PubMed Health⌕ Search

Biomedical subjects

Hanfa Zou

Publications and source records attributed to Hanfa Zou.

At least 37 records · Page 2Linked to original sources

Capillary electrochromatography with zwitterionic stationary phase on the lysine-bonded poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolithic capillary column.

A polymer-based neutral monolithic capillary column was prepared by radical polymerization of glycidyl methacrylate and ethylene dimethacrylate in a 100 mum id fused-silica capillary, and the prepared monolithic column was subsequently modified based on a ring opening reaction of epoxide groups with 1 M lysine in solution (pH 8.0) at 75 degrees C for 10 h to produce a lysine chemically bonded stationary phases in capillary column. The ring opening reaction conditions were optimized so that the column could generate substantial EOF. Due to the zwitterionic functional groups of the lysine covalently bonded on the polymer monolithic rod, the prepared column can generate cathodic and anodic EOF by varying the pH values of running buffer during CEC separation. EOF reached the maximum of -2.0 x 10(-8) m2v(-1)s(-1) and 2.6 x 10(-8) m2v(-1)s(-1) with pH of the running buffer of 2.25 and 10, respectively. As a consequence, neutral compounds, ionic solutes such as phenols, aromatic acids, anilines, and basic pharmaceuticals were all successfully separated on the column by CEC. Hydrophobic interaction is responsible for separation of neutral analytes. In addition, the electrostatic and hydrophobic interaction and the electrophoretic migration play a significant role in separation of the ionic or ionizable analytes.

Electrophoresis, Capillary↗

Hybrid silica monolithic column for capillary electrochromatography with enhanced cathodic electroosmotic flow.

A hybrid silica monolithic stationary phase for RP CEC was prepared by in situ co-condensation of (3-mercaptopropyl)-trimethoxysilane (MPTMS), phenyltriethoxysilane (PTES), and tetraethoxysilane (TEOS) via a sol-gel process. The thiol groups on the surface of the stationary phase were oxidized to sulfonic acids by peroxytrifluoroacetic acid. The introduced sulfonic acid moieties on the monoliths were characterized by a strong and relatively stable EOF in a broad pH range from 2.35 to 7.0 in CEC. Aromatic acids and neutral compounds can be simultaneously separated in this column under cathodic EOF. The CEC column exhibited a typical RP chromatographic mechanism for neutral compounds due to the introduced phenyl groups.

Amino Acids, Aromatic↗

Comprehensive two-dimensional HPLC to study the interaction of multiple components in Rheum palmatum L. with HSA by coupling a silica-bonded HSA column to a silica monolithic ODS column.

A mode of comprehensive 2-D LC was developed by coupling a silica-bonded HSA column to a silica monolithic ODS column. This system combined the affinity property of the HSA column and the high-speed separation ability of the monolithic ODS column. The affinity chromatography with HSA-immobilized stationary phase was applied to study the interaction of multiple components in traditional Chinese medicines (TCMs) with HSA according to their affinity to protein in the first dimension. Then the unresolved components retained on the HSA column were further separated on the silica monolithic ODS column in the second dimension. By hyphenating the 2-D separation system to diode array detector and MS detectors, the UV and molecular weight information of the separated compounds can also be obtained. The developed separation system was applied to analysis of the extract of Rheum palmatum L., a number of low-abundant components can be separated on a single peak from the HSA column after normalization of peak heights. Six compounds were preliminarily identified according to their UV and MS spectra. It showed that this system was very useful for biological fingerprinting analysis of the components in TCMs and natural products.

Chromatography, Affinity↗

Preparation and evaluation of a novel chiral stationary phase based on covalently bonded chitosan for ligand-exchange chromatography.

A novel chiral stationary phase based on chitosan covalently bonded onto silica gels has been prepared and used for the separation of various alpha-amino acid enantiomers as well as alpha-hydroxycarboxylic acid enantiomers by chiral ligand-exchange chromatography with copper(II) as a complexing ion. The methanol content and copper(II) ion concentration in the eluent affected retentivity and enantioselectivity. Furthermore, a plausible chiral recognition mechanism for resolution of alpha-amino acids was proposed.

5-Hydroxytryptophan↗

Monolithic enantiomer-selective stationary phases for capillary electrochromatography.

Monolithic materials have become a well-established format for stationary phases in the field of capillary electrochromatography. Four types of monoliths, namely particle-fixed, silica-based, polymer-based, and molecularly imprinted monoliths, have been utilized as enantiomer-selective stationary phases in CEC. This review summarizes recent developments in the area of monolithic enantiomer-selective stationary phases for CEC. The preparative procedure and the characterization of these columns are highlighted. In addition, the disadvantages and limitations of different monolithic enantiomer-selective stationary phases in CEC are briefly discussed.

Amino Acids↗

Iminodiacetic acid derivatized porous silicon as a matrix support for sample pretreatment and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis.

Iminodiacetic acid (IDA)-1,2-epoxy-9-decene has been synthesized and covalently linked to the surface of porous silicon wafer through a photochemical reaction. The negatively charged carboxylic acid groups on the porous silicon wafer are capable of binding oppositely charged species from sample solutions through electrostatic interactions. This allows the removal of contaminants prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) by simply washing the porous silicon surface. The carboxylic acid end groups on porous silicon can be used to selectively bind and concentrate target species in sample solutions. Furthermore, Fe(3+)-IDA-derivatized porous silicon was prepared to specifically and effectively concentrate phosphopeptides from the tryptic digests of phosphoproteins, followed by MALDI-MS analysis.

Caseins↗

Coupling the immobilized trypsin microreactor of monolithic capillary with muRPLC-MS/MS for shotgun proteome analysis.

A nanoliter trypsin-based monolithic microreactor coupled with muRPLC-MS/MS was reported for shotgun proteome analysis. The proteins were rapidly digested by the microreactor, and the resulting protein digests were directly loaded onto a muRPLC column for separation followed with detection of the eluted peptides by tandem mass spectrometer. The digestion efficiency and stability of the microreactor was demonstrated by using bovine serum albumin as a model protein. When compared with an incubation time of more than 10 h by free trypsin in the conventional digestion approach, protein mixtures can be digested by the microreactor in several minutes. This system was applied to the analysis of the total cell lysate of Saccharomyces cerevisiae. After a Sequest database search, a total of 1578 unique peptides corresponding to 541 proteins were identified when 590 ng yeast protein was digested by the microreactor with an incubation time of only 1 min.

Animals↗

Enrichment of phosphopeptides by Fe3+-immobilized mesoporous nanoparticles of MCM-41 for MALDI and nano-LC-MS/MS analysis.

Fe3+-immobilized mesoporous molecular sieves MCM-41 with particle size of ca. 600 nm and pore size of ca. 3 nm is synthesized and applied to selectively trap and separate phosphopeptides from tryptic digest of proteins. For the capture of phosphopeptides, typically 10 microL of tryptic digest solution was first diluted to 1 mL by solution of ACN/0.1% TFA (50:50, v/v) and incubated with 10 microL of 0.1% acetic acid dispersed Fe3+-immobilized MCM-41 for 1 h under vibration. Fe3+-immobilized MCM-41 with trapped phosphopeptides was separated by centrifugation. The deposition was first washed with a volume of 300 microL of solution containing 100 mM NaCl in ACN/0.1% TFA (50:50, v/v) and followed by a volume of 300 microL of solution of 0.1% acetic acid to remove nonspecifically bound peptides. The nanoparticles with trapped phosphopeptides are mixed with 2,5-dihydroxybenzoic acid (2,5-DHB) and deposited onto the target for analysis by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). It was found that phosphopeptides from tryptic digest of alpha-casein and beta-casein are effectively and specifically trapped on Fe3+-immobilized MCM-41 with few peptides nonspecifically adsorbed. After the extraction by Fe3+-immobilized MCM-41, the suppression to the detection of phosphopeptides caused by abundant nonphosphopeptides from tryptic digest is effectively eliminated, and the detection of phosphopeptides by MALDI is greatly enhanced with the value of signal-to-noise (S/N) increased by more than an order of magnitude. It is demonstrated that the mechanism of the adsorption of phosphopeptides on Fe3+-immobilized MCM-41 is based on the interaction between the Fe3+ and the phosphate group. Finally, Fe3+-immobilized MCM-41 is applied to extract phosphopeptides from tryptic digest of the lysate of mouse liver for phosphoproteome analysis by nano-LC-MS/MS.

Amino Acid Sequence↗

Zirconium phosphonate-modified porous silicon for highly specific capture of phosphopeptides and MALDI-TOF MS analysis.

Phosphorylation is one of the most important post-translational modifications of proteins, which modulates a wide range of biological functions and activity of proteins. The analysis of phosphopeptides is still one of the most challenging tasks in proteomics research by mass spectrometry. In this study, a novel phosphopeptide enrichment approach based on the strong interaction of zirconium phosphonate (ZrP) modified surface with phosphopeptides has been developed. ZrP modified porous silicon (ZrP-pSi) wafer was prepared to specifically capture the phosphopeptides from complex peptide mixtures, and then the captured phosphopeptides were analyzed by MALDI-TOF MS by directly placing the wafer on a MALDI target. The phosphopeptide enrichment and MALDI analysis were both performed on the ZrP-pSi wafer which significantly reduced the sample loss and simplified the analytical procedures. The prepared ZrP-pSi wafer has been successfully applied for the enrichment of phosphopeptides from the tryptic digest of standard phosphoproteins beta-casein and alpha-casein. The excellent selectivity of this approach was demonstrated by analyzing phosphopeptides in the digest mixture of beta-casein and bovine serum albumin with molar ratio of 1:100. High detection sensitivity has been achieved for the analysis of the phosphopeptides from tryptic digestion of 2 fmol beta-casein on the ZrP-pSi surface.

Amino Acid Sequence↗

Octadecylated silica monolith capillary column with integrated nanoelectrospray ionization emitter for highly efficient proteome analysis.

An improved strategy for the preparation of octadecylated silica monolith capillary column with high homogeneity was proposed. Column performance was evaluated by nanoscale HPLC. The design for constructing an integrated nanoelectrospray emitter on the octadecylated silica monolith capillary column was first introduced. In comparison with the separated configuration where the emitter is connected to monolithic capillary column by the aid of a zero dead volume union, the integrated capillary column has the inherent advantage of the minimized extracolumn volume thus providing improved separation quality. The performance of the integrated monolithic capillary column was evaluated by separation of BSA tryptic digest, and peak capacity of 313 with a 30-cm column was obtained. The high separation performance allowed highly confident identification of 662 distinct proteins through assignment of 1933 unique peptides by analysis of tryptic digest of 0.5 mug of Saccharomyces cerevisiae proteins. The higher separation efficiency by a 60-cm monolithic capillary column increased the proteome coverage with identification of 1323 proteins through assignment of 5501 unique peptides over 400-min gradient elution.

Chromatography, High Pressure Liquid↗

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with a matrix of carbon nanotubes for the analysis of low-mass compounds in environmental samples.

The use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for environmental analysis has been mainlyfocused on qualitative analysis of high-mass molecules, such as toxins, humic acid, and microorganisms. Herein,we describe a novel MALDI-TOF-MS method with a matrix of oxidized carbon nanotubes for analysis of low-mass compounds in environmental samples. A number of chemicals in the environment were qualitatively analyzed by the present method, and it was found that most of them, especiallythe highly polar chemicals, were measurable with high sensitivity. With the intrinsic ability to measure high-mass chemicals, this method can compensate for the current shortage of methods for environmental analysis for the measurement of highly polar or high-mass chemicals. For sample analysis, arsenic speciation in Chinese traditional medicines was qualified and diphenylolpropane in water samples was quantified. With the relatively high tolerance of the method to interfering molecules, a simple pretreatment or even no pretreatment could be employed before MS detection. Furthermore, this method can be employed in a high-throughput format.

Arsenic↗

Improved performance of comprehensive two-dimensional HPLC separation of traditional Chinese medicines by using a silica monolithic column and normalization of peak heights.

Performance of comprehensive two-dimensional liquid chromatography system is greatly improved than we reported previously by using a silica monolithic column as for the second dimensional separation. Due to the increase of the elution speed on the second dimensional monolithic column, the first dimensional column efficiency and analysis rate can be greatly improved as comparing with conventionally second dimensional column. The developed system was applied to analysis of methanol extraction of two umbelliferae herbs Ligusticum chuanxiong Hort. and Angelica sinensis (Oliv.) Diels by using CN column as for the first dimensional separation and a silica monolithic ODS column for the second dimensional separation, and the obtained three-dimensional chromatograms were treated by normalization of peak heights with the value of the highest peak or setting a certain value using a software written in-house. It was observed that much more peaks for low-abundant components in TCM extract can clearly be detected here than we reported before, due to the large difference for the amount of components in TCMs' extract. With the above improvements in separation performance and data treatment, totally about 120 components in methanol extraction of Rhizoma chuanxiong and 100 in A. sinensis were separated with UV detection within 130 min. This result meant that both the number of peaks detected increase twice but the analysis time decrease twice if comparing with the previously reported result.

Apiaceae↗

Integration of ion-exchange chromatography fractionation with reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for isolation and identification of compounds in Psoralea corylifolia.

An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with detection of UV absorbance and atmospheric pressure chemical ionization mass spectrometer (APCI/MS), respectively, and also analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes. Totally more than 188 components in P. corylifolia extract were detected with this integrated approach, and 12 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS. The obtained analytical results not only demonstrated the powerful resolution of integration IEC fractionation with reversed-phase liquid chromatography (RPLC)-APCI/MS and MALDI-TOF/MS for analysis of compounds in a complex sample, but also exhibited the superiority of APCI/MS and MALDI-TOF/MS for identification of low-mass compounds, such as for study of traditional Chinese medicines (TCMs) and metabolome.

Atmospheric Pressure↗

Separation and detection of compounds in Honeysuckle by integration of ion-exchange chromatography fractionation with reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis.

A hyphenated method for the isolation and identification of components in a traditional Chinese medicine of Honeysuckle was developed. Ion-exchange chromatography (IEC) was chosen for the fractionation of Honeysuckle extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further analyzed by reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer (RPLC-APCI/MS) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes, respectively. It can be noted totally more than 117 components were detected by UV detector, APCI/MS and MALDI-TOF/MS in Honeysuckle extract except the 145 components identified by MALDI-TOF/MS alone with this integrated approach, and 7 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS, respectively. The obtained analytical results not only indicated the approach of integration IEC fractionation with RPLC-APCI/MS and MALDI-TOF/MS is capable of analyzing complex samples, but also exhibited the potential power of the mass spectrometer in detection of low-mass compounds, such as traditional Chinese medicines (TCMs) and complex biological samples.

Chromatography, Ion Exchange↗

Screening and analysis of bioactive compounds with biofingerprinting chromatogram analysis of traditional Chinese medicines targeting DNA by microdialysis/HPLC.

Biofingerprinting chromatogram analysis, which is defined as the comparison of fingerprinting chromatograms of the extract of traditional Chinese medicines (TCMs) before and after the interaction with biological systems (DNA, protein, cell, etc.), was proposed for screening and analysis of the multiple bioactive compounds in TCMs. A method of microdialysis sampling combined with high performance liquid chromatography (HPLC) was applied to the study of DNA-binding property for the extracts of TCMs. Seven compounds were found to bind to calf thymus DNA (ct-DNA) from the TCMs of Coptis chinensis Franch (Coptis), but only three ones from Phellodendron amurense Rupr. (Phellodendron) and none from Sophoraflavescens Ait. (Sophora) to bind to ct-DNA, respectively. Three of them were identified as berberine, palmatine and jatrorrhizine and their association constants (K) to ct-DNA were determined by microdialysis/HPLC. Competitive binding behaviors of them to ct-DNA were also investigated.

Animals↗

Using oxidized carbon nanotubes as matrix for analysis of small molecules by MALDI-TOF MS.

Oxidized carbon nanotubes are tested as a matrix for analysis of small molecules by matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS). Compared with nonoxidized carbon nanotubes, oxidized carbon nanotubes facilitate sample preparation because of their higher solubility in water. The matrix layer of oxidized carbon nanotubes is much more homogeneous and compact than that of nonoxidized carbon nanotubes. The efficiency of desorption/ionization for analytes and the reproducibility of peak intensities within and between sample spots are greatly enhanced on the surface of oxidized carbon nanotubes. The advantage of the oxidized carbon nanotubes in comparison with alpha-cyano-4-hydroxycinnamic acid (CCA) and carbon nanotubes is demonstrated by MALDI-TOF-MS analysis of an amino acid mixture. The matrix is successfully used for analysis of synthetic hydroxypropyl beta-cyclodextrin, suggesting a great potential for monitoring reactions and for product quality control. Reliable quantitative analysis of jatrorrhizine and palmatine with a wide linear range (1-100 ng/mL) and good reproducibility of relative peak areas (RSD less than 10%) is achieved using this matrix. Concentrations of jatrorrhizine (8.65 mg/mL) and palmatine (10.4 mg/mL) in an extract of Coptis chinensis Franch are determined simultaneously using the matrix and a standard addition method.

Calibration↗

Electrochromatographic evaluation of a silica monolith capillary column for separation of basic pharmaceuticals.

A silica-based monolithic capillary column was prepared via a sol-gel process. The continuous skeleton and large through-pore structure were characterized by scanning electron microscopy (SEM). The native silica monolith has been successfully employed in the electrochromatographic separation of beta-blockers and alkaloids extracted from traditional Chinese medicines (TCMs). Column efficiencies greater than 250 000 plates/m for capillary electrochromatography (CEC) separation of basic compounds were obtained. It was observed that retention of basic pharmaceuticals on the silica monolith was mainly contributed by a cation-exchange mechanism. Other retention mechanisms including reversed-phase and normal-phase mechanisms and electrophoresis of basic compounds also played a role in separation. A comparison of the differences between CEC and capillary zone electrophoresis (CZE) separation was also discussed.

Adrenergic beta-Antagonists↗

Capillary electrochromatographic separation of enantiomers under aqueous mobile phases on a covalently bonded cellulose derivative chiral stationary phase.

A chemically bonded cellulose tris(3,5-dimethylphenylcarbamate) chiral stationary phase (CSP) was prepared by a radical polymerization reaction. The prepared CSP was packed into fused-silica capillaries with inner diameter of 75 microm to perform enantiomer separations in CEC. The electrochromatographic behavior of the CSP was investigated. On the prepared CSP, high EOF could be generated under acidic mobile phases, which represented an advantage for the separation of acidic enantiomers. Several neutral, acidic, and basic enantiomers were resolved on the prepared CSP under aqueous mobile phases. The column efficiencies were between 20,000 and 100,000 plates/m, which were much higher than those of HPLC. In addition, it was observed that the separation of some enantiomers benefited from the adoption of THF as mobile phase modifier.

Cellulose↗