PubMed Health⌕ Search

Biomedical subjects

Hanfa Zou

Publications and source records attributed to Hanfa Zou.

At least 19 recordsLinked to original sources

Preparation and evaluation of a molecularly imprinted polymer derivatized silica monolithic column for capillary electrochromatography and capillary liquid chromatography.

A method for preparation of molecularly imprinted polymer (MIP) derivatized onto the surface of a monolithic silica capillary column was successfully developed. The vinyl groups were first introduced onto the silica monolith by immobilization of gamma-methacryloxypropyltrimethoxysilane. Then the MIP coating was copolymerized and anchored onto the surface of the silica monolith. Acetonitrile was selected as porogen (solvent). The other preparation conditions, such as monomer concentration, temperature, and time of polymerization, were systematically studied. The obtained MIP-derivatized silica monolith using l-tetrahydropalmatine (l-THP) and (5S,11S)-(-)-Tröger's base (S-TB) as the imprinted template, respectively, was characterized in terms of the retention behavior of thiourea and toluene. Under the optimized CEC conditions, baseline enantioseparations of THP and TB were achieved in 4 min though the effective length of the columns was 8.5 cm. The result indicates that enough recognition sites were on the surface of silica monolith, resulting in strong recognition ability. Compared with a MIP organic monolith, the MIP-derivatized silica monolith exhibits better column efficiency and stability in CEC. Additionally, the comparison of these two kinds of monolithic columns was performed by capillary liquid chromatography. The separation on MIP-derivatized silica monolith was superior to that on the organic monolith.

Journal Article↗

Recent progress in polar stationary phases for CEC.

This review summarizes most of the recent developments in the preparation and application of polar stationary phases for CEC covering the literature published since the year 2004. These polar stationary phases have been adopted for separation of analytes by the modes of packing column CEC, open-tubular CEC (o-CEC) and monolithic column CEC. Currently, development of o-CEC using biomolecules, such as protein and DNA, as the immobilized ligands is highlighted partly due to the simplicity of preparation. Furthermore, monolithic columns have been extended quickly, particularly inorganic materials-based monoliths, such as silica, zirconia, hafnium, etc., as an alternative to packed columns have been developed quickly.

Capillary Electrochromatography↗

Fe3+ immobilized metal affinity chromatography with silica monolithic capillary column for phosphoproteome analysis.

Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+-IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of alpha-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (muRPLC-nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12 mug mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with muRPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample.

Animals↗

Recent developments in methods and technology for analysis of biological samples by MALDI-TOF-MS.

Matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF-MS) is widely used in a variety of fields because it has the characteristics of speed, ease of use, high sensitivity, and wide detectable mass range for obtaining molecular weights and for structural characterization of macromolecules. In this article we summarize recent developments in matrix additives, new matrices, and sample-pretreatment methods using off-probe or on-probe techniques or nanomaterials for MALDI-TOF-MS analysis of biological samples.

Analytic Sample Preparation Methods↗

Biological fingerprinting analysis of the interactome of a kinase inhibitor in human plasma by a chemiproteomic approach.

In this study, a gel free chemiproteomic method based on chromatography was developed and applied for the biological fingerprinting analysis of complex biological system. p-Aminobenzamidine (ABA), an inhibitor of trypsin-like serine proteases, was immobilized for characterizing their interacting proteins in human plasma. By the proteomic analysis method, 214 proteins were identified with obvious affinity to the immobilized ABA. By searching the sequences of above proteins with consensus patterns of the two active sites, seven proteins belong to trypsin-like serine protease group were found. Based on the Gene Ontology annotation, the identified trypsin-like serine proteases have the function of catalytic activity and calcium ion binding, and are mainly involved in the biological process of blood coagulation. Eight more other proteins related to calcium ion binding and blood coagulation were found. Nearly all of these proteins cannot be identified by directly analyzing the plasma sample demonstrating the chemiproteomics a useful approach to characterize interacting proteins in the low abundance range.

Adult↗

Characterization of enantioselective binding of racemic natural tetrahydropalmatine to DNA by chromatographic methods.

A racemate from natural product, tetrahydropalmatine (THP), was characterized on its enantioselective binding to DNA by the chromatographic methods including microdialysis/HPLC, centrifugal ultrifiltration/HPLC and immobilized DNA affinity chromatography. It was found that its (+)-enantiomer was preferential to binding on B-form duplex DNA including calf thymus DNA, AT and GC sequence oligo DNA, as well as triplex oligo DNA. The binding constants of the THP enantiomers to ct-DNA were determined with the methods of microdialysis/HPLC and frontal affinity chromatography. In addition, the DNA structural preference of either enantiomer was evaluated with the chromatographic methods.

Berberine Alkaloids↗

Monitoring enzyme reaction and screening enzyme inhibitor based on MALDI-TOF-MS platform with a matrix of oxidized carbon nanotubes.

A matrix assisted laser desorption/ionization time-of-flight mass spectrometry platform for quantitatively monitoring enzyme activity and screening enzyme inhibitors has been demonstrated. The described method employs a new matrix of oxidized carbon nanotubes. Compared with the traditional fluorescence approach, this label-free method has the advantage of directly identifying the substrates and products in enzymatic reactions. Moreover, the method could be conveniently carried out with any commercial mass spectrometer without modification. We quantitatively monitored the acetylcholinesterase activity and screened acetylcholinesterase inhibitors with a detection rate of about 3.3 s per sample.

Acetylcholinesterase↗

Enantioseparation of tetrahydropalmatine and Tröger's base by molecularly imprinted monolith in capillary electrochromatography.

Two chiral compounds, Tröger's base and tetrahydropalmatine, were enantioseparated on the (5S, 11S)-(-)-Tröger's base and l-tetrahydropalmatine imprinted monolithic capillary columns with CEC, respectively. The monoliths were prepared by in situ thermal-initiated copolymerization of methacrylic acid (MAA) and ethylene dimethacrylate (EDMA). After optimizing the ratio of porogens (toluene and dodecanol), the obtained monolithic capillary columns show good flow-through property and enantioselectivity. The influences of CEC parameters such as pH of the buffer, organic solvent and salt concentration on the electroosmotic flow (EOF) and recognition selectivity were systematically investigated. Under the optimal conditions, baseline resolutions of two chiral compounds were achieved. In addition, the fast separation was obtained within 4 min by applying higher voltage and assisting pressure of 6 bar.

Acetonitriles↗

A matrix of 3,4-diaminobenzophenone for the analysis of oligonucleotides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

A new matrix of 3,4-diaminobenzophenone (DABP) was demonstrated to be advantageous in the analysis of oligonucleotides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. With DABP as a matrix, intact oligonucleotide ions can be readily produced with lower laser powers, resulting in better detection limits, less fragmentation and fewer alkali metal ion adducts compared with the results obtained with conventional matrices. Importantly, minimal fragmentation and fewer alkali metal ion adducts were seen even at low concentrations of oligonucleotides. It was also found that samples prepared with DABP are highly homogenous and therefore reducing the need for finding 'sweet' spots in MALDI. In addition, excellent shot-to-shot reproducibility, resolution and signal-to-noise ratio were seen with DABP as the matrix.

Benzophenones↗

Analysis of oxidized multi-walled carbon nanotubes in single K562 cells by capillary electrophoresis with laser-induced fluorescence.

Short oxidized multi-walled carbon nanotubes (CNT) were derivatized with fluorescein isothiocyanate (FITC). Capillary electrophoresis coupled with laser-induced fluorescence (CE-LIF) was then used to separate and detect the fluorescently labeled carbon-nanotube probes (CNTP) in multidrug-resistant cells (K562A) and the parent cells (K562S). Greater expression of P-glycoprotein in K562A cells than in K562S cells was confirmed by use of anti-P-glycoprotein antibody and flow-cytometric analysis. Analyses of CNTP in both cell lines using both CE-LIF and flow cytometry showed that CNTP could traverse the cellular membrane without being pumped out by P-glycoprotein. The CNTP distributed in both cell lines was analyzed at the single cell level and the results were compared with those from analysis of ten cells and of the lysate from bulk cells. The results revealed the CE-LIF method could be used for quantitative analysis of CNT in single cells in studies of drug delivery and multidrug resistance.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Screening and analysis of an antineoplastic compound in Rhizoma Chuanxiong by means of in vitro metabolism and HPLC-MS.

A new screening and analysis method that combines in vitro metabolism with high-performance liquid chromatography-mass spectrometry (HPLC-MS) was developed for the screening and analysis of an antineoplastic compound, coniferyl ferulate, which is present in the rhizome of Rhizoma Chuanxiong. Infrared (IR), ultraviolet visible spectroscopy (UV-Vis), nuclear magnetic resonance (NMR) and element analysis were used to identify the molecular structure of coniferyl ferulate. The quantitative analysis of coniferyl ferulate in different extracts of Rhizoma Chuanxiong was carried out, and the metabolism of coniferyl ferulate was investigated by in vitro incubation with rat liver homogenate. The metabolite of coniferyl ferulate, ferulic acid ethyl ester, was identified by HPLC-MS, UV-Vis and IR. In addition, antineoplastic activities of coniferyl ferulate and ferulic acid ethyl ester were detected by the MTT assay. The observed inhibition rate of coniferyl ferulate on the activity of HeLa cells was over 80% at 5.4 ng microl(-1). However, its metabolite, ferulic acid ethyl ester, showed no antineoplastic activity in vitro.

Antineoplastic Agents, Phytogenic↗

Determination of DL-tetrahydropalmatine in Corydalis yanhusuo by L-tetrahydropalmatine imprinted monolithic column coupling with reversed-phase high performance liquid chromatography.

A method for direct determination of DL-tetrahydropalmatine (DL-THP) in Corydalis yanhusuo, a traditional Chinese herb, by L-THP imprinted monolithic precolumn on-line/off-line coupling with reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The L-THP imprinted monolithic column has been prepared by in situ polymerization using methacrylic acid (MAA) and ethylene dimethacrylate (EDMA) as functional monomer and cross-linker, respectively. With the optimization of chromatographic conditions, such as mobile phase composition, flow rate, column temperature and sample loading, for the separation of enantiomer, DL-THP was base-line separated on the MIP. The imprinted monolithic column was used as a precolumn for fractionation of the C. yanhusuo extract. Both the non-retained and retained fractions were separated by RP-HPLC. Meanwhile, the D-THP and L-THP can be detected in the non-retained and retained fractions, respectively. Additionally, direct determination of L-THP using molecularly imprinted monolith on-line coupling with a reversed-phase column was acquired.

Berberine Alkaloids↗

Matrix with high salt tolerance for the analysis of peptide and protein samples by desorption/ionization time-of-flight mass spectrometry.

High concentrations of urea and guanidine hydrochloride are commonly used for the denaturation of protein, which was digested by enzymatic proteolysis for the identification by MS analysis. The presence of these contaminants seriously suppresses the ion signal of analytes in MALDI-TOF MS analysis. Herein, a novel MALDI matrix, 3, 4-diaminobenzophenone (DABP), has been found with high tolerance for these contaminants in MALDI MS analysis. The ion signal of analyte insulin can be detected in the presence of 2 M guanidine hydrochloride and 1.5 M urea using DABP as matrix. The tryptic digest of BSA (400 fmol) in 1 M guanidine hydrochloride or 1 M urea was successfully analyzed without any pretreatment prior to MS analysis. Furthermore, it has been found that this matrix can also effectively suppress the cation ion adduction of the peptides in the presence of high concentrations of metal ions in sample solution.

Benzophenones↗

Ultrafast enzyme immobilization over large-pore nanoscale mesoporous silica particles.

By finely tuning the TEOS/P123 molar ratio of the octane/water/P123/TEOS quadruple emulsion system and by controlling the synthesis conditions, an ultrafine emulsion system was isolated, under the confinement of which, nanoscale silica particles with ordered large mesopores (approximately 13 nm) have been successfully constructed; the obtained mesoporous silica particles have an unusual ultrafast enzyme adsorption speed and the amount of enzyme that can be immobilized is larger than that of conventional mesoporous silica, which has potential applications in the fast separation of biomolecules.

Adsorption↗

CE-LIF coupled with flow cytometry for high-throughput quantitation of fluorophores in single intact cells.

We report a method of coupled CE-LIF detection with flow cytometry for high-throughput determination and quantitation of fluorophores in single intact K562/S (KS) cells. The membrane properties of KS cell including fluophore transport rate and apparent permeability coefficient were further quantitatively characterized. The method has advantages for accurate quantitation and unique capacity of high-throughput analysis. The strategy will be useful for the quantitation of fluorophores in the intact cells, such as measurement of multidrug resistance, quantitation of specific protein expression, and quantitative characterization of protein and enzyme functions.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Monolithic silica capillary column with coated cellulose tris(3,5-dimethylphenylcarbamate) for capillary electrochromatographic separation of enantiomers.

Monolithic silica capillary columns were prepared by a sol-gel process in fused-silica capillaries with an inner diameter of 50 microm and were modified by coating of cellulose tris(3,5-dimethylphenylcarbamate). Influences of the factors in the modification process on enantiomer separations were investigated. The prepared columns were used to perform enantiomer separations by CEC. Fifteen and two pairs of enantiomers were separated under aqueous and nonaqueous mobile phases, respectively, and most of them were baseline-separated with very high column efficiencies. The Van Deemter curve was found flat under high linear velocity of the mobile phase, which indicated favorable kinetic properties of the prepared columns. Baseline separation of a pair of enantiomers was achieved in 90 s with high-column efficiency by short-end separation under high voltage.

Cellulose↗

Large-pore mesoporous SBA-15 silica particles with submicrometer size as stationary phases for high-speed CEC separation.

A new mesoporous sphere-like SBA-15 silica was synthesized and evaluated in terms of its suitability as stationary phases for CEC. The unique and attractive properties of the silica particle are its submicrometer particle size of 400 nm and highly ordered cylindrical mesopores with uniform pore size of 12 nm running along the same direction. The bare silica particles with submicrometer size have been successfully employed for the normal-phase electrochromatographic separation of polar compounds with high efficiency (e.g., 210,000 for thiourea), which is matched well with its submicrometer particle size. The Van Deemeter plot showed the hindrance to mass transfer because of the existence of pore structure. The lowest plate height of 2.0 microm was obtained at the linear velocity of 1.1 mm/s. On the other hand, because of the relatively high linear velocity (e.g., 4.0 mm/s) can be generated, high-speed separation of neutral compounds, anilines, and basic pharmaceuticals in CEC with C18-modified SBA-15 silica as stationary phases was achieved within 36, 60, and 34 s, respectively.

Chromatography↗