PubMed Health⌕ Search

Biomedical subjects

Hai-Dong Liang

Publications and source records attributed to Hai-Dong Liang.

6 recordsLinked to original sources

Pluronic block copolymers: novel functions in ultrasound-mediated gene transfer and against cell damage.

Pluronics have been investigated as vectors for drug and gene delivery in vitro and in vivo and were demonstrated to have high efficiency for gene transfer in vivo. However, they alone do not enhance gene transfer in vitro. We examined three pluronics, F127, L61 and P85, for their effects on ultrasound (US)-mediated gene transfer in three cell lines, 3T3-MDEI, C2C12 and CHO. The polymers showed differential effects on cell viability and transfection efficiency in a dose-dependent manner. All the polymers were unable to facilitate gene transfer when used alone, but enhanced US-mediated gene transfer significantly at concentrations around the critical micelle concentration in the three cell lines. F127 showed no significant toxicity at any concentration and protected the cells against US-mediated damage at a high concentration. L61 decreased cell viability significantly in a dose-dependent manner, whereas P85 showed mild toxicity when its concentration was at or above 0.05%.

3T3 Cells↗

Comparing transfection efficiency and safety for antisense oligodeoxyribonucleotide between phospholipids-based microbubbles and liposomes.

OBJECTIVE: To compare transfection efficiency and safety for antisense oligodeoxynucleotides (AS-ODNs) between two type of phospholipids-based vectors. METHODS: An AS-ODNs sequence HA824 combined with luciferase reporter plasmid was used. Under low intensity ultrasound (US), a breast cancer cell line SK-BR-3 was exposed to different concentration of microbubbles and liposomes. Transfection efficiency was detected by fluorescence microscopy. Cell viability was verified by propidium iodide assay. Reverse transcription-polymerase chain reaction (RT-PCR) was used to detect the inhibitory effect of HA824 on HER-2 expression at mRNA level. Atomic force microscopy (AFM) scanning techniques was employed to observe the change of membrane pore size. RESULTS: AS-ODNs transfection efficiency showed an increasing tend with microbubble concentration, but not with liposome concentration. Maximum transfection efficiency with minimum cell viability was achieved under 2% microbubble concentration. Too strong sonoporation activity would enlarge membrane pores significantly and cause low cell viability. CONCLUSION: US-mediated AS-ODNs transfection enhanced by phospholipids-based microbubbles represents an effective and safe avenue.

Cell Line, Tumor↗

Gene transfer with microbubble ultrasound and plasmid DNA into skeletal muscle of mice: comparison between commercially available microbubble contrast agents.

PURPOSE: To compare three commercial microbubble contrast agents (Optison, SonoVue, and Levovist) for their effect on gene delivery in skeletal muscle in conjunction with the use of therapeutic ultrasound. MATERIALS AND METHODS: The study was approved by the Animal Care and Use Committee. Plasmid DNA (10 microg) encoding green fluorescent protein (GFP) was mixed with microbubbles (or saline control) and injected into the tibialis anterior muscle of mice with and without adjunct ultrasound (1 MHz, 2 W/cm2, 30 seconds, 20% duty cycle). The efficiencies of GFP transgene expression were determined with four experimental conditions: (a) plasmid and saline as control (six mice), (b) plasmid and Optison (six mice), (c) plasmid and SonoVue (four mice), and (d) plasmid and Levovist (air based, four mice). The right legs were exposed to ultrasound, while the left legs were unexposed. Transfection efficiency was assessed by counting the number of GFP-positive fibers. Tissue damage was assessed by measuring the maximal-damage area on serial sections. RESULTS: When ultrasound was applied, both SonoVue and Optison significantly improved (P < .05) gene transfection efficiency. Optison was also effective (P < .05) even when no ultrasound was applied, which is consistent with previous studies. Levovist without ultrasound decreased the level of transfection (P < .05), with increased tissue damage. CONCLUSION: Both non-air-based agents show promise in gene delivery in skeletal muscle with undetectable tissue damage. Enhanced gene transfer with additional ultrasound was achieved only with SonoVue.

Albumins↗

Preparation, characterization and in vivo observation of phospholipid-based gas-filled microbubbles containing hirudin.

The objective of this work was to prepare echogenic phospholipid-based gas-filled microbubbles (PGM) and investigate their physical characteristics, echogenicity and loading ability of hirudin under various NaCl concentrations. PGM were prepared by a sonication-lyophilization method. Hirudin was used as a model drug to evaluate the drug encapsulation efficiency of the PGM. PGM loaded with hirudin were prepared by dissolving lyophilized powder with hirudin solution. The morphology, particle size and microbubble concentration of PGM were measured. The hirudin encapsulation efficiency as a function of NaCl concentration was determined. The mean particle size and microbubble concentration of PGM were unchanged by the presence of hirudin for at least 60 min after preparation. Hirudin encapsulation quantity was proportional to the hirudin concentration until saturation occurred at high concentration, and the encapsulation efficiency had an inverse relationship. Hirudin encapsulation efficiency was affected by NaCl concentration. When NaCl concentration was increased from 10 mg mL(-1) to 20 mg mL(-1) in PGM solution, hirudin encapsulation efficiency decreased from 35.8 to 26.7%, and microbubble concentration decreased from 2.7 x 10(8) to 1.7 x 10(8) microbubbles per mL. The PGM were shown easily to be visible in in vivo rabbit liver. There was no difference in echogenicity between the loaded and unloaded bubbles. PGM prepared by the sonication-lyophilization method exhibited satisfactory physical characteristics and loading ability and are suitable for use in imaging and ultrasound-triggered delivery.

Animals↗

Optimisation of ultrasound-mediated gene transfer (sonoporation) in skeletal muscle cells.

Ultrasound (US) is a promising tool for facilitating direct gene transfer to skeletal muscle, but no systematic optimisation study has been performed. We exposed H2K myoblast cells to US with varying intensity of exposure and duration to evaluate its effect on cell viability and transfection efficiency using as endpoints transfection rate, average fluorescence intensity (fluorescence normalised by the number of transfected cells) and overall expression (the product of transfection rate and average fluorescence intensity) as indices. Cell viability decreased with exposure time and intensity, consistent with previous findings. Optimal setting of US was observed at the range of 0.5 to 1 W cm(-2) with duration of 20 s, producing maximum efficiency (transfection = 4.5%) in gene transfection with minimum cell toxicity (cell viability = 83%). Higher intensity alone or in combination with low intensity and long duration did not improve cell viability and transfection. The increase of eGFP (enhanced green fluorescence protein) plasmid concentration up to 200 microg per mL was related to an increase in average fluorescence intensity and overall expression. However, transfection rate saturated when DNA concentration reached 50 microg per mL despite initial increase with DNA concentration. The average fluorescence intensity was linearly proportional to the logarithm of DNA concentration, suggesting a diffusion-based model for DNA uptake under sonoporation. We conclude that low-intensity US irradiation provides a safe and effective alternative for gene delivery.

Animals↗

Incoherent imaging using continuous wave ultrasound. A preliminary study using bovine intervertebral discs.

As an object rotates with respect to a stationary planar ultrasonic beam, the scattering centres within the object return echoes that are Doppler-shifted in frequency by amounts depending on the velocities of the individual scatterers. The backscattered echo amplitude at any particular frequency is the line integral of the scattered radiation at the cross-range corresponding to that frequency. The amplitude as a function of frequency can be interpreted as a tomographic projection. A tomographic reconstruction algorithm can produce an image of the distribution of scattering centres in the insonified object from these projections. This paper describes the development and characterisation of a microscanner to investigate the approach of using continuous wave ultrasound for three-dimensional cross-sectional imaging. The results of preliminary tissue investigation, conducted using bovine coccygeal intervertebral discs, are described. The radial imaging resolution improves as the Doppler frequency resolution improves but the circumferential resolution degrades proportionally. As the number of projections increases, there is a finite increase in image quality. Two- and three-dimensional images of the intervertebral disc reveal an alternate light and dark banding pattern that is characteristic of the laminar structure of the annulus fibrosus.

Algorithms↗