PubMed Health⌕ Search

Biomedical subjects

Heiko Dreeskamp

Publications and source records attributed to Heiko Dreeskamp.

3 recordsLinked to original sources

Treatment of experimentally induced aneurysms with stents.

OBJECTIVE: Although Guglielmi detachable coil systems have been widely accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents, stent grafts, or implantation of coils after stent placement constitute emerging techniques in endovascular treatment. The aim of the present study was to use an animal model to investigate these different approaches to treat cerebral aneurysms with regard to the rate of closure and the histopathological changes within the aneurysm cavity and the parent vessel after stent placement. METHODS: We created aneurysms in 30 rabbits by distal ligation and intraluminal incubation of the right common carotid artery with elastase. Ten animals were treated with porous stents alone, 10 animals with stent grafts (covered stents), and 10 animals with stents and additional coiling via the interstices of the stent, which enabled dense packing of the coils. Five animals in each group were observed for 1 month and the other animals for 3 months. Histological analyses were performed, including immunohistochemical investigations for estimating the proliferation of the intima and possible inflammatory infiltration. RESULTS: Covered stents led to a complete and stable aneurysm occlusion with only minimal proliferative carrier vessel wall changes. One covered stent was completely occluded with old thrombus, and the other 9 remained patent. Porous stents occluded two of five aneurysms in the 1-month follow-up group and four of five after 3 months. However, progressive sprouting of neointima inside the carrier vessel that resulted in a stenosis of up to 40% was present. In the Stent + Coil group, one aneurysm showed recanalization after 1 month, and three of five aneurysms were recanalized after 3 months after coil compaction. Moreover, in-stent stenosis of up to 30% was present. CONCLUSION: This study demonstrates the possible shortcomings and problems of emerging stent techniques to treat intracerebral aneurysms, shows where technical advances have to be made, and describes in which cases of aneurysm morphology caution has to be exercised when considering an endovascular approach using stents.

Aneurysm↗

A refined method for creating saccular aneurysms in the rabbit.

We describe a refined animal model of human intracerebral aneurysms for testing endovascular devices for interventional neuroradiological procedures. Saccular aneurysms resulting from a stump of the right common carotid artery (CCA) were created in 15 New Zealand White rabbits by intraluminal incubation of elastase that was applied to the CCA after distal ligation of the CCA and proximal occlusion of the vessel using a pliable balloon. Subsequently a microcatheter was advanced to a position cranial to the balloon and the elastase was infused under fluoroscopic guidance to avoid retrograde flow to the trachea via aberrant vessels. Contrast-enhanced (CE) MRA at 1.5 T and conventional digital subtraction angiography was performed to test for aneurysm size, morphology and neck anatomy. In all 15 animals aneurysms resulted from the stump of the right CCA, ranging in size from 2.0 to 9.9 mm (mean 6.3 mm) in craniocaudal direction, 1.0 to 5.5 mm (mean 3.8 mm) in mediolateral direction and 1.0 to 3.8 mm (mean 2.4 mm) in neck diameter. Aneurysm morphology could be adequately demonstrated using CE MRA. On histological evaluation a loss of the internal elastic lamina was noted. The described method represents an easy, reliable, and reproducible method of aneurysm creation in the rabbit in an area of high shear stress. These aneurysms can be used for testing new endovascular devices for embolization of intracranial aneurysms.

Angiography, Digital Subtraction↗

Time-of-flight-, phase contrast and contrast enhanced magnetic resonance angiography for pre-interventional determination of aneurysm size, configuration, and neck morphology in an aneurysm model in rabbits.

We describe three different magnetic resonance (MR)-angiography techniques to evaluate aneurysm size, configuration, and neck morphology of experimentally created aneurysms in a rabbit model. In five New Zealand White rabbits an aneurysm was created by endovascular occlusion of the right common carotid artery (CCA) using a pliable balloon and subsequent endoluminal incubation of elastase within the proximal CCA above the balloon and distal ligation of the vessel. In all animals, time-of-flight (TOF), phase contrast and contrast enhanced (CE) MR angiographies (MRA) were performed and compared to conventional digital subtraction angiography results. We found, that aneurysms are best visualized employing CE MRA, however, neck morphology was also found to demonstrate interpretable results when evaluating the axial source data of the TOF MRA. The animal model we used can be employed for testing endovascular devices such as new coil material, or covered stents. The described MRA techniques might then be helpful for pre-interventional planning and maybe even for the follow-up of the thus treated aneurysms.

Aneurysm↗