Survival after radical resection of cardiac sarcomas.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Hans H Scheld.
Explore the source record for details and available documents.
BACKGROUND: In patients with chronic heart failure (CHF), chronic kidney disease (CKD) is associated with increased morbidity and mortality, but contributing mechanisms are not well defined. This study tested the impact of CKD on intracardiac conduction, diastolic function and prognosis in patients with underlying CHF. METHODS: We prospectively enrolled 269 patients with stable CHF, of whom 135 had CKD (estimated glomerular filtration rate (eGFR)<60 ml/min/1.73 m(2)). Echo measurements comprised left ventricular dimensions/volumes, ejection fraction, mitral E/A-ratio, deceleration time and tissue Doppler mitral annular velocities (S', E', A'). PQ and QRS intervals were derived from the 12-lead ECG. A cardiac event (cardiac death or urgent cardiac transplantation) was defined as combined study end point. RESULTS: Patients with CKD had longer PQ and QRS intervals, and were in a poorer NYHA functional class as compared to patients without CKD. In patients with CKD, the mitral annular E' velocity was lower, the mitral E/E'-ratio was higher and a restrictive mitral filling pattern was more frequent. By linear regression analysis, PQ and QRS intervals and the mitral E/E'-ratio were inversely related to the eGFR. During a follow-up of 507+/-375 days, 39 patients suffered a cardiac event. In CKD patients, outcome was markedly poorer as compared to those without CKD (event-free survival rate 51% vs. 87% in those without KD, p=0.001) CONCLUSIONS: In patients with CHF, CKD is associated with impaired intracardiac conduction and progressive diastolic dysfunction. Both mechanisms may contribute to increased morbidity and mortality of such patients.
BACKGROUND: Left ventricular assist devices (LVADs) with continuous flow properties are increasingly used to bridge heart failure patients to cardiac transplantation. Advantages in comparison with the pulsatile LVADs are smaller size, better endurance, and lower thromboembolic events. However, whether these new pumps have similar pre- and posttransplant outcomes is not clear. METHODS: Fifty patients with a continuous flow device (Micromed DeBakey, Houston, TX or InCor BerlinHeart, Berlin, Germany) were compared with an age-, disease-, and LVAD duration-matched control group (n = 80) supported with a pulsatile device (Novacor, WorldHeart, Oakland, CA or HeartMate, Thoratec Corp, Pleasanton, CA). RESULTS: Age (44.3 +/- 13.4 vs 46.1 +/- 11.1 years), disease (idiopathic dilated cardiomyopathy, 58% vs 65%), and LVAD duration (138 +/- 131 vs 128 +/- 106 days) were comparable in both groups. Successful bridging to transplantation was similar with continuous flow in comparison with pulsatile device support (52% vs 56%, p = not significant [NS]). Thirty-day mortality after cardiac transplantation in patients with continuous flow LVAD support was 21.7% vs 22.2% with pulsatile LVADs (p = NS). Reasons for death were similar among the different LVAD groups. Long-term survival was similar in both LVAD groups compared with patients without previous LVAD support. Interestingly, severe rejections were significantly more frequent in patients with a continuous flow LVAD (p < 0.001). CONCLUSIONS: The new generation of cardiac assist devices with continuous flow pattern has a similar rate of pre- and posttransplant mortality in comparison with pulsatile LVADs. However, the rate and severity of posttransplant rejection was significantly higher in the group with continuous flow devices. Further studies are warranted to explain the higher rate of severe rejections.
BACKGROUND: Pulmonary hypertension (PHT), defined as a pulmonary vascular resistance (PVR) greater than 2.5 Wood units [WU] and(or) transpulmonary gradient (TPG) greater than 12 mm Hg, is a risk factor for mortality in cardiac transplantation due to elevated postoperative right heart failure. Orthotopic heart transplantation is possible if PVR could be reversed below 2.5 WU and TPG below 12 mm Hg. We show the Muenster experience from the last 10 years. METHODS: From April 1996 to December 2005 all cardiac transplant recipients separated into patients with and without PHT were included. All patients with PHT had successful reduction (PVR < or = 2.5 WU and TPG < or = 12 mm Hg) using prostaglandin I2 or E1. Posttransplant early and late mortality and incidence of right heart failure were studied. RESULTS: Two hundred seventeen patients were included in this study. Of these, 168 had normal pulmonary pressures (non-PHT group), 49 (22.6%) had reversible PHT (rev-PHT group). Mean PVR was 1.6 +/- 1.1 WU vs 2.1 +/- 1.1 WU (p < 0.01; non-PHT vs rev-PHT) and mean TPG 8.0 +/- 1.9 mm Hg vs 10.6 +/- 4.1 mm Hg (p = not significant [NS]). Thirty-day survival after orthotopic cardiac transplantation was 85% vs 78% (p = 0.150) and 10 year survival 63% vs 61% (p = NS). Right heart failure during the first 30 days after transplantation occurred in 27% in the non-PHT group and in 64% in the rev-PHT group (p = 0.035). However, in patients transplanted after 2001 it did not appear. CONCLUSIONS: Cardiac transplant candidates with reversible PHT have still significantly elevated pulmonary pressures compared with patients without PHT. Despite a significantly higher risk of right heart failure, long-term survival after orthotopic cardiac transplantation was not affected.
BACKGROUND: It was the aim of this study to compare the prognostic impact of echocardiography and brain natriuretic peptide and its N-terminal fragment (NT-proBNP) in patients with chronic heart failure (CHF). METHODS: In all, 73 patients with CHF underwent conventional 2-dimensional/Doppler echocardiography and Doppler tissue analysis of systolic, early and late diastolic mitral annular velocities. The mitral filling pattern was classified as restrictive or nonrestrictive. NT-proBNP measurements were carried out on a bench-top analyzer. A cardiac event (rehospitalization caused by worsening CHF, cardiac death, urgent cardiac transplantation) was defined as combined study end point. RESULTS: During follow-up of 226 +/- 169 days, 27 patients had an event (rehospitalization because of CHF, n = 18; cardiac death, n = 7; urgent transplantation, n = 2). On multivariate Cox regression analysis, a restrictive filling pattern, NT-proBNP, the ratio of peak early diastolic mitral flow to mitral annular E' velocity were independent prognostic predictors. A risk stratification model based on the 3 strongest independent predictors separated groups into those with good, intermediate, and poor outcome (event-free survival of 78%, 46%, and 0%, respectively). CONCLUSIONS: In patients with CHF, Doppler echocardiography, Doppler tissue imaging, and NT-proBNP provide independent and incremental prognostic information. A combined use of echocardiography and NT-proBNP may help to improve risk stratification in this patient population.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Because of the scarcity of donor hearts, surgical alternatives to heart transplantation, such as partial left ventriculectomy (PLV), were introduced for treatment of advanced heart failure. Here, we report our experience with this procedure performed in combination with mitral valve repair. METHODS: Twelve patients with dilated cardiomyopathy (DCM), New York Heart Association (NYHA) class exceeding III on maximal medical therapy, cardiac index of 2.5 liter/min/m2 or less, VO2max of 14 ml/kg/min or less, left ventricular end-diastolic diameter (LVEDD) of 7.0 cm or more, and grade II or greater mitral incompetence, were selected for PLV and mitral valve reconstruction (MVR). Echocardiography, hemodynamics, spiroergometry, and clinical assessment were performed before and 1 year after the operation. RESULTS: One-year survival was 83.3%. All 10 surviving patients were free from failure of the procedure 1 year post-operatively. From pre-operatively to 1 year post-operatively, NYHA functional class improved from 3.3 +/- 0.3 to 1.9 +/- 0.2 (p < 0.001), cardiac index increased from 2.0 +/- 0.2 liter/min/m2 to 2.9 +/- 0.2 liter/min/m2 (p < 0.001), stroke volume index from 25.9 +/- 4.8 ml/m2 to 40.3 +/- 7.3 ml/m2 (p = 0.008), and VO2max from 10.9 +/- 2.4 ml/kg/min to 16.0 +/- 3.6 ml/kg/min (p = 0.016), whereas LVEDD decreased from 8.4 +/- 0.6 cm to 6.6 +/- 0.3 cm (p < 0.001), left ventricular end-systolic diameter from 6.8 +/- 0.8 cm to 5.3 +/- 0.5 cm (p < 0.001), and mitral incompetence from 2.4 +/- 0.6 to 0.9 +/- 0.6 (p < 0.001). Pulmonary pressures and fractional shortening did not change significantly (p > 0.05). Four patients received an implantable cardioverter/defibrillator as a result of their pathologic electrophysiologic examination. CONCLUSIONS: In carefully selected patients, PLV combined with MVR achieves short-term results comparable to that after heart transplantation. However, long-term results and multicenter evaluation will be needed to define its place in the treatment of advanced heart failure.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVES: This prospective study tested whether Doppler echocardiographic variables add incremental value to QRS duration in determining the prognosis of patients with chronic heart failure (CHF) and systolic dysfunction. BACKGROUND: Diastolic dysfunction frequently is observed in patients with CHF, but its prognostic impact relative to that of QRS duration is unknown. METHODS: A total of 193 patients with CHF and an ejection fraction <45% were enrolled prospectively. Echo measurements included left ventricular dimensions/volumes, ejection fraction, mitral early/late diastolic velocity ratio, deceleration time, and tissue Doppler mitral annular velocities. The mitral filling pattern was classified as either restrictive (RFP) or nonrestrictive. A cardiac event (cardiac death or urgent cardiac transplantation) was defined as combined study end point. RESULTS: During a follow-up of 385 +/- 270 days, 24 patients suffered an event (cardiac death, n = 21; urgent transplantation, n = 3). The RFP, QRS duration, left ventricular systolic diameter, and mitral annular early diastolic velocity were independent predictors of an event. In patients with QRS duration >144 ms, the outcome was markedly poorer in the presence of RFPs as compared with their absence. Similarly, despite a QRS duration <or =144 ms, the outcome was worse in the presence of a RFP. A risk-stratification model based on the three strongest independent predictors separated groups into those with good prognosis and those with high, intermediate, and low event-free survival rates. CONCLUSIONS: In subjects with CHF and systolic dysfunction, transmitral flow patterns add incremental value to QRS duration in determining the prognosis.
BACKGROUND: Even today, infective endocarditis (IE) remains a severe and potentially fatal disease demanding sophisticated diagnostic strategies for detection of the causative microorganisms. Despite the use of appropriate laboratory techniques, classic microbiological diagnostics are characterized by a high rate of negative results. METHODS AND RESULTS: Broad-range polymerase chain reaction (PCR) targeting bacterial and fungal rDNA followed by direct sequencing was applied to excised heart valves (n=52) collected from 51 patients with suspected infectious endocarditis and from 16 patients without any signs of IE during an 18-month period. The sensitivity, specificity, and the positive and negative predictive values for the bacterial broad-range PCR were 41.2%, 100.0%, 100.0%, and 34.8%, respectively, compared with 7.8%, 93.7%, 80.0%, and 24.2% for culture and 11.8%, 100.0%, 100.0%, and 26.2% for Gram staining. Without exception, database analyses allowed identification up to the (sub)species level comprising streptococcal (n=13), staphylococcal (n=4), enterococcal (n=2), and other signature sequences such as Bartonella quintana and Nocardia paucivorans. Fungal ribosomal sequences were not amplified. All valve tissues of the reference group were negative for both PCR and conventional methods, except one sample that was contaminated by molds. CONCLUSIONS: Culture-independent molecular methods substantially improve the diagnostic outcome of microbiological examination of excised heart valves. Importantly, this was true not only for fastidious, slow-growing, and/or nonculturable microorganisms but also for easy-to-culture pathogens such as streptococci and staphylococci. Both patient management and empiric antibiotic therapy of IE are likely to benefit from improved knowledge of the spectrum of pathogens now causing IE.
BACKGROUND: The prognostic value of tissue Doppler imaging (TDI) in patients with chronic congestive heart failure (CHF) has not been compared against conventional measures of systolic, diastolic and overall left ventricular LV performance. The aim of this study was to assess the prognostic value of TDI-derived parameters in patients with CHF. METHODS: One hundred thirty-two subjects with chronic CHF [due to ischemic (n=82) or dilated (n=50) cardiomyopathy, 101 males, mean age 57+/-11 years] underwent conventional two-dimensional/Doppler echocardiography and assessment of the Tei-index (isovolumic contraction time and isovolumic relaxation time divided by ejection time). Systolic, early and late diastolic mitral annular velocities (S', E' and A') were derived from pulsed TDI. A cardiac event (cardiac death, urgent cardiac transplantation or hospitalization due to decompensated CHF) was defined as the combined study endpoint. RESULTS: The patients were followed for a mean of 224+/-123 days. Thirty-one patients suffered an event (cardiac death, n=5; urgent cardiac transplantation, n=2; hospitalization due to CHF, n=24). In patients with event, ejection fraction was lower (25+/-10 vs. 32+/-9%), mitral deceleration time was shorter (138+/-58 vs. 193+/-72 ms), and the peak mitral E/E'-ratio (16.1+/-6.6 vs. 10.6+/-5.0) was significantly elevated as compared to patients free of events (p<0.001 for all comparisons). In those patients, the Tei-index was elevated (1.09+/-0.39 vs. 0.86+/-0.26, p<0.01), and a restrictive mitral filling pattern was more frequent (51.6 vs. 17.5%, p<0.001). Stepwise multivariate analysis identified the mitral E/E'-ratio (p<0.001) and the Tei-index (p=0.019) as the only independent predictors of a combined event. E/E'-ratio was the best predictor of hospitalization due to CHF also. In patients with mitral E/E'-ratio>12.5 or Tei-index>0.90, outcome was poor. CONCLUSIONS: In subjects with chronic CHF, the mitral E/E'-ratio is a stronger predictor of future cardiac events than conventional parameters of systolic, diastolic or overall LV performance. The E/E'-ratio may be a useful addition in the routine follow-up of such patients.
We report on an unusual case of a young female patient who received an implantable LVAD after unsuccessful emergency coronary bypass surgery following acute myocardial infarction. After LVAD placement, it became evident that the patient had been pregnant. She had to undergo gynaecological surgery during mechanical support to remove the deceased fetus.
BACKGROUND: The Incor (Berlin Heart AG, Germany) is a small (200 g), implantable, magnetically accentuated axial flow pump (non-pulsatile flow) designed to support the left ventricle for extended periods of time. We report on the first single-center clinical experience with this device. METHODS: The Incor was studied in 15 consecutive patients (10 men, 5 women), 24 to 59 years of age. Underlying heart disease was end-stage ischemic heart disease (n = 5), acute myocardial infarction (n = 4), dilated cardiomyopathy (n = 3), acute myocarditis (n = 2) and Chagas disease (n = 1). All patients were in New York Heart Association (NYHA) Class IV heart failure. Four patients had prior open heart surgery. Implantation via cannulation of the left ventricular apex and the ascending aorta was elective in 6 patients and on an emergency basis in 9. RESULTS: No early bleeding complications were seen, but late bleeding occurred in 4 patients. Minor cerebral thromboembolic events with transient neurologic symptoms occurred in 3 patients; severe stroke had to be treated in 1 patient. Systemic emboli were seen in 2 patients. Thrombus-related pump dysfunction was suspected in 3 patients, and managed by intensifying anti-coagulation. Five patients were successfully transplanted after a support interval of 90 to 156 days; 1 patient could be weaned from the system after 171 days. Six patients died during support, 9 to 63 days after device implantation. The remaining 3 patients are still under support, with excellent quality of life. CONCLUSIONS: The Incor is a left ventricular assist device (LVAD) with transplant and adverse event rates comparable to those of other modern ventricular support devices. Its advantages include the small pump chamber, the virtual absence of device-related infections, and the extraordinary convenience during implantation and explantation.
OBJECTIVES: The purpose of this study was to evaluate retrospectively a single-center experience with the use of ICDs in patients with long QT syndrome (LQTS) concerning outcome, complications, and optimal programming. BACKGROUND: Use of implantable cardioverter-defibrillator (ICD) in patients with congenital LQTS is controversial but is generally accepted in high-risk patients. METHODS: We enrolled 27 symptomatic patients with LQTS undergoing ICD therapy (QTc 540 +/- 64 ms(1/2); 85% female, 63% cardiac arrest; 33% syncope despite beta-blockers; 4% with severe phenotype) and 81 genotyped patients with LQTS undergoing conventional drug therapy (28 LQT1, 39 LQT2, 1 LQT3, 13 LQT5). During a mean follow-up of 65 +/- 34 months, one death occurred in the ICD group that was not LQTS related. A total of 178 appropriate shocks were observed in 10/27 patients (37%), mostly in survivors of cardiac arrest (in 58% of cardiac arrest patients vs. in 20% of non-cardiac arrest patients). RESULTS: In a logistic regression analysis, only QTc interval (121/178 shocks (68%) for QTc > 500 ms(1/2)) and "survived cardiac arrest" were prognostic for ICD shocks. In 30% of patients in the ICD group, multiple shocks occurred and could be reduced after increase of antibradycardia pacing rate, adding beta-blocker therapy, or starting the rate-smoothing algorithm (average 7.1 shocks before to 0.75 shocks after additional intervention annually). CONCLUSION: ICD therapy is a safe and useful tool in high-risk patients with LQTS. QTc interval and cardiac arrest survivors were prognostic factors for appropriate ICD shocks. The results of this large single-center experience suggest that beta-blockers should always be added to ICD therapy. In addition, some patients might benefit from additional antibradycardia pacing, prolonged detection time, and a rate-smoothing algorithm to prevent recurrent episodes.
OBJECTIVE: Pulsatile left ventricular assist devices serving as mechanical circulatory support for patients with end-stage heart failure are associated with complications, including bleeding, thromboembolism, and infection. Axial-flow pumps might overcome some of these shortcomings. Here we report our experience with long-term application of the DeBakey VAD (MicroMed Technology, Inc, Houston, Tex). METHODS: Nine male transplant candidates (37 +/- 14 years) with severe hemodynamic compromise (cardiac index, 1.6 +/- 0.5 L . min(-1) x m(-2); pulmonary capillary wedge pressure, 27 +/- 6 mm Hg) and beginning end-organ failure despite inotropic and intra-aortic balloon pump support received the DeBakey VAD. Clinical outcome was evaluated. RESULTS: Cumulative support was 7.8 years, and the mean duration of support was 314 +/- 75 days (range, 229-438 days). Eight patients were transplanted, and one died from intracerebral bleeding. Peripheral circulation and end-organ function recovered rapidly after implantation. Continuous flow was able to maintain adequate organ perfusion over the long term. Eight patients were discharged during support, with good quality of life. There were no early bleedings, but there were late bleedings in 3 patients caused by excessive anticoagulation and platelet inhibition. Neurologic events occurred in 4 patients. Three patients recovered completely from symptoms, and one had lethal intracerebral bleeding. Because of thrombus formation, the device was exchanged in 4 patients. With increasing experience, thrombolysis was performed in similar situations. All such patients underwent successful transplantation. Hemolysis occurred, with events indicating thrombus formation. Device-related infection was found in one patient. CONCLUSIONS: The DeBakey VAD demonstrated its potential for long-term bridge to transplantation. The risk for thrombus formation needs to be addressed by improvement of pump technology and new strategies for platelet inhibition.
OBJECTIVE: Microembolic signals detected by transcranial Doppler ultrasonography have been demonstrated to be clinically relevant in patients supported with pulsatile left ventricular assist devices. We prospectively investigated the quantity of microembolic signals in patients supported with the continuous-flow DeBakey left ventricular assist device (MicroMed DeBakey VAD; MicroMed Technology, Inc, Houston, Tex) including the refined Carmeda BioActive Surface system (Carmeda AB, Stockholm, Sweden). METHODS: Twenty-three patients (20 male) aged 14 to 62 years supported with DeBakey left ventricular assist devices (n = 6 with Carmeda) were enrolled in this study. Microembolic signal monitorings were performed twice weekly by insonating the middle cerebral artery for 20 minutes without and 20 minutes with oronasal application of oxygen (6 L/min). Evidence of clinically manifest thromboembolic events was based on regular questionnaires, clinical examinations, and results of diagnostic procedures. RESULTS: Despite a low incidence of thromboembolic complications (0.24 per 100 left ventricular assist device days), 20 patients (87%) showed circulating microemboli. Overall, microembolic signals were found in 175 of 499 transcranial Doppler ultrasonographic examinations (35.1%), with mean counts of 81.2 +/- 443 (range 0-5042 signals/h). Both microembolic signal prevalence (25% vs 34%, P = .01) and absolute signal counts (46.5 vs 104, P < .01) significantly declined with oxygen delivery. There was no significant correlation between the individual microembolic signal activity and the incidence of clinical thromboembolism or the intensity of antihemostatic treatment. Patients supported with the Carmeda device did not show reduced rates of clinical thromboembolization or cerebral microemboli. CONCLUSION: In patients with DeBakey left ventricular assist devices, a high load of clinically silent microemboli can be detected within the cerebral arteries despite a low incidence of embolic complications. It needs to be investigated whether such continuous, presumably gaseous microembolization causes cognitive or neuropsychologic deficits.