PubMed Health⌕ Search

Biomedical subjects

Hanfa Zou

Publications and source records attributed to Hanfa Zou.

At least 73 records · Page 4Linked to original sources

[Cross-linked beta-cyclodextrin polymer used for bilirubin removal].

A new material for adsorption of bilirubin was synthesized with cross-linking reaction of beta-cyclodextrin. The kinetic adsorption behaviors of bilirubin such as the effects of temperature, pH, the initial bilirubin concentration as well as bovine seum albumin on the removal of bilirubin have been investigated. It is demonstrated that bilirubin could be adsorbed well on the prepared sorbent quickly and higher temperature favored the adsorpion of bilirubin. The percentage of removal of bilirubin reached 92.6% with initial bilirubin concentration of 40 mg/L in phosphate buffer at pH 7.8. With the increase of initial bilirubin concentration, the percentage of removal of bilirubin decreased; however, the adsorption capacity increased.

Adsorption↗

[Preparation of covalently bonded cellulose tris (4-methylbenzoate) derivative chiral stationary phases through a polymerization reaction].

Cellulose tris (4-methylbenzoate) derivatives (CTMB) having methacryloyl groups were synthesized with regio-selective or nonselective procedures, and were immobilized on gamma-methacrylatepropylated silica (gamma-MAPS) through a polymerization reaction. The obtained chiral stationary phases ( CSPs) were evaluated by high performance liquid chromatographic (HPLC) resolution of 9 racemates (3-butyl-phthalide, ketoprofen, trans-stilbene oxide, benzoin, benzoin analogue, Tröger' s base, warfarin, 4,4'-dimethoxy-5,6,5',6'-dimethylenedioxy-biphenyl-2,2'-dicarboxylate and 4,4'-dimethoxy-5,6,5',6'-dimethylenedioxy-biphenyl-2-methylcarboxylate-2'-ethylcarboxylate). For regio-nonselective procedure, increasing the content of vinyl group on CTMB would lead to higher immobilization efficiency and enantio-selectivity. CSPs prepared by regio-selective procedure possessed slightly higher enantioselectivities than those prepared by regio-nonselective procedure, while the latter showed some advantages for rapid and facile preparation. CSPs prepared with silica gel II (Fuji, 5 microm, 30 nm, ca. 150 m2/g) showed higher enantioselectivities than those prepared with silica gel I (Kromasil, 5 microm, 20 nm, ca. 240 m2/g). The prepared CSPs could keep stable under different eluents, even with 40% of tetrahydrofuran (THF) in mobile phases.

Benzoates↗

Carbon nanotubes as assisted matrix for laser desorption/ionization time-of-flight mass spectrometry.

Analysis of low molecular weight compounds with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed by using carbon nanotubes obtained from coal by arc discharge as the matrix. The carbon nanotube matrix functions as substrate to trap analytes of peptides, organic compounds, and beta-cyclodextrin deposited on its surface. It has been found that carbon nanotubes can transfer energy to the analyte under laser irradiation, which makes analytes well desorbed/ionized, and the interference of intrinsic matrix ions can be eliminated. At the same time, the fragmentation of the analyte can be avoided. A good sensitivity and excellent reproducibility of the spectrum signals are achieved. It is believed that this work not only will open a new field for applications of carbon nanotubes, but also will offer a new technique for high-speed analysis of low molecular weight compounds in areas such as metabolism research and characterization of natural products.

Cyclodextrins↗

Synthesis of covalently bonded cellulose derivative chiral stationary phases with a bifunctional reagent of 3-(triethoxysilyl)propyl isocyanate.

A bifunctional reagent of 3-(triethoxysilyl)propyl isocyanate (TEPI) was initially adopted as a spacer reagent to prepare the bonded types of chiral stationary phases (CSPs) with cellulose derivatives. The silica-based CSPs were chemically prepared with non-regioselective and regioselective approaches and their chiral resolving capabilities were evaluated in terms of HPLC resolution of test enantiomers. It was observed that the chiral recognition capabilities of the non-regioselectively prepared CSPs were influenced by the amount of TEPI used. And also, the regioselectively prepared CSP generally showed a slightly higher resolution power than the non-regioselectively prepared CSP, while the non-regioselective procedures were highly advantageous to rapid preparation. In addition, chiral recognition of the prepared CSPs was affected by the properties of the used silica matrices.

Cellulose↗

Unilamellar liposomes covalently coupled on silica gel for liquid chromatography.

Silica gel was used as a support for the covalent coupling of liposomes, which could overcome drawbacks of soft gel beads in column efficiency and separation speed. The influences of the concentration of added dimethylaminopyridine and reaction time on the chloroformate activation reaction of silica gel were investigated. Temperature and pH for covalent coupling of liposomes on the activated silica gel were also optimized. Experimental results indicated that the stability of the covalently coupled liposome columns was obviously superior to that of the noncovalently coated liposome columns but the selectivity of both columns was basically identical. Separation and analysis of a crude extract of a traditional Chinese medicine Ligusticum Wallichii and a mixture of small peptides on both columns further support this conclusion.

Chromatography, High Pressure Liquid↗

Molecularly imprinted monolithic stationary phases for liquid chromatographic separation of enantiomers and diastereomers.

The method for preparation of molecularly imprinted monolithic stationary phase has been improved to achieve liquid chromatographic separation of enantiomers and diastereomers. By adopting low polar porogenic solvents of toluene and dodecanol and optimal polymerization conditions, the molecularly imprinted monolithic stationary phases with good flow-through properties and high resolution were prepared. Enantiomers of amino acid derivatives and diastereomers of cinchona alkaloids were completely resolved using the monolithic stationary phases. The influence of porogenic composition, monomer-template ratio and polymerization conditions on the chromatographic performance was investigated. Some chromatographic conditions such as the composition of the mobile phase and the temperature were characterized. Scanning electron microscopy showed that the molecularly imprinted monolithic stationary phase has a large through-pore structure to allow the mobile phase to flow through the column at very low backpressure. Accelerated separations of enantiomers and diastereomers were therefore achieved at elevated flow rates. Finally, the chiral recognition performance of the prepared stationary phase in aqueous media was investigated. Hydrophobic interaction, and ionic and/or hydrogen bonding interactions were proposed to be responsible for the recognition mechanism.

Chromatography, High Pressure Liquid↗

Peptide separation in hydrophilic interaction capillary electrochromatography.

Separation of small peptides by hydrophilic interaction capillary electrochromatography (HI-CEC) has been investigated. The negative surface charge of a hydrophilic, strong-cation-exchange stationary phase (PolySULFOETHYL A) provided a substantial cathodic electroosmotic flow (EOF). The influence of acetonitrile content, ionic strength, mobile phase pH as well as applied voltage on the migration of the peptides was studied. Possible retention mechanisms of the peptides in HI-CEC were discussed. It was found that hydrophilic interaction between the solutes and the stationary phase played a major role in this system, especially when mobile phases with high acetonitrile content were used. However, an ion-exchange mechanism and electrophoretic mobility also affect the migration of the peptides in HI-CEC. Elution order and selectivity was proved to be different in HI-CEC and capillary zone electrophoresis (CZE), thus revealing the potential of HI-CEC as a complementary technique to CZE for the separation of peptides. Efficiency and selectivity of HI-CEC for the separation of peptides were demonstrated by baseline separating nine peptides in 6 min.

Chromatography, Micellar Electrokinetic Capillary↗

Capillary electrochromatographic separation of enantiomers on chemically bonded type of cellulose derivative chiral stationary phases with a positively charged spacer.

Positively charged chiral stationary phases (CSPs) were prepared for capillary electrochromatography (CEC) separation of enantiomers by chemically immobilizing cellulose derivatives onto diethylenetriaminopropylated silica (DEAPS) with tolylene-2,4-diisocyanate (TDI) as a spacer reagent. Anodic electroosmotic mobility was observed in both nonaqueous and aqueous mobile phases due to the positively charged amines on the surface of the prepared CSPs. For comparison, the traditionally used 3-aminopropyl silica (APS) was also adopted as the base material instead of DEAPS to prepare CSP. It was observed that the EOF on the DEAPS-based CSP was 18%-60% higher than that on the APS-based CSP under nonaqueous mobile phase conditions. Separation of enantiomers in CEC was performed on the positively charged CSPs with the nonaqueous mobile phases of pure ethanol or mixture of hexane-alcohol and the aqueous phases of acetonitrile-water or 95% ethanol. Fast separation of enantiomers was achieved on the newly prepared CSPs.

Cellulose↗

Optimized preparation of poly(styrene-co- divinylbenzene-co-methacrylic acid) monolithic capillary column for capillary electrochromatography.

Preparation of a poly(styrene-co-divinylbenzene-co-methacrylic acid) monolithic stationary phase for the use in capillary electrochromatography (CEC) has been improved by optimizing the polymerization conditions. It is observed that the reaction time strongly affects column efficiency, while the proportion of isooctane in porogen influences peak symmetry of some solutes seriously. The lifetime of the monolithic columns prepared mainly depends on the pH of buffers used. Reproducibility of electroosmotic flow (EOF) from batch to batch columns are lower than 2.8% relative standard deviation. Unlike other types of capillary electrochromatographic monoliths, a pH-dependent EOF was observed on this type of column. Separation of various types of compounds including aromatic hydrocarbons, hormones, anilines, basic pharmaceuticals, and peptides was achieved. The facile preparation and wide application of this monolithic column may make styrene-based polymer a potential stationary phase in CEC.

Aniline Compounds↗

Immobilized metal-ion chelating capillary microreactor for peptide mapping analysis of proteins by matrix assisted laser desorption/ ionization-time of flight-mass spectrometry.

Peptide mass mapping analysis, utilizing a regenerable enzyme microreactor with metal-ion chelated adsorption of enzyme, combined with matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) was developed. Different procedures from the conventional approaches were adopted to immobilize the chelator onto the silica supports, that is, the metal chelating agent of iminodiacetic acid (IDA) was reacted with glycidoxypropyltrimethoxysilane (GLYMO) before its immobilization onto the inner wall of the fused-silica capillary pretreated with NH(4)HF(2). The metal ion of copper and subsequently enzyme was specifically adsorbed onto the surface to form the immobilized enzyme capillary microreactor, which was combined with MALDI-TOF-MS to apply for the mass mapping analysis of nL amounts of protein samples. The results revealed that the peptide mapping could routinely be generated from 0.5 pmol protein sample in 15 min at 50 degrees C, even 20 fmol cytochrome c could be well digested and detected.

Adsorption↗

The separation of biomolecules using capillary electrochromatography.

The unique properties of capillary electrochromatography such as high performance, high selectivity, minimum consumption of both reagents and samples, and good compatibility with mass spectrometry make this technique an attractive one for the analysis of biomolecules including peptides, proteins, carbohydrates, nucleosides and nucleotides. Irreversible adsorption between the biomolecules and the charged packing surface leads to a lack of reproducibility and serious peak tailing, so various approaches have been taken to overcome this and to improve the technique for future challenges.

Biopolymers↗

High-performance affinity chromatography with immobilization of protein A and L-histidine on molded monolith.

Reactive monoliths of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) have been prepared by "in-situ" copolymerization of the monomers in the presence of porogenic diluents. Protein A and L-histidine were immobilized on the monoliths directly or through a spacer arm, respectively. The properties of these two kinds of affinity columns were characterized, and the results showed that the columns with coupling of ligands by a spacer arm have some extent of non-specific adsorption for bovine serum albumin. The affinity column based on the monolithic polymer support provided us with good hydrodynamic characteristic, low flow resistance, and easy preparation. These two affinity columns were used for the purification of immunoglobulin G from human serum. The purity of the purified IgG was detected by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The stability of the protein A affinity column was investigated, and its performance remained invariable after half a year. The effects of the nature and the pH of the buffer system on the adsorption capacity of human IgG on histidyl affinity column were also investigated. The protein A affinity column is favorable for rapid analysis of human IgG samples. In contrast, the advantages of mild elution conditions, high stability, as well as low cost provide the histidyl column further potential possibility for fast removal of IgG from human plasma in clinical applications.

Adsorption↗

Screening and analysis of permeable compounds in Radix Angelica Sinensis with immobilized liposome chromatography.

Immobilized liposome chromatography (ILC) was used to screen and analyze permeable compounds in traditional Chinese medicines (TCMs), testing extracts from Radix Angelica Sinensis. More than 10 peaks were resolved based on their interactions with the ILC stationary phase, a system which mimics biomembranes; this means that more than 10 components in Radix Angelica Sinensis extract have significant retention on an ILC column. Two of them, ligustilide and ferulic acid, were identified from their MS spectrum and with standard samples. A possible molecular structure of another component retained on ILC was also preliminarily identified as 3-butylidene-4,5-dihydro-2(1,3H)-1-isobenzofuranol according to its MS spectrum, hydrophobicity and 1H NMR spectrum. Of all detected components, ligustilide had the best penetration ability through the biomembrane. The effects of pH, column temperature, and ionic strength on the chromatography of methanolic extracts of Radix Angelica Sinensis were also investigated. It was found that the separation selectivity on ILC is strongly affected by the eluent pH, but only slightly by the column temperature and ionic strength.

Angelica sinensis↗

High-performance affinity chromatography for characterization of human immunoglobulin G digestion with papain.

Reactive continuous rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) were prepared within the confines of a stainless steel column. Then papain was immobilized on these monoliths either directly or linked by a spacer arm. In a further step, a protein A affinity column was used for the characterization of the digestion products of human immunoglobulin G (IgG) by papain. The results showed that papain immobilized on the monolithic rod through a spacer arm exhibits higher activity for the digestion of human IgG than that without a spacer arm. The apparent Michaelis-Menten kinetic constants of free and immobilized papain, K(m) and V(max), were determined. The digestion conditions of human IgG with free and immobilized papain were optimized. Comparison of the thermal stability of free and immobilized papain showed that the immobilized papain exhibited higher thermal stability than the free enzyme. The half-time of immobilized papain reaches about a week under optimum pH and temperature conditions.

Chromatography, Affinity↗

Monolithic stationary phases for liquid chromatography and capillary electrochromatography.

A monolithic stationary phase is the continuous unitary porous structure prepared by in situ polymerization or consolidation inside the column tubing and, if necessary, the surface is functionalized to convert it into a sorbent with the desired chromatographic binding properties [J. Chromatogr. A 855 (1999) 273]. Monolithic stationary phases have attracted considerable attention in liquid chromatography and capillary electrochromatography in recent years due to their simple preparation procedure, unique properties and excellent performance, especially for separation of biopolymers. This review summarizes the preparation, characterization and applications of the monolithic stationary phases. In addition, the disadvantages and limitations of the monolithic stationary phases are also briefly discussed.

Chromatography, Liquid↗

A method for the analysis of low-mass molecules by MALDI-TOF mass spectrometry.

We report a novel method termed matrix suppressed laser desorption/ionization to improve the analysis of low-mass molecules by MALDI-TOF mass spectrometry. In this method, the surfactant of cetrimonium bromide (CTAB) is added to the conventional matrix of alpha-cyano-4-hydroxycinnamic acid solution to prepare the MALDI samples. During the MALDI process, the presence of CTAB could substantially or even completely suppress the matrix-related ion background. As a result, very clean mass spectra can be routinely obtained in the low-mass range. In addition, the presence of CTAB can significantly improve the mass resolution of low-mass molecules. It is seen that high-quality spectra were routinely obtained at a matrix/CTAB ratio of 1000:1. This method has been successfully used to analyze a variety of low-mass molecules.

Amino Acids↗