On the design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities.

Recently, a new imaging technology has become available that allows the evaluation of tissue perfusion using echo-contrast agents in real-time imaging: power pulse inversion imaging (PPI). Although numerous in vitro phantoms have been designed for different imaging modalities in ultrasound (US), there is a need for a phantom that mimics microcirculation and allows, in particular, the assessment of contrast replenishment kinetics following US-induced destruction of microbubbles using the new method. We, therefore, designed a new capillary flow phantom that takes the requirements of the new US imaging techniques and the physical properties of microbubbles into account and serves flow velocities in the range of microcirculation (1 to 10 mm/s). PPI studies were performed in the newly designed phantom. The contrast agent used was AF0150. We studied homogeneity of contrast distribution within the capillary phantom, constancy of contrast infusion, the dose-effect relationship and, finally, the feasibility of flow assessment using the method of contrast replenishment following US-induced microbubble destruction in a flow velocity range of 2.1 to 9.45 mm/s. Analysis of the replenishment kinetics was performed using the mathematical model f(t) = A(1 - e(-beta t)), with A representing the blood volume and beta the microbubble velocity. The new capillary phantom allowed homogeneous contrast opacification within the perfused capillaries independently of the flow. Constancy of signal intensity was achieved over a time period of almost 2 h, indicating constant contrast delivery. A strong linear correlation between the PPI signal and the contrast dose was found (r = 0.998). Analysis of the replenishment parameters revealed a strong linear relationship between parameter beta and flow (r = 0.994) as well as A * beta and flow (r = 0.984) in the observed flow range. The newly designed perfusion phantom for the evaluation of echo-contrast replenishment kinetics fulfills, at very low flow velocities, important prerequisites such as constancy of contrast delivery, homogeneity of contrast signals, linear dose-effect relation and minimal attenuation. Thus, the new phantom allows standardized analysis of contrast replenishment kinetics using real-time perfusion imaging techniques at flow velocities comparable to those of the microcirculation.

Blood Flow Velocity↗

Determinants of myocardial hypoperfusion analyzed for the interventricular septum using power Doppler harmonic imaging with contrast echocardiography in humans: a methodologic approach for clinical practice.

BACKGROUND: To evaluate determinants of myocardial hypoperfusion using power Doppler harmonic imaging (PDHI) with myocardial contrast echocardiography (MCE) in clinical practice, a retrospective clinical study was performed comparing echocardiographic and angiographic data. Angiographic data of patients with a normal coronary angiogram (non-CAD) and symptomatic patients with low flow conditions caused by a stenosis of the left anterior descending coronary artery (LAD) or occlusion, or TIMI-II-flow in the LAD were compared with the PDHI data. METHODS AND RESULTS: In 32 patients, MCE was performed with a System Five Performance ultrasound system (GE Vingmed Ultrasound, Horten, Norway). Myocardial perfusion was semiquantitatively analyzed with the EchoPac 6.2b.134 software, bolus injection with Optison (0.35 mL with 5 mL saline flush), and continuous infusion with Levovist (400 mg/mL(-1); 3.5-5 mL/min(-1)) were performed (8 non-CAD patients, 8 CAD patients, respectively). After bolus injection, Doppler intensity (DI) kinetics showed a significant decrease of maximum DI wash-in rate (eg, apical septum [AS]: 4.9 +/- 3.3 vs 2.4 +/- 1.9 dB/s(-1)), of peak maximum DI (eg, AS: 25.3 +/- 6.3 vs 16.4 +/- 5.7 dB), and of DI determined 10 and 20 seconds after peak maximum DI (eg, AS: 22.1 +/- 4.9 vs 10.8 +/- 4.6 dB; AS: 20.4 +/- 5.3 vs 8.0 +/- 3.8 dB, respectively) using a trigger interval once every 3 cardiac cycles when normal perfused areas were compared with hypoperfused areas. During infusion coronary transit time (3.3 +/- 0.9 vs 7.0 +/- 3.6 seconds), maximum DI wash-in rate (eg, AS: 3.2 +/- 1.3 vs 1.3 +/- 0.8 dB/s(-1)) and DI-maximum plateau (eg, AS: 28.6 +/- 4.7 vs 18.3 +/- 6.4 dB) significantly decreased, respectively. CONCLUSION: Regional myocardial hypoperfusion at rest can be detected by using PDHI with MCE in clinical practice, according to a standardized methodologic protocol.

Albumins↗

Real-Time Contrast Echo Assessment of Myocardial Perfusion at Low Emission Power: First Experimental and Clinical Results Using Power Pulse Inversion Imaging.

Power pulse inversion (PPI) has been developed for echocontrast specific imaging in order to reduce destruction of microbubbles. The purpose of this study was to evaluate PPI for real-time contrast echocardiography. Therefore, in vitro studies in a physiological flow-phantom and clinical examinations in patients with coronary artery disease were performed. The in vitro rersults of this study indicate that PPI allows real-time imaging at low emission power and is almost nondestructive to contrast microbubbles of Definity. At this low emission power a strong linear relationship between the dosage of the contrast agent and the resulting PPI signal intensity was found (R = 0.998, p < 0.001). In the clinical examinations real-time imaging using low mechanical index PPI resulted in strong myocardial signals and a complete filling of the cavities indicating absence of bubble destruction. Most striking was the ability of PPI to display myocardial thickening and wall motion simultaneously with the assessment of myocardial contrast replenishment following ultrasound induced bubble destruction by high power frames. We conclude that PPI allows nondestructive contrast imaging both in experimental and clinical settings. Therefore, real-time imaging of myocardial perfusion and real-time assessment of contrast replenishment following ultrasound induced destruction of microbubbles is feasible. Moreover, PPI allows simultaneous assessment of perfusion and myocardial function.

Journal Article↗

Right Atrial Thrombi and Depressed Right Atrial Appendage Function After Cardioversion of Atrial Fibrillation.

BACKGROUND: It has been shown that cardioversion of atrial fibrillation may result in left atrial chamber and appendage dysfunction and cause new thrombi in the left atrium. The aim of this prospective study was to investigate right atrial appendage function and assess the incidence of new right atrial thrombi after electrical cardioversion. METHODS: Transthoracic echocardiography was performed in 25 patients 4 h before and at 24 h and 7 days after electrical cardioversion to determine right and left atrial mechanical function (internal atrial defibrillation, n = 16; external electrical cardioversion, n = 9), as assessed by peak A wave velocities derived from the transtricuspid and transmitral velocity profiles. In addition, transesophageal echocardiography was performed 4 h before and 24 h after cardioversion to evaluate postcardioversion thrombus formation in the right and left atrial chambers and to assess right and left atrial appendage function. The degree of spontaneous echo contrast was noted, and peak emptying velocities of the appendages were measured before and after cardioversion. RESULTS: Peak emptying velocities of both the right atrial appendage (mean +/- SD, 0.23 +/- 0.1 vs 0.32 +/- 0.11 m/sec; P = 0.02) and the left atrial appendage (0.3 +/- 0.15 vs 0.4 +/- 0.15 m/sec; P = 0.01) were significantly lower 24 h after cardioversion compared with 4 h before cardioversion, respectively. The degree of spontaneous echo contrast increased in the left atrium after cardioversion from 1.0 +/- 1.2 to 1.9 +/- 2.1 (P = 0.02), and in the right atrium, it increased from 0.8 +/- 1.1 to 1.2 +/- 1.1 (P = 0.1) after cardioversion. Peak A wave transtricuspid velocity increased from 0.26 +/- 0.05 m/sec at 24 h to 0.38 +/- 0.06 m/sec (P = 0.001) after 7 days; respective values for transmitral peak A wave velocity were 0.39 +/- 0.15 and 0.54 +/- 0.16 m/sec (P = 0.009). No thrombi were found in either the right or left atrium before cardioversion. In two patients, new thrombi in the right atrium were detected 24 h after internal atrial defibrillation. Thrombi were located at the superior rim of the fossa ovalis in both patients with patent foramen ovale. Another patient had developed a thrombus in the left atrial appendage. CONCLUSIONS: Electrical cardioversion may not only cause left atrial chamber and appendage dysfunction and left atrial thrombi but also lead to depressed right atrial appendage function and the generation of new thrombi in the body of the right atrium.

Journal Article↗

Improvement in Endocardial Border Delineation Using Tissue Harmonic Imaging.

BACKGROUND AND METHODS: For years, tissue has been assumed to be a linear medium in diagnostic ultrasound applications; thus, no backscattered signals in the second harmonic band are expected in harmonic imaging without the injection of a contrast agent. However, it has been shown that a useful tissue image is formed even without a contrast agent. The aim of this study was to evaluate whether this tissue harmonic image provided improved visualization of endocardial borders. Fifty-six adult patients with various heart diseases were investigated using conventional two-dimensional echocardiography and tissue harmonic imaging. In 30 of these patients, the left ventricular endocardial borders were well defined in the standard parasternal and apical views using conventional two-dimensional echocardiography. In the remaining 26 patients, delineation of endocardial borders was not possible in at least two segments. The equipment used was an ATL HDI-3000 diagnostic system equipped with harmonic imaging. RESULTS: In all 56 patients, the myocardium and valves could be imaged with tissue harmonic imaging. Harmonic recordings were sharper and contained fewer clutter artifacts than conventional recordings. Most striking was the enhancement of left ventricular endocardial borders. In the 26 patients with incomplete delineation of left ventricular endocardial borders, wall motion could be evaluated in 290 of 312 (93%) segments with tissue harmonic imaging compared with only 168 of 312 (54%) segments with conventional echocardiography (P < 0.001). CONCLUSIONS: Tissue harmonic imaging improves image quality and can be used to enhance the definition of left ventricular endocardial borders. These findings can be explained by the nonlinear propagation of ultrasound within the tissue, which results in distortion of the transmitted signal and, thus, harmonic generation.

Journal Article↗

Stimulated Acoustic Emission Nonbackscatter Contrast Effect of Microbubbles Seen with Harmonic Power Doppler Imaging.

Transient imaging has been introduced to enhance the signal intensities when using echo contrast agents. However, this phenomenon is not clearly understood. To evaluate the mechanisms of this phenomenon, isolated pig hearts were investigated with different echo imaging techniques in the beating, working heart as well as in an asystolic state without any motion of the heart. The hearts of five German farm pigs (21 +/- 2.5 kg) were surgically explanted and inserted in an artificial circulation providing physiological flow and pressures. Levovist in the dosage of 0.05-0.3 g was injected into the left atrium and contrast effects evaluated in the left ventricular (LV) cavity and in the myocardium with an ultrasound imager (ATL, HDI 3000) equipped with a prototype software for harmonic imaging. Harmonic B-scans and power Doppler registrations were performed with continuous and intermittent recordings (ECG triggered at end-systole) in the beating heart and using an external trigger in the asystolic heart in which perfusion was interrupted for 20 seconds. In the beating pig heart, transient harmonic power Doppler imaging provided intensive opacification of the LV cavity and visible myocardial uptake when ECG triggering was performed. In the asystolic pig heart, with uninterrupted perfusion, both triggered and nontriggered registrations showed contrast signals in the LV cavity and in the myocardium. These findings cannot be explained with the known physics of ultrasound contrast media. Stimulated acoustic emission occurring during disintegration of the microbubbles in the acoustic field would explain this phenomenon, which has not yet been described for Levovist.

Journal Article↗

Harmonic Power Doppler Contrast Echocardiography: Preliminary Experimental Results.

This preliminary experimental study demonstrates the potential usefulness of harmonic power Doppler imaging in producing left ventricular myocardial opacification and demonstrating intramyocardial coronary vessels during contrast echocardiography using Levovist, a saccharide-based contrast agent. The contrast effect was most dramatic when a vasodilator such as dipyridamole or nitroglycerin was used in conjunction with contrast injections of Levovist. No significant myocardial opacification was noted with B-mode harmonic imaging alone.

Journal Article↗

Harmonic Power Doppler Contrast Echocardiography: Preliminary Clinical Results.

BACKGROUND: In fundamental and second harmonic echocardiography new contrast media opacify the cavities and reduce the difference in the gray level between the cavity and the myocardium thus obscuring the borders of the myocardium. OBJECTIVES: The aim of the study was to examine the potential usefulness of second harmonic power Doppler imaging (HPD) in providing adequate delineation of the myocardium from the left ventricular (LV) and right ventricular (RV) cavities during intravenous contrast echocardiography. Using HPD, microbubbles in a cavity or a tissue are imaged as colored pixels superimposed on a conventional B-scan image. METHODS: In a pilot study, three healthy volunteers and two patients with ischemic heart disease were investigated using an ATL-HDI 3000 echo system. Four chamber views were obtained using fundamental B-scan, harmonic B-scan two-dimensional echocardiography (H2D) and HPD following intravenous injections of 3 g Levovist(R). RESULTS: Using intermittent scanning/recording, H2D and HPD provided intensive and homogenous contrast effects in the RV and LV cavities. Good delineation of the myocardium was found in all subjects using HPD, whereas in two of three volunteers and in one of two patients ventricular septal and apical endocardial borders were obscured during H2D. No obvious change in myocardial backscatter was visually found with H2D. However, in all three healthy volunteers and in one of two patients, HPD recordings demonstrated patchy and reticular patterns in the myocardium, which were different from the homogenous signals in the LV cavity. These are consistent with imaging of intramyocardial coronary vessels. CONCLUSIONS: HPD with intravenous Levovist is feasible. This technique demonstrated good delineation of ventricular cavities from the myocardium as well as presence of visible contrast in the myocardium. This pilot study justifies further clinical trials to evaluate the clinical benefit of this approach.

Journal Article↗

Color Doppler Visualization of Intramyocardial Coronary Arteries Using a New Echo System: Effect of Contrast Enhancement and Vasodilation.

Utilizing a new echocardiographic system, intramyocardial coronary arteries could be demonstrated by color Doppler in a small number of open chest animals. Both intravenous and intracoronary injections of a contrast agent (Levovist) resulted in significant enhancement of color flow signals with an increase in the length, width, and the number of these vessels. Similar results were obtained with intravenous infusion and direct intracoronary injections of a vasodilator (adenosine). (ECHOCARDIOGRAPHY, Volume 13, November 1996)

Journal Article↗