Improvement of elastographic displacement estimation using a two-step cross-correlation method.

The cross-correlation algorithm used to compute the local strain components for elastographic imaging requires a minimum radio-frequency data segment length of around 10 wavelengths to obtain accurate and precise strain estimates with a reasonable signal-to-noise ratio. Shorter radio-frequency data segments generally introduce increased estimation errors as the information content in the data segment reduces. However, shorter data segments and increased overlaps are essential to improve the axial resolution in the strain image. In this paper, we propose a two-step cross-correlation technique that enables the use of window lengths on the order of a single wavelength to provide displacement and strain estimates with similar noise properties as those obtained with a 10 wavelength window. The first processing step utilizes a window length on the order of 10 wavelengths to obtain coarse displacement estimates between the pre- and post-compression radio frequency data frames. This coarse displacement is then interpolated and utilized as the initial guess-estimate for the second cross-correlation processing step using the smaller window. This step utilizes a single wavelength window to improve the axial resolution in strain estimation, without significantly compromising the noise properties of the image. Simulation and experimental results show that the signal-to-noise and contrast-to-noise ratio estimates improve significantly at the smaller window lengths with the two-step processing when compared with the use of a similar sized window in the currently utilized single window method.

Elasticity↗

Two-dimensional multi-level strain estimation for discontinuous tissue.

A large number of the strain estimation methods presented in the literature are based on the assumption of tissue continuity that establishes a continuous displacement field. However, in certain locations in the body such as the arteries in vivo scanning may produce displacement fields that are discontinuous between the two walls of the artery. Many of the displacement or strain estimators fail when the displacement fields are discontinuous. In this paper, we present a new 2D multi-level motion or displacement tracking method for accurate estimation of the strain in these situations. The final high-resolution displacement estimate is obtained using two processing steps. The first step involves an estimation of a coarse displacement estimate utilizing B-mode or envelope signals. To reduce computational time, the coarse displacement estimates are obtained starting from down-sampled B-mode pre- and post-compression image pairs using a pyramidal processing approach. The coarse displacement estimate obtained from the B-mode data is used to guide the final 2D cross-correlation computations on radio-frequency (RF) data. Results from finite element simulations and in vivo experimental data demonstrate the feasibility of this approach for imaging tissue with discontinuous displacement fields.

Algorithms↗

Stability of heterogeneous elastography phantoms made from oil dispersions in aqueous gels.

A set of five tissue-mimicking phantoms with cylindrical inclusions were produced for assessing long-term stability of geometry and elastic properties and assessing accuracy of determination of elastic properties. The base aqueous materials were either gelatin or a mixture of agar and gelatin. Stiffness was controlled by selection of the volume percent consisting of microscopic safflower oil droplets. Cylinder diameters remained unchanged within 1% or 2% over many months. Strain ratios from elastograms of the phantoms were stable over many months, implying that elastic contrasts were also stable. Test samples, called production samples, for measurement of Young's moduli were made at the time of manufacture of each phantom and were stored separately from one another. Each production sample was homogeneous and consisted of either inclusion material or background material. For all five phantoms, it was found that the elastic contrast computed using Young's modulus values determined using the production samples accurately represented the true elastic contrasts in the corresponding phantom. This finding was established by the fact that the (true) elastic contrasts determined using samples excised from the phantoms themselves agreed with the elastic contrasts obtained using the homogeneous production samples.

Agar↗

Anthropomorphic breast phantoms for testing elastography systems.

Two equivalent anthropomorphic breast phantoms were constructed, one for use in ultrasound elastography and the other in magnetic resonance (MR) elastography. A complete description of the manufacturing methods is provided. The materials used were oil-in-gelatin dispersions, where the volume percent oil differentiates the materials, primarily according to Young's moduli. Values of Young's moduli are in agreement with in vitro ranges for the corresponding normal and abnormal breast tissues. Ultrasound and nuclear magnetic resonance (NMR) properties are reasonably well represented. Phantoms of the type described promise to aid researchers who are developing hardware and software for elastography. Examples of ultrasound and MR elastograms of the phantoms are included to demonstrate the utility of the phantoms. Also, the level of stability of elastic properties of the component materials is quantified over a 15-month period. Such phantoms can serve as performance-assessing intermediaries between simple phantoms (consisting, for example, of homogeneous cylindrical inclusions in a homogeneous background) and a full-scale clinical trial. Thus, premature clinical trials may be avoided.

Anthropometry↗

Spatial-angular compounding for elastography using beam steering on linear array transducers.

Spatial-angular compounding is a new technique that enables the reduction of noise artifacts in ultrasound elastography. Under this method, compounded elastograms are obtained from a spatially weighted average of local strain estimated from radio frequency (rf) echo signals acquired at different insonification angles. In previous work, the acquisition of the rf signals was performed through the lateral translation of a phased-array transducer. Clinical applications of angular compounding would, however, require the utilization of beam steering on linear-array transducers to obtain angular data sets, which is more efficient than translating phased-array transducers. In this article, we investigate the performance of angular compounding for elastography by using beam steering on a linear-array transducer. Quantitative experimental results demonstrate that spatial angular compounding provides significant improvement in both the elastographic signal-to-noise ratio and the contrast-to-noise ratio. For the linear array transducer used in this study, the optimum angular increment is around 1.5 degrees-3.75 degrees, and the maximum angle that can be used in angular compounding should not exceed 10 degrees.

Artifacts↗

Spherical lesion phantoms for testing the performance of elastography systems.

A set of three cubic one-litre phantoms containing spherical simulated lesions was produced for use in comparing lesion detection performance of different elastography systems. The materials employed are known to be stable in heterogeneous configurations regarding geometry and elastic contrast identical with (storage modulus of lesion material) / (storage modulus of background material), and regarding ultrasound and NMR properties. The materials mimic soft tissues in terms of elastic, ultrasound and NMR properties. Each phantom has only one value of elastic contrast (3.3, 4.6 or 5.5) and contains arrays of 1.6 mm, 2 mm, 3 mm and 4 mm diameter spherical simulated lesions. All the spheres of a given diameter are arranged in a regular array with coplanar centres. Elastograms of an array made with ultrasound allow determination of the depth range over which lesions of that diameter and elastic contrast can be detected. Two phantoms are made from agar-plus-gelatin-based materials, and one is made from oil-in-gelatin dispersions. The methods for producing the phantoms are described in detail. Lesion detection performances for two ultrasound systems, both operating at about 7.5 MHz and focused at about 5 cm, were quantified with distinctions between the two systems demonstrated. Neither system was capable of detecting any of the 1.6 mm lesions. Phantoms such as these should be useful in research labs that are refining hardware and/or software for elastography.

Agar↗

Tissue-mimicking agar/gelatin materials for use in heterogeneous elastography phantoms.

Five 9 cm x 9 cm x 9 cm phantoms, each with a 2-cm-diameter cylindrical inclusion, were produced with various dry-weight concentrations of agar and gelatin. Elastic contrasts ranged from 1.5 to 4.6, and values of the storage modulus (real part of the complex Young's modulus) were all in the soft tissue range. Additives assured immunity from bacterial invasion and can produce tissue-mimicking ultrasound and NMR properties. Monitoring of strain ratios over a 7 to 10 month period indicated that the mechanical properties of the phantoms were stable, allowing about 1 month for the phantom to reach chemical equilibrium. The only dependable method for determining the storage moduli of the inclusions is to make measurements on samples excised from the phantoms. If it is desired to produce and accurately characterize a phantom with small inclusions with other shapes, such as an array of small spheres, an auxiliary phantom with the geometry of the cylindrical inclusion phantoms or the equivalent should be made at the same time using the same materials. The elastic contrast can then be determined using samples excised from the auxiliary phantom. A small increase of about 10% in volume of the cylindrical inclusions occurred-a tolerable increase. Interestingly, the smallest increase (about 5%) occurred in the phantom with the largest elastic contrast.

Adhesives↗

A general solution for catheter position effects for strain estimation in intravascular elastography.

Intravascular ultrasound (US) elastography reveals the elastic properties of vascular tissue and plaque. However, misalignment of the US catheter in the vessel lumen can cause incorrect strain estimation in intravascular US elastography caused by strain projection artifacts. In this paper, we present a general theoretical solution where the impact of catheter eccentricity, tilt and noncoplanar errors on the strain estimates are derived. Appropriate corrections to strain estimates can then be applied with prior knowledge of the catheter position information to reduce the strain projection artifacts. Simulations using a frequency-domain-based algorithm that models intravascular US imaging before and after a specified deformation are presented. The simulations are used to verify the theoretical derivations for two displacement situations (linear and nonlinear) under intraluminal pressure, with and without stress decay. The linear displacement case demonstrates that the correction factor is dependent only on the angle between the US beam and the cross-sectional plane of the vessel. For the nonlinear displacement case, where a l/r stress decay in the displacement is modeled, the correction factor becomes a more complicated function of the azimuthal angle.

Artifacts↗

Elastographic imaging of thermal lesions in liver in-vivo using diaphragmatic stimuli.

Radiofrequency or microwave ablations are interstitial focal ablative therapies that can be used in a percutaneous fashion for treating tumors in the liver, kidney, and prostate. These modalities provide in situ destruction of tumors. We present a method for in-vivo elastographic visualization of the ablated regions in the liver during and after thermal therapy. In-vivo elastographic imaging uses compressions of the liver due to movement of the diaphragm during the respiratory cycle. Elastography of the liver and other abdominal organs has not been attempted previously due to the difficulty in providing controlled compressions. Gating of the data acquisition to the respiratory waveform would provide access to data where the compression increments are similar in both magnitude and direction, thereby enabling reproducible imaging of the thermal lesion or tumor. Comparison of elastograms with gross-pathology of ablated tissue illustrates the correspondence between elastographic image features and pathology. Ultrasound is routinely used to guide the rf ablation procedure, so the same imaging system could be used for elastographic imaging. Since the technique utilizes physiological motion of the diaphragm due to respiration, it may also be employed in the visualization of cancerous tumors in the liver.

Animals↗