PubMed Health⌕ Search

Biomedical subjects

Hartmut Becker

Publications and source records attributed to Hartmut Becker.

13 recordsLinked to original sources

Increase of accuracy in intraoperative navigation through high-resolution flat-panel volume computed tomography: experimental comparison with multislice computed tomography-based navigation.

HYPOTHESIS: High-resolution imaging, as provided by flat-panel-based volume computed tomography (fpVCT), could increase navigation accuracy and could therefore improve image-guided procedures or make novel navigated surgery concepts possible. BACKGROUND: Intraoperative navigation is an accepted tool in head and neck surgery. However, its use is limited in the lateral cranial base because of its low surgical accuracy. Surgical accuracy is substantially influenced by the resolution of the underlying data set. The fpVCT offers a resolution of nearly two times higher than multislice computed tomography (MSCT). Target registration error (TRE), as a measurement for surgical navigation accuracy, should decrease when navigation is based on fpVCT data sets. METHODS: An acrylic glass phantom with 37 fiducial points was scanned in a current MSCT and in an experimental fpVCT. Both data sets were imported in an optical navigation system. Five fiducial points were used for registration, and seven points were used for measuring TRE. The distance between the indicated pointer tip and the corresponding fiducial point in data set was measured as TRE. Registration and TRE measurement were repeated five times for each computed tomographic data set. Average TREs were calculated, and results were compared using t-test. RESULTS: The average TRE using MSCT (0.82 mm [standard deviation, 0.35 mm]) was significantly higher than that using fpVCT (0.46 mm [standard deviation, 0.22 mm]) (p < 0.01). CONCLUSION: Submillimeter surgical navigation accuracy is possible using high-resolution fpVCT. This could be highly beneficial in cranial base surgery navigation.

Humans↗

Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease.

Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [(15)O]H(2)O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics.

Acetazolamide↗

Fracture of the occipital condyle caused by minor trauma in child.

We report a case of fractured occipital condyle caused by minor trauma accompanied by light pain on palpation at the lateral cervical trigonum. A 15-year-old boy complained of nuchal pain, particularly pain on palpation at the left lateral cervical trigonum in the absence of neurologic deficits after head deceleration trauma. Computed tomography demonstrated a unilateral nonluxated fracture of the occipital condyle. Owing to consequent immobilization by means of cervical orthosis, pain disappeared after the first 48 hours. Follow-up examination 4 weeks later showed no neurologic deficits. The boy had no severe impairment of movements at the cervical spine.

Accidental Falls↗

Flat-panel volume computed tomography for cochlear implant electrode array examination in isolated temporal bone specimens.

HYPOTHESIS: Flat-panel based volume computed tomography could improve cochlear implant electrode evaluation in comparison with multislice computed tomography. BACKGROUND: Flat-panel based volume computed tomography offers higher spatial resolution and less metal artifacts than multislice computed tomography. Both characteristics could improve the evaluation of challenging but important questions in cochlear implantation assessment, such as an exact imaging of cochlea, osseous spiral lamina, electrode array position, and single electrode contacts. These questions are not currently fully answered by multislice computed tomography. METHODS: Four isolated temporal bone specimens were scanned in a current multislice computed tomography scanner and in two experimental flat-panel based volume computed tomography scanners before and after cochlea implantation. To compare flat-panel based volume computed tomography and multislice computed tomography, four features were rated according to the following criteria: 1) visibility of the cochlea; 2) visibility of the osseous spiral lamina; 3) discernibility of individual electrode contacts; and 4) the ability to determine the electrode array position relative to scala tympani and scala vestibuli. Layer-by-layer microgrinding pictures were used as the ground truth for verification of imaging findings. RESULTS: Flat-panel based volume computed tomography was superior to multislice computed tomography in all four features rated. The cochlea and facial nerve canal were much better delineated in flat-panel based volume computed tomography. The osseous spiral lamina and single electrode contacts were only visible in flat-panel based volume computed tomography. Assessment of implant position with regard to the cochlear spaces was considerably improved by flat-panel based volume computed tomography. CONCLUSION: Cochlear implantation assessment could be improved by flat-panel based volume computed tomography and, therefore, would be highly beneficial for cochlea implantation research and for clinical evaluation. However, these first results were shown by scanning isolated temporal bone specimens; scanning whole human skull bases might be more challenging.

Artifacts↗

Inner ear abnormalities in patients with Goldenhar syndrome.

OBJECTIVE: The objective of this study is to investigate the inner ear malformations in patients with Goldenhar syndrome and to hypothesize the potential embryopathogenesis of these malformations. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS: Fourteen patients with Goldenhar syndrome. INTERVENTIONS: Each patient underwent hearing tests and high-resolution computed tomography (CT) of the temporal bone. In six patients, magnetic resonance imaging of the temporal bone also was performed. RESULTS: Among the 14 patients with Goldenhar syndrome, 13 had outer and middle ear anomalies and 5 (36%) had inner ear malformations, including one case of common cavity. CONCLUSIONS: Our observations regarding inner ear anomalies in Goldenhar syndrome correlate with the reported cases in the literature and may help to hypothesize the embryological origin of these malformations, which can caused by an early developmental arrest in the fourth gestational week. Specialists evaluating patients with Goldenhar syndrome should be aware of the possibility of inner ear malformations, which could be diagnosed earlier with appropriate imaging studies.

Adult↗

Experimental flat-panel high-spatial-resolution volume CT of the temporal bone.

BACKGROUND AND PURPOSE: A CT scanner employing a digital flat-panel detector is capable of very high spatial resolution as compared with a multi-section CT (MSCT) scanner. Our purpose was to determine how well a prototypical volume CT (VCT) scanner with a flat-panel detector system defines fine structures in temporal bone. METHODS: Four partially manipulated temporal-bone specimens were imaged by use of a prototypical cone-beam VCT scanner with a flat-panel detector system at an isometric resolution of 150 microm at the isocenter. These specimens were also depicted by state-of-the-art multisection CT (MSCT). Forty-two structures imaged by both scanners were qualitatively assessed and rated, and scores assigned to VCT findings were compared with those of MSCT. RESULTS: Qualitative assessment of anatomic structures, lesions, cochlear implants, and middle-ear hearing aids indicated that image quality was significantly better with VCT (P < .001). Structures near the spatial-resolution limit of MSCT (e.g., bony covering of the tympanic segment of the facial canal, the incudo-stapedial joint, the proximal vestibular aqueduct, the interscalar septum, and the modiolus) had higher contrast and less partial-volume effect with VCT. CONCLUSION: The flat-panel prototype provides better definition of fine osseous structures of temporal bone than that of currently available MSCT scanners. This study provides impetus for further research in increasing spatial resolution beyond that offered by the current state-of-the-art scanners.

Artifacts↗

Functional MR imaging of the auditory cortex with electrical stimulation of the promontory in 35 deaf patients before cochlea implantation.

BACKGROUND AND PURPOSE: Promontory testing is used for preoperative assessment of the auditory pathway before cochlear implantation. This method depends on patient cooperation and cannot be used in children or disabled persons. Promontory stimulation during functional MR imaging (fMRI) provides a new and objective method to test the integrity of the auditory pathway. To evaluate the method, we performed this prospective study in deaf adult patients. METHODS: fMRI of the auditory pathway with electrical stimulation of the promontory was performed in 35 profoundly deaf patients, bilaterally in seven. For safe stimulation inside the MR environment, a specially designed nerve stimulator was used. We acquired nine sections parallel to the sylvian fissure by using an echo-planar pulse sequence (1.5 T). To evaluate the number of pixels in the auditory cortex, areas were counted and the minimum confidence level (p(st) value) was determined. The auditory pathway was called intact when the minimal p(st) value was 10(-5) or when the minimal p(st) value was 10(-4) in at least five activated pixels. RESULTS: Images in 85% of patients reporting an auditory sensation showed activation of the contralateral auditory cortex. In the group of patients reporting no hearing sensation, images in 75% did not show activation. CONCLUSION: This method can prove the intactness of the auditory pathway and help the surgeon in decision making before cochlear implantation. However, a negative finding should not be interpreted as indicating a nonfunctioning auditory pathway. Additional technical refinements and experience are needed to further improve this method.

Adult↗

Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography.

Virtual endoscopy (VE) enables non-invasive 3D endoluminal imaging of the middle ear by post-processing of CT data. To optimise the clinical application a standardised approach was evaluated in normal and pathologic cases. Data acquisition was performed using multi-slice helical CT in 20 normal patients and 15 patients with malformation or trauma. Virtual endoscopy of the tympanic cavity and 3D images of the ossicles were generated using surface and volume rendering. Qualitative assessment of the representation of anatomical structures was performed in normal patients. In 15 pathological cases the diagnostic benefit was evaluated by comparing the 3D images to the 2D images and intra-operative findings. In all 35 cases 3D imaging was possible using the standardised approach. The ossicular chain as well as the bony and soft tissue structures of the tympanic cavity were visualised in 20 normal patients. In 7 of 8 patients with malformation and 1 of 7 patients with trauma the original diagnosis was changed by 3D imaging. Standardisation and evaluation of the method in normal patients is essential as it enhances the diagnostic reliability. Virtual endoscopy facilitates understanding of the complex anatomy of the middle ear. In cases of suspected malformation and confirmed trauma it is helpful for diagnosis and surgical planning.

Adolescent↗

Comparison of perfusion computed tomography with diffusion-weighted magnetic resonance imaging in hyperacute ischemic stroke.

OBJECTIVE: In this study, perfusion CT and diffusion-weighted magnetic resonance imaging (DWI) were compared as means of assessing the ischemic brain in hyperacute stroke. METHODS: Twenty patients with ischemic stroke underwent perfusion computed tomography (CT) and magnetic resonance imaging (MRI) studies <3 hours after stroke onset. Cerebral blood flow thresholds were used to delineate the ischemic lesion, penumbra, and infarct. Correlations between the volume of the hypoperfused areas, the abnormality volume in admission DWI and follow-up CT/MRI studies, and the clinical National Institutes of Health Stroke Scale (NIHSS) scores were performed. RESULTS: The volume of the ischemic (core and penumbra) lesion on admission perfusion CT was correlated with the volume of admission DWI abnormalities (r=0.89, P=0.001). The infarcted core tissue volume (on admission CT) correlated more strongly (r=0.77, P=0.0001) than the admission DWI abnormality volume (r=0.69, P=0.002) with the follow-up infarct volume on fluid-attenuated inversion recovery images. A correlation was demonstrated between infarct volume in perfusion CT and follow-up DWI abnormality volume (r=0.89, r=0.77, P=0.002). Significant correlations were found between ischemic and infarct region volumes in perfusion CT and NIHSS admission and follow-up scores (P < or = 0.01). CONCLUSIONS: Both imaging modalities provide a sufficient assessment of the hyperacute brain infarct, with significant correlation between them and the clinical condition at admission. Perfusion CT allows differentiation of the penumbra and infarct core region with significant predictive value of follow-up infarct volume and clinical outcome.

Adult↗

Three-dimensional visualization of the nasal cavity and paranasal sinuses. Clinical results of a standardized approach using multislice helical computed tomography.

OBJECTIVE: The aim of this study was to introduce 3-dimensional (3D) visualization of the nasal cavity and paranasal sinuses as a diagnostic tool and to examination the clinical results of its standardized application. METHODS: One hundred sixty patients with chronic or acute nasal symptoms underwent helical computed tomography scanning and fiberoptic endoscopy of the sinuses, and 120 of them underwent endoscopic sinus surgery. The 3D images were compared with the axial and multiplanar reconstructed images using a checklist comprising important anatomic landmarks. After qualitative assessment of the representation of anatomic structures in healthy subjects, the method was applied to pathologic cases. The 3D images of these patients were correlated with the preoperative and intraoperative findings. RESULTS: Six hundred virtual endoscopies (VEs) were performed. The VE views allowed a realistic illustration of the various pathologic findings, except from cases with highly obstructive sinonasal disease. The correlation between the preoperative fiberoptic endoscopy and the intraoperative findings was significant (r = 0.83, P = 0.001). CONCLUSION: The standardized clinical application of this method serves as an important supplement to 2-dimensional slices and conventional endoscopy.

Adult↗

Registration and fusion of CT and MRI of the temporal bone.

OBJECTIVE: To present and evaluate a registration method to fuse complementary information of CT and MRI of the temporal bone. METHODS: CT and MRI of the temporal bone of 26 patients were independently registered 4 times. A manual, iterative, intrinsic, rigid, and retrospective registration method was used. Mean CREm (consistency registration error) was calculated as a reproducibility measurement. RESULTS: CREm was 0.6 mm (95% CI = 0.52-0.68 mm). T-test revealed no difference between pathologic and normal cases (t[102] = -1.71; P = 0.09). Time needed: 13 minutes. In the registered and fused datasets, important bony surgical landmarks (eg, facial nerve canal, inner ear) could be assessed in 3 dimensions relatively to tumor tissue (eg, acoustic schwannoma). Fluid distribution within partially obliterated cochleae could be assigned to either scalae. CONCLUSION: An accurate, reproducible registration and fusion method that improves tumor surgery and cochlea implantation planning with only minor changes to the clinical workflow was presented and described. We suggest this method in selected cases.

Adolescent↗

High-resolution flat-panel volume-CT of temporal bone--part 1: axial preoperative anatomy.

The purpose of this four-part series is to show the high-resolution axial and coronal anatomy of the temporal bone from a flat-panel detector-based volume CT (parts 1 and 2); these imaging planes are then used to outline the effect of different surgical procedures commonly applied to the temporal bone (parts 3 and 4). The structures that are removed or altered in 11 different surgical procedures are color-coded and inscribed in axial and coronal sections. Clinically important imaging features and complications following these surgeries will also be discussed. In these high-resolution images, many structures that are below the resolution limit of conventional CT can be seen and localized. It is hoped that one would be able to picture these structures and surgeries, in the mind's eye, even when they fall below the resolution limit using a conventional CT scanner. This article (part 1) focuses on the preoperative axial anatomy.

Humans↗

High-resolution computed tomography of temporal bone: Part II: coronal preoperative anatomy.

The purpose of this 4-part series is to demonstrate the high-resolution axial and coronal anatomy of temporal bone from a flat-panel detector-based volume computed tomography (CT) scanner (parts I and II); these imaging planes are then used to outline the effect of different surgical procedures commonly applied to the temporal bone (parts III and IV). The structures that are removed and/or altered in 11 different surgical procedures are color coded and inscribed in axial and coronal sections. Clinically important imaging features and complications after these operations are also discussed. In these high-resolution images, many structures that are below the resolution limit of conventional CT can be seen and localized. It is hoped that this exposition enables one to visualize these structures and surgeries in the mind's eye, even when they fall below the resolution limit using a conventional CT scanner. This article (part II) focuses on the preoperative coronal anatomy.

Cadaver↗