size on diagnostic performance of digital radiography, screen-film chest radiographs were compared with isodose digital storage phosphor radiographs in the detection of simulated nodules, fine pulmonary lines, and micronodular opacities superimposed on the chests of 10 healthy volunteers. Digital radiographs were laser-printed in a full-size conventional format and in image lengths of two-thirds, one-half, and five-elevenths of the conventional format. Eighteen thousand observations by eight radiologists were analyzed by use of receiver operating characteristics. The detectability of lines and micronodular opacities decreased with declining image format size. In the detection of micronodular opacities, only the nearly full-size digital images were equivalent to conventional images. In the detection of linear opacities, reduction of image length by one-half or more reduced performance (analysis of variance, P less than .05). Only for the detection of nodules was no major difference found.

Humans↗

[Quality control of film viewing boxes].

Film inspection boxes have been examined in order to find out whether the introduction of the Roentgen regulation has led to positive results with regard to amount, illuminating density and homogeneity. In comparison to former results which have been published, it seems that the illuminating density is still too low. On the average, we found a value of 1.700 cd/m2.

Germany↗

[Are conventional roentgen technics for tbc diagnosis still acceptable?].

Image quality in chest radiography has to be high enough that even subtle pulmonary abnormalities can be easily visualised. Conventional screen/film radiographs obtained with 200 to 400 speed systems fulfil this requirement well enough. Large screen and slit beam image intensifier systems that have replaced fluoroscopy screens, yield equivalently good results. The amber system and storage phosphor digital radiography systems are efficient alternatives. Radiation exposure is generally low and decreased further if image intensifiers are used. Conventional technique with highly sensitive film/screen combinations has been approved for diagnosis of pulmonary tuberculosis.

Humans↗

[Effect of observation time on the perception of details in x-ray pictures].

The authors studied the influence of perception time on the quantified image quality of radiographs, using as an experimental basis the target presentation time during which there was no active involvement of the observer. No change in the influence on the observer was seen down to an observation time of 1 sec.; there was a slight but practically negligible drop on further reduction to 0.5 sec. At 0.1 sec. there was a drop that would have been approximately compensated by a contrast enhancement of object detail to about twice the original value. The influence of the perception time was placed in relation to an example of the influence of structured noise on the detection performance. This influence proved to be significantly greater than that of time. A comparison of the concept of "conspicuity" as defined by Revesz and Kundel was set in relation to the term "Auffälligkeit" ("distinctiveness") coined by Stender. It was established that the quality reserve QR after Borcke corresponds to "Auffälligkeit" as defined by Stender and should best be separated from image quality changes dues to the influence of structured noise on the detection of radiological abnormalities.

Humans↗

[Implementing quality assurance in roentgen diagnosis in accordance with the new roentgen ordinance].

Image quality and radiation protection can be optimised by means of quality assurance testing in accordance with the new Federal German regulations governing the handling of x-ray equipment (functional testing and control of constancy of performance). The x-ray films of patients are examined according to quality criteria relating to the organs of which x-ray films are produced; the diagnostic pointers obtained from these x-ray films enable on-target counselling, taking into consideration the technical guidelines on the taking of x-ray films to produce best possible results.

Humans↗

Reduced intestinal protein loss in Crohn's disease after lymphovenous anastomosis.

In a 27-year-old patient suffering from Crohn's disease covering nearly the entire small intestine, the major problem was a marked protein-losing enteropathy which required long-term intravenous replacement. Accidentally, we disclosed a dilated thoracic duct with incompetent valves and stenosis at the junction into the subclavian vein in this patient. To reduce the intestinal protein loss, an anastomosis was performed between the thoracic duct and the internal jugular vein. Subsequently the intestinal protein loss dropped from 40 to 26% and replacement of proteins could be reduced. The patient was observed for 4 years postoperatively and the therapeutic effect continued. Besides this therapeutic aspect, the present case gives cause to consider the possible role of the lymphatics in the pathogenesis of Crohn's disease.

Adult↗

[Image quality assurance in x-ray diagnostic units. Information on DIN 6868 standard series].

The Working Group for Standardisation justifies and comments on the establishment of a standard series for image quality assurance in X-ray diagnostic services (DIN 6868). In order to promote compliance with these standards, the users are given some background information on the structure of the standard series and on the recommended procedures to be followed. The definitions for the various hierarchically arranged tests, such as constancy test, status test, acceptance test as well as a definition for the term "base-line image quality" are explained.

Germany, West↗

Value and limitations of computed tomography in assessing aortocoronary bypass graft patency.

To determine the value of nondynamic computed tomography (CT) in assessing aortocoronary bypass graft patency, we studied 67 patients with 125 grafts by CT and by coronary angiography at close time intervals. CT scans were performed before and after one to three (average 1.98 +/- 0.65) 50-ml i.v. bolus injections of contrast material. Eighty-four of 92 grafts patent at angiography were also visualized by CT (sensitivity 91.3%); 29 of 33 grafts closed at angiography were considered to be occluded by CT (specificity 87.9%). Eleven of 13 grafts demonstrating one or more severe obstructions at angiography were considered to be patent by CT. Interobserver disagreement existed in four of 125 grafts (3.2%) and intraobserver variability was 1.6%. Although nondynamic CT allows a correct assessment of graft patency in many cases, it does not provide sufficient information on graft stenosis and function to replace angiography in patients who are symptomatic after surgery.

Adult↗

[Technique of the x-ray examination of the lungs (author's transl)].

Thorax radiography with high kilovoltage technique in 2 planes is the basis for lung examination. In case of special on-target problems additional x-ray films will be necessary. The aim must always be to obtain an image of the details which are essential for proper diagnosis, showing the fine structures of the relevant area. Among the important image parameters are the visualisation of the fine vessels in the lung periphery and on the costopleural margin from the apex of the lung to the diaphragm; the sharp image of the central pulmonary vessels, of the cardiac margin and the diaphragm; and the recognisability of the retrocardiac vessels. The article discusses the anatomicophysiological conditions, the technical requirements and the demands to be made on the medical assessment of the findings.

Alveolitis, Extrinsic Allergic↗

[X-ray manifestation of early gastric carcinoma (author's transl)].

Evaluation of x-ray films of 44 early carcinomas of the stomach in a total of 163 patients from 1970--1978 confirms the high diagnostic value of x-ray examination with adequate technique. In 93% of the cases lesions caused by the carcinoma were seen. To assess the severity of the roentgenologically detected lesions it will be necessary to perform endoscopic-bioptical examination. Final diagnosis, however, must be left to histological examination of the resected stomach preparations.

Humans↗