[MR-based methods of the functional imaging of the central nervous system].

This review presents the basic principles of functional imaging of the central nervous system utilizing magnetic resonance imaging. The focus is set on visualization of different functional aspects of the brain and related pathologies. Additionally, clinical cases are presented to illustrate the applications of functional imaging techniques in the clinical setting. The relevant physics and physiology of contrast-enhanced and non-contrast-enhanced methods are discussed. The two main functional MR techniques requiring contrast-enhancement are dynamic T1- and T2*-MRI to image perfusion. Based on different pharmacokinetic models of contrast enhancement diagnostic applications for neurology and radio-oncology are discussed. The functional non-contrast enhanced imaging techniques are based on "blood oxygenation level dependent (BOLD)-fMRI and arterial spin labeling (ASL) technique. They have gained clinical impact particularly in the fields of psychiatry and neurosurgery.

Animals↗

[Teleradiology: economic research analysis of CT investigations in a small hospital].

PURPOSE: To evaluate, discuss and compare economic aspects of teleradiological applications in CT examinations in a small hospital. Scenario (1): CT examination by an extern institution including transport of a patient. Szenario (2): External consultation of an internal CT examination (teleradiology according to ROV). Scenario (3): Complete in-house radiology department. To evaluate economic aspects of teleradiology service providers. MATERIALS AND METHODS: Costs have been separated into fixed and variable costs in a model. Total costs of 500 CT examinations per year have been calculated for the three scenarios. A break-even analysis has been performed to determine the necessary/minimal number of CTs per year for economical advantages. The number of CT consultations for teleradiology service providers to make profit has been calculated. RESULTS: Scenario (1): This is the most cost-effective scenario for 500 CTs per year, but most time-consuming. Beyond 548 CTs per year using a single slice CT and 965 CTs per year using a multislice CT the teleradiology scenario [scenario (2)] is most cost-effective. Beyond 1065 CTs per year an in-house radiology department [scenario (3)] is economically reasonable. On the basis of 30 Euros per CT consultation a teleradiology service providing system will be profitable starting from 322 CT consultations per year. CONCLUSION: Teleradiology applications are economically reasonable in a wide range in small hospitals. CT teleradiology services can also be provided on a cost-effective basis at a reachable number of consultations.

Cost-Benefit Analysis↗

[Multidetector CT for the diagnosis of congenital vascular anomalies and associated complications in newborns and infants].

PURPOSE: To assess the value of multidetector CT (MDCT) for evaluation of vascular anomalies (VA) and associated complications in newborns and infants. MATERIALS AND METHODS: Seventy-five children (mean age: 9 +/- 6 months, range: 2 weeks to 24 months) with VA were examined using MDCT (4-, 8- or 16-row; collimation 0.5-1.25 mm; scan time 7-30 s), which was performed under controlled ventilation or free breathing. Image quality was rated using a 5-point scale. Image findings were correlated to echocardiography, conventional catheter angiography (CCA), bronchoscopy, and intraoperative findings. RESULTS: High quality MDCT data were almost free of cardiac and respiratory motion. In all cases, VA morphology and topography in relation to adjacent structures, e. g. tracheal and esophageal compression caused by an aortic ring, could be assessed exactly and allowed the final diagnosis. Even aberrant vessels, such as aorto-pulmonary collaterals (MAPCA) with a diameter of less than 1 mm, could be identified and excellently visualized. Eighty percent (60/75) of all patients had benefited from the MDCT: in 31 patients CCA was neither necessary to perform surgical planning nor to exclude a VA; in an additional 29 patients radiation doses and sedation time due to interventional procedures could be reduced markedly. CONCLUSIONS: MDCT can now be regarded as the modality of choice as a minimally invasive, robust, and accurate technique for the diagnosis of complex VA, their potentially life-threatening complications and preoperative planning even in newborns and infants. Its accuracy for detecting VA appears equivalent to CCA while it is more accurate in delineating potential life-threatening complications.

Arteriovenous Malformations↗

Quantitative analysis of lung and tumour mobility: comparison of two time-resolved MRI sequences.

The purpose of this study was to describe the use of parallel imaging technique (PAT) using dynamic MRI in lung and tumour mobility during the breathing cycle. 20 patients with stage I non-small cell lung carcinoma were investigated using two dynamic gradient echo sequences with PAT (TrueFISP (fast imaging with steady precession), and fast low angle shot (FLASH). Craniocaudal distance from the apex to the diaphragm of the thorax and tumour mobility during the breathing cycle were measured. Signal-to-noise ratio (SNR) of the tumour was determined. In spite of the different temporal resolutions both trueFISP and FLASH sequence proved to be adequate to continuously measure lung motion and tumour mobility. SNR of the tumour was significantly higher using the trueFISP sequence than FLASH sequence (20.7+/-3.6 vs 5.8+/-2.3, p<0.01). Mobility of the tumour bearing hemithorax was significantly lower compared with the non-tumour bearing hemithorax (p<0.05). Dynamic MRI using PAT allows for continuous quantitative documentation of tumour mobility and lung motion. Because of the higher SNR, trueFISP sequence provides a better delineation of intrapulmonary lesions with a sufficient temporal resolution.

Aged↗

[Noninvasive measurement of relative cerebral blood flow with the blood bolus MRI arterial spin labeling: basic physics and clinical applications].

Knowledge of tumor blood flow is important for diagnosis and follow-up of brain tumors after therapy, especially to discriminate necrosis from tumor recurrence after radiation or chemotherapy. Meanwhile, perfusion and diffusion MRI, besides MR-angiography, are state of the art in stroke imaging. Until now, perfusion imaging was mostly performed using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI. The MRI-based arterial spin labeling technique (ASL) is a novel approach for measuring relative cerebral blood flow (rCBF) without using extrinsic contrast agents, by labeling spins of flowing arterial blood as intrinsic contrast agent. This article describes physical basics of ASL and shows clinical examples in neuroimaging such as in meningeoma, glioblastoma, oligodendroglioma, and cerebral ischemia, using the Q2TIPS ASL technique. Gray matter is clearly visible, while the observed white matter signal obtained by Q2TIPS is only slightly higher than background noise. Venous blood causes artefacts in the sagittal sinus and other large superficial veins in the subarachnoid space. Meningeoma and glioblastoma show elevated rCBF, whereas oligodendroglioma and cerebral ischemia have reduced rCBF values. Arterial-spin-labeling techniques are noninvasive tools for measuring rCBF within 5 min, using a standard MRI scanner.

Blood Flow Velocity↗

[MRT of bronchial carcinomas].

Compared to computed tomography (CT), magnetic resonance imaging (MRI) only plays a minor role for the imaging of lung cancer. Among the reasons are technical limitations, such as longer acquisition times or inferior spatial resolution, as well as unfavourable tissue characteristics which cause a low signal-to-noise ratio of the lung parenchyma. However, MRI is a valuable tool for staging lung cancer and may in some cases even be considered the method of choice. The following review illustrates the role of MRI for the diagnosis of lung cancer using current MR-techniques. In particular, the potential of MRI for TNM-staging, new technical developments (e. g. parallel MRI), and the application of functional MRI of the chest are described.

Carcinoma, Bronchogenic↗

[Contrast-enhanced 3D MR perfusion of the lung: application of parallel imaging technique in healthy subjects].

PURPOSE: Evaluation of lung perfusion by contrast-enhanced 3D MRI using partial parallel imaging techniques. MATERIALS AND METHODS: Eight healthy volunteers were examined using a contrast-enhanced dynamic FLASH 3D sequence with partial parallel imaging technique at 1.5 T MRI with a TA of 1.5 sec. The whole lung was covered by 36 coronal slices. A ventral, middle and dorsal slice of each lung was manually segmented and signal-to-time curves were computed. For absolute quantification of blood flow through the right and left pulmonary artery, phase-contrast flow measurements were performed. RESULTS: No significant difference was found between the signal intensity in the right (8.9 +/- 2.6) and left (8.0 +/- 3.5) lung, corresponding to a left-to-right signal intensity ratio of 0.9. A significantly higher signal intensity was found in the dorsal regions of the lungs (p = 0.01) compared to the ventral regions. The time to peak of the signal intensity was significantly shorter in the dorsal (15.3 sec) and middle (15.7 sec) regions of the lungs (p = 0.03 and p = 0.04, respectively) than in the ventral regions (16.3 sec). The ratio between blood flow through the left (2.2 L/min) and right (2.7 L/min) lung was 0.84. CONCLUSION: Partial parallel image acquisition can assess the perfusion of the lungs at high temporal resolution. The perfusion is slightly higher on the right than on the left. The signal increases faster and has a higher peak in the dorsal lung regions.

Adolescent↗

[Quantification of atelectases in artificial respiration: spiral-CT versus dynamic single-slice CT].

PURPOSE: Dynamic CT (dCT) allows visualization and quantification of ventilated lung and atelectases with high temporal resolution during continuous ventilation. This study compares a quantitative image analysis in a subcarinal single slice dCT series versus a whole lung spiral-CT, in order to analyze, whether the distribution of atelectasis of a single dCT series is representative for the whole lung. MATERIALS AND METHODS: dCT in sliding windows technique (slice thickness 1 mm, temporal increment 100 ms) was performed in 8 healthy pigs 3 cm caudal to the carina during continuous mechanical ventilation. Subsequently, a spiral-CT of the whole lung (slice thickness 2 mm; pitch 1.5; increment 2 mm) was acquired during inspiratory breath hold (airway pressure 20 mbar). Lung segmentation and planimetry of predefined density ranges were achieved using a dedicated software tool in both data-sets. Thus, the fractions of the following functional lung compartments were averaged over time: hyperinflated lung (- 1024 to - 910 HE), normal ventilated lung -900 to -300 HE) and atelectasis (-300 to +200 HE). RESULTS: Quantitative analysis of dCT-series during continuous respiration correlated with the density analysis in spiral-CT as follows: hyperinflated lung r = 0.56; normal ventilated lung r = 0.83 and atelectases r = 0.84. Analysis of spiral-CT showed the following distribution of functional lung compartments: hyperinflated lung 3.1% normal ventilated lung 77.9% and atelectasis 19.0%. In dCT, hyperinflated lung represented 6.4%, normal ventilated lung 65.2% and atelectasis 28.4% of total the lung area. CONCLUSION: The results of our study demonstrate that dCT allows monitoring of atelectasis formation in response to different ventilatory strategies. However, a deviation between dCT and spiral-CT has to be taken into account. In subcarinal dCT series, hyperinflated lung areas and atelectases were overestimated due to a craniocaudal gradient of atelectases, whereas normal ventilated lung was underestimated.

Animals↗

[A software program for quantitative analysis of alveolar oxygen partial pressure (p(A)O(2)) with oxygen-sensitive (3)He-MRI].

PURPOSE: To develop a software tool for quantitative analysis of alveolar oxygen partial pressure (p(A)O(2)) as well as its time course during apnea. MATERIAL AND METHODS: T (1)-relaxation times of hyperpolarized (3)He are reduced by paramagnetic oxygen rendering (3)He-MRI sensitive to oxygen and thus allowing the assessment of the local oxygen partial pressure in the pulmonary airspaces. Oxygen-related relaxation and loss of polarization by RF-excitation can be discriminated by acquiring two image series with varying interscan delay and/or flip angles. Software was developed to calculate the p(A)O(2) and the decay rate in user-defined regions of interest (ROIs) automatically. Moreover, parameter maps can be calculated. In addition to the analysis of 2-dimensional data sets, the software allows the evaluation of 3-dimensional measurements for the first time. Artifacts due to lung motion were reduced by implementing a motion correction algorithm. RESULTS: The software was successfully applied to data sets from healthy volunteers and from patients with various lung diseases. The parameter maps demonstrated a more homogeneous distribution of p(A)O(2) for the volunteers than for the patients. A regional increase in p(A)O(2) was found in a few patients. CONCLUSION: The described software allows the absolute quantification of p(A)O(2) as well as its variation over time. In the future, therefore, the software may gain importance for detecting mismatches between ventilation and perfusion, e. g., in patients with pulmonary embolism or chronic obstructive lung diseases.

Adult↗

[A software tool for analysis and quantification of regional pulmonary ventilation using dynamic hyperpolarised-(3)He-MRI].

PURPOSE: (3)He-MRI is able to visualize the regional distribution of lung ventilation with a temporal and spatial resolution so far unmatched by any other technique. The aim of the study was the development of a new software tool for quantification of dynamic ventilation parameters in absolute physical units. MATERIALS AND METHODS: During continuous breathing, a bolus of hyperpolarized (3)He (300 ml) was applied at inspiration and a series of 168 coronal projection images simultaneously acquired using a 2D FLASH-sequence. Postprocessing software was developed to analyze the (3)He distribution in the lung. After correction for lung motion, several ventilation parameters (rise time, delay time, (3)He amount and (3)He peak flow) were calculated. Due to normalization of signal intensities, these parameters are presented in absolute physical units. The data sets were analyzed on a ROI basis as well as on a pixel-by-pixel basis. RESULTS: Using the developed software, the measurements were analyzed in 6 lung-healthy volunteers, in one patient after lung transplantation, and in one patient with lung emphysema. The volunteers' parameter maps of the pixel-based analysis showed an almost homogeneous distribution of the ventilation parameters within the lung. In the parameter maps of both patients, regions with poor ventilation were observed. CONCLUSION: The developed software permits an objective and quantitative analysis of regional lung ventilation in absolute physical units. The clinical significance of the parameters, however, has to be determined in larger clinical studies. The software may become valuable in grading and following pulmonary function as well as in monitoring any therapy.

Aged↗

Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results.

PURPOSE: To assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. MATERIALS AND METHODS: Eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 degrees; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. RESULTS: Patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or Eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104 - 322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). CONCLUSION: Time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease.

Acute Disease↗

Pneumonia in neutropenic patients.

Radiologists have a special role in the management of neutropenic patients. The appropriate investigational technique, frequently targeted differential diagnosis, and the special needs of these patients, need to be understood. Early detection of a focus is the major goal in febrile neutropenic patients. As pneumonia is the most common focus, chest imaging is a special radiological task. The sensitivity of chest X-ray, especially in supine position, is known to be low; therefore, the very sensitive high-resolution CT (HRCT) became gold standard in neutropenic hosts and will probably be replaced by thin-section multislice CT (MSCT) in the near future. Costs of high-resolution CT are low in comparison to antibiotics. An infiltrate needs to be localised, so that a physician can utilise this information as a guidance for invasive procedures for further microbiological work-up. The radiological characterisation of infiltrates gives a first and rapid hint to differentiate between different sorts of infectious (typical bacterial, atypical bacterial, fungal) and non-infectious aetiologies. Follow-up investigations need careful interpretation according to disease and concomitant treatment. Due to an increased incidence of fungal infiltrates even with appropriate therapy, follow-up of an infiltrate must use further parameters in addition to lesion size. Temporary exclusion of infectious involvement of the lung with high accuracy remains of special interest for clinicians.

Diagnosis, Differential↗

[Hemodynamic and metabolic characterization of orthotopic rat prostate carcinomas using dynamic MRI and proton magnetic resonance spectroscopy].

AIM: The aim of this study was the noninvasive characterization of prostate carcinoma orthotopically implanted in rats using Gd-DTPA-assisted dynamic MRI (dMRI) and proton magnetic resonance spectroscopy ((1)H-MRS). MATERIAL AND METHODS: After surgical exposure of the prostate, Dunning R3327 orthotopic prostate carcinoma was induced by injecting cells of the MAT-LyLu subline. Six rats were examined 5 and 14 days after tumor induction with dMRI and (1)H-MRS at 1.5 T. Six tumor-free rats served as controls. Using an open two-compartment model, the parameters A (amplitude) and k(ep) (exchange rate constants) were calculated from the signal time curves of the dMRI. The relative signal intensities (Cho/Cr) of the resonances of choline (Cho) and the creatine-phosphocreatine complex (Cr) were computed from the MR spectra. RESULTS: Already after 5 days, the tumors in the prostate could be clearly identified based on the decrease in signal intensity to T2w and increase of A and k(ep). High Cho/Cr levels and resonances of two lipid fractions (Lip(1) at 0.8-1.5 ppm and Lip(2) at 2.0-2.2 ppm) were observed by MRS in the highly necrotic tumors. CONCLUSIONS: The orthotopic rat prostate carcinoma model resembles human prostate carcinoma in regard to MR morphology, dMRI, and (1)H-MRS. The noninvasive characterization of perfusion and metabolism makes a comparative examination of different treatment modalities possible.

Algorithms↗

[Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model].

AIM: The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. METHODS: The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k(ep)). The microvascular density of resected prostate carcinomas was determined. RESULTS: The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k(ep). Prostate carcinomas of the peripheral zone were demarcated by amplitude and k(ep). In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k(ep) and in the FLASH sequence in terms of amplitude. CONCLUSION: Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k(ep) reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors.

Biopsy↗

[Quantification of tissue perfusion with novel ultrasound methods].

Perfusion describes an important parameter of tissue vitality, e. g. of the myocardium, brain, or the kidney. In malign tumours, perfusion is of particular interest for characterization and prognosis. In addition, new pro- or anti-angiogenic therapies require a functional imaging which is suitable to quantify vascularity. Sonographic methods for the detection of microvascularity, particularly related smaller than those amenable to Doppler ultrasound, are reviewed. The main focus deals with the explanation of contrast-enhanced sonography using replenishment kinetics of microbubbles which provides a comprehensive quantification of tissue perfusion. Alterations of the microvascularity e. g., under anti-angiogenic therapy, can be depicted in experimental studies using this novel approach. Further clinical applications can be the quantification of the perfusion in the myocardium, the brain, or the kidney. New approaches to optimize the theoretical model to describe the replenishment, and novel technical developments are discussed.

Animals↗

[Reformation as proposed solution for the problem of sectioning different levels with 3He-MRT and HR-CT of the chest].

PURPOSE: 3He-MRI of the lung has been shown to be a sensitive method for functional imaging of the lung. A previous study compared 3He-MRI (coronal planes) with CT (transverse planes) by looking for ventilation defects and their pathomorphologic correlation. Anatomic structures, such as lobar fissures and hilar vessels, were used for orientation, but the reliable assignment of ventilation defects to lung segments is problematic. The present work compares multiplanar reformations of 3He-MRI and HR-CT, which were generated from planes determined by the respective method, and investigates their suitability as a solution of this problem. MATERIALS AND METHODS: A total of 16 data sets taken from 15 patients with unilateral lung transplantation and one patient with lung emphysema were retrospectively evaluated. Transverse planes of 3He-MRI and coronal planes of HR-CT were reformatted on an external workstation and images evaluated by two readers in consensus. The evaluation searched for ventilation defects on 3He-MRI and their corresponding defects on HR-CT. The defects were related to anatomic structures, with hilar vessels and tracheobronchial tree selected for 3He-MRI reformations and lobar fissures for HR-CT reformations. RESULTS: All cases were successfully reformatted and all ventilation defects were correctly assigned to anatomic structures. On HR-CT reformations, the lobar fissures were partially visible in 12 of 16 cases and completely visible in the remaining 4 cases. Since reformation compromises the spatial resolution, the reformatted images should be evaluated together with the source images. CONCLUSION: Looking at HR-CT and 3He-MRI images and their reformations enables the detection of ventilation defects and their assignment to lung segments, facilitating the correlation of ventilation defects with a pathomorphologic pattern on HR-CT.

Adult↗

[Pre- and postoperative assessment of hemodynamics in patients with chronic thromboembolic pulmonary hypertension by MR techniques].

PURPOSE: To evaluate the potential of MRI to grade cardiac impairment and pulmonary hypertension in patients with chronic thromboembolic pulmonary hypertension (CTEPH) in comparison with invasive pressure measurements before and after surgery. MATERIALS AND METHODS: We examined 35 patients with CTEPH before and after pulmonary thromboendarterectomy (PTE). For assessment of hemodynamics, velocity-encoded segmented GE-sequences (pulmonary arteries and ascending aorta) and segmented cine GE-sequences along the short axis of the heart were performed. The analysis comprised calculation of ejection fractions, peak velocities, mean pulmonary arterial flow and vessel diameter. 10 volunteers served as controls. Flow measurements were compared to invasively measured mean pulmonary arterial pressure (MPAP) and vascular resistance (PVR). RESULTS: Compared to volunteers, CTEPH-patients showed significantly reduced right ventricular ejection fractions (p < 0.001), pulmonary peak velocity (p < 0.001) and significantly increased diameters of the pulmonary arteries (p < 0.001). The flow measurements in the aorta (2713 ml/min) and the pulmonary arteries (2088 ml/min) revealed a large bronchopulmonary shunt. After PTE, there was a significant reduction in vessel diameter (p < 0.001). This was associated with a significant increase in pulmonary peak velocities (p < 0.001). The increase in pulmonary peak velocities correlated with the decrease of PVR (r = 0.5) and MPAP (r = 0.6). The ejection fraction of the right ventricle correlated with PVR (r = 0.6) and MPAP (r = 0.7). The postoperative decrease in MPAP correlated with the increase in right ventricular ejection fraction (r = 0.8). After PTE there was no bronchopulmonary shunt volume. All patients had an inverse motion of the interventricular septum. It returned to normal in 68 % of patients after surgery. CONCLUSION: Breath-hold MR-techniques enable non-invasive assessment of pulmonary hemodynamics in patients with CTEPH. For postoperative follow-up studies MRI could be considered the modality of choice.

Adult↗

Lung density distribution in dynamic CT correlates with oxygenation in ventilated pigs with lavage ARDS.

BACKGROUND: Fast dynamic computed tomography (dCT) has been used to assess regional dynamics of lung inflation and deflation processes. The aim of this study was to relate ventilation-induced changes in lung density distribution, as measured over several respiratory cycles by dCT, to oxygenation and shunt fraction in a lavage acute respiratory distress syndrome model. METHODS: Six anaesthetized pigs underwent pressure-constant ventilation (FIO2=1.0, inspiratory:expiratory ratio=1:1) before and after induction of lung damage by saline lavage. Mean airway pressure (Paw) was varied (8, 13, 18, 23, 28, 33, and 38 cm H2O) in random order. At each Paw level, dCT acquisitions were performed over several respiratory cycles (Somatom Plus4, Siemens; supradiaphragmatic transverse slice; thickness=1 mm; temporal resolution=100 ms). During scanning at each Paw, arterial and mixed venous blood were obtained for blood gas analysis and shunt calculation. In each CT image, fractional areas (FA) of defined density ranges representing ventilated lung and atelectasis were determined by planimetry using dedicated software. The FA data of individual 100 ms scans were averaged over several respiratory cycles, and expressed as mean FA in percentage of total lung area at each Paw. For atelectatic lung parenchyma a quantitative relationship of the respective mean FA to shunt fraction was studied using regression analysis. RESULTS: Under steady-state conditions, mean FA of atelectasis correlated linearly with the calculated shunt fraction (healthy lungs, r=+0.76; lavaged lungs, r=+0.89). There is a non-linear relationship between mean FA of ventilated lung parenchyma and mean FA of atelectasis with PaO2. CONCLUSIONS: We conclude that dCT allows assessment of the effects of ventilator adjustments and resultant Paw; changes upon lung aeration and oxygenation rapidly, and with good spatial and temporal resolution. This may benefit patients with acute lung injury, whose ventilatory pattern may be optimized as early as during their first diagnostic workup.

Animals↗