Incidence of complications in patients with implantable cardioverter/defibrillator who receive additional transvenous pace/sense leads.

BACKGROUND: Implantation of an additional pace/sense (P/S) lead is commonly used in patients with implantable cardioverter/defibrillators (ICDs) to overcome P/S defects of integrated defibrillation leads (HV-P/S leads). No information is available about the clinical outcome and the incidence of complications in these patients. METHODS: Retrospective analysis was performed in 151 patients (125 male, age 54.9 +/- 13.6 years, LVEF 48.1 +/- 17.8%, CAD in 86 [57%], DCM in 24 [16%], ARVCM in 11 [7%]) who received an additional P/S lead between 1990 and 2002 (54 patients with abdominal and 97 patients with pectoral ICD system). Statistical analysis was done using Kaplan-Meier survival curves. RESULTS: The average follow-up (FU) after implantation of the additional P/S lead was 43 +/- 27 months. In total 117 patients [77.5%] remain implanted; 22 patients died due to cardiac-related reasons. After a FU of 23 +/- 23 months, 43 patients [28.5%] experienced lead-related problems after implantation of the additional P/S lead: oversensing in 23 [53.5%], insulation defect in 3 [7.0%], fracture in 1 [2.3%], system infection in 4 [9.3%], and defect of the HV-P/S lead in 6 [14.0%] patients. The event-free cumulative survival of the additional P/S lead after 1, 2, and 5 years was 87.0%, 79.8%, and 59.4%, respectively (for pectoral leads: 89.6%, 82.0%, and 60.0%, respectively). CONCLUSIONS: Implantation of an additional P/S lead in case of failure of an HV-P/S lead is safe. However, it is associated with a substantial rate of complications during FU. Therefore, extraction of damaged defibrillation leads instead of implantation of P/S leads should be favored.

Aged↗

Can Doppler time domain analysis of microembolic signals discriminate between gaseous and solid microemboli in patients with left ventricular assist device?

OBJECTIVE: Microembolic signals (MES) can be detected by transcranial Doppler sonography (TCD). To identify gaseous microemboli the inhalation of oxygen is an established method in patients with prosthetic heart valves. Time domain analysis of sample volume length (SVL) and of frequency modulation showed promising results in the discrimination between solid and gaseous microemboli. We investigated whether these time domain analyses allow the discrimination of different types of microemboli in patients with the non-pulsatile DeBakey left ventricular assist device (LVAD). MATERIALS AND METHODS: Repeated unilateral detection of MES was performed by TCD in 20 patients supported with DeBakey LVAD. Each monitoring session consisted of 20 minutes without and 20 minutes with inhalation of 100% oxygen (6 l/min). A total of 500 MES, detected with (n=250) or without (n=250) the supply of oxygen, were randomly chosen for offline analysis. The SVL (in cm) was calculated by duration and velocity of the MES measured in the time domain mode. Additionally, frequency modulation of MES was classified into three main types: Without modulation (type I), with gradual changes (type II) and with rapid changes (type III). RESULTS: With oxygen supply, both prevalence (26.4% versus 36.2%, p<0.01) and mean counts of MES per hour (49+/-293 versus 108+/-550, p<0.001) significantly declined compared with the MES load while breathing room air. There was no significant difference in the SVL of MES under oxygen (0.85+/-0.38 cm) compared with those without oxygen delivery (0.92+/-0.37 cm, p=0.6). Furthermore, no significant differences were noted for the MES frequency modulation types in time domain analysis with regard to oxygen supply. CONCLUSIONS: The reduction of MES under oxygen delivery confirms the gaseous nature in a substantial number of circulating microemboli produced by the DeBakey LVAD. However, SVL and frequency modulation of MES did not appear to provide valuable information regarding the structural nature of the underlying microembolic material.

Brain↗

Implantable cardioverter/defibrillator therapy in arrhythmogenic right ventricular cardiomyopathy: single-center experience of long-term follow-up and complications in 60 patients.

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a major cause of ventricular tachycardia (VT) and cardiac arrest in young patients. We hypothesized that treatment with implantable cardioverter/defibrillators (ICDs) is safe and improves the long-term prognosis of ARVC patients at high risk of sudden death. METHODS AND RESULTS: Sixty patients with ARVC (aged 43+/-16 years) were treated with transvenous ICD systems. Despite a higher number of right ventricular sites tested for adequate lead positions (P<0.05), lower R-wave amplitudes (P<0.001) were achieved in ARVC patients compared with other entities. During follow-up of 80+/-43 months (396 patient-years), event-free survival was 49%, 30%, 26%, and 26% for appropriate ICD therapies and 79%, 64%, 59%, and 56% for potentially fatal VT (>240 bpm) after 1, 3, 5, and 7 years, respectively. Multivariate analysis identified extensive right ventricular dysfunction as an independent predictor of appropriate ICD discharge. Fifty-three adverse events occurred in 37 patients during the perioperative (n=10) or follow-up (n=43) period, mainly related to the leads (n=31 in 21 patients). No lead perforation was observed. Freedom from adverse events was 90%, 78%, 56%, and 42% and freedom from lead-related complications was 95%, 85%, 74%, and 63% after 1, 3, 5, and 7 years, respectively. CONCLUSIONS: These results strongly suggest an improvement in long-term prognosis by ICD therapy in high-risk patients with ARVC. However, meticulous placement and long-term observation of transvenous lead performance with focus on sensing function are required for the prevention and/or early recognition of disease progression and lead-related morbidity during long-term follow-up of ICD therapy in ARVC.

Adolescent↗

Direct epicardial mapping predicts the recovery of left ventricular dysfunction in chronic ischaemic myocardium.

AIMS: This study investigated the hypothesis that direct epicardial bipolar mapping is able to predict the recovery of left ventricular (LV) dysfunction in ischaemic myocardium. METHODS AND RESULTS: In 34 patients with CAD, a maximum of 102 bipolar epicardial electrograms per patient (n=3468 electrograms) were simultaneously recorded with a ventricular jacket array intraoperatively immediately prior to revascularization. Only LV electrograms with good myocardial contact (n=1813, 52+/-14 per patient, mean+/-SD) were analyzed. In accordance to the position of each electrode, segmental myocardial function was assessed by transthoracic echocardiography before and 7+/-2 months (mean+/-SD; range 3-10 months) after CABG using a wall motion score. Preoperatively dysfunctional segments (n=700) were classified as viable (improvement in wall motion score of at least 20% following CABG, n=424) or non-viable (no improvement, n=276). Bipolar voltage was significantly lower in non-viable when compared to viable myocardium (P<0.001, ANOVA) At a cut-off value of 5.9mV, ROC-curve analysis for bipolar voltage (to discriminate between viable and non-viable myocardium) revealed a sensitivity of 83% at a specificity of 83% (area under the ROC-curve of 0.92+/-0.01, mean+/-SE). CONCLUSIONS: Direct epicardial mapping is able to predict the recovery of chronically ischaemic dysfunctional myocardium and thereby proves the presence of myocardial viability.

Analysis of Variance↗

Amniotic air insufflation during minimally invasive fetoscopic fetal cardiac interventions is safe for the fetal brain in sheep.

BACKGROUND: Amniotic air insufflation during experimental fetoscopic fetal cardiac interventions greatly improves the visualization of intra-amniotic contents. The purpose of this study was to assess any histologically discernible effects from this approach on the fetal brain after short-term studies and long-term survival in sheep. METHODS: Thirty pregnant ewes between 80 and 110 days of gestation underwent amniotic air insufflation during various fetoscopic fetal cardiac interventions. After 18 short-term and 12 long-term studies, the brains of the operated fetuses and-if available-their unoperated siblings were examined for hemorrhage, embolism, infarctions, inflammatory changes, and abnormal cortical maturation. RESULTS: Amniotic air insufflation during minimally invasive fetoscopic fetal cardiac interventions did not result in any histologically discernible damage to the brain in short-term and long-term studies in any but 2 sibling sheep. In the 2 affected siblings, a small area of chronic cortical frontal lobe infarction was observed after long-term survival. CONCLUSIONS: Amniotic air insufflation during minimally invasive percutaneous fetoscopic fetal cardiac interventions is safe for the fetal brain and does not compromise maternal hemodynamics in sheep. These findings encourage further investigation of the role this technique might play during fetoscopic fetal cardiac interventions in humans.

Amnion↗

Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support.

BACKGROUND: Nonpulsatile axial or centrifugal pumps are the latest generation of left ventricular assist devices (LVAD). Whether left ventricular (LV) unloading and outcome in these devices is similar to pulsatile LVADs during long-term support has not been investigated. We compared LV unloading and mortality between different types of LVAD support (pulsatile versus nonpulsatile). METHODS: In 31 patients undergoing long-term LVAD implantation (nonpulsatile = 10, pulsatile = 21) preoperative and postoperative echocardiographic and hemodynamic assessment with right heart catheterization had been obtained. RESULTS: All patients had similar echocardiographic, hemodynamic, and clinical heart failure characteristics at baseline. The degree of LV pressure unloading was the same in both device types, caused by similar reduction of mean pulmonary pressure (18.6 +/- 5.1 versus 18.3 +/- 7.5 mm Hg) and pulmonary capillary wedge pressure (8.9 +/- 4.4 versus 8.0 +/- 7.0 mm Hg). Left ventricular volume unloading was pronounced with a pulsatile device owing to a statistically significant higher pump output (5.1 +/- 1.0 L/min) in comparison with nonpulsatile LVADs (3.6 +/- 0.9 L/min, p < 0.001). Echocardiographic-determined end-systolic indicators confirm this augmentation in pulsatile LVADs. Etiology or the time interval of hemodynamic reassessment had no impact in left ventricular pressure unloading, but LV volume unloading decreased between day 60 and 120 in patients with nonpulsatile LVADs. The preoperative and postoperative transplant mortality was comparable in both groups. CONCLUSIONS: Left ventricular pressure unloading is similar in patients with nonpulsatile as compared with pulsatile implantable long-term assist devices. Left ventricular volume unloading is pronounced in pulsatile LVADs.

Adolescent↗

Skeletonization versus pedicle preparation of the radial artery with and without the ultrasonic scalpel.

BACKGROUND: The radial artery (RA) is increasingly used for myocardial revascularization because of its presumed advantageous long-term patency rates. The vessel can be harvested as a pedicle or skeletonized. The aim of this study was to compare the skeletonization technique with pedicle preparation using either an ultrasonic scalpel or scissors. METHODS: Forty consecutive patients with coronary artery disease undergoing complete arterial revascularization were included in the study. In 20 patients the RAs were prepared using scissors and clips (group 1: skeletonization; group 2: pedicle). In another 20 patients the arteries harvested were prepared using an ultrasonic scalpel (group 3: skeletonization; group 4: pedicle). The RA was treated with papaverine to prevent spasm of the vessel during and after harvesting. Tissue specimens of each RA were taken to analyze endothelial morphology by scanning electron microscopy. After implantation of the RA, graft perfusion was measured with a flow probe. RESULTS: Harvesting the RA as a skeletonized vessel took more time as compared with pedicle preparation (group 1 vs group 2: 37.1 +/- 3.5 minutes vs 24.4 +/- 3.9 minutes; p < 0.001 and group 3 vs group 4: 31.1 +/- 3.5 minutes vs 25.6 +/- 3.7 minutes; p < 0.01). The number of hemostatic titanium clips was similarly higher in group 1 as opposed to group 2 (58.7 +/- 7.1 vs 38.7 +/- 7.1; p < 0.01). However, there was no difference between groups 3 and 4 (p = 0.086). The length of the RA after skeletonization with scissors and clips was 20.8 +/- 1.5 cm in contrast with 19.1 +/- 0.9 cm (p < 0.01) after dissection as a pedicle. In the groups using the ultrasonic scalpel, there was no difference in graft length (p = 0.062). Mean blood flow through the graft after establishing the proximal anastomosis was similar among all groups (groups 1, 2, 3, and 4: 50 +/- 20.1 mL/min, 53.8 +/- 24.3 mL/min, 56.3 +/- 25.1 mL/min, and 51.8 +/- 23 mL/min, respectively). Scanning electron microscopy demonstrated endothelial damage in all patients in groups 1, 2, and 3 and in 7 patients of group 4. Most endothelial lesions were minor except in group 3 in which 1 of 5 endothelial lesions were severe. Statistically significant differences was found between groups 1 and 2, and 3 and 4 with respect to the degree of endothelial damage (p < 0.01). CONCLUSIONS: Skeletonization using scissors and clips is more time consuming and technically more difficult, but yield significantly longer grafts. Skeletonization with an ultrasonic scalpel did not result in additional length and was more frequently associated with severe endothelial damage. Pedicle preparation using scissors or an ultrasonic scalpel is much simpler and faster, and does not jeopardize endothelial integrity.

Humans↗

Vasoactive peptides during long-term follow-up of patients after cardiac transplantation.

BACKGROUND: Vasoactive peptides are accepted indicators of the degree of heart failure and its progression or improvement following medical therapy. Normalization of cardiac hemodynamics by cardiac transplantation (HTx) may lead to normalization of atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) plasma levels shortly after the procedure. METHODS: Long-term follow-up was done for 14 consecutive patients, 12 men and 2 women, 49 years of age (range 24 to 64 years). ANP and BNP were measured by radioimmunoassay (RIA) in central venous plasma samples (before breakfast, at steady state) at the following intervals after HTx: 7 to 30 (1), 31 to 60 (2), 61 to 90 (3), 120 to 180 (4) and 210 to 365 (5) days. RESULTS: During follow-up, ANP decreased significantly within 2 months after HTx and continued of this level, whereas BNP decreased continuously without reaching normal values. The mean ratio of ANP:BNP increased from 3.23 to 8.01 during follow-up. Whereas right atrial pressure (RAP), right ventricular pressure (RVP), right ventricular end-diastolic pressure (RVEDP) and pulmonary capillary wedge pressure (PCWP) did not change during follow-up, cardiac output (CO) improved slightly, but significantly from 5.21 liters/min to 5.9 liters/min (p = 0.035). CONCLUSIONS: Normalization of left ventricular function after orthotopic HTx does not induce an early diminution of ANP and BNP plasma levels to normal concentrations. Although elevated ANP concentrations showed only minimal changes within 1 year, BNP decreased significantly as early as 2 months after HTx, without reaching normal values during the year of follow-up. Also, the ratio of ANP and BNP increased significantly from 3.23 to 8.01. These results demonstrate the contribution of other factors beyond cardiac function that determine the levels of these peptides.

Atrial Natriuretic Factor↗

Analysis of platelet function during left ventricular support with the Incor and Excor system.

Improvements in pump technology and the scarcity of donor organs have led to an increased use of mechanical assist devices, but the problem of thromboembolism has still not been solved. We report on our initial experience with sequentially analyzing platelet function in patients provided with the Incor left ventricular assist device (LVAD) and the Excor LVAD system. Thirteen patients 5 to 61 years old with acute or end-stage heart failure were included in a pilot study. Five of the 10 Incor patients underwent LVAD placement under emergency conditions, and 5 were electively scheduled for surgery. All 3 patients with an Excor device had been connected to an extracorporeal membrane oxygenation system prior to insertion of the device. An anticoagulation protocol including heparin, aspirin, and clopidogrel was employed, and the patients were closely monitored with a special platelet analyzing system that allows dose optimization for antiplatelet drugs. Initial platelet function was normal in only 2 patients (15%). During a follow-up period of 1770 days (cumulative >4.8 years), no early (<30 days) bleeding complications related to device implantation occurred. Late cerebral thromboembolic events were noted in 3 patients. One patient experienced severe stroke mandating neurosurgery during mechanical assist, and 1 patient experienced systemic embolism. The PAP platelet analyzer offers a cheap and reliable alternative to the more expensive thromboelastography method for adequately surveying the efficacy of aspirin and clopidogrel treatment, even if late thromboembolic events cannot be prevented.

Adolescent↗

Functional changes after partial left ventriculectomy and mitral valve repair assessed by gated perfusion SPECT.

UNLABELLED: A myocardial remodeling in dilated cardiomyopathy (DCM) after partial left ventriculectomy (PLV) has been previously discussed. The aim of this study was to investigate the functional changes in the follow-up of patients with DCM undergoing PLV using electrocardiographically triggered perfusion SPECT (gated SPECT). METHODS: Twelve DCM patients (10 men, 2 women; 56 +/- 9 y [mean +/- SD]), after successful PLV and mitral valve repair (PLV-MVR), were monitored by gated SPECT and echocardiography. Gated SPECT quantified end-diastolic volumes (EDV), end-systolic volumes (ESV), myocardial and scar volumes, as well as ejection fraction (EF) preoperatively, early (38 +/- 28 d), and late (296 +/- 130 d) after PLV-MVR. RESULTS: EDV and ESV showed an immediate reduction after PLV-MVR (EDV from 542 +/- 90 mL to 350 +/- 81 mL, P < 0.001; ESV from 452 +/- 91 mL to 254 +/- 79 mL, P < 0.001) with no significant change in the late follow-up (EDV late, 316 +/- 63 mL; ESV late, 207 +/- 63 mL; both P = not significant vs. early follow-up). PLV-MVR immediately improved EF (preoperative, 16.8% +/- 5.5%; early, 28.8% +/- 7.6%; P = 0.003) with no significant change in the late follow-up (36.0% +/- 9.4%; P = not significant vs. early follow-up). CONCLUSION: In this highly selected DCM patient group, gated perfusion SPECT assessed early responses in volumes and EF after PLV-MVR. However, although statistically nonsignificant in the small patient group, ESV and EDV were further decreased, whereas EF improved toward 1 y, coinciding with the improvement of clinical symptoms (New York Heart Association), potentially indicating a functional remodeling after PLV-MVR. Further studies in larger patient cohorts and longer follow-up are warranted.

Adult↗

The heart-allocation simulation model: a tool for comparison of transplantation allocation policies.

BACKGROUND: Numerous studies have investigated prognostic factors for the survival of transplant candidates waiting for a donor organ, but little is known about the impact of allocation policies on waiting list outcome. Simulation models would allow a comparison of different policies for allocating donor hearts on pretransplant outcome. METHODS: A model was built for the Eurotransplant waiting list for heart transplantation. Survival and delisting distributions were estimated from the Eurotransplant transplant candidate inflow between 1995 and 2000 (n=7,142). Other characteristics were obtained directly from the transplant candidate inflow of 1999 and 2000 (n=2,097) and the donor organs of 1998 and 1999 (n=1,520). Overall and subgroup waiting list mortality were estimated for allocation policies differing by ABO blood group, border, and clinical profile rules. RESULTS: The model estimated that international organ exchange reduces waiting list mortality in the different countries by 1.9% to 12.4%. An allocation policy incorporating the initial clinical profile of the transplant candidates further reduced waiting list mortality by 1.7%. Changing ABO rules toward identical matching yielded a slightly more equitable survival for the different groups, without an overall effect on mortality. The best possible allocation policy is the policy where organs are allocated to patients that are at highest risk of dying, and withholding organs from patients that would eventually delist because of improvement. CONCLUSIONS: Patients benefit from international organ exchange and by a heart allocation scheme based on clinical profiles. Timely delisting of patients who are-temporarily-too well for transplantation is the best waiting list policy.

Computer Simulation↗

A prognostic model for predicting waiting-list mortality for a total national cohort of adult heart-transplant candidates.

BACKGROUND: Current trends in medical management of advanced heart failure and transplant medicine and the enactment of a national transplant law forced a change toward allocation driven by disease severity. OBJECTIVE: The aim of this study was to create a model for predicting waiting-list survival on the basis of simple clinical parameters. METHODS: The clinical profiles of all patients registered for heart transplantation in Germany in 1997 (n=889) were used as a derivation set, and the total German 1998 cohort (n=897) was used as a validation set. The model was validated by the c statistic and by comparison of risk stratified mortality rates. The validated model was fine tuned by the appropriate calibration procedures. The data were first classified into physiologic subscores: an urgency score, a left ventricular heart failure score, a right ventricular heart failure score, and a systemic heart failure score. A stepwise modeling procedure was undertaken using these subscores as factors as well as the recipient's age, ABO blood group, and body surface area. RESULTS: The urgency and the left ventricular subscore were found to be significantly associated with waiting-list mortality. A summary index termed German Transplant Society (GTS) score was then calculated on the basis of seven parameters contained in these two subscores. The GTS score was able to predict waiting-list mortality risks for the 1998 cohort: 1-year mortality before transplantation was 71%, 34%, 11% for the high, medium, and low risk groups, respectively. CONCLUSION: The use of this continuous disease severity index may improve the selection of cardiac transplant candidates.

Adult↗

Dynamic regulation of MEK/Erks and Akt/GSK-3beta in human end-stage heart failure after left ventricular mechanical support: myocardial mechanotransduction-sensitivity as a possible molecular mechanism.

OBJECTIVE: Left ventricular assist devices (LVAD) are used to 'bridge' patients with end-stage heart failure to transplantation. After long-term LVAD support, ventricular function may partially recover, a process called 'reverse remodeling'. As several kinase-mediated signal transduction pathways have been implicated in the development of cardiac hypertrophy and failure, we examined the activities of the Erks, MEKs, Akt, GSK-3 beta, p70S6K, JNKs and p38 under LVAD support as well as during single myocyte strain and whole heart stretch. METHODS: Western blotting and immunohistochemistry were performed using phospho-specific antibodies in matched samples from ten patients with end-stage heart failure before and after LVAD. Cyclic strain was performed in rat neonatal cardiac myocytes, and tensile stretch applied to Langendorff-perfused mouse hearts via a left ventricular balloon. RESULTS: The activity of Erks and Akt in failing hearts dramatically decreased after LVAD support, while that of GSK-3 beta increased. There was an endo/epicardial gradient for Erk activity which persisted after LVAD despite the reduction of total Erk activity. TUNEL-positivity and myocyte size decreased after LVAD, but independently of changes in kinase activity. In cardiomyocytes and Langendorff-perfused mouse hearts both strain/stretch and its relief regulated the activities of Erks, Akt, and GSK-3 beta. CONCLUSION: Erks and Akt/GSK-3 beta are highly responsive to myocyte stretch in vitro and in vivo, and may be sensitive molecular parameters of 'reverse remodeling' under LVAD support.

Adolescent↗

Spontaneous splenic rupture after a left-side thoracotomy: report of a case.

We herein describe the case of a 59-year-old man who experienced a spontaneous splenic rupture 12 h after undergoing a left-side thoracotomy for a wedge resection of an unknown pulmonary nodular tumor following a history of malignant melanoma. He demonstrated no special abdominal diseases or traumas, except an uneventful cholecystectomy 12 years previously. Preoperatively, he was not on anticoagulation, aspirin, or nonsteroidal anti-inflammatory medication, and all coagulation tests were inconspicuous. At 12 h after lung surgery the patient showed signs of progredient hypovolemic shock. After ultrasonography, which showed a moderate amount of free intra-abdominal liquid, the patient was urgently taken to the operation room. Bleeding resulted from a rupture of an encapsulated hematoma from the spleen. No signs of adhesion around the spleen or of an injury of the left diaphragm were observed. A pathological analysis of the spleen revealed a normal dimension and a normal histological structure without any evidence of a hematological or neoplastic disease. The patient was discharged on the 12th day after surgery. A review on the literature and the differential diagnosis of this unusual case is presented and discussed.

Diagnosis, Differential↗

Resolved hypersensitivity myocarditis after ventricular circulatory assist.

Hypersensitivity myocarditis is known to be a cardiac manifestation of a delayed-type hypersensitivity response caused by drug treatment. In heart transplantation candidates the incidence is elevated. We report the case of a patient with end-stage heart failure who underwent implantation of a left ventricular assist device as a bridge to transplantation. The histologic investigation of the left ventricular specimen obtained during device implantation revealed the diagnosis of a hypersensitivity myocarditis. Ten months later this lesion showed complete reversibility within specimens of the explanted heart, maybe as a result of the termination of inotropic therapy after implantation of the left ventricular assist device.

Cardiomyopathy, Dilated↗

Doppler microembolic load predicts risk of thromboembolic complications in Novacor patients.

OBJECTIVE: Left ventricular assist devices have become an established method to bridge patients with end-stage cardiac failure to heart transplantation. Besides infection and bleeding, thromboembolism represents one of the most serious complications. We evaluated the value of microembolic signals in predicting thromboembolic events for individual patients and distinctive left ventricular assist device periods. METHODS: Twenty patients (14 male) aged 23-57 years supported with the Novacor N100 left ventricular assist device were enrolled in this study. All patients were on effective anticoagulation, 12 patients additionally received antiplatelet therapy. Unilateral detection of microembolic signals was performed once weekly by insonation of the middle cerebral artery using transcranial Doppler sonography for 30 minutes duration. Evidence of clinically manifest thromboembolic events was based on regular questionnaires, clinical examinations, and results of diagnostic procedures. RESULTS: During a cumulative follow-up of 3876 left ventricular assist device days, 44 thromboembolic complications occurred (incidence, 1.1%) in 15 out of 20 patients. A total of 360 transcranial Doppler sonography monitorings (range, 5-34 per patient) were performed with an overall microembolic signals prevalence of 35.3% and a microembolic signal mean of 2.3 +/- 9.2 per examination. There was a highly significant correlation between the individual microembolic signal activity and the respective incidence of clinical thromboembolism (r = 0.61-0.9; P <.01). Patients with additional antiplatelet treatment had significantly less thromboembolic complications (0.7%) and lower microembolic signal prevalence (18.3%) than those without (2.8% and 65.4%, respectively). Individual patients and left ventricular assist device months with clinical thromboembolization could be identified using the microembolic signal activity with moderate positive (0.37-0.7) and high negative predictive values (0.82-1.0). CONCLUSIONS: The amount of microembolic signals, serially detected in patients with the Novacor left ventricular assist device, is significantly associated with their incidence of embolic complications. The high negative predictive value of microembolic signals enables to identify those patients and left ventricular assist device periods with particularly low risk of clinical thromboembolization.

Adult↗

Partial left ventriculectomy in modified adriamycin-induced cardiomyopathy in the dog.

BACKGROUND: The purpose of this study was to evaluate modified adriamycin-induced cardiomyopathy in the dog for research on partial left ventriculectomy (PLV). METHODS: An intracoronary catheter was introduced into the left main stem via the first marginal branch in a retrograde fashion in 12 adult foxhound dogs. The catheter was connected to a percutaneous access port that was used for weekly adriamycin administration (10 mg over a 1-hour period on 5 occasions). Follow-up examinations (transthoracic echocardiography, hemodynamic parameters, cardiopulmonary status, neurohormones) were done before, 1 week after the last adriamycin administration, and then 6 weeks later. This protocol was performed in 6 dogs (control group: Group 1). The other 6 dogs underwent PLV 1 week after the last adriamycin administration (Group 2). After the last measurements, all dogs were killed with saturated potassium chloride under general anesthesia and the hearts were excised for histologic examination. All data were calculated as mean and standard error of the mean. Differences were calculated by the Wilcoxon signed-rank test for paired and unpaired data. p < 0.05 was considered statistically significant. RESULTS: One dog from each group died suddenly during adriamycin administration (probably due to ventricular arrhythmia). In addition, 1 dog from Group 2 suffered from a severe systemic inflammatory response syndrome after PLV and died 36 hours after surgery. Thus, 5 dogs from Group 1 and 4 from Group 2 underwent the entire study protocol. Adriamycin administration resulted in a severe dilated cardiomyopathy that was comparable in both groups (significant increase of central venous pressure, mean pulmonary artery pressure, pulmonary wedge pressure, left ventricular end-systolic and end-diastolic diameters, oxygen extraction, troponin I and anti-diuretic hormone, whereas cardiac output, ejection fraction and venous oxygen saturation decreased significantly). Deterioration of cardiac function continued after termination of adriamycin administration in Group 1 dogs, albeit not as progressively as during adriamycin administration. In contrast, cardiac function improved in Group 2 dogs after PLV, but did not reach baseline values. Cardiac index increased and oxygen extraction (p = 0.03) decreased, resulting in an enhanced venous oxygen saturation (p = 0.02). In particular, the distance of the papillary muscles at end diastole (p = 0.02) and at end systole (p = 0.02) at the mid-papillary level decreased significantly after PLV, resulting in reduced left ventricular diameter and volume (statistically significant for left ventricular end-systolic diameter and volume). All hearts had severe histologic alterations characteristic of adriamycin-induced toxicity, including cytoplasmic vacuolation, myocyte degeneration and increased fibrosis. CONCLUSION: Modified adriamycin-induced cardiomyopathy in the dog may be suitable for research on PLV.

Animals↗